{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T14:39:29Z","timestamp":1792075169427,"version":"4.4.0"},"reference-count":37,"publisher":"MDPI AG","issue":"22","license":[{"start":{"date-parts":[[2023,11,14]],"date-time":"2023-11-14T00:00:00Z","timestamp":1699920000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Bicuspid aortic valve (BAV) is the most common congenital heart disease, with a prevalence of 1\u20132% and occurring in &gt;20% of octogenarians referred for aortic valve replacement. However, BAV patients have been systematically excluded from pivotal randomized trials. Since TAVI indications are moving toward low-risk patients, an increase in the number of BAV patients who undergo TAVI is expected. BAV represents a challenge due to its unique morphological features (raphe, extreme asymmetrical valve calcifications, cusp asymmetry and aortopathy) and the lack of consensus about the accurate sizing method. The role of multi-slice computed tomography (MSCT) in the planification of the TAVI procedure is well-established, being useful to define the optimal valve sizing and the implantation strategy. New-generation devices, more experience of the operators and better planification of the procedure have been associated with similar clinical outcomes in bicuspid and tricuspid patients undergoing TAVI.<\/jats:p>","DOI":"10.3390\/jcm12227074","type":"journal-article","created":{"date-parts":[[2023,11,14]],"date-time":"2023-11-14T02:20:37Z","timestamp":1699928437000},"page":"7074","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Transcatheter Aortic Valve Implantation for Bicuspid Aortic Valve Disease: Procedural Planning and Clinical Outcomes"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5435-1100","authenticated-orcid":false,"given":"Lola","family":"Gutierrez","sequence":"first","affiliation":[{"name":"Groupe Cardiovasculaire Interventionnel (GCVI), Clinique Pasteur, 31300 Toulouse, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mauro","family":"Boiago","sequence":"additional","affiliation":[{"name":"Groupe Cardiovasculaire Interventionnel (GCVI), Clinique Pasteur, 31300 Toulouse, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2661-3246","authenticated-orcid":false,"given":"Chiara","family":"De Biase","sequence":"additional","affiliation":[{"name":"Groupe Cardiovasculaire Interventionnel (GCVI), Clinique Pasteur, 31300 Toulouse, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Omar","family":"Oliva","sequence":"additional","affiliation":[{"name":"Groupe Cardiovasculaire Interventionnel (GCVI), Clinique Pasteur, 31300 Toulouse, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pietro","family":"Laforgia","sequence":"additional","affiliation":[{"name":"Groupe Cardiovasculaire Interventionnel (GCVI), Clinique Pasteur, 31300 Toulouse, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Souheib","family":"Feliachi","sequence":"additional","affiliation":[{"name":"Groupe Cardiovasculaire Interventionnel (GCVI), Clinique Pasteur, 31300 Toulouse, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alessandro","family":"Beneduce","sequence":"additional","affiliation":[{"name":"Groupe Cardiovasculaire Interventionnel (GCVI), Clinique Pasteur, 31300 Toulouse, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicolas","family":"Dumonteil","sequence":"additional","affiliation":[{"name":"Groupe Cardiovasculaire Interventionnel (GCVI), Clinique Pasteur, 31300 Toulouse, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Didier","family":"Tchetche","sequence":"additional","affiliation":[{"name":"Groupe Cardiovasculaire Interventionnel (GCVI), Clinique Pasteur, 31300 Toulouse, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,11,14]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2789","DOI":"10.1016\/j.jacc.2009.12.068","article-title":"Bicuspid Aortic Valve Disease","volume":"55","author":"Siu","year":"2010","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2691","DOI":"10.1161\/CIRCULATIONAHA.113.007851","article-title":"Bicuspid Aortic Valve","volume":"129","author":"Michelena","year":"2014","journal-title":"Circulation"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"367","DOI":"10.21037\/cdt.2017.05.03","article-title":"Diagnostic accuracy study of routine echocardiography for bicuspid aortic valve: A retrospective study and meta-analysis","volume":"7","author":"Hillebrand","year":"2017","journal-title":"Cardiovasc. Diagn. Ther."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"492","DOI":"10.2459\/JCM.0000000000001134","article-title":"Contemporary management of severe symptomatic bicuspid aortic valve stenosis: The BiTri Registry","volume":"22","author":"Siddiqui","year":"2021","journal-title":"J. Cardiovasc. Med."