{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T16:01:14Z","timestamp":1792425674307,"version":"4.5.0"},"reference-count":23,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2025,1,11]],"date-time":"2025-01-11T00:00:00Z","timestamp":1736553600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Background: This study aims to evaluate the repeatability of the Pentacam HR, comparing two different measurement modes (50-cornea fine and 25-3D scan) in patients affected by keratoconus. Methods: Multicenter retrospective study, conducted at Eye Clinic of the ASST-Spedali Civili-University of Brescia, Italy, and St. Paul\u2019s Eye Unit, Royal Liverpool University Hospital, United Kingdom. A total of 72 eyes from 72 patients with keratoconus underwent six consecutive measurements, three using the 25-3D scan mode and three with the 50-Cornea fine mode. Measurements were made by one single observer, using the Scheimpflug corneal tomographer camera (Pentacam HR, Oculus, Wetzlar, Germany). Repeatability was assessed using the within-subject SD (Sw) statistic from a two-way analysis of variance. Results: Both measurement modes had excellent repeatability. The interclass coefficient correlation (ICC) was excellent (&gt;0.9) in all the parameters evaluated, apart from anterior and posterior astigmatic axes and posterior astigmatism (ICC &gt; 0.8) and index of height asymmetry (IHA) (ICC &lt; 0.6). However, in 18 of 29 parameters, the ICC was higher in case of 25-3D scan. Repeatability limit for Kmax was 1.00D in 25-3D scan mode and 1.02D in case of 50-cornea fine. Conclusions: 25-3D scan may be preferable to 50-Cornea fine, in view of having slightly higher ICC in case of patients with keratoconus. Repeatability limits reported may be helpful in clinical practice for assessing the progression of keratoconus.<\/jats:p>","DOI":"10.3390\/jcm14020439","type":"journal-article","created":{"date-parts":[[2025,1,13]],"date-time":"2025-01-13T06:42:15Z","timestamp":1736750535000},"page":"439","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Repeatability of Pentacam HR in Keratoconus According to Two Different Scan Protocols: 25-3D Scan and 50-Cornea Fine"],"prefix":"10.3390","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8961-242X","authenticated-orcid":false,"given":"Davide","family":"Romano","sequence":"first","affiliation":[{"name":"St. Paul\u2019s Eye Unit, Department of Corneal Diseases, Royal Liverpool University Hospital, Liverpool L7 8YA, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giulia","family":"Coco","sequence":"additional","affiliation":[{"name":"Department of Clinical Science and Translational Medicine, University of Rome Tor Vergata, 00133 Rome, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3976-242X","authenticated-orcid":false,"given":"Alfredo","family":"Borgia","sequence":"additional","affiliation":[{"name":"Cornea Unit, Mons. Dimiccoli Hospital, 70051 Barletta, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4996-7995","authenticated-orcid":false,"given":"Stefano","family":"Calza","sequence":"additional","affiliation":[{"name":"Unit of Biostatistics and Bioinformatics, Department of Molecular and Translational Medicine, University of Brescia, 25123 Brescia, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen","family":"Kaye","sequence":"additional","affiliation":[{"name":"St. Paul\u2019s Eye Unit, Department of Corneal Diseases, Royal Liverpool University Hospital, Liverpool L7 8YA, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kunal","family":"Gadhvi","sequence":"additional","affiliation":[{"name":"St. Paul\u2019s Eye Unit, Department of Corneal Diseases, Royal Liverpool University Hospital, Liverpool L7 8YA, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2275-4917","authenticated-orcid":false,"given":"Francesco","family":"Semeraro","sequence":"additional","affiliation":[{"name":"Eye Clinic, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, 25121 Brescia, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5148-7643","authenticated-orcid":false,"given":"Vito","family":"Romano","sequence":"additional","affiliation":[{"name":"Eye Clinic, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, 25121 Brescia, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,1,11]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1016\/S0039-6257(97)00119-7","article-title":"Keratoconus","volume":"42","author":"Rabinowitz","year":"1998","journal-title":"Surv. Ophthalmol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1162","DOI":"10.1097\/j.jcrs.0000000000000945","article-title":"Evaluation of corneal biomechanical behavior in vivo for healthy and keratoconic eyes using the stress\u2013strain index","volume":"48","author":"Padmanabhan","year":"2022","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"364","DOI":"10.3928\/1081597X-20220601-01","article-title":"Evaluation of Corneal Biomechanical Indices in Distinguishing Between Normal, Very Asymmetric, and Bilateral Keratoconic Eyes","volume":"38","author":"Herber","year":"2022","journal-title":"J. Refract. