{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T00:57:49Z","timestamp":1783040269297,"version":"3.54.6"},"reference-count":26,"publisher":"MDPI AG","issue":"20","license":[{"start":{"date-parts":[[2023,10,23]],"date-time":"2023-10-23T00:00:00Z","timestamp":1698019200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Background: Presently, the management of patients with maxilla bone defects of the Cawood V or VI class is achieved using zygomatic or individual implants or through augmentation of the bone. For zygomatic implants, the ORIS criteria represent the most common factor in helping practitioners register success rates. The zygomatic anatomy-guided approach (ZAGA)and zygomatic orbital floor (ZOF) are factors that are crucial to examining the anatomy of a particular patient before the procedure. The aim of thisarticle is to find the statistical relationship between the abovementioned terms and other factors. Methods: A total of 81 patients underwent zygomatic implant procedures in different configurations. The ORIS, ZAGA, and ZOF parameters were compared with other factors such as type of surgery, sex, age, and the anatomy of the zygomatic bone. Results: Most patients in this article were classified as ZAGA Class 2. The relationships between type of surgery and ZAGA classification, and ZAGA and sinus\/maxilla zygomatic implant localization were statistically significant. Conclusions: The ZAGA and ZOF scales are practical and valuable factors that should be taken into account before surgery, whereas to date, criteria better than the ORIS scale have not been described in terms of the success of zygomatic implants. The ZOF scale might omit perforation of the orbit because this parameter warns a practitioner to be aware of the anatomy of the orbit.<\/jats:p>","DOI":"10.3390\/jcm12206681","type":"journal-article","created":{"date-parts":[[2023,10,23]],"date-time":"2023-10-23T05:54:35Z","timestamp":1698040475000},"page":"6681","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["The Zygomatic Anatomy-Guided Approach, Zygomatic Orbital Floor Classification, and ORIS Criteria\u2014A 10-Year Follow-Up"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9897-5003","authenticated-orcid":false,"given":"Rafal","family":"Zielinski","sequence":"first","affiliation":[{"name":"Stomatologia na Ksiezym Mlynie, 16D Tymienieckiego, 90-365 Lodz, Poland"},{"name":"Department of Maxillofacial Surgery, Medical University of Lodz, 113st Zeromskiego, 90-001 Lodz, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6879-4973","authenticated-orcid":false,"given":"Jakub","family":"Okulski","sequence":"additional","affiliation":[{"name":"Department of Maxillofacial Surgery, Medical University of Lodz, 113st Zeromskiego, 90-001 Lodz, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2648-5523","authenticated-orcid":false,"given":"Wojciech","family":"Simka","sequence":"additional","affiliation":[{"name":"Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9200-2828","authenticated-orcid":false,"given":"Marcin","family":"Kozakiewicz","sequence":"additional","affiliation":[{"name":"Department of Maxillofacial Surgery, Medical University of Lodz, 113st Zeromskiego, 90-001 Lodz, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,10,23]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1080\/02844310310023918","article-title":"Zygoma fixture in the management of advanced atrophy of the maxilla: Technique and long-term results","volume":"38","author":"Ohrnell","year":"2004","journal-title":"Scand. J. Plast. Reconstr. Surg. Hand Surg."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1111\/j.1708-8208.2007.00046.x","article-title":"The establishment of a protocol for the total rehabilitation of atrophic maxillae employing four zygomatic fixtures in an immediate loading system\u2014A 30-month clinical and radiographic follow-up","volume":"9","author":"Duarte","year":"2007","journal-title":"Clin. Implant. Dent. Relat. Res."},{"key":"ref_3","first-page":"169","article-title":"5-year outcome of cross-arch prostheses supported by four immediately loaded zygomatic implants: A prospective case series","volume":"8","author":"Pons","year":"2015","journal-title":"Eur. J. Oral Implantol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"21","DOI":"10.11607\/jomi.8417","article-title":"Quad zygomatic implants: A systematic review and meta-analysis on survival and complications","volume":"36","author":"Lan","year":"2021","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"938","DOI":"10.1016\/j.ijom.2017.02.002","article-title":"Additively manufactured sub-periosteal jaw implants","volume":"46","author":"Mommaerts","year":"2017","journal-title":"Int. J. Oral Maxillofac. Surg."},{"key":"ref_6","first-page":"145","article-title":"Immediately loaded zygomatic implants vs conventional dental implants in augmented atrophic maxillae: 1-year post-loading results from a multicentre randomized controlled trial","volume":"11","author":"Felice","year":"2018","journal-title":"Eur. J. Oral Implantol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"366","DOI":"10.11607\/jomi.7488","article-title":"ORIS Criteria of Success for the Zygoma-Related Rehabilitation: The (Revisited) Zygoma Success Code","volume":"35","author":"Aparicio","year":"2020","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1111\/prd.12038","article-title":"Zygomatic implants: Indications, techniques and outcomes, and the Zygomatic Success","volume":"66","author":"Aparicio","year":"2014","journal-title":"Periodontology"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"373","DOI":"10.14219\/jada.archive.1979.0052","article-title":"Recommendations of the consensus development conference on dental implants","volume":"98","author":"Schnitman","year":"1979","journal-title":"J. Am. Dent. Assoc."