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1226","DOI":"10.1016\/j.jtcvs.2007.01.039","article-title":"A classification system for the bicuspid aortic valve from 304 surgical specimens","volume":"133","author":"Sievers","year":"2007","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1145","DOI":"10.1016\/j.jcmg.2015.12.022","article-title":"A Bicuspid Aortic Valve Imaging Classification for the TAVR Era","volume":"9","author":"Jilaihawi","year":"2016","journal-title":"JACC Cardiovasc. Imaging"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"e203","DOI":"10.1016\/j.athoracsur.2020.08.119","article-title":"International Consensus Statement on Nomenclature and Classification of the Congenital Bicuspid Aortic Valve and Its Aortopathy, for Clinical, Surgical, Interventional and Research Purposes","volume":"112","author":"Michelena","year":"2021","journal-title":"Ann. Thorac. Surg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1007\/s00392-020-01793-9","article-title":"Predictors of high residual gradient after transcatheter aortic valve replacement in bicuspid aortic valve stenosis","volume":"110","author":"Bugani","year":"2021","journal-title":"Clin. Res. Cardiol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.ijcard.2020.10.050","article-title":"Procedural and clinical outcomes of type 0 versus type 1 bicuspid aortic valve stenosis undergoing trans-catheter valve replacement with new generation devices: Insight from the BEAT international collaborative registry","volume":"325","author":"Ielasi","year":"2021","journal-title":"Int. J. Cardiol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2330","DOI":"10.1016\/j.jacc.2014.09.039","article-title":"Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Disease","volume":"64","author":"Mylotte","year":"2014","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1195","DOI":"10.1016\/j.jacc.2016.06.041","article-title":"Transcatheter Aortic Valve Replacement with Early- and New-Generation Devices in Bicuspid Aortic Valve Stenosis","volume":"68","author":"Yoon","year":"2016","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"e007107","DOI":"10.1161\/CIRCINTERVENTIONS.118.007107","article-title":"Bicuspid Aortic Valve Anatomy and Relationship with Devices: The BAVARD Multicenter Registry","volume":"12","author":"Tchetche","year":"2019","journal-title":"Circ. Cardiovasc. Interv."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/j.ijcard.2020.05.076","article-title":"Supra-annular sizing of transcatheter aortic valve prostheses in raphe-type bicuspid aortic valve disease: The LIRA method","volume":"317","author":"Iannopollo","year":"2020","journal-title":"Int. J. Cardiol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"C233","DOI":"10.1093\/eurheartj\/suac014","article-title":"Update on supra-annular sizing of transcatheter aortic valve prostheses in raphe-type bicuspid aortic valve disease according to the LIRA method","volume":"24","author":"Iannopollo","year":"2022","journal-title":"Eur. Heart J. Suppl."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1016\/j.jcct.2020.01.007","article-title":"Bicuspid aortic valve sizing for transcatheter aortic valve implantation: Development and validation of an algorithm based on multi-slice computed tomography","volume":"14","author":"Petronio","year":"2020","journal-title":"J. Cardiovasc. Comput. Tomogr."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1007\/s40119-021-00223-9","article-title":"Expert Consensus on Sizing and Positioning of SAPIEN 3\/Ultra in Bicuspid Aortic Valves","volume":"10","author":"Blackman","year":"2021","journal-title":"Cardiol. Ther."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"502","DOI":"10.4244\/EIJ-D-23-00021","article-title":"Transcatheter aortic valve implantation with the Evolut platform for bicuspid aortic valve stenosis: The international, multicentre, prospective BIVOLUTX registry","volume":"19","author":"Ziviello","year":"2023","journal-title":"EuroIntervention"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"e008714","DOI":"10.1161\/CIRCINTERVENTIONS.119.008714","article-title":"Balloon Versus Self-Expandable Valve for the Treatment of Bicuspid Aortic Valve Stenosis: Insights From the BEAT International Collaborative Registrys","volume":"13","author":"Mangieri","year":"2020","journal-title":"Circ. Cardiovasc. Interv."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1912","DOI":"10.1007\/s00392-021-01882-3","article-title":"The ACURATE neo2 valve system for transcatheter aortic valve implantation: 30-day and 1-year outcomes","volume":"110","author":"Holzhey","year":"2021","journal-title":"Clin. Res. Cardiol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/j.jacasi.2021.07.012","article-title":"Application of Balloon-Expandable Transcatheter Heart Valve in Bicuspid Aortic Valve","volume":"1","author":"Chen","year":"2021","journal-title":"JACC Asia"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1038\/s41569-022-00734-5","article-title":"Transcatheter aortic valve implantation in patients with bicuspid valve morphology: A roadmap towards standardization","volume":"20","author":"Xiong","year":"2022","journal-title":"Nat. Rev. Cardiol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1018","DOI":"10.1016\/j.jacc.2020.07.005","article-title":"Bicuspid Aortic Valve Morphology and Outcomes After Transcatheter Aortic Valve Replacement","volume":"76","author":"Yoon","year":"2020","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_23","first-page":"524","article-title":"2021 ESC\/EACTS Guidelines for the management of valvular heart disease: Developed by the Task Force for the management of valvular heart disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS)","volume":"75","author":"Vahanian","year":"2022","journal-title":"Rev. Esp. Cardiol."