{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T13:26:25Z","timestamp":1791465985143,"version":"4.3.4"},"reference-count":48,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2025,4,7]],"date-time":"2025-04-07T00:00:00Z","timestamp":1743984000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Background\/Objectives: One of the most serious complications following implant placement in the atrophic posterior mandible is injury to the inferior alveolar nerve (IAN), which can also happen during occlusal loading of the implants. This study investigates the effects of 4 mm implant stress transmission to the inferior alveolar nerve during occlusal loading in cases of severe posterior mandibular atrophy. Methods: The computer-aided design (CAD) model was created and modified through Direct Modeling techniques. The structure of cortical and trabecular bones was simplified, and it was modeled as a cylinder block. Finite element analysis (FEA) was carried out in 3D to investigate the pressure distribution over the IAN at different implant-to-nerve distances (1.5 mm, 0.5 mm, and 0.1 mm), and stress and strain deformations were simulated in the mandibular model. Results: The results of the pressure analysis on the inferior alveolar nerve indicate that the pressure distribution at different implant-to-nerve distances (1.5 mm, 0.5 mm, and 0.1 mm) is consistently below 0.026 MPa, which corresponds to the maximum pressure range that may block nerve impulses. This occurs even at the theoretical and simulated distance of 0.1 mm, suggesting that cortical bone stiffness plays a crucial role in mitigating stress at reduced implant-to-nerve proximities. Conclusions: Within the limits of this study, ultra-short implants can be placed even less than 0.5 mm (up to 0.1 mm under the 3D-FEA hypothesis) above the inferior alveolar nerve under the 3D-FEA hypothesis, while maintaining pressure below the threshold value. This is due to the rigidity of the cortical bone, which helps to reduce pressure transmission to