{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,31]],"date-time":"2026-01-31T02:22:24Z","timestamp":1769826144864,"version":"3.49.0"},"reference-count":55,"publisher":"MDPI AG","issue":"24","license":[{"start":{"date-parts":[[2023,12,10]],"date-time":"2023-12-10T00:00:00Z","timestamp":1702166400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Background: When heart transplantation and myocardial recovery are unlikely, patients presenting with biventricular cardiogenic shock initially treated with extracorporeal membrane oxygenation (ECMO) may benefit from a mechanical support upgrade. In this scenario, a micro-invasive approach is proposed: the combination of the double-lumen ProtekDuo cannula (Livanova, London, UK) and the Impella 5.5 (Abiomed, Danvers, MA) trans-aortic pump that translates into a hybrid BiVAD. Methods: All consecutive ECMO patients presenting with biventricular cardiogenic shock and ineligibility to heart transplantation from August 2022 were prospectively enrolled. The clinical course, procedural details, and in-hospital events were collected via electronic medical records. Results: A total of three patients, who were temporarily not eligible for heart transplantation or durable LVAD due to severe acute pneumonia and right ventricular (RV) dysfunction, were implanted with a hybrid BiVAD. This strategy provided high-flow biventricular support while pulmonary function ameliorated. Moreover, by differentially sustaining the systemic and pulmonary circulation, it allowed for a more adequate reassessment of RV function. All the patients were considered eligible for isolated durable LVAD and underwent less invasive LVAD implantation paired with a planned postoperative RVAD. In all cases, RV function gradually recovered and the RVAD was successfully removed. Conclusions: The Hybrid BiVAD represents an up-to-date micro-invasive mechanical treatment of acute biventricular failure beyond ECMO. Its rationale relies on more physiological circulation across the lungs, the complete biventricular unloading, and the possibility of including an oxygenator in the circuit. Finally, the independent and differential control of pulmonary and systemic flows allows for more accurate RV function evaluation for isolated durable LVAD eligibility reassessment.<\/jats:p>","DOI":"10.3390\/jcm12247604","type":"journal-article","created":{"date-parts":[[2023,12,11]],"date-time":"2023-12-11T14:12:51Z","timestamp":1702303971000},"page":"7604","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Test Bench for Right Ventricular Failure Reversibility: The Hybrid BiVAD Concept"],"prefix":"10.3390","volume":"12","author":[{"given":"Vincenzo","family":"Tarzia","sequence":"first","affiliation":[{"name":"Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, 35121 Padua, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4472-6287","authenticated-orcid":false,"given":"Matteo","family":"Ponzoni","sequence":"additional","affiliation":[{"name":"Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, 35121 Padua, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4625-1134","authenticated-orcid":false,"given":"Demetrio","family":"Pittarello","sequence":"additional","affiliation":[{"name":"Institute of Anesthesia and Intensive Care, Padua University Hospital, 35128 Padua, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6261-699X","authenticated-orcid":false,"given":"Gino","family":"Gerosa","sequence":"additional","affiliation":[{"name":"Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, 35121 Padua, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,12,10]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/j.jtcvs.2015.02.043","article-title":"Extracorporeal Life Support in Cardiogenic Shock: Impact of Acute versus Chronic Etiology on Outcome","volume":"150","author":"Tarzia","year":"2015","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1097\/MAT.0b013e31821f2116","article-title":"Levitronix CentriMag Third-Generation Magnetically Levitated Continuous Flow Pump as Bridge to Solution","volume":"57","author":"Loforte","year":"2011","journal-title":"ASAIO J."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Tarzia, V., Bagozzi, L., Ponzoni, M., Bortolussi, G., Folino, G., Bianco, R., Zanella, F., Bottio, T., and Gerosa, G. (2022). How to Optimize ECLS Results beyond Ventricular Unloading: From ECMO to CentriMag\u00ae EVAD. J. Clin. Med., 11.","DOI":"10.3390\/jcm11154605"},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Chen, J.-L., Tsai, Y.-T., Lin, C.-Y., Ke, H.-Y., Lin, Y.-C., Yang, H.-Y., Liu, C.-T., Sung, S.-Y., Chang, J.-T., and Wang, Y.-H. (2022). Extracorporeal Life Support and Temporary CentriMag Ventricular Assist Device to Salvage Cardiogenic-Shock Patients Suffering from Prolonged Cardiopulmonary Resuscitation. J. Clin. Med., 11.","DOI":"10.3390\/jcm11133773"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1007\/s12055-020-01060-6","article-title":"Outcome of CentriMagTM Extracorporeal Mechanical Circulatory Support Use in Critical Cardiogenic Shock (INTERMACS 1) Patients","volume":"36","author":"Mehta","year":"2020","journal-title":"Indian J. Thorac. Cardiovasc. Surg."