{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,25]],"date-time":"2026-02-25T05:59:08Z","timestamp":1771999148607,"version":"3.50.1"},"reference-count":27,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2025,3,15]],"date-time":"2025-03-15T00:00:00Z","timestamp":1741996800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Background: We evaluate the accuracy of intraocular lens (IOL) power calculation in the following formulas\u2014Barrett True-K No History (BTKNH), EVO 2.0 Post-Hyperopic LASIK\/PRK (EVO 2.0), Haigis-L, Pearl-DGS, and Shammas (SF)\u2014with patients who have undergone cataract surgery at the Eye Unit of University of Campania Luigi Vanvitelli, Naples, Italy, and had prior hyperopic laser refractive surgery. Methods: A monocentric, retrospective, comparative study, including the charts of patients who had undergone cataract surgery and previous hyperopic laser refractive surgery, was retrospectively reviewed. Patients with no other ocular or systemic disease which might interfere with visual acuity results and no operative complications or combined surgery were enrolled. The mean absolute prediction error (MAE) was calculated for each formula and compared. Subgroup analysis based on the axial length and mean keratometry was performed. Results: A total of 107 patients (107 eyes) were included. The MAE calculated with SF provided less accurate (p &lt; 0.05) results when compared to both BTKNH and EVO 2.0 formulas. The MAE obtained using Haigis-L, EVO 2.0, Pearl-DGS, and BTKNH showed no significant differences. Conclusions: The analysis of the accuracy of the selected formulas shows no clear advantage in using one specific formula in standard cases, but in eyes where it is mandatory to reach the target refraction, SF should be avoided.<\/jats:p>","DOI":"10.3390\/jcm14061990","type":"journal-article","created":{"date-parts":[[2025,3,17]],"date-time":"2025-03-17T04:29:28Z","timestamp":1742185768000},"page":"1990","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Evaluation of Reliability of Formulas for Intraocular Lens Power Calculation After Hyperopic Refractive Surgery"],"prefix":"10.3390","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5252-6256","authenticated-orcid":false,"given":"Rosa","family":"Boccia","sequence":"first","affiliation":[{"name":"Multidisciplinary Department of Medical, Surgical and Dental Specialities, Universit\u00e0 della Campania Luigi Vanvitelli, 80132 Naples, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1578-7155","authenticated-orcid":false,"given":"Michele","family":"Lanza","sequence":"additional","affiliation":[{"name":"Multidisciplinary Department of Medical, Surgical and Dental Specialities, Universit\u00e0 della Campania Luigi Vanvitelli, 80132 Naples, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giuseppe","family":"Luciano","sequence":"additional","affiliation":[{"name":"Multidisciplinary Department of Medical, Surgical and Dental Specialities, Universit\u00e0 della Campania Luigi Vanvitelli, 80132 Naples, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Italo","family":"Fattore","sequence":"additional","affiliation":[{"name":"Multidisciplinary Department of Medical, Surgical and Dental Specialities, Universit\u00e0 della Campania Luigi Vanvitelli, 80132 Naples, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9484-5060","authenticated-orcid":false,"given":"Luigi","family":"Serra","sequence":"additional","affiliation":[{"name":"Multidisciplinary Department of Medical, Surgical and Dental Specialities, Universit\u00e0 della Campania Luigi Vanvitelli, 80132 Naples, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Salvatore","family":"Ambrosio","sequence":"additional","affiliation":[{"name":"Multidisciplinary Department of Medical, Surgical and Dental Specialities, Universit\u00e0 della Campania Luigi Vanvitelli, 80132 Naples, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francesco","family":"Abbate","sequence":"additional","affiliation":[{"name":"Multidisciplinary Department of Medical, Surgical and Dental Specialities, Universit\u00e0 della Campania Luigi Vanvitelli, 80132 Naples, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francesca","family":"Simonelli","sequence":"additional","affiliation":[{"name":"Multidisciplinary Department of Medical, Surgical and Dental Specialities, Universit\u00e0 della Campania Luigi Vanvitelli, 80132 Naples, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2025,3,15]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1097\/ICU.0000000000000067","article-title":"Management of residual refractive error after cataract surgery","volume":"25","author":"Alio","year":"2014","journal-title":"Curr. Opin. Ophthalmol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"e94","DOI":"10.1016\/j.ophtha.2020.08.010","article-title":"Intraocular Lens Power Formulas, Biometry, and Intraoperative Aberrometry: A Review","volume":"128","author":"Kane","year":"2021","journal-title":"Ophthalmology"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1016\/j.jcrs.2006.01.034","article-title":"New options for IOL calculations after refractive surgery","volume":"32","author":"Koch","year":"2006","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1016\/j.jcrs.2009.01.005","article-title":"Intraocular lens power calculation after previous laser refractive surgery","volume":"35","author":"Hoffer","year":"2009","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1658","DOI":"10.1016\/j.jcrs.2008.06.029","article-title":"Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula","volume":"34","author":"Haigis","year":"2008","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1097\/00003226-200111000-00003","article-title":"Intraocular lens power calculation after laser in situ keratomileusis for myopia and hyperopia; a standardized approach","volume":"20","author":"Feiz","year":"2001","journal-title":"Cornea"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1932","DOI":"10.1016\/S0886-3350(02)01438-4","article-title":"Measuring corneal power for intraocular lens power calculation after refractive surgery; comparison of methods","volume":"28","author":"Kim","year":"2002","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1016\/S0002-9394(03)00275-7","article-title":"Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situkeratomileusis","volume":"36","author":"Shammas","year":"2003","journal-title":"Am. J. Ophthalmol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"365","DOI":"10.3928\/1081-597X-20050701-11","article-title":"Keratometry for intraocular lens power calculation using Orbscan II in eyes with laser in situ keratomileusis","volume":"21","author":"Cheng","year":"2005","journal-title":"J. Refract. Surg."