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"101559","DOI":"10.1016\/j.clae.2021.101559","article-title":"Keratoconus: An updated review","volume":"45","author":"Carracedo","year":"2022","journal-title":"Contact Lens Anterior Eye"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1097\/ICO.0000000000002150","article-title":"The Prevalence and Risk Factors for Keratoconus: A Systematic Review and Meta-Analysis","volume":"39","author":"Hashemi","year":"2020","journal-title":"Cornea"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1136\/bjophthalmol-2016-308682","article-title":"The natural history of corneal topographic progression of keratoconus after age 30 years in non-contact lens wearers","volume":"101","author":"Gokul","year":"2016","journal-title":"Br. J. Ophthalmol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1097\/ICO.0000000000000723","article-title":"Efficacy of Corneal Collagen Cross-Linking for the Treatment of Keratoconus","volume":"35","author":"Meiri","year":"2016","journal-title":"Cornea"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1683","DOI":"10.1007\/s00417-023-06287-8","article-title":"Epithelium-on versus epithelium-off corneal collagen crosslinking for keratoconus: A systematic review and meta-analysis","volume":"262","author":"Borchert","year":"2023","journal-title":"Graefe\u2019s Arch. Clin. Exp. Ophthalmol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1097\/ICO.0000000000003124","article-title":"Accelerated Corneal Collagen Cross-Linking Protocols for Progressive Keratoconus: Systematic Review and Meta-analysis","volume":"42","author":"Karam","year":"2022","journal-title":"Cornea"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1097\/ICO.0000000000000408","article-title":"Group of Panelists for the Global Delphi Panel Panel of Keratoconus and Ectatic Disease Global Consensus on Keratoconus and Ectatic Diseases","volume":"34","author":"Gomes","year":"2015","journal-title":"Cornea"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"250","DOI":"10.3928\/1081597X-20220114-02","article-title":"Repeatability and Comparison of Corneal Tomography in Mild to Severe Keratoconus Between the Anterior Segment OCT MS-39 and Pentacam HR","volume":"38","author":"Seiler","year":"2022","journal-title":"J. Refract. Surg."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1097\/ICL.0000000000000531","article-title":"Pentacam Accuracy in Discriminating Keratoconus From Normal Corneas: A Diagnostic Evaluation Study","volume":"45","author":"Hashemi","year":"2019","journal-title":"Eye Contact Lens Sci. Clin. Pr."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"414","DOI":"10.3928\/1081597X-20210315-03","article-title":"Clinical Validation of the Automated Characterization of Cone Size and Center in Keratoconic Corneas","volume":"37","author":"Lopes","year":"2021","journal-title":"J. Refract. Surg."},{"key":"ref_14","first-page":"154","article-title":"Repeatability of the Pentacam HR in Various Grades of Keratoconus","volume":"219","author":"Kreps","year":"2020","journal-title":"Arch. Ophthalmol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1097\/ICO.0000000000001373","article-title":"Evaluation of the Reliability and Repeatability of Scheimpflug System Measurement in Keratoconus","volume":"37","author":"Eguileor","year":"2017","journal-title":"Cornea"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/j.jcrs.2017.10.042","article-title":"Repeatability and reliability of ectasia display and topometric indices with the Scheimpflug system in normal and keratoconic eyes","volume":"44","author":"Kosekahya","year":"2018","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Gustafsson, I., Bergstr\u00f6m, A., Myers, A.C., Ivarsen, A., and Hjortdal, J. (2020). Association between keratoconus disease severity and repeatability in measurements of parameters for the assessment of progressive disease. PLoS ONE, 15.","DOI":"10.1371\/journal.pone.0228992"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/j.ophtha.2014.08.026","article-title":"Reduced Precision of the Pentacam HR in Eyes with Mild to Moderate Keratoconus","volume":"122","author":"Hashemi","year":"2015","journal-title":"Ophthalmology"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"7731","DOI":"10.1167\/iovs.10-7093","article-title":"A Comprehensive Evaluation of the Precision (Repeatability and Reproducibility) of the Oculus Pentacam HR","volume":"52","author":"McAlinden","year":"2011","journal-title":"Investig. Opthalmol. Vis. Sci."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1111\/j.1475-1313.2011.00851.x","article-title":"Statistical methods for conducting agreement (comparison of clinical tests) and precision (repeatability or reproducibility) studies in optometry and ophthalmology","volume":"31","author":"McAlinden","year":"2011","journal-title":"Ophthalmic Physiol. Opt."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"296","DOI":"10.3928\/1081597X-20180223-01","article-title":"Corneal Allogenic Intrastromal Ring Segments (CAIRS) Combined With Corneal Cross-linking for Keratoconus","volume":"34","author":"Jacob","year":"2018","journal-title":"J. Refract. Surg."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1421","DOI":"10.1097\/ICO.0000000000000978","article-title":"Intrastromal Corneal Ring Segment Implantation in 409 Paracentral Keratoconic Eyes","volume":"35","author":"Cueto","year":"2016","journal-title":"Cornea"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.joco.2019.01.010","article-title":"Comparison of Anterior Chamber Depth between Normal and Keratoconic Eyes","volume":"32","author":"Hashemi","year":"2020","journal-title":"J. Curr. Ophthalmol."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/2\/439\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T10:27:04Z","timestamp":1759919224000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/2\/439"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,11]]},"references-count":23,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2025,1]]}},"alternative-id":["jcm14020439"],"URL":"https:\/\/doi.org\/10.3390\/jcm14020439","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,11]]}}}