{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T19:56:51Z","timestamp":1775764611077,"version":"3.50.1"},"reference-count":25,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2024,2,18]],"date-time":"2024-02-18T00:00:00Z","timestamp":1708214400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Background: Implant subsidence is recognized as a complication of interbody stabilization, although its relevance remains ambiguous, particularly in terms of relating the effect of the position and depth of subsidence on the clinical outcome of the procedure. This study aimed to evaluate how implant positioning and size influence the incidence and degree of subsidence and to examine their implications for clinical outcomes. Methods: An observational study of 94 patients (157 levels) who underwent ACDF was conducted. Radiological parameters (implant position, implant height, vertebral body height, segmental height and intervertebral height) were assessed. Clinical outcomes were evaluated using the Visual Analogue Scale (VAS) and Neck Disability Index (NDI). Subsidence was evaluated in groups according to its degree, and statistical analyses were performed. Results: The findings revealed that implant-to-endplate ratio and implant height were significant risk factors associated with the incidence and degree of subsidence. The incidence of subsidence varied as follows: 34 cases (41.5%) exhibited displacement of the implant into the adjacent endplate by 2\u20133 mm, 32 cases (39%) by 3\u20134 mm, 16 cases (19.5%) by \u22654 mm and 75 (47.8%) cases exhibited no subsidence. Conclusions: The findings underscore that oversized or undersized implants relative to the disc space or endplate length elevate the risk and severity of subsidence.<\/jats:p>","DOI":"10.3390\/jcm13041151","type":"journal-article","created":{"date-parts":[[2024,2,19]],"date-time":"2024-02-19T03:18:38Z","timestamp":1708312718000},"page":"1151","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Impact of Implant Size and Position on Subsidence Degree after Anterior Cervical Discectomy and Fusion: Radiological and Clinical Analysis"],"prefix":"10.3390","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6687-1517","authenticated-orcid":false,"given":"Adam","family":"B\u0119benek","sequence":"first","affiliation":[{"name":"Department of Orthopaedics and Traumatology, with Spinal Surgery Ward, Scanmed\u2014St. Raphael Hospital, 30693 Cracow, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5109-4970","authenticated-orcid":false,"given":"Maciej","family":"Dominiak","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, with Spinal Surgery Ward, Scanmed\u2014St. Raphael Hospital, 30693 Cracow, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-9466-4935","authenticated-orcid":false,"given":"Grzegorz","family":"Karpi\u0144ski","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, with Spinal Surgery Ward, Scanmed\u2014St. Raphael Hospital, 30693 Cracow, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1421-2050","authenticated-orcid":false,"given":"Tomasz","family":"Pawe\u0142czyk","sequence":"additional","affiliation":[{"name":"Department of Affective and Psychotic Disorders, Medical University of Lodz, 92216 Lodz, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0673-1480","authenticated-orcid":false,"given":"Bartosz","family":"Godlewski","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, with Spinal Surgery Ward, Scanmed\u2014St. Raphael Hospital, 30693 Cracow, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2024,2,18]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"602","DOI":"10.3171\/jns.1958.15.6.0602","article-title":"The Anterior Approach for Removal of Ruptured Cervical Disks","volume":"15","author":"Cloward","year":"1958","journal-title":"J. Neurosurg."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"669","DOI":"10.4103\/ajns.AJNS_313_20","article-title":"Anterior Approach to the Cervical Spine: Elegance Lies in Its Simplicity","volume":"16","author":"Arumalla","year":"2021","journal-title":"Asian J. Neurosurg."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"2016","DOI":"10.1016\/j.spinee.2015.05.010","article-title":"Pseudoarthrosis Rates in Anterior Cervical Discectomy and Fusion: A Meta-Analysis","volume":"15","author":"Shriver","year":"2015","journal-title":"Spine J."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Veronesi, F., Sartori, M., Griffoni, C., Valacco, M., Tedesco, G., Davassi, P.F., Gasbarrini, A., Fini, M., and Barbanti Brodano, G. (2022). Complications in Spinal Fusion Surgery: A Systematic Review of Clinically Used Cages. J. Clin. Med., 11.","DOI":"10.3390\/jcm11216279"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"531","DOI":"10.4184\/asj.2014.8.4.531","article-title":"Current Concepts of Anterior Cervical Discectomy and Fusion: A Review of Literature","volume":"8","author":"Song","year":"2014","journal-title":"Asian Spine J."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"100","DOI":"10.25259\/SNI-191-2019","article-title":"A Review of Complication Rates for Anterior Cervical Diskectomy and Fusion (ACDF)","volume":"10","author":"Epstein","year":"2019","journal-title":"Surg. Neurol. Int."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1007\/s00701-018-3490-3","article-title":"Incidence and Clinical Relevance of Cage Subsidence in Anterior Cervical Discectomy and Fusion: A Systematic Review","volume":"160","author":"Noordhoek","year":"2018","journal-title":"Acta Neurochir."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1177\/2192568220963061","article-title":"Does Graft Position Affect Subsidence after Anterior Cervical Discectomy and Fusion?","volume":"12","author":"Jang","year":"2022","journal-title":"Glob. Spine J."