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1177\/0267659114563947","article-title":"Survival on Biventricular Mechanical Support with the Centrimag \u00ae as a Bridge to Decision: A Single-Center Risk Stratification","volume":"30","author":"Mohamedali","year":"2015","journal-title":"Perfusion"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1016\/j.jacc.2018.10.085","article-title":"Left Ventricular Unloading During Extracorporeal Membrane Oxygenation in Patients with Cardiogenic Shock","volume":"73","author":"Russo","year":"2019","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1177\/0267659118794112","article-title":"Left Ventricular Unloading during Veno-Arterial ECMO: A Review of Percutaneous and Surgical Unloading Interventions","volume":"34","author":"Donker","year":"2019","journal-title":"Perfusion"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"e013586","DOI":"10.1161\/JAHA.119.013586","article-title":"Left Ventricular Unloading Increases the Coronary Collateral Flow Index Before Reperfusion and Reduces Infarct Size in a Swine Model of Acute Myocardial Infarction","volume":"8","author":"Briceno","year":"2019","journal-title":"J. Am. Heart Assoc."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1016\/j.hlc.2011.12.003","article-title":"Extra Corporeal Membrane Oxygenation as Right Heart Support Following Left Ventricular Assist Device Placement: A New Cannulation Technique","volume":"21","author":"Soto","year":"2012","journal-title":"Hear. Lung Circ."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1110","DOI":"10.1097\/MAT.0000000000001146","article-title":"Balanced Biventricular Assist Versus Extracorporeal Membrane Oxygenation in Cardiac Arrest","volume":"66","author":"Packer","year":"2020","journal-title":"ASAIO J."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1002\/ehf2.12274","article-title":"Full Percutaneous Biventricular Support with Two Impella Pumps: The Bi-Pella Approach","volume":"5","author":"Pappalardo","year":"2018","journal-title":"ESC Hear. Fail."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1586\/17434440.2016.1154454","article-title":"Biventricular Mechanical Support Devices\u2014Clinical Perspectives","volume":"13","author":"Shehab","year":"2016","journal-title":"Expert Rev. Med. Devices"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1002\/ccd.28830","article-title":"Percutaneous Impella RP Use for Refractory Right Heart Failure in Adolescents and Young Adults\u2014A Multicenter U.S. Experience","volume":"96","author":"Qureshi","year":"2020","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"ezac084","DOI":"10.1093\/ejcts\/ezac084","article-title":"Microinvasive Cardiac Surgery: When Less Is More-\u2019render to Caesar the Things That Are Caesar\u2019s; and to the Surgeon the Things That Are the Surgeons\u201d","volume":"62","author":"Gerosa","year":"2022","journal-title":"Eur. J. Cardio-Thorac. Surg."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1097\/MOT.0000000000000120","article-title":"Terminal Heart Failure","volume":"19","author":"Kirklin","year":"2014","journal-title":"Curr. Opin. Organ Transplant."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2003","DOI":"10.1002\/ehf2.12874","article-title":"Heart Transplantation Management in Northern Italy during COVID-19 Pandemic: Single-Centre Experience","volume":"7","author":"Fiocco","year":"2020","journal-title":"ESC Heart Fail."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Tarzia, V., Ponzoni, M., Pittarello, D., and Gerosa, G. (2022). Planned Combo Strategy for LVAD Implantation in ECMO Patients: A Proof of Concept to Face Right Ventricular Failure. J. Clin. Med., 11.","DOI":"10.3390\/jcm11237062"},{"key":"ref_19","first-page":"2676591211024817","article-title":"Outcome of Right Ventricular Assist Device Implantation Following Left Ventricular Assist Device Implantation: Systematic Review and Meta-Analysis","volume":"37","author":"Reid","year":"2021","journal-title":"Perfusion"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"828","DOI":"10.1093\/icvts\/ivw409","article-title":"Contemporary Outcome of Unplanned Right Ventricular Assist Device for Severe Right Heart Failure after Continuous-Flow Left Ventricular Assist Device Insertion","volume":"24","author":"Yoshioka","year":"2017","journal-title":"Interact. Cardiovasc. Thorac. Surg."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"e008706","DOI":"10.1161\/CIRCHEARTFAILURE.121.008706","article-title":"Right Heart Failure Following Left Ventricular Device Implantation: Natural History, Risk Factors, and Outcomes: An Analysis of the STS INTERMACS Database","volume":"15","author":"Kapelios","year":"2022","journal-title":"Circ. Heart Fail."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1016\/j.athoracsur.2013.01.086","article-title":"Less Invasive Surgical and Perfusion Technique for Implantation of the Jarvik 2000 Left Ventricular Assist Device","volume":"96","author":"Gerosa","year":"2013","journal-title":"Ann. Thorac. Surg."