{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T18:46:16Z","timestamp":1777315576570,"version":"3.51.4"},"reference-count":75,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2024,2,19]],"date-time":"2024-02-19T00:00:00Z","timestamp":1708300800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Background: Classic endocrowns made of dental ceramics are considered a promising alternative to traditional post-endodontic restorations. The use of circular ferrules in endocrowns is a topic of controversial discussion. Therefore, the present study aims to evaluate the effect of ferrule design and cementation mode on the fatigue resistance of zirconia endocrowns. Methods: Eighty human molars were divided into four groups (n = 20): NFC (no-ferrule, conventional cementation), NFA (no-ferrule, adhesive luting), FC (ferrule, conventional cementation) and FA (ferrule, adhesive luting). Both the classic and the modified endocrown preparation with a two-millimeter ferrule design were carried out. Endocrowns were fabricated from zirconia using the CEREC system. After thermocycling, specimens were loaded according to the step-stress test up to 1500 N. Results: Failure rate was low; 88.8% of total specimens passed the step-stress test. Fractures were distributed between all groups; no significant differences in fatigue resistance were detected for preparation design and cementation mode. Conclusions: Endocrowns appear to be a promising concept for endodontically treated molars. Ferrule and also cementation mode have only a minor influence on fatigue resistance of zirconia endocrowns. However, at very high forces, the marginal area of the ferrule represents a weak point.<\/jats:p>","DOI":"10.3390\/jcm13041165","type":"journal-article","created":{"date-parts":[[2024,2,19]],"date-time":"2024-02-19T03:18:38Z","timestamp":1708312718000},"page":"1165","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Influence of Cementation Mode and Ferrule Design on the Fatigue Resistance of Monolithic Zirconia Endocrowns"],"prefix":"10.3390","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7776-0137","authenticated-orcid":false,"given":"Milan","family":"Stoilov","sequence":"first","affiliation":[{"name":"Department of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tobias","family":"Boehmer","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lea","family":"Stoilov","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Helmut","family":"Stark","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1365-7170","authenticated-orcid":false,"given":"Michael","family":"Marder","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Norbert","family":"Enkling","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany"},{"name":"Department of Reconstructive Dentistry and Gerodontology, Bern University, 3012 Bern, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dominik","family":"Kraus","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2024,2,19]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"475","DOI":"10.11607\/ijp.4120","article-title":"Effect of Post Placement on the Restoration of Endodontically Treated Teeth: A Systematic Review","volume":"5","author":"Zhu","year":"2015","journal-title":"Int. J. Prosthodont."},{"key":"ref_2","first-page":"312","article-title":"Reconstruction of endodontically treated posterior teeth with or without post? guidelines for the dental practitioner","volume":"4","author":"Zarow","year":"2009","journal-title":"Eur. J. Esthet. Dent."},{"key":"ref_3","first-page":"117","article-title":"Biomechanical considerations for the restoration of endodontically treated teeth: A systematic review of the literature, Part II (Evaluation of fatigue behavior, interfaces, and in vivo studies)","volume":"39","author":"Dietschi","year":"2008","journal-title":"Quintessence Int."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1016\/j.joen.2009.12.002","article-title":"Identifying and reducing risks for potential fractures in endodontically treated teeth","volume":"36","author":"Tang","year":"2010","journal-title":"J. Endod."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"100067","DOI":"10.1016\/j.dentre.2023.100067","article-title":"Post-endodontic restorative treatments and their mechanical behavior: A narrative review","volume":"3","year":"2023","journal-title":"Dent. Rev."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1016\/j.joen.2007.01.016","article-title":"Influence of the endodontic treatment on mechanical properties of root dentin","volume":"33","author":"Soares","year":"2007","journal-title":"J. Endod."