{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,17]],"date-time":"2026-01-17T01:41:28Z","timestamp":1768614088346,"version":"3.49.0"},"reference-count":20,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2024,4,13]],"date-time":"2024-04-13T00:00:00Z","timestamp":1712966400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Background: Pulmonary vein isolation (PVI) is a common therapeutic approach for symptomatic atrial fibrillation (AF). Among various techniques, cryo-balloon (CB) PVI is widely adopted, but, to date, established CB systems have had fixed balloon sizes. A novel size-adjustable CB, allowing balloon size adjustments during ablation, lacks sufficient data on optimal utilization in patient care. This study aims to systematically investigate this feature with a tailored ablation protocol. Methods: Our single-center prospective study included patients with paroxysmal or persistent atrial fibrillation undergoing first-time PVI with the size-adjustable CB from July 2023 to February 2024. Ablation was performed using the balloon size that provided better occlusion. The ablation protocol involved an initial occlusion test with the small balloon size (28 mm). If optimal occlusion (occlusion level 4) could not be achieved, an attempt with the larger balloon (31 mm) was initiated. Ablation was conducted using the balloon configuration that provided better occlusion of the pulmonary vein ostium. Results: Our prospective study includes 50 patients (median age [interquartile range, IQR]: 72 [65; 79] years, 24 [48.0%] females, and 35 [70.0%] patients with paroxysmal AF). The median procedure duration (IQR) was 77 (65; 96) minutes, and the median fluoroscopy time (IQR) was 17.7 (12.5; 22.0) min. PVI was successfully accomplished in each treated pulmonary vein (PV), with 87.4% of PVs isolated during the first freeze. The large balloon configuration was used to isolate 16.8% of PVs. Conclusions: The utilization of the size-adjustable CB, combined with the presented tailored ablation workflow, appears to facilitate effective and efficient pulmonary vein isolation. The use of a larger balloon configuration appears beneficial in isolating a significant proportion of the PVs.<\/jats:p>","DOI":"10.3390\/jcm13082262","type":"journal-article","created":{"date-parts":[[2024,4,15]],"date-time":"2024-04-15T08:08:12Z","timestamp":1713168492000},"page":"2262","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Pulmonary Vein Isolation with a Novel Size-Adjustable Cryo-Balloon Catheter: A Tailored Ablation Protocol"],"prefix":"10.3390","volume":"13","author":[{"given":"Yannick","family":"Teumer","sequence":"first","affiliation":[{"name":"Department of Cardiology, Ulm University Heart Center, Albert-Einstein-Allee 23, 89081 Ulm, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Franziska","family":"Hilgarth","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Ulm University Heart Center, Albert-Einstein-Allee 23, 89081 Ulm, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lyuboslav","family":"Katov","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Ulm University Heart Center, Albert-Einstein-Allee 23, 89081 Ulm, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rima","family":"Melnic","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Ulm University Heart Center, Albert-Einstein-Allee 23, 89081 Ulm, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wolfgang","family":"Rottbauer","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Ulm University Heart Center, Albert-Einstein-Allee 23, 89081 Ulm, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlo","family":"Bothner","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Ulm University Heart Center, Albert-Einstein-Allee 23, 89081 Ulm, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karolina","family":"Weinmann","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Ulm University Heart Center, Albert-Einstein-Allee 23, 89081 Ulm, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2024,4,13]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1093\/eurheartj\/ehaa612","article-title":"2020 ESC Guidelines for the Diagnosis and Management of Atrial Fibrillation Developed in Collaboration with the European Association for Cardio-Thoracic Surgery (EACTS)","volume":"42","author":"Hindricks","year":"2021","journal-title":"Eur. Heart J."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1161\/CIR.0000000000001193","article-title":"2023 ACC\/AHA\/ACCP\/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation: A Report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines","volume":"149","author":"Joglar","year":"2024","journal-title":"Circulation"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"e56","DOI":"10.1161\/CIR.0000000000000659","article-title":"Heart Disease and Stroke Statistics\u20142019 Update: A Report From the American Heart Association","volume":"139","author":"Benjamin","year":"2019","journal-title":"Circulation"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1056\/NEJM199809033391003","article-title":"Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins","volume":"339","author":"Shah","year":"1998","journal-title":"N. Engl. J. Med."