{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T22:34:00Z","timestamp":1791326040809,"version":"4.3.1"},"reference-count":46,"publisher":"MDPI AG","issue":"13","license":[{"start":{"date-parts":[[2023,6,27]],"date-time":"2023-06-27T00:00:00Z","timestamp":1687824000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>The primary objective of this study was to objectively compare the visual performance of patients following premium pseudophakic presbyopia corrections in different light combinations for near- and intermediate-vision activities of daily living (ADLs). This is a prospective, comparative study. A total of 75 patients populated three study groups: G1-patients with bilateral trifocal implantation, G2-patients with bilateral bifocal implantation, and G3-patients with bilateral monofocal implantation. All participants addressed 10 ADLs in nine combinations of light temperature (3000 K, 4000 K, and 6000 K) and light intensity (25 fc, 50 fc, and 75 fc) and declared their subjectively optimal light combination while reading. G2 and G3 had the best total ADL scores in 6000 K\/75 fc, while G1 had the best total ADL score in 4000 K\/75 fc. Total ADL, easy ADL, and moderate difficulty ADL scores were significantly better in G2, while difficult ADL score was significantly better in G1. The majority of all groups selected 6000 K\/75 fc as the most comfortable light combination, and no group selected 3000 K and 25 fc. In conclusion, trifocal patients benefit from intense daylight, while bifocal and monofocal patients benefit from intense, cold lighting. Trifocal patients present superior near-vision capacity in difficult near-vision daily tasks, while bifocal patients present superiority in easy and moderate-difficulty ADLs.<\/jats:p>","DOI":"10.3390\/jcm12134324","type":"journal-article","created":{"date-parts":[[2023,6,28]],"date-time":"2023-06-28T00:45:11Z","timestamp":1687913111000},"page":"4324","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Impact of Light Conditions on Visual Performance following Premium Pseudophakic Presbyopia Corrections"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0826-3959","authenticated-orcid":false,"given":"Eirini-Kanella","family":"Panagiotopoulou","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, University Hospital of Alexandroupolis, 68100 Alexandroupolis, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0471-0371","authenticated-orcid":false,"given":"Kostas","family":"Boboridis","sequence":"additional","affiliation":[{"name":"Ophthalmology Department, AHEPA University Hospital, 54636 Thessaloniki, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3665-5271","authenticated-orcid":false,"given":"Ioannis","family":"Seimenis","sequence":"additional","affiliation":[{"name":"Medical Physics Laboratory, School of Medicine, National and Kapodistrian University of Athens, 11527 Athens, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4364-1943","authenticated-orcid":false,"given":"Georgios","family":"Labiris","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University Hospital of Alexandroupolis, 68100 Alexandroupolis, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,6,27]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"121","DOI":"10.4103\/tjo.tjo_53_18","article-title":"Correction of presbyopia: An integrated update for the practical surgeon","volume":"8","author":"Balgos","year":"2018","journal-title":"Taiwan J. Ophthalmol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1111\/j.1444-0938.2008.00256.x","article-title":"The eye in focus: Accommodation and presbyopia","volume":"91","author":"Charman","year":"2008","journal-title":"Clin. Exp. Optom."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1016\/j.ajo.2007.12.011","article-title":"The quality of life associated with presbyopia","volume":"145","author":"Luo","year":"2008","journal-title":"Am. J. Ophthalmol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1731","DOI":"10.1001\/archopht.126.12.1731","article-title":"Global vision impairment due to uncorrected presbyopia","volume":"126","author":"Holden","year":"2008","journal-title":"Arch. Ophthalmol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1097\/01.ico.0000178722.19317.7b","article-title":"Surgical monovision and monovision reversal in LASIK","volume":"25","author":"Reilly","year":"2006","journal-title":"Cornea"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"325","DOI":"10.3928\/1081-597X-20040701-04","article-title":"Monovision laser in situ keratomileusis for pre-presbyopic and presbyopic patients","volume":"20","author":"Miranda","year":"2004","journal-title":"J. Refract. Surg."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1097\/ICU.0000000000000162","article-title":"PresbyLASIK approach for the correction of presbyopia","volume":"26","author":"Pallikaris","year":"2015","journal-title":"Curr. Opin. Ophthalmol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"288","DOI":"10.3928\/1081597X-20220323-01","article-title":"Visual and Refractive Outcomes Following Laser Blended Vision With Non-linear Aspheric Micro-anisometropia (PRESBYOND) in Myopic and Hyperopic Patients","volume":"38","author":"Russo","year":"2022","journal-title":"J. Refract. Surg."