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1111\/jerd.12065","article-title":"The endocrown: An alternative approach for restoring extensively damaged molars","volume":"25","author":"Biacchi","year":"2013","journal-title":"J. Esthet. Restor. Dent."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1016\/j.prosdent.2019.04.009","article-title":"Endocrowns: A systematic review","volume":"3","author":"Govare","year":"2020","journal-title":"J. Prosthet. Dent."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1016\/j.joen.2006.10.009","article-title":"Monoblocks in root canals: A hypothetical or a tangible goal","volume":"4","author":"Tay","year":"2007","journal-title":"J. Endod."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1016\/j.jdent.2012.01.006","article-title":"Effect of fibre post length and adhesive strategy on fracture resistance of endodontically treated teeth after fatigue loading","volume":"4","author":"Zicari","year":"2012","journal-title":"J. Dent."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.jdent.2010.10.004","article-title":"High volume individual fibre post versus low volume fibre post: The fracture load of the restored tooth","volume":"1","author":"Hatta","year":"2011","journal-title":"J. Dent."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1111\/jerd.12979","article-title":"Clinical in-situ evaluation of the effect of rubber dam isolation on bond strength to enamel","volume":"1","author":"Falacho","year":"2023","journal-title":"J. Esthet. Restor. Dent."},{"key":"ref_13","first-page":"CD009858","article-title":"Rubber dam isolation for restorative treatment in dental patients","volume":"5","author":"Miao","year":"2021","journal-title":"Cochrane Database Syst. Rev."},{"key":"ref_14","first-page":"25","article-title":"Zirconia: Cementation of prosthetic restorations. Literature review","volume":"4","author":"Gargari","year":"2010","journal-title":"Oral. Implantol."},{"key":"ref_15","unstructured":"Segarra, M., and Segarra, A.A. (2015). Practical Clinical Guide to Resin Cements, Springer. [1st ed.]."},{"key":"ref_16","first-page":"18","article-title":"The Effect of Various Finish Line Configurations on the Marginal Seal and Occlusal Discrepancy of Cast Full Crowns After Cementation\u2014An In-vitro Study","volume":"8","author":"Nemane","year":"2015","journal-title":"J. Clin. Diagn. Res."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1111\/j.1752-7325.2005.tb02792.x","article-title":"Root canal filled versus non-root canal filled teeth: A retrospective comparison of survival times","volume":"2","author":"Caplan","year":"2005","journal-title":"J. Public Health Dent."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1097\/00004770-200405000-00001","article-title":"Post placement and restoration of endodontically treated teeth: A literature review","volume":"5","author":"Schwartz","year":"2004","journal-title":"J. Endod."},{"key":"ref_19","first-page":"1439","article-title":"Fracture resistance of teeth restored with post-retained restorations: An overview","volume":"9","author":"Mahmoud","year":"2010","journal-title":"J. Endod."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"328","DOI":"10.4047\/jap.2017.9.5.328","article-title":"Effect of ferrule on the fracture resistance of mandibular premolars with prefabricated posts and cores","volume":"5","author":"Kim","year":"2017","journal-title":"J. Adv. Prosthodont."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1280","DOI":"10.1016\/j.dental.2013.10.003","article-title":"The influence of substance loss and ferrule height on the fracture resistance of endodontically treated premolars. An in vitro study","volume":"12","author":"Samran","year":"2013","journal-title":"Dent. Mater."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1038\/sj.bdj.2010.580","article-title":"Rethinking ferrule-a new approach to an old dilemma","volume":"1","author":"Jotkowitz","year":"2010","journal-title":"Br. Dent. J."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.cden.2010.01.001","article-title":"Modern molar endodontic access and directed dentin conservation","volume":"2","author":"Clark","year":"2010","journal-title":"Dent. Clin. N. Am."},{"key":"ref_24","first-page":"78","article-title":"The influence of post length and crown ferrule length on the resistance to cyclic loading of bovine teeth with prefabricated titanium posts International","volume":"1","author":"Isidor","year":"1999","journal-title":"J. Prosth"},{"key":"ref_25","first-page":"155","article-title":"Load fatigue of teeth restored with cast posts and cores and complete crowns","volume":"2","author":"Libman","year":"1995","journal-title":"Int. J. Prosthodont."