{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T18:12:17Z","timestamp":1785521537148,"version":"3.56.0"},"reference-count":41,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2023,12,31]],"date-time":"2023-12-31T00:00:00Z","timestamp":1703980800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>To demonstrate the results of ray tracing higher- and lower-order aberrations in pseudophakic eyes with rotationally asymmetrical segment multifocal lenses, total high- and low-order aberrations, measured by root mean square value (RMS), refraction, uncorrected distance and uncorrected near visual acuity (UCDVA and UCNVA), and tear break-up time, were measured at scotopic size in 42 eyes of patients implanted with bifocal refractive Mplus15\/Mplus30 IOL with +1.5 dpt near addition (42 eyes of patients implanted with Mplus15)\/+3.0 dpt near addition (91 eyes of patients implanted with Mplus30), and 107 eyes of control group. No significant differences were noticed between the examined groups concerning UCDVA, UCNVA, and tear break-up time (p &lt; 0.001). Coma and total high-order aberrations were significantly higher for the Mplus30 lens in comparison to the Mplus15 lens and the control group (Coma, Trefoil p &lt; 0.001, Secondary Astigmatism p = 0.002). The spherical aberrations were significantly higher in the lower-addition lens (p = 0.016) in comparison to the control group and to the higher-addition lens group (p &lt; 0.001). Both intraocular lens models were successful at reaching refractive aim, good distance, and near function with the lower higher-order aberrations for the low-addition lens.<\/jats:p>","DOI":"10.3390\/jcm13010239","type":"journal-article","created":{"date-parts":[[2023,12,31]],"date-time":"2023-12-31T06:00:21Z","timestamp":1704002421000},"page":"239","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Comparative Analysis of the Visual, Refractive and Aberrometric Outcome with the Use of 2 Intraocular Refractive Segment Multifocal Lenses"],"prefix":"10.3390","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5733-5923","authenticated-orcid":false,"given":"Bart\u0142omiej","family":"Markuszewski","sequence":"first","affiliation":[{"name":"Chair and Clinical Department of Ophthalmology, Faculty of Medical Sciences, Zabrze Medical University of Silesia, 40-760 Katowice, Poland"},{"name":"Wroc\u0142awskie Centrum Okulistyczne, 50-231 Wroc\u0142aw, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7295-4936","authenticated-orcid":false,"given":"Adam","family":"Wyl\u0119ga\u0142a","sequence":"additional","affiliation":[{"name":"Chair and Clinical Department of Ophthalmology, Faculty of Medical Sciences, Zabrze Medical University of Silesia, 40-760 Katowice, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"N\u00f3ra","family":"Szentm\u00e1ry","sequence":"additional","affiliation":[{"name":"Dr. Rofl M. Schwiete Center for Limbal Stem Cell and Aniridia Research, Saarland University, 66424 Homburg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Achim","family":"Langenbucher","sequence":"additional","affiliation":[{"name":"Department of Experimental Ophthalmology, Saarland University, 66424 Homburg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna","family":"Markuszewska","sequence":"additional","affiliation":[{"name":"Wroc\u0142awskie Centrum Okulistyczne, 50-231 Wroc\u0142aw, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6707-5790","authenticated-orcid":false,"given":"Edward","family":"Wyl\u0119ga\u0142a","sequence":"additional","affiliation":[{"name":"Chair and Clinical Department of Ophthalmology, Faculty of Medical Sciences, Zabrze Medical University of Silesia, 40-760 Katowice, Poland"},{"name":"Department of Ophthalmology, District Railway Hospital, 40-760 Katowice, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,12,31]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1016\/j.survophthal.2017.03.005","article-title":"Multifocal intraocular lenses: An overview","volume":"62","author":"Alio","year":"2017","journal-title":"Surv. Ophthalmol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"943","DOI":"10.1055\/a-1111-9380","article-title":"Aktuelle \u00dcbersicht: Multifokale Linsen und Extended-Depth-of-Focus-Intraokularlinsen [Current Review: Multifocal Intraocular Lenses and Extended Depth of Focus Intraocular Lenses]","volume":"237","author":"Breyer","year":"2020","journal-title":"Klin. Monbl. Augenheilkd."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Niazi, S., Gatzioufas, Z., Dhubhghaill, S.N., Moshirfar, M., Faramarzi, A., Mohammadi, F., Kheiri, B., Peyman, A., Heidari, M., and Doroodgar, F. (2023). Association of Patient Satisfaction with Cataract Grading in Five Types of Multifocal IOLs. Adv. Ther., Published online ahead of print.","DOI":"10.1007\/s12325-023-02698-5"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/j.optom.2021.05.002","article-title":"Visual and satisfaction results with implantation of the trifocal Panoptix\u00ae intraocular lens in cataract surgery","volume":"15","author":"Galvis","year":"2022","journal-title":"J. Optom."