{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T04:57:44Z","timestamp":1785387464446,"version":"3.55.0"},"reference-count":30,"publisher":"MDPI AG","issue":"16","license":[{"start":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T00:00:00Z","timestamp":1722988800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Vascular hemostasis after venous and arterial access in cardiovascular procedures remains a challenge. As sheath size gets larger for structural heart and vascular procedures, no dedicated closure devices exist that can overcome all the challenges of achieving vascular hemostasis, in particular on the venous side. Efficiently and reliably ensuring hemostasis at the access point is crucial for enhancing the safety of a procedure. Historically, hemostasis relied on manually compressing venous access sites. However, the shift towards larger sheaths and the more frequent use of continuous anticoagulation has strained this approach. Achieving hemostasis solely through compression in these scenarios demands heightened vigilance and prolonged application, resulting in increased patient discomfort and extended immobility. Consequently, manual compression may consume more time for healthcare providers and contribute to bed occupancy in hospitals. This review article summarizes the development of the SiteSeal\u00ae Vascular Closure Device, a novel leave-nothing-behind approach to achieve hemostasis. The introduction of this technology has provided clinicians with a safer and more effective way to achieve immediate hemostasis, facilitate early ambulation, and enable earlier discharges with fewer access site complications compared with traditional manual compression.<\/jats:p>","DOI":"10.3390\/jcm13164606","type":"journal-article","created":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T08:42:28Z","timestamp":1723020148000},"page":"4606","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["A Novel Suture-Based Vascular Closure Device to Achieve Hemostasis after Venous or Arterial Access While Leaving Nothing behind: A Review of the Technological Assessment and Early Clinical Outcomes"],"prefix":"10.3390","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9719-6382","authenticated-orcid":false,"given":"Saami K.","family":"Yazdani","sequence":"first","affiliation":[{"name":"Department of Engineering, Wake Forest University, Winston-Salem, NC 27101, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Omer","family":"Shedd","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Electrophysiology, CaroMont Regional Medical Center, Gastonia, NC 28054, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George","family":"Christy","sequence":"additional","affiliation":[{"name":"Department of Interventional Cardiology, Advocate Good Shepherd Hospital, Barrington, IL 60010, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rex","family":"Teeslink","sequence":"additional","affiliation":[{"name":"EnsiteVascular LLC, Olathe, KS 66061, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2024,8,7]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1056\/NEJMoa1511643","article-title":"A Leadless Intracardiac Transcatheter Pacing System","volume":"374","author":"Reynolds","year":"2016","journal-title":"N. Engl. J. Med."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"e275","DOI":"10.1016\/j.hrthm.2017.05.012","article-title":"2017 HRS\/EHRA\/ECAS\/APHRS\/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation","volume":"14","author":"Calkins","year":"2017","journal-title":"Heart Rhythm."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1240","DOI":"10.1016\/j.jacep.2017.05.005","article-title":"Catheter Ablation for Cardiac Arrhythmias: Utilization and In-Hospital Complications, 2000 to 2013","volume":"3","author":"Hosseini","year":"2017","journal-title":"JACC Clin. Electrophysiol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"e008998","DOI":"10.1161\/CIRCINTERVENTIONS.120.008998","article-title":"Percutaneous Interventions for Secondary Mitral Regurgitation","volume":"13","author":"Ali","year":"2020","journal-title":"Circ. Cardiovasc. Interv."},{"key":"ref_5","first-page":"euae043","article-title":"2024 European Heart Rhythm Association\/Heart Rhythm Society\/Asia Pacific Heart Rhythm Society\/Latin American Heart Rhythm Society expert consensus statement on catheter and surgical ablation of atrial fibrillation","volume":"26","author":"Tzeis","year":"2024","journal-title":"J. Interv. Card Electrophysiol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1007\/s10840-021-00981-5","article-title":"Comparative outcomes of vascular access closure methods following atrial fibrillation\/flutter catheter ablation: Insights from VAscular Closure for Cardiac Ablation Registry","volume":"64","author":"Mohammed","year":"2022","journal-title":"J. Interv. Card. Electrophysiol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1002\/ccd.27003","article-title":"A randomized comparison of modified subcutaneous \"Z\"-stitch versus manual compression to achieve hemostasis after large caliber femoral venous sheath removal","volume":"91","author":"Pracon","year":"2018","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Gupta, S., Kolluri, R., Simoes, T., Pingle, S.C., Nie, H., Lloyd, M.S., Steinhaus, D., Westerman, S.B., Shah, A., and Kline, J. (2024). Safety of multi-access site venous closure following catheter ablation of atrial fibrillation and flutter. J. Interv. Card. Electrophysiol.","DOI":"10.1007\/s10840-024-01773-3"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.jacep.2019.08.013","article-title":"Venous Vascular Closure System Versus Manual Compression Following Multiple Access Electrophysiology Procedures: The AMBULATE Trial","volume":"6","author":"Natale","year":"2020","journal-title":"JACC Clin. Electrophysiol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1055\/s-0034-1393972","article-title":"Access and hemostasis: Femoral and popliteal approaches and closure devices-why, what, when, and how?","volume":"31","author":"Barbetta","year":"2014","journal-title":"Semin. Interv. Radiol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1007\/s10840-011-9552-6","article-title":"Rapid hemostasis at the femoral venous access site using a novel hemostatic pad containing kaolin after atrial fibrillation