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1020","DOI":"10.1016\/j.jcrs.2004.10.055","article-title":"Reliability of a new correcting factor in calculating intraocular lens power after refractive corneal surgery","volume":"31","author":"Rosa","year":"2005","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1016\/j.jcrs.2005.12.106","article-title":"Simple regression formula for intraocular lens power adjustment in eyes requiring cataract surgery after excimer laser photoablation","volume":"32","author":"Masket","year":"2006","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2004","DOI":"10.1016\/j.jcrs.2006.08.037","article-title":"Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula","volume":"32","author":"Borasio","year":"2006","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2123","DOI":"10.1016\/j.jcrs.2010.07.017","article-title":"New factor to improve reliability of the clinical history method for intraocular lens power calculation after refractive surgery","volume":"36","author":"Rosa","year":"2010","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.ajo.2013.08.006","article-title":"Intraocular lens power calculation by ray-tracing after myopic excimer laser surgery","volume":"157","author":"Savini","year":"2014","journal-title":"Am. J. Ophthalmol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1109","DOI":"10.1016\/j.jcrs.2013.11.032","article-title":"Corneal ray-tracing versus simulated keratometry for estimating corneal power changes after excimer laser surgery","volume":"40","author":"Savini","year":"2014","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1016\/j.jcrs.2015.11.039","article-title":"Accuracy of the Barrett True-K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopia","volume":"42","author":"Abulafia","year":"2016","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Koprowski, R., Lanza, M., and Irregolare, C. (2016). Corneal power evaluation after myopic corneal refractive surgery using artificial neural networks. Biomed. Eng. Online, 15.","DOI":"10.1186\/s12938-016-0243-5"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1016\/j.jcrs.2014.05.040","article-title":"New algorithm for intraocular lens power calculations after myopic laser in situ keratolileusis based on rotating Scheimpflug camera data","volume":"41","author":"Potvin","year":"2015","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_19","first-page":"34","article-title":"Optical coherence tomography-based corneal power measurement and intraocular lens power calculation following laser vision correction","volume":"11","author":"Huang","year":"2013","journal-title":"Trans. Am. Ophthalmol. Soc."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"e133","DOI":"10.1111\/aos.12007","article-title":"A new central-peripheral corneal curvature method for intraocular lens power calculation after excimer laser refractive surgery","volume":"91","author":"Saiki","year":"2013","journal-title":"Acta Ophthalmol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"582","DOI":"10.1016\/j.jcrs.2018.12.006","article-title":"ASCRS calculator formula accuracy in multifocal intraocular lens implantation in hyperopic corneal refractive laser surgery eyes","volume":"45","author":"Vrijman","year":"2019","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Francone, A., Lemanski, N., Charles, M., Borboli-Gerogiannis, S., Chen, S., Robert, M.C., and Pineda, R. (2019). Retrospective comparative analysis of intraocular lens calculation formulas after hyperopic refractive surgery. PLoS ONE, 14.","DOI":"10.1371\/journal.pone.0224981"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/j.jcrs.2016.11.041","article-title":"Intraocular lens power calculations in eyes with previous hyperopic laser in situ keratomileusis or photorefractive keratectomy","volume":"43","author":"Hamill","year":"2017","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"580","DOI":"10.4103\/ijo.IJO_943_20","article-title":"Comparison of three newer generation freely available intraocular lens power calculation formulae across all axial lengths","volume":"69","author":"Khatib","year":"2021","journal-title":"Indian J. Ophthalmol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"999","DOI":"10.1016\/j.jcrs.2017.08.003","article-title":"Pursuing perfection in intraocular lens calculations: III. Criteria for analyzing outcomes","volume":"43","author":"Wang","year":"2017","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"736","DOI":"10.18240\/ijo.2024.04.19","article-title":"Systematic bibliometric analysis of research hotspots and trends on the application of premium IOLs in the past 2 decades","volume":"17","author":"Li","year":"2024","journal-title":"Int. J. Ophthalmol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"443","DOI":"10.3928\/1081597X-20220602-01","article-title":"Accuracy of Formulas for Intraocular Lens Power Calculation After Myopic Refractive Surgery","volume":"38","author":"Lanza","year":"2022","journal-title":"J. Refract. Surg."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/6\/1990\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T16:54:13Z","timestamp":1760028853000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/6\/1990"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,15]]},"references-count":27,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2025,3]]}},"alternative-id":["jcm14061990"],"URL":"https:\/\/doi.org\/10.3390\/jcm14061990","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,15]]}}}