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1097\/j.jcrs.0000000000001042","article-title":"Presbyopia correction using the monocular bi-aspheric ablation profile in myopic eyes","volume":"49","author":"Ryu","year":"2023","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"12","DOI":"10.3928\/1081597X-20121210-01","article-title":"Visual outcomes and safety of a refractive corneal inlay for presbyopia using femtosecond laser","volume":"29","author":"Limnopoulou","year":"2013","journal-title":"J. Refract. Surg."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.5301\/ejo.5000492","article-title":"Patient satisfaction and spectacle independence with the iSert multifocal lens","volume":"25","author":"Labiris","year":"2015","journal-title":"Eur. J. Ophthalmol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"746","DOI":"10.3928\/1081597X-20151021-03","article-title":"Straylight measurements in two different apodized diffractive multifocal intraocular lenses","volume":"31","author":"Labuz","year":"2015","journal-title":"J. Refract. Surg."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1016\/j.ajo.2015.07.021","article-title":"Clinical outcomes following implantation of diffractive multifocal intraocular lenses with varying add powers","volume":"160","author":"Kim","year":"2015","journal-title":"Am. J. Ophthalmol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"2797","DOI":"10.4103\/ijo.IJO_2259_20","article-title":"Review of current status of refractive lens exchange and role of dysfunctional lens index as its new indication","volume":"68","author":"Kaweri","year":"2020","journal-title":"Indian J. Ophthalmol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.jcrs.2014.06.015","article-title":"Mini-monovision versus multifocal intraocular lens implantation","volume":"41","author":"Labiris","year":"2015","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Ali, J.L., and Pikkel, J. (2019). Multifocal Intraocular Lenses. The Art and the Practice, Springer Nature. [2nd ed.].","DOI":"10.1007\/978-3-030-21282-7"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1097\/APO.0000000000000296","article-title":"Extended Depth-of-Field Intraocular Lenses: An Update","volume":"9","author":"Kanclerz","year":"2020","journal-title":"Asia Pac. J. Ophthalmol."},{"key":"ref_18","unstructured":"AcrySof IQ Panoptix (2023, April 09). Summary of Safety and Effectiveness Data, Available online: https:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf4\/P040020S087B.pdf."},{"key":"ref_19","unstructured":"Acrysof IQ Restor (2023, April 09). Product Information, Available online: https:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf4\/P040020S050d.pdf."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1097\/00006324-200105000-00019","article-title":"Timed instrumental activities of daily living tasks: Relationship to visual function in older adults","volume":"78","author":"Owsley","year":"2001","journal-title":"Optom. Vis. Sci."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1186\/s40662-016-0067-1","article-title":"Evaluation of activities of daily living following pseudophakic presbyopic correction","volume":"19","author":"Labiris","year":"2017","journal-title":"Eye Vis."},{"key":"ref_22","first-page":"e24548","article-title":"Development and Validation of a Lighting Facility for the Objective Assessment of the Visual Performance of Presbyopic Patients in a Series of Activities of Daily Living","volume":"28","author":"Labiris","year":"2022","journal-title":"Cureus"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"4553","DOI":"10.2147\/OPTH.S326139","article-title":"Lighting Standards Revisited: Introduction of a Mathematical Model for the Assessment of the Impact of Illuminance on Visual Acuity","volume":"28","author":"Labiris","year":"2021","journal-title":"Clin. Ophthalmol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1097\/APO.0000000000000253","article-title":"AcrySof IQ PanOptix intraocular lens versus extended depth of focus intraocular lens and trifocal intraocular lens: A clinical overview","volume":"8","author":"Sudhir","year":"2019","journal-title":"Asia Pac. J. Ophthalmol."},{"key":"ref_25","unstructured":"Hammond, M.D. (2023, May 05). Lens Expands Reach of Presbyopia Correction. With Uncompromised Distance, More Patients May Benefit. 2018, Novartis 7\/18 US-RES-17-E-1143(1)a. Available online: https:\/\/www.ophthalmologymanagement.com\/sponsored-content\/us-res-17-e-1143(1)a-hammond."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1007\/s00347-014-3170-5","article-title":"Pupil centroid shift: Marketing tool or essential clinical parameter?","volume":"112","author":"Fischinger","year":"2015","journal-title":"Ophthalmologe"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1007\/s10633-019-09693-8","article-title":"Adaptation time, electroretinography, and pupillography in healthy subjects","volume":"139","author":"Asakawa","year":"2019","journal-title":"Doc. Ophthalmol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s10633-014-9473-7","article-title":"ISCEV Standard for full-field clinical electroretinography (2015 update)","volume":"130","author":"McCulloch","year":"2015","journal-title":"Doc. Ophthalmol."