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1046\/j.1365-2591.2002.00557.x","article-title":"The ferrule effect: A literature review","volume":"7","author":"Stankiewicz","year":"2002","journal-title":"Int. Endod. J."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.prosdent.2004.04.027","article-title":"An in vitro study evaluating the effect of ferrule length on fracture resistance of endodontically treated teeth restored with fiber-reinforced and zirconia dowel systems","volume":"2","author":"Akkayan","year":"2004","journal-title":"J. Prosth Dent."},{"key":"ref_28","first-page":"37","article-title":"Effect of Preparation Design on Marginal Integrity and Fracture Resistance of Endocrowns: A Systematic Review","volume":"19","author":"Mostafavi","year":"2022","journal-title":"Front. Dent."},{"key":"ref_29","first-page":"237","article-title":"Preparation Ferrule Design Effect on Endocrown Failure Resistance","volume":"1","author":"Einhorn","year":"2019","journal-title":"J. Prosthodont."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/j.jpor.2017.11.003","article-title":"Fracture resistance and failure modes of polymer infiltrated ceramic endocrown restorations with variations in margin design and occlusal thickness","volume":"3","author":"Taha","year":"2018","journal-title":"J. Prosthodont. Res."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"494","DOI":"10.11607\/ijp.8060","article-title":"The Influence of Ferrule on the Marginal Gap and Fracture Resistance of Zirconia Endo-crowns","volume":"4","author":"Bamajboor","year":"2022","journal-title":"Int. J. Prosthodont."},{"key":"ref_32","first-page":"140","article-title":"The endocrown: A different type of all-ceramic reconstruction for molars","volume":"79","author":"Fages","year":"2013","journal-title":"J. Can. Dent. Assoc."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"2256","DOI":"10.3390\/ceramics6040137","article-title":"Effect of Ferrule Design on Stress Distribution of Maxillary Incisor Rehabilitated with Ceramic Crown and PEEK Post\u2013Core Material: A 3D Finite Element Analysis","volume":"6","author":"Alberto","year":"2023","journal-title":"Ceramics"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.jdent.2017.10.011","article-title":"Restoration of severely damaged endodontically treated premolars: The influence of the endo-core length on marginal integrity and fatigue resistance of lithium disilicate CAD-CAM ceramic endocrowns","volume":"68","author":"Rocca","year":"2018","journal-title":"J. Dent."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1111\/jerd.12549","article-title":"Fracture resistance of teeth restored with endocrowns: An in vitro study","volume":"4","author":"Turkistani","year":"2020","journal-title":"J. Esthet. Restor. Dent."},{"key":"ref_36","first-page":"201","article-title":"Fracture resistance and microleakage of endocrowns utilizing three CAD-CAM blocks","volume":"2","author":"Platt","year":"2015","journal-title":"Oper. Dent."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/0022-3913(92)90602-7","article-title":"A review of the strength properties of dental ceramics","volume":"76","author":"Hondrun","year":"1992","journal-title":"J. Prosth dent"},{"key":"ref_38","first-page":"105","article-title":"Stress fatigue: Basic principles and prosthodontic implications","volume":"2","author":"Wiskott","year":"1995","journal-title":"Int. J. Prosthodont."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1016\/j.dental.2010.10.025","article-title":"Slow crack growth and reliability of dental ceramics","volume":"4","author":"Gonzaga","year":"2011","journal-title":"Dent. Mater."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1016\/j.prosdent.2013.09.020","article-title":"Fatigue resistance of CAD\/CAM complete crowns with a simplified cementation process","volume":"4","author":"Carvalho","year":"2014","journal-title":"J. Prosthet. Dent."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1007\/s40368-018-0344-x","article-title":"Zinc oxide eugenol paste jeopardises the adhesive bonding to primary dentine","volume":"3","author":"Pires","year":"2018","journal-title":"Eur. Arch. Paediatr. Dent."},{"key":"ref_42","first-page":"541","article-title":"Effect of Polymerization Accelerator on Bond Strength to Eugenol-Contaminated Dentin","volume":"6","author":"Wongsorachai","year":"2018","journal-title":"J. Adhes. Dent."},{"key":"ref_43","first-page":"99","article-title":"Endocrowns: A clinical report","volume":"39","author":"Lander","year":"2008","journal-title":"Quintessence Int."