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2486","DOI":"10.1111\/aor.14368","article-title":"Technology and Technique for Left Ventricular Assist Device Optimization: A Bi-Tech Solution","volume":"46","author":"Tarzia","year":"2022","journal-title":"Artif. Organs"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.jtcvs.2015.09.107","article-title":"From Bench to Bedside: Can the Improvements in Left Ventricular Assist Device Design Mitigate Adverse Events and Increase Survival?","volume":"151","author":"Tarzia","year":"2016","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"10752","DOI":"10.1038\/s41598-020-67622-1","article-title":"The Biological Age of the Heart Is Consistently Younger than Chronological Age","volume":"10","author":"Pavanello","year":"2020","journal-title":"Sci. Rep."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"101554","DOI":"10.1016\/j.cpcardiol.2022.101554","article-title":"Prognosticating Mortality of Primary Cardiogenic Shock Requiring Extracorporeal Life Support: The RESCUE Score","volume":"48","author":"Tarzia","year":"2022","journal-title":"Curr. Probl. Cardiol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1002\/ejhf.850","article-title":"Modalities and Effects of Left Ventricle Unloading on Extracorporeal Life Support: A Review of the Current Literature","volume":"19","author":"Meani","year":"2017","journal-title":"Eur. J. Heart Fail."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1676","DOI":"10.21037\/jtd.2019.03.29","article-title":"Left Ventricular Distension and Venting Strategies for Patients on Venoarterial Extracorporeal Membrane Oxygenation","volume":"11","author":"Cevasco","year":"2019","journal-title":"J. Thorac. Dis."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1097\/MAT.0000000000001930","article-title":"Veno-Pulmonary Arterial Extracorporeal Membrane Oxygenation in Severe Acute Respiratory Distress Syndrome: Should We Consider Mechanical Support of the Pulmonary Circulation from the Outset?","volume":"69","author":"Zochios","year":"2023","journal-title":"ASAIO J."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"e006670","DOI":"10.1161\/JAHA.117.006670","article-title":"Acute Biventricular Mechanical Circulatory Support for Cardiogenic Shock","volume":"6","author":"Kuchibhotla","year":"2017","journal-title":"J. Am. Heart Assoc."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1111\/jocs.14283","article-title":"ECPELLA 2.0\u2014Minimally Invasive Biventricular Groin-free Full Mechanical Circulatory Support with Impella 5.0\/5.5 Pump and ProtekDuo Cannula as a Bridge-to-bridge Concept: A First-in-man Method Description","volume":"35","author":"Ruhparwar","year":"2020","journal-title":"J. Card. Surg."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1016\/j.surg.2022.10.007","article-title":"Peripherally Inserted Concomitant Surgical Right and Left Ventricular Support, the Propella, Is Associated with Low Rates of Limb Ischemia, with Mortality Comparable with Peripheral Venoarterial Extracorporeal Membrane Oxygenation","volume":"173","author":"Walsh","year":"2022","journal-title":"Surgery"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1016\/j.healun.2005.11.458","article-title":"Levitronix as a Short-Term Salvage Treatment for Primary Graft Failure After Heart Transplantation","volume":"25","author":"Santise","year":"2006","journal-title":"J. Hear. Lung Transplant."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1016\/j.jtcvs.2007.01.085","article-title":"Experience with the Levitronix CentriMag Circulatory Support System as a Bridge to Decision in Patients with Refractory Acute Cardiogenic Shock and Multisystem Organ Failure","volume":"134","author":"John","year":"2007","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/j.healun.2007.10.015","article-title":"The Papworth Experience with the Levitronix CentriMag Ventricular Assist Device","volume":"27","author":"Shuhaiber","year":"2008","journal-title":"J. Hear. Lung Transplant."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/j.jtcvs.2009.03.018","article-title":"Bridging Patients after Salvage from Bridge to Decision Directly to Transplant by Means of Prolonged Support with the CentriMag Short-Term Centrifugal Pump","volume":"138","author":"Birks","year":"2009","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1016\/j.jtcvs.2010.03.046","article-title":"Outcomes of a Multicenter Trial of the Levitronix CentriMag Ventricular Assist System for Short-Term Circulatory Support","volume":"141","author":"John","year":"2011","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"e310","DOI":"10.1093\/ejcts\/ezt415","article-title":"CentriMag(R) Short-Term Ventricular Assist as a Bridge to Solution in Patients with Advanced Heart Failure: Use beyond 30 Days","volume":"44","author":"Mohite","year":"2013","journal-title":"Eur. J. Cardio-Thorac. Surg."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1007\/s12265-013-9521-9","article-title":"Acute Mechanical Circulatory Support for Fulminant Myocarditis Complicated by Cardiogenic Shock","volume":"7","author":"Mody","year":"2014","journal-title":"J. Cardiovasc. Transl. Res."