ablation","volume":"31","author":"Sairaku","year":"2011","journal-title":"J. Interv. Card. Electrophysiol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1048","DOI":"10.1093\/europace\/euz004","article-title":"Venous access-site closure with vascular closure device vs. manual compression in patients undergoing catheter ablation or left atrial appendage occlusion under uninterrupted anticoagulation: A multicentre experience on efficacy and complications","volume":"21","author":"Mohanty","year":"2019","journal-title":"Europace"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1002\/ccd.22946","article-title":"Technique of temporary subcutaneous \"Figure-of-Eight\" sutures to achieve hemostasis after removal of large-caliber femoral venous sheaths","volume":"78","author":"Cilingiroglu","year":"2011","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1093\/europace\/euv266","article-title":"Feasibility and safety of temporary subcutaneous venous figure-of-eight suture to achieve haemostasis after ablation of atrial fibrillation","volume":"18","author":"Kubala","year":"2016","journal-title":"Europace"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2806","DOI":"10.1111\/jce.14252","article-title":"A randomized comparison of manual pressure versus figure-of-eight suture for hemostasis after cryoballoon ablation for atrial fibrillation","volume":"30","author":"Kumar","year":"2019","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"965","DOI":"10.7150\/ijms.42593","article-title":"Feasibility of the Figure-of-8-Suture as Venous Closure in Interventional Electrophysiology: One Strategy for All?","volume":"17","author":"Jensen","year":"2020","journal-title":"Int. J. Med. Sci."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1007\/s10840-019-00547-6","article-title":"Efficacy and safety of figure-of-eight suture versus manual pressure for venous access closure: A systematic review and meta-analysis","volume":"57","author":"Atti","year":"2020","journal-title":"J. Interv. Card. Electrophysiol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"750","DOI":"10.33963\/KP.a2022.0148","article-title":"New approaches to achieving hemostasis after venous access in cardiovascular patients","volume":"80","author":"Leung","year":"2022","journal-title":"Kardiol. Pol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"856","DOI":"10.1111\/pace.14008","article-title":"A comparison of figure-of-8-suture versus manual compression for venous access closure after cardiac procedures: An updated meta-analysis","volume":"43","author":"Mujer","year":"2020","journal-title":"Pacing Clin. Electrophysiol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"A14277","DOI":"10.1161\/circ.146.suppl_1.14277","article-title":"Comparison of Three Vascular Closure Devices for Vascular Access Closure After Cardiac Electrophysiology Procedures","volume":"146","author":"Gianni","year":"2022","journal-title":"Circulation"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1016\/S0735-1097(01)01449-8","article-title":"Vascular complications after percutaneous coronary interventions following hemostasis with manual compression versus arteriotomy closure devices","volume":"38","author":"Dangas","year":"2001","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_22","first-page":"956","article-title":"Efficacy and Safety of Figure-of-Eight Suture for Hemostasis After Radiofrequency Catheter Ablation for Atrial Fibrillation","volume":"82","author":"Okada","year":"2018","journal-title":"Circ. J. Off. J. Jpn. Circ. Soc."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"I9","DOI":"10.1161\/01.CIR.0000078469.07362.E6","article-title":"Risk factors for venous thromboembolism","volume":"107","author":"Anderson","year":"2003","journal-title":"Circulation"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1175","DOI":"10.1111\/pace.13764","article-title":"Comparison of standard vs modified \"figure-of-eight\" suture to achieve femoral venous hemostasis after cryoballoon based atrial fibrillation ablation","volume":"42","author":"Yorgun","year":"2019","journal-title":"Pacing Clin. Electrophysiol."},{"key":"ref_25","first-page":"392","article-title":"Figure-of-eight suture combined with a three-way stopcock for venous closure following left atrial appendage occlusion or patent foramen ovale closure","volume":"13","author":"Rasmussen","year":"2021","journal-title":"Interv. Cardiol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0002-9610(00)00535-3","article-title":"Concepts in service marketing for healthcare professionals","volume":"181","author":"Corbin","year":"2001","journal-title":"Am. J. Surg."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/j.carrev.2015.12.011","article-title":"Impact of lean six sigma process improvement methodology on cardiac catheterization laboratory efficiency","volume":"17","author":"Agarwal","year":"2016","journal-title":"Cardiovasc. Revascularization Med. Incl. Mol. Interv."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1017","DOI":"10.1111\/pace.13405","article-title":"Figure-of-eight sutures for hemostasis result in shorter lab recovery time after ablation for atrial fibrillation","volume":"41","author":"Payne","year":"2018","journal-title":"Pacing Clin. Electrophysiol."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1002\/ccd.28657","article-title":"Torque device suture technique to achieve hemostasis in large-bore venous access","volume":"95","author":"Karahalios","year":"2020","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"8569188","DOI":"10.1155\/2022\/8569188","article-title":"Vascular Closure Devices versus Manual Compression in Cardiac Interventional Procedures: Systematic Review and Meta-Analysis","volume":"2022","author":"Pang","year":"2022","journal-title":"Cardiovasc. Ther."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/13\/16\/4606\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T15:31:12Z","timestamp":1760110272000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/13\/16\/4606"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,7]]},"references-count":30,"journal-issue":{"issue":"16","published-online":{"date-parts":[[2024,8]]}},"alternative-id":["jcm13164606"],"URL":"https:\/\/doi.org\/10.3390\/jcm13164606","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,7]]}}}