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1016\/j.dental.2013.12.012","article-title":"Long-term tensile bond strength of differently cemented nanocomposite CAD\/CAM crowns on dentin abutment","volume":"3","author":"Stawarczyk","year":"2014","journal-title":"Dent. Mater."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1613","DOI":"10.1016\/j.jdent.2014.08.013","article-title":"Comparison of fatigue resistance and failure modes between metal-ceramic and all-ceramic crowns by cyclic loading in water","volume":"12","author":"Nicolaisen","year":"2014","journal-title":"J. Dent."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"1192","DOI":"10.1016\/j.dental.2017.09.006","article-title":"ADM guidance-ceramics: Fatigue principles and testing","volume":"33","author":"Kelly","year":"2017","journal-title":"Dent. Mater."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1179\/2151090314Y.0000000009","article-title":"The craniofacial morphology and maximum bite force in sleep bruxism patients with signs and symptoms of temporomandibular disorders","volume":"33","author":"Karakis","year":"2015","journal-title":"Cranio"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1590\/S1678-77572006000600011","article-title":"The influence of gender and bruxism on the human maxi-mum bite force","volume":"14","author":"Calderon","year":"2006","journal-title":"J. Appl. Oral. Sci."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1016\/S0099-2399(07)80198-1","article-title":"In vitro bacterial penetration of coronally unsealed endodontically treated teeth","volume":"16","author":"Torabinejad","year":"1990","journal-title":"J. Endod."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1016\/j.dental.2013.09.014","article-title":"3D-Finite element analysis of molars restored with endocrowns and posts during masticatory simulation","volume":"29","author":"Dejak","year":"2013","journal-title":"Dent. Mater."},{"key":"ref_51","first-page":"219","article-title":"Survival of ceramic computer-aided design\/manufacturing crowns bonded to preparations with reduced macroretention geometry","volume":"18","author":"Bindl","year":"2005","journal-title":"Int. J. Prosthodont."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"141","DOI":"10.2186\/jpr.JPR_D_20_00082","article-title":"Fracture resistance of maxillary premolars restored with different endocrown designs and materials after artificial ageing","volume":"1","author":"Ahmed","year":"2022","journal-title":"J. Prosthodont. Res."},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Thomas, R.M., Kelly, A., Tagiyeva, N., and Kanagasingam, S. (Br. Dent. J., 2020). Comparing endocrown restorations on permanent molars and premolars: A systematic review and meta-analysis, Br. Dent. J., Online ahead of print.","DOI":"10.1038\/s41415-020-2279-y"},{"key":"ref_54","unstructured":"Ferencz, J.L., Silva, N.R.F.A., and Navarro, J.M. (2014). High Strength Ceramics: Interdisciplinary Perspectives, Quintessence Publishing. [1st ed.]."},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Sch\u00f6nhoff, L.M., L\u00fcmkemann, N., Buser, R., Hampe, R., and Stawarczyk, B. (2021). Fatigue resistance of monolithic strength-gradient zirconia materials. J. Mech. Behav. Biomed. Mater., 119.","DOI":"10.1016\/j.jmbbm.2021.104504"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"79","DOI":"10.4047\/jap.2018.10.2.79","article-title":"In-vitro performance and fracture strength of thin monolithic zirconia crowns","volume":"2","author":"Weigl","year":"2018","journal-title":"J. Adv. Prosthodont."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"244","DOI":"10.4047\/jap.2017.9.4.244","article-title":"In vitro study of the fracture resistance of monolithic lithium disilicate, monolithic zirconia, and lithium disilicate pressed on zirconia for three-unit fixed dental prostheses","volume":"4","author":"Choi","year":"2017","journal-title":"J. Adv. Prosthodont."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1016\/j.dental.2013.05.009","article-title":"Step-stress analysis for predicting dental ceramic reliability","volume":"8","author":"Borba","year":"2013","journal-title":"Dent. Mater."},{"key":"ref_59","doi-asserted-by":"crossref","unstructured":"Venturini, A.B., Bohrer, T.C., Fontana, P.E., Fr\u00f6hlich, T.T., May, L.G., Valandro, L.F., and Step-stress, vs. (2021). staircase fatigue tests to evaluate the effect of intaglio adjustment on the fatigue behavior of simplified lithium disilicate glass-ceramic restorations. J. Mech. Behav. Biomed. Mater., 113.","DOI":"10.1016\/j.jmbbm.2020.104091"},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1016\/j.jdent.2004.02.009","article-title":"Maximal bite forces in healthy young adults as predicted by surface electromyography","volume":"32","author":"Ferrario","year":"2004","journal-title":"J. Dent."