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1007\/s10143-017-0850-z","article-title":"Cage Deviation in the Subaxial Cervical Spine in Relation to Implant Position in the Sagittal Plane","volume":"41","author":"Mende","year":"2018","journal-title":"Neurosurg. Rev."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1097\/BSD.0000000000000843","article-title":"Factors Influencing Interbody Cage Subsidence Following Anterior Cervical Discectomy and Fusion","volume":"32","author":"Igarashi","year":"2019","journal-title":"Clin. Spine Surg."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1007\/s00701-015-2630-2","article-title":"Clinical and Radiological Outcome after Anterior Cervical Discectomy and Fusion with Stand-Alone Empty Polyetheretherketone (PEEK) Cages","volume":"158","author":"Shiban","year":"2016","journal-title":"Acta Neurochir."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1501","DOI":"10.1007\/s00701-022-05217-7","article-title":"PEEK versus Titanium-Coated PEEK Cervical Cages: Fusion Rate","volume":"164","author":"Godlewski","year":"2022","journal-title":"Acta Neurochir."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Godlewski, B., Bebenek, A., Dominiak, M., Karpinski, G., Cieslik, P., and Pawelczyk, T. (2022). Subsidence Following Cervical Discectomy and Implant-to-Bone Ratio. BMC Musculoskelet. Disord., 23.","DOI":"10.1186\/s12891-022-05698-8"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"447","DOI":"10.3171\/spi.2006.4.6.447","article-title":"Subsidence of the Wing Titanium Cage after Anterior Cervical Interbody Fusion: 2-Year Follow-up Study","volume":"4","author":"Schmieder","year":"2006","journal-title":"J. Neurosurg. Spine"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/BSD.0b013e31825bd26d","article-title":"Impact of Subsidence on Clinical Outcomes and Radiographic Fusion Rates in Anterior Cervical Discectomy and Fusion: A Systematic Review","volume":"27","author":"Karikari","year":"2014","journal-title":"J. Spinal Disord. Tech."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Cabraja, M., Oezdemir, S., Koeppen, D., and Kroppenstedt, S. (2012). Anterior Cervical Discectomy and Fusion: Comparison of Titanium and Polyetheretherketone Cages. BMC Musculoskelet. Disord., 13.","DOI":"10.1186\/1471-2474-13-172"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1673","DOI":"10.1016\/j.jocn.2011.11.043","article-title":"Outcomes of Contemporary Use of Rectangular Titanium Stand-Alone Cages in Anterior Cervical Discectomy and Fusion: Cage Subsidence and Cervical Alignment","volume":"19","author":"Yamagata","year":"2012","journal-title":"J. Clin. Neurosci."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1016\/j.spinee.2005.07.007","article-title":"Anterior Cervical Interbody Fusion with a Titanium Box Cage: Early Radiological Assessment of Fusion and Subsidence","volume":"5","author":"Spruit","year":"2005","journal-title":"Spine J."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1395","DOI":"10.1007\/s00586-006-0284-8","article-title":"Factors Affecting Sagittal Malalignment Due to Cage Subsidence in Standalone Cage Assisted Anterior Cervical Fusion","volume":"16","author":"Barsa","year":"2007","journal-title":"Eur. Spine J."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"12","DOI":"10.3340\/jkns.2014.55.1.12","article-title":"Anterior Cervical Discectomy and Fusion Using a Double Cylindrical Cage versus an Anterior Cervical Plating System with Iliac Crest Autografts for the Treatment of Cervical Degenerative Disc Disease","volume":"55","author":"Kim","year":"2014","journal-title":"J. Korean Neurosurg. Soc."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1280","DOI":"10.1097\/BRS.0000000000000400","article-title":"Risk Factors for Postoperative Subsidence of Single-Level Anterior Cervical Discectomy and Fusion: The Significance of the Preoperative Cervical Alignment","volume":"39","author":"Lee","year":"2014","journal-title":"Spine"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1007\/s10143-008-0168-y","article-title":"Subsidence after Anterior Cervical Inter-Body Fusion. A Randomized Prospective Clinical Trial","volume":"32","author":"Kast","year":"2009","journal-title":"Neurosurg. Rev."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1063","DOI":"10.1007\/s00701-015-2388-6","article-title":"Subsidence as of 12 Months after Single-Level Anterior Cervical Inter-Body Fusion. Is It Related to Clinical Outcomes?","volume":"157","author":"Lee","year":"2015","journal-title":"Acta Neurochir."},{"key":"ref_24","first-page":"43","article-title":"Is the Radiographic Subsidence of Stand-Alone Cages Associated with Adverse Clinical Outcomes after Cervical Spine Fusion? An Observational Cohort Study with 2-Year Follow-up Outcome Scoring","volume":"8","author":"Zajonz","year":"2014","journal-title":"Patient Saf. Surg."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1374","DOI":"10.1007\/s00586-011-2131-9","article-title":"Cage Subsidence Does Not, but Cervical Lordosis Improvement Does Affect the Long-Term Results of Anterior Cervical Fusion with Stand-Alone Cage for Degenerative Cervical Disc Disease: A Retrospective Study","volume":"21","author":"Wu","year":"2012","journal-title":"Eur. Spine J."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/13\/4\/1151\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T14:01:42Z","timestamp":1760104902000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/13\/4\/1151"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,18]]},"references-count":25,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2024,2]]}},"alternative-id":["jcm13041151"],"URL":"https:\/\/doi.org\/10.3390\/jcm13041151","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,18]]}}}