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1186\/s40662-020-00216-0","article-title":"Introduction of a digital near-vision reading test for normal and low vision adults: Development and validation","volume":"22","author":"Labiris","year":"2020","journal-title":"Eye Vis."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"3915","DOI":"10.2147\/OPTH.S314943","article-title":"Development and Validation of a Web-Based Reading Test for Normal and Low Vision Patients","volume":"22","author":"Labiris","year":"2021","journal-title":"Clin. Ophthalmol."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1097\/OPX.0b013e3180dc9a60","article-title":"A modified ETDRS visual acuity chart for European-wide use","volume":"84","author":"Plainis","year":"2007","journal-title":"Optom. Vis. Sci."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1001\/archopht.119.7.1050","article-title":"National Eye Institute Visual Function Questionnaire Field Test Investigators. Development of the 25-item National Eye Institute Visual Function Questionnaire","volume":"119","author":"Mangione","year":"2001","journal-title":"Arch. Ophthalmol."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Labiris, G., Katsanos, A., Fanariotis, M., Tsirouki, T., Pefkianaki, M., Chatzoulis, D., and Tsironi, E. (2008). Psychometric properties of the Greek version of the NEI-VFQ 25. BMC Ophthalmol., 6.","DOI":"10.1186\/1471-2415-8-4"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1111\/aos.12308","article-title":"Review of the impact of presbyopia on quality of life in the developing and developed world","volume":"92","author":"Goertz","year":"2014","journal-title":"Acta Ophthalmol."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1855","DOI":"10.1016\/j.jcrs.2008.07.024","article-title":"A United States cost-benefit comparison of an apodized, diffractive, presbyopia-correcting, multifocal intraocular lens and a conventional monofocal lens","volume":"34","author":"Maxwell","year":"2008","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"5656","DOI":"10.1167\/iovs.16-20008","article-title":"The effect of light level and small pupils on presbyopic reading performance","volume":"57","author":"Xu","year":"2016","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_37","first-page":"777","article-title":"Transmission of the ocular media","volume":"1","author":"Boettner","year":"1962","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_38","unstructured":"(2023, April 20). ReluxInformatik AG M\u00fcnchenstein. Available online: https:\/\/reluxnet.relux.com\/en\/downloads.html."},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Papalambrou, A., and Doulos, L.T. (2019). Identifying, examining, and planning areas protected from light pollution. The case study of planning the first national dark sky park in Greece. Sustainability, 11.","DOI":"10.3390\/su11215963"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1080\/00221309.1932.9918454","article-title":"The Measurement of Retinal Illumination","volume":"7","author":"Purdy","year":"1932","journal-title":"J. Gen. Psychol."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1177\/147715356102600204","article-title":"Retinal Illumination and Age","volume":"26","author":"Weale","year":"1961","journal-title":"Trans. Illum. Eng. Soc."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.visres.2020.09.004","article-title":"Brightness perception changes related to pupil size","volume":"178","author":"Sulutvedt","year":"2021","journal-title":"Vis. Res."},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Son, H.S., Labuz, G., Khoramnia, R., Merz, P., Yildirim, T.M., and Auffarth, G.U. (2020). Ray propagation imaging and optical quality evaluation of different intraocular lens models. PLoS ONE, 15.","DOI":"10.1371\/journal.pone.0233829"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"36","DOI":"10.5301\/ejo.5000994","article-title":"Visual acuity and image quality in 5 diffractive intraocular lenses","volume":"28","author":"Cardona","year":"2018","journal-title":"Eur. J. Ophthalmol."},{"key":"ref_45","first-page":"2105","article-title":"Optical bench performance of AcrySof(\u00ae) IQ ReSTOR(\u00ae), AT LISA(\u00ae) tri, and FineVision(\u00ae) intraocular lenses","volume":"8","author":"Carson","year":"2014","journal-title":"Clin. Ophthalmol."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"2639","DOI":"10.2147\/OPTH.S180766","article-title":"Impact of light conditions on reading ability following multifocal pseudophakic corrections","volume":"14","author":"Labiris","year":"2018","journal-title":"Clin. Ophthalmol."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/12\/13\/4324\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T20:02:10Z","timestamp":1760126530000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/12\/13\/4324"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,27]]},"references-count":46,"journal-issue":{"issue":"13","published-online":{"date-parts":[[2023,7]]}},"alternative-id":["jcm12134324"],"URL":"https:\/\/doi.org\/10.3390\/jcm12134324","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,6,27]]}}}