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1590\/S1806-83242007000300015","article-title":"Maximal bite force in young adults with temporomandibular disorders and bruxism","volume":"21","author":"Pizolato","year":"2007","journal-title":"Braz. Oral. Res."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1055\/s-0034-1374647","article-title":"Maximum bite force analysis in different age groups","volume":"18","author":"Takaki","year":"2014","journal-title":"Int. Arch. Otorhinolaryngol."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"595","DOI":"10.2341\/13-004-L","article-title":"Influence of no-ferrule and no-post buildup design on the fatigue resistance of endodontically treated molars restored with resin nanoceramic CAD\/CAM crowns","volume":"39","author":"Magne","year":"2014","journal-title":"Oper. Dent."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1016\/j.dental.2016.01.004","article-title":"Fracture strength, failure type and Weibull characteristics of lithium disilicate and multiphase resin composite endocrowns under axial and lateral forces","volume":"32","author":"Gresnight","year":"2016","journal-title":"Dent. Mater."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1111\/j.1600-0722.2009.00704.x","article-title":"Finite element analyses to estimate failure risks in the ceramic endocrown and classical crown for endodontically treated maxillary premolars","volume":"118","author":"Lin","year":"2010","journal-title":"Eur. J. Oral. Sci."},{"key":"ref_66","first-page":"450","article-title":"Biomechanical behavior and Weibull survival of CAD-CAM endocrowns with different marginal designs: A 3D finite element analysis","volume":"23","author":"AboElhassan","year":"2023","journal-title":"Dent. Mater."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1111\/joor.12243","article-title":"Effect of length post and remaining root tissue on fracture resistance of fibre posts relined with resin composite","volume":"3","author":"Farina","year":"2015","journal-title":"J. Oral. Rehab"},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"942","DOI":"10.1016\/j.prosdent.2014.02.008","article-title":"Microhardness of light- and dual-polymerizable luting resins polymerized through 7.5-mm-thick endocrowns","volume":"4","author":"Gregor","year":"2014","journal-title":"J. Prosthet. Dent."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1111\/eos.12296","article-title":"Cost-effectiveness, in a randomized trial, of glass-ionomer-based and resin sealant materials after 4 yr","volume":"5","author":"Goldman","year":"2016","journal-title":"Eur. J. Oral. Sci."},{"key":"ref_70","doi-asserted-by":"crossref","unstructured":"Tuygunov, N., Zakaria, M.N., Yahya, N.A., Abdul Aziz, A., and Cahyanto, A. (2023). Efficacy and bone-contact biocompatibility of glass ionomer cement as a biomaterial for bone regeneration: A systematic review. J. Mech. Behav. Biomed. Mater., 146.","DOI":"10.1016\/j.jmbbm.2023.106099"},{"key":"ref_71","first-page":"553","article-title":"Early erosion of glass-ionomer cement at crown margins","volume":"6","author":"Curtis","year":"1993","journal-title":"Int. J. Prosthodont."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1111\/jerd.12486","article-title":"Fracture resistance and failure modes of endocrowns manufactured with different CAD-CAM materials under axial and lateral loading","volume":"31","author":"Ozcan","year":"2019","journal-title":"J. Esthet. Restor. Dent."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.jdent.2017.02.007","article-title":"Biomechanical behavior of endodontically treated premolars using different preparation designs and CAD-CAM materials","volume":"59","author":"Lise","year":"2017","journal-title":"J. Dent."},{"key":"ref_74","first-page":"116","article-title":"Practical clinical considerations of luting cements: A review","volume":"6","author":"Lad","year":"2014","journal-title":"J. Int. Oral. Health"},{"key":"ref_75","first-page":"415","article-title":"Survival and success of endocrowns: A systematic review and meta-analysis","volume":"3","year":"2021","journal-title":"J. Prosthet. Dent."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/13\/4\/1165\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T14:01:59Z","timestamp":1760104919000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/13\/4\/1165"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,19]]},"references-count":75,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2024,2]]}},"alternative-id":["jcm13041165"],"URL":"https:\/\/doi.org\/10.3390\/jcm13041165","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,19]]}}}