},{"key":"ref_24","first-page":"e35","article-title":"2020 ACC\/AHA Guideline for the Management of Patients With Valvular Heart Disease: Executive Summary: A Report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines","volume":"143","author":"Otto","year":"2021","journal-title":"Circulation"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"2518","DOI":"10.1016\/j.jacc.2020.02.069","article-title":"Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Stenosis","volume":"75","author":"Mentias","year":"2020","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1811","DOI":"10.1016\/j.jcin.2019.06.037","article-title":"Temporal Trends and Outcomes of Transcatheter Versus Surgical Aortic Valve Replacement for Bicuspid Aortic Valve Stenosis","volume":"12","author":"Elbadawi","year":"2019","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2193","DOI":"10.1001\/jama.2019.7108","article-title":"Association Between Transcatheter Aortic Valve Replacement for Bicuspid vs Tricuspid Aortic Stenosis and Mortality or Stroke","volume":"321","author":"Makkar","year":"2019","journal-title":"JAMA"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1749","DOI":"10.1016\/j.jcin.2020.03.022","article-title":"Transcatheter Aortic Valve Replacement in Bicuspid Versus Tricuspid Aortic Valves From the STS\/ACC TVT Registry","volume":"13","author":"Forrest","year":"2020","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/j.jcin.2021.10.027","article-title":"Propensity-Matched 1-Year Outcomes Following Transcatheter Aortic Valve Replacement in Low-Risk Bicuspid and Tricuspid Patients","volume":"15","author":"Deeb","year":"2022","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1016\/j.jcin.2022.01.279","article-title":"The PARTNER 3 Bicuspid Registry for Transcatheter Aortic Valve Replacement in Low-Surgical-Risk Patients","volume":"15","author":"Williams","year":"2022","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"2144","DOI":"10.1016\/j.jcin.2021.07.052","article-title":"Outcomes After Transcatheter Aortic Valve Replacement in Bicuspid Versus Tricuspid Anatomy: A Systematic Review and Meta-Analysis","volume":"14","author":"Montalto","year":"2021","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"2579","DOI":"10.1016\/j.jacc.2017.03.017","article-title":"Outcomes in Transcatheter Aortic Valve Replacement for Bicuspid versus Tricuspid Aortic Valve Stenosis","volume":"69","author":"Yoon","year":"2017","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1016\/j.jcin.2020.02.008","article-title":"Transcatheter Aortic Valve Replacement in Low-Risk Patients with Symptomatic Severe Bicuspid Aortic Valve Stenosis","volume":"13","author":"Waksman","year":"2020","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.amjcard.2020.12.085","article-title":"Meta-Analysis of Transcatheter Aortic Valve Implantation in Patients With Stenotic Bicuspid Versus Tricuspid Aortic Valve","volume":"145","author":"Majmundar","year":"2021","journal-title":"Am. J. Cardiol."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/j.jcin.2020.11.020","article-title":"Optimizing Fluoroscopic Projections for TAVR","volume":"14","author":"Siddiqui","year":"2021","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"S32","DOI":"10.1016\/j.cjca.2020.07.078","article-title":"Cusp Overlap Method For Self-Expanding Transcatheter Aortic Valve Replacement","volume":"36","author":"Aljabbary","year":"2020","journal-title":"Can. J. Cardiol."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1253","DOI":"10.1056\/NEJMoa2204961","article-title":"Cerebral Embolic Protection during Transcatheter Aortic-Valve Replacement","volume":"387","author":"Kapadia","year":"2022","journal-title":"N. Engl. J. Med."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/12\/22\/7074\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T21:22:32Z","timestamp":1760131352000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/12\/22\/7074"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,14]]},"references-count":37,"journal-issue":{"issue":"22","published-online":{"date-parts":[[2023,11]]}},"alternative-id":["jcm12227074"],"URL":"https:\/\/doi.org\/10.3390\/jcm12227074","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,14]]}}}