},{"key":"ref_10","first-page":"11","article-title":"The long-term efficacy of currently used dental implants: A review and proposed criteria of success","volume":"1","author":"Albrektsson","year":"1986","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_11","unstructured":"Lang, N.P., and Karring, T. (1993, January 1\u20134). Consensus report of Session IV. Proceedings of the 1st European Workshop on Periodontology, Thurgau, Switzerland."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1016\/S0022-3913(98)70047-2","article-title":"Editorial: Towards optimized treatment outcomes for dental implants","volume":"80","author":"Zarb","year":"1998","journal-title":"J. Prosthet. Dent."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1046\/j.0909-8836..t01-6-.x","article-title":"Biological factors contributing to failures of osseointegrated oral implants.(II). Etiopathogenesis","volume":"106","author":"Esposito","year":"1998","journal-title":"Eur. J. Oral Sci."},{"key":"ref_14","first-page":"s123","article-title":"Long-term clinical outcome of implants with different surface modifications","volume":"11","author":"Wennerberg","year":"2018","journal-title":"Eur. J. Oral Implant."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"s1","DOI":"10.1016\/S0194-5998(97)70001-9","article-title":"Adult rhinosinusitis defined","volume":"117","author":"Lanza","year":"1997","journal-title":"Otolaryngol. Head Neck Surg."},{"key":"ref_16","first-page":"183","article-title":"Staging in rhinosinusitis","volume":"31","author":"Lund","year":"1993","journal-title":"Rhinology"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1111\/j.1708-8208.2008.00130.x","article-title":"Extra-sinus zygomatic implants: Three year experience from a new surgical approach for patients with pronounced buccal concavities for the edentulous maxilla","volume":"12","author":"Aparicio","year":"2010","journal-title":"Clin. Implant. Dent. Relat. Res."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1111\/j.1708-8208.2006.00009.x","article-title":"A prospective clinical study on titanium implants in the zygomatic arch for prosthetic rehabilitation of the atrophic edentulous maxilla with a follow-up of 6 months to 5 years","volume":"8","author":"Aparicio","year":"2006","journal-title":"Clin. Implant. Dent. Relat. Res."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1111\/j.1600-0757.2008.00259.x","article-title":"The use of zygomatic implants for prosthetic rehabilitation of the severely re-sorbedmaxilla","volume":"47","author":"Aparicio","year":"2008","journal-title":"Periodontology"},{"key":"ref_20","first-page":"232","article-title":"Surgical modifications to the Branemark zygomaticus protocol in the treatment of the severely resorbed maxilla: A clinical report","volume":"18","author":"Howes","year":"2003","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1016\/S0022-3913(08)60237-1","article-title":"A new approach to rehabili-tate the severely atrophic maxilla using extramaxillary anchored implants in immediate function: A pilot study","volume":"100","author":"Malo","year":"2008","journal-title":"J. Prosthet. Dent."},{"key":"ref_22","first-page":"645","article-title":"Rehabilitation of severely atrophic maxillae with fixed implant-supported prostheses using zygomatic implants placed using the sinus slot technique: Clinical report on a series of 21 patients","volume":"22","author":"Boronat","year":"2007","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_23","first-page":"889","article-title":"Sinus slot technique for simplification and improved orientation of zygomaticus dental implants: A technical note","volume":"15","author":"Stella","year":"2000","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1111\/j.1600-051X.2004.00505.x","article-title":"Critical soft tissue parameters of the zygomatic implant","volume":"31","author":"Wegener","year":"2004","journal-title":"J. Clin. Periodontol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1111\/j.1708-8208.2005.tb00060.x","article-title":"Evaluation of 31 zygomatic implants and 74 regular dental implants used in 16 patients for prosthetic reconstruction of the atrophic maxilla with cross-arch fixed bridges","volume":"7","author":"Becktor","year":"2005","journal-title":"Clin. Implant. Dent. Relat. Res."},{"key":"ref_26","first-page":"399","article-title":"Rehabilitation of severely resorbed maxillae with zygomatic implants: An evaluation of implant stability, tissue conditions, and patients opinion before and after treatment","volume":"21","author":"Farzad","year":"2006","journal-title":"Int. J. Oral Maxillofac. Implant."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/12\/20\/6681\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T21:10:07Z","timestamp":1760130607000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/12\/20\/6681"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,23]]},"references-count":26,"journal-issue":{"issue":"20","published-online":{"date-parts":[[2023,10]]}},"alternative-id":["jcm12206681"],"URL":"https:\/\/doi.org\/10.3390\/jcm12206681","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,10,23]]}}}