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1056\/NEJMoa2029554","article-title":"Cryoballoon Ablation as Initial Therapy for Atrial Fibrillation","volume":"384","author":"Wazni","year":"2021","journal-title":"N. Engl. J. Med."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2235","DOI":"10.1056\/NEJMoa1602014","article-title":"Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation","volume":"374","author":"Kuck","year":"2016","journal-title":"N. Engl. J. Med."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1007\/s00380-020-01725-7","article-title":"Safety of Conscious Sedation in Electroanatomical Mapping Procedures and Cryoballoon Pulmonary Vein Isolation","volume":"36","author":"Weinmann","year":"2021","journal-title":"Heart Vessels"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Teumer, Y., Miesbichler, C., Katov, L., Mayer, B., Rottbauer, W., Bothner, C., and Weinmann, K. (2024). Comparison between a Novel Radiofrequency-Balloon and a Standard Cryo-Balloon in Pulmonary Vein Isolation: A Propensity-Score-Matched Analysis. J. Clin. Med., 13.","DOI":"10.3390\/jcm13040963"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1111\/jce.15861","article-title":"Acute Procedural Efficacy and Safety of a Novel Cryoballoon for the Treatment of Paroxysmal Atrial Fibrillation: Results from the POLAR ICE Study","volume":"34","author":"Martin","year":"2023","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Guckel, D., Lucas, P., Isgandarova, K., El Hamriti, M., Bergau, L., Fink, T., Sciacca, V., Imnadze, G., Braun, M., and Khalaph, M. (2022). News from the Cold Chamber: Clinical Experiences of POLARx versus Arctic Front Advance for Single-Shot Pulmonary Vein Isolation. J. Cardiovasc. Dev. Dis., 9.","DOI":"10.3390\/jcdd9010016"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"euad248","DOI":"10.1093\/europace\/euad248","article-title":"Novel or Established Cryoballoon Ablation System for Pulmonary Vein Isolation: The Prospective ICE-AGE-1 Study","volume":"25","author":"Heeger","year":"2023","journal-title":"Europace"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1111\/jce.15288","article-title":"The Established and the Challenger: A Direct Comparison of Current Cryoballoon Technologies for Pulmonary Vein Isolation","volume":"33","author":"Moser","year":"2022","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1111\/jce.16220","article-title":"One-year Outcomes of Pulmonary Vein Isolation with a Novel Cryoballoon: Primary Results of the FROZEN AF Trial","volume":"35","author":"Ellenbogen","year":"2024","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1111\/pace.14237","article-title":"Safety of Cryoballoon Ablation for the Treatment of Atrial Fibrillation: First European Results from the Cryo AF Global Registry","volume":"44","author":"Todd","year":"2021","journal-title":"Pacing Clin. Electrophysiol."},{"key":"ref_15","first-page":"1917","article-title":"Novel Cryoballoon Ablation System for Pulmonary Vein Isolation: Multicenter Assessment of Efficacy and Safety\u2014ANTARCTICA Study","volume":"24","author":"Heeger","year":"2022","journal-title":"EP Eur."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1660","DOI":"10.1056\/NEJMoa2307291","article-title":"Pulsed Field or Conventional Thermal Ablation for Paroxysmal Atrial Fibrillation","volume":"389","author":"Reddy","year":"2023","journal-title":"N. Engl. J. Med."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1256","DOI":"10.1093\/europace\/euac050","article-title":"Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation (MANIFEST-PF)","volume":"24","author":"Ekanem","year":"2022","journal-title":"EP Europace"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"e010516","DOI":"10.1161\/CIRCEP.121.010516","article-title":"Phrenic Nerve Injury During Cryoballoon-Based Pulmonary Vein Isolation: Results of the Worldwide YETI Registry","volume":"15","author":"Heeger","year":"2022","journal-title":"Circ. Arrhythm. Electrophysiol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"2559","DOI":"10.1111\/jce.14676","article-title":"A Systematic Review and Meta-analysis Comparing Second-generation Cryoballoon and Contact Force Radiofrequency Ablation for Initial Ablation of Paroxysmal and Persistent Atrial Fibrillation","volume":"31","author":"Ravi","year":"2020","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"ref_20","first-page":"1313","article-title":"Outcomes of Cryoballoon or Radiofrequency Ablation in Symptomatic Paroxysmal or Persistent Atrial Fibrillation","volume":"21","author":"Hoffmann","year":"2019","journal-title":"EP Eur."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/13\/8\/2262\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T14:27:31Z","timestamp":1760106451000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/13\/8\/2262"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,13]]},"references-count":20,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2024,4]]}},"alternative-id":["jcm13082262"],"URL":"https:\/\/doi.org\/10.3390\/jcm13082262","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,13]]}}}