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1055","DOI":"10.1093\/ejcts\/ezx189","article-title":"Minimally Invasive CentriMag Ventricular Assist Device Support Integrated with Extracorporeal Membrane Oxygenation in Cardiogenic Shock Patients: A Comparison with Conventional CentriMag Biventricular Support Configuration","volume":"52","author":"Takeda","year":"2017","journal-title":"Eur. J. Cardio-Thorac. Surg."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1620","DOI":"10.1093\/eurheartj\/eht020","article-title":"Percutaneous Biventricular Cardiac Assist Device in Cardiogenic Shock","volume":"34","author":"Hunziker","year":"2013","journal-title":"Eur. Heart J."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1006","DOI":"10.1161\/CIRCHEARTFAILURE.115.002374","article-title":"First Successful Use of 2 Axial Flow Catheters for Percutaneous Biventricular Circulatory Support as a Bridge to a Durable Left Ventricular Assist Device","volume":"8","author":"Kapur","year":"2015","journal-title":"Circ. Hear. Fail."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"e003636","DOI":"10.1161\/CIRCINTERVENTIONS.116.003636","article-title":"Biventricular Circulatory Support Using 2 Axial Flow Catheters for Cardiogenic Shock Without the Need for Surgical Vascular Access","volume":"9","author":"Aghili","year":"2016","journal-title":"Circ. Cardiovasc. Interv."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"E343","DOI":"10.1002\/ccd.27103","article-title":"Biventricular Impella Placement via Complete Venous Access","volume":"93","author":"Kamioka","year":"2019","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/j.hrtlng.2018.03.009","article-title":"Percutaneous Biventricular Impella Support in Therapy-Refractory Cardiogenic Shock","volume":"47","author":"Chiu","year":"2018","journal-title":"Hear. Lung"},{"key":"ref_46","first-page":"4591250","article-title":"Hemodynamic Support Using Percutaneous Transfemoral Impella 5.0 and Impella RP for Refractory Cardiogenic Shock","volume":"2019","author":"Dalal","year":"2019","journal-title":"Case Rep. Cardiol."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1111\/aor.13558","article-title":"Biventricular Impella Use in Pediatric Patients with Severe Graft Dysfunction from Acute Rejection after Heart Transplantation","volume":"44","author":"Ankola","year":"2020","journal-title":"Artif. Organs"},{"key":"ref_48","first-page":"312","article-title":"BiPella: Mini Review on a Novel Method to Treat Cardiogenic Shock Patients","volume":"37","author":"Karaaslan","year":"2021","journal-title":"Acta Cardiol. Sin."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"6676339","DOI":"10.1155\/2021\/6676339","article-title":"Biventricular Impella (Bi-Pella) in Refractory Cardiogenic Shock: The First Case from the Middle East","volume":"2021","author":"Almejren","year":"2021","journal-title":"Case Rep. Med."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1016\/j.recesp.2021.01.011","article-title":"First Experience of Percutaneous Bi-Pella in Spain","volume":"74","author":"Puerto","year":"2021","journal-title":"Rev. Esp. Cardiol."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"1104","DOI":"10.1002\/ccr3.3657","article-title":"Cardiogenic Shock in Thyroid Storm: A Biventricular Impella (Bi-Pella) Approach","volume":"9","author":"Caruso","year":"2021","journal-title":"Clin. Case Rep."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"ytab040","DOI":"10.1093\/ehjcr\/ytab040","article-title":"Successful Resuscitation of Acute Cardiogenic Shock Presenting as Ventricular Fibrillation via Bipella Approach: A Case Report","volume":"5","author":"Zoltowska","year":"2021","journal-title":"Eur. Hear. J. Case Rep."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"ytac373","DOI":"10.1093\/ehjcr\/ytac373","article-title":"Full Myocardial Recovery Following COVID-19 Fulminant Myocarditis after Biventricular Mechanical Support with BiPella: A Case Report","volume":"6","author":"Ajello","year":"2022","journal-title":"Eur. Hear. J. Case Rep."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1007\/s11748-020-01571-4","article-title":"Impella CP and ProtekDuo as a Bridge to Recovery Following Surgical Revascularization Complicated by Electrical Storm","volume":"69","author":"Chivasso","year":"2021","journal-title":"Gen. Thorac. Cardiovasc. Surg."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"2113","DOI":"10.1016\/j.athoracsur.2021.01.047","article-title":"The Rules of Medical Innovation: Experience, Creativity, and Courage: Reply","volume":"112","author":"Tarzia","year":"2021","journal-title":"Ann. Thorac. Surg."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/12\/24\/7604\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T21:36:14Z","timestamp":1760132174000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/12\/24\/7604"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,10]]},"references-count":55,"journal-issue":{"issue":"24","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["jcm12247604"],"URL":"https:\/\/doi.org\/10.3390\/jcm12247604","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,10]]}}}