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"2553","DOI":"10.1007\/s10792-020-01435-z","article-title":"Comparison of visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses","volume":"40","author":"Kirkiewicz","year":"2020","journal-title":"Int. Ophthalmol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1097\/j.jcrs.0000000000001195","article-title":"Long-term trifocal toric intraocular lens outcomes in Asian eyes after cataract surgery","volume":"49","author":"Ang","year":"2023","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.ajo.2023.01.024","article-title":"Extended Depth of Focus Versus Trifocal for Intraocular Lens Implantation: An Updated Systematic Review and Meta-Analysis","volume":"251","author":"Karam","year":"2023","journal-title":"Am. J. Ophthalmol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"569","DOI":"10.3928\/1081597X-20091030-02","article-title":"LASIK outcomes following multifocal and monofocal intraocular lens implantation","volume":"26","author":"Pinero","year":"2010","journal-title":"J. Refract. Surg."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1721","DOI":"10.1016\/j.jcrs.2016.10.016","article-title":"Comparison of the visual performance and quality of vision with combined symmetrical inferonasal near addition versus inferonasal and superotemporal placement of rotationally asymmetric refractive multifocal intraocular lenses","volume":"42","author":"McNeely","year":"2016","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"13117","DOI":"10.1038\/s41598-019-49524-z","article-title":"One-year clinical evaluation of rotationally asymmetric multifocal intraocular lens with +1.5 diopters near addition","volume":"9","author":"Oshika","year":"2019","journal-title":"Sci. Rep."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.jcrs.2006.10.068","article-title":"Spherical aberration and coma with an aspherical and a spherical intraocular lens in normal age-matched eyes","volume":"33","author":"Bellucci","year":"2007","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1055\/s-2008-1034782","article-title":"Image properties of spherical as aspheric intraocular lenses","volume":"214","author":"Werner","year":"1999","journal-title":"Klin. Mon. Augenheilkd."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"280","DOI":"10.3928\/1081597X-20080301-10","article-title":"Problems in the measurement of wavefront aberration for eyes implanted with diffractive bifocal and multifocal intraocular lenses","volume":"24","author":"Charman","year":"2008","journal-title":"J. Refract. Surg."},{"key":"ref_14","first-page":"569","article-title":"Objective Optical Quality With Multifocal Intraocular Lenses Should Stop to Be Used or Cautiously Interpreted","volume":"11","year":"2022","journal-title":"Asia Pac. J. Ophthalmol."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Vega, F., Faria-Ribeiro, M., Armengol, J., and Mill\u00e1n, M.S. (2023). Pitfalls of Using NIR-Based Clinical Instruments to Test Eyes Implanted with Diffractive Intraocular Lenses. Diagnostics, 13.","DOI":"10.3390\/diagnostics13071259"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"D\u2019Oria, F., Scotti, G., Sborgia, A., Boscia, F., and Alessio, G. (2023). How Reliable Is Pyramidal Wavefront-Based Sensor Aberrometry in Measuring the In Vivo Optical Behaviour of Multifocal IOLs?. Sensors, 23.","DOI":"10.3390\/s23073534"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/j.athoracsur.2006.01.084","article-title":"Ethical process in human research published in thoracic surgery journals","volume":"82","author":"Block","year":"2006","journal-title":"Ann. Thorac. Surg."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Cione, F., De Bernardo, M., Gioia, M., Oliviero, M., Santoro, A.G., Caputo, A., Capasso, L., Pagliarulo, S., and Rosa, N. (2023). A No-History Multi-Formula Approach to Improve the IOL Power Calculation after Laser Refractive Surgery: Preliminary Results. J. Clin. Med., 12.","DOI":"10.3390\/jcm12082890"},{"key":"ref_19","unstructured":"Auffarth, G. (2022, December 11). Letnis Mplus: An Innovative Multifocal Lens Technology. CRSTEurope 2010. Available online: http:\/\/crstodayeurope.com\/articles\/2010-feb\/lentis-mplus-an-innovative-multifocal-lens-technology."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2427","DOI":"10.1007\/s40123-023-00740-x","article-title":"Preoperative Treatment of Meibomian Gland Dysfunction with a Vectored Thermal Pulsation System Prior to Extended Depth of Focus IOL Implantation","volume":"12","author":"Matossian","year":"2023","journal-title":"Ophthalmol. Ther."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1016\/j.jcrs.2015.10.069","article-title":"Scheimpflug lens densitometry and ocular wavefront aberrations in patients with mild nuclear cataract","volume":"42","author":"Lopes","year":"2016","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"942","DOI":"10.1016\/j.jcrs.2007.11.057","article-title":"Clinical outcomes and intraocular optical quality of a diffractive multifocal intraocular lens with asymmetrical light distribution","volume":"34","author":"Alio","year":"2008","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1235","DOI":"10.1016\/j.jcrs.2007.03.034","article-title":"Mont es-Mic o R. Prospective visual evaluation of apodized diffractive intraocular lenses","volume":"33","author":"Alfonso","year":"2007","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1468","DOI":"10.1016\/j.jcrs.2008.05.042","article-title":"Microincision multifocal intraocular lens with and without a capsular tension ring; optical quality and clinical outcomes","volume":"34","author":"Alio","year":"2008","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1016\/j.jcrs.2016.01.014","article-title":"Efficacy and safety of multifocal intraocular lenses following cataract and refractive lens exchange: Metaanalysis of peer-reviewed publications","volume":"42","author":"Rosen","year":"2016","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1007\/s004170100348","article-title":"Patient satisfaction after implantation of diffractive designed multifocal intraocular lenses in dependence on objective parameters","volume":"239","author":"Walkow","year":"2001","journal-title":"Graefe Arch. Clin. Exp. Ophthalmol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1016\/S0886-3350(02)01648-6","article-title":"Distance and near contrast sensitivity function after multifocal intraocular lens implantation","volume":"29","author":"Alio","year":"2003","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1016\/j.jcrs.2017.01.025","article-title":"Visual outcomes and patient satisfaction 3 and 12 months after implantation of a refractive rotationally asymmetric multifocal intraocular lens","volume":"43","author":"McNeely","year":"2017","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1709","DOI":"10.1007\/s10792-017-0652-x","article-title":"Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens","volume":"38","author":"Pedrotti","year":"2018","journal-title":"Int. Ophthalmol."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1097\/ICL.0000000000000314","article-title":"Visual outcome and Patient Satisfaction of low-power-added multifocal intraocular lens","volume":"44","author":"Kim","year":"2018","journal-title":"Eye Contact Lens"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1280","DOI":"10.1016\/j.ophtha.2017.03.033","article-title":"Functional Magnetic Resonance Imaging to Assess the Neurobehavioral Impact of Dysphotopsia with Multifocal Intraocular Lenses","volume":"124","author":"Rosa","year":"2017","journal-title":"Ophthalmology"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1016\/j.jcrs.2007.10.031","article-title":"Sources of error in intraocular lens power calculation","volume":"34","author":"Norrby","year":"2008","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Langenbucher, A., Szentm\u00e1ry, N., Cayless, A., Bolz, M., Hoffmann, P., and Wendelstein, J. (2023). Prediction of spectacle refraction uncertainties with discrete IOL power steps and manufacturing tolerances according to ISO using a Monte Carlo model. Br. J. Ophthalmol., 1\u20138.","DOI":"10.1136\/bjo-2023-323921"},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Langenbucher, A., Hoffmann, P., Cayless, A., Bolz, M., Wendelstein, J., and Szentm\u00e1ry, N. (2023). Impact of uncertainties in biometric parameters on intraocular lens power formula predicted refraction using a Monte-Carlo simulation. Acta Ophthalmol., 1\u201311.","DOI":"10.1111\/aos.15726"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1935","DOI":"10.1016\/j.jcrs.2008.06.036","article-title":"Factors related to the degree of success in achieving target refraction in cataract surgery: Swedish National Cataract Register study","volume":"34","author":"Kugelberg","year":"2008","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1016\/j.jcrs.2017.07.006","article-title":"Pursuing perfection in IOL calculations. II. Measurement foibles: Measurement errors, validation criteria, IOL constants, and lane length","volume":"43","author":"Hill","year":"2017","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"D\u2019Oria, F., Nowrouzi, A., Alio del Barrio, J.L., Versaci, F., and Alio, J.L. (2021). Retinal Optical Quality of Multifocal Refractive and Monofocal Intraocular Lenses. Photonics, 8.","DOI":"10.3390\/photonics8120559"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1186\/s40662-021-00258-y","article-title":"Retinal image quality with multifocal, EDoF.; and accommodative intraocular lenses as studied by piramidal aberrometry","volume":"8","author":"Alio","year":"2010","journal-title":"Eye Vis."},{"key":"ref_39","unstructured":"Ali\u00f3, J.L., and Pikkel, J. (2014). Essentials in Ophthalmology, Springer International Publishing."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1159\/000100933","article-title":"Symptomatic dry eye treatment with autologous platelet-rich plasma","volume":"39","author":"Alio","year":"2007","journal-title":"Ophthalmic. Res."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"e87","DOI":"10.1016\/j.ophtha.2020.05.017","article-title":"Re: Turnbull et al.: Methods for intraocular lens power calculation in cataract surgery after radial keratotomy (Ophthalmology. 2020;127:45-51)","volume":"127","author":"Cione","year":"2020","journal-title":"Ophthalmology"}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/13\/1\/239\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T21:45:06Z","timestamp":1760132706000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/13\/1\/239"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,31]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,1]]}},"alternative-id":["jcm13010239"],"URL":"https:\/\/doi.org\/10.3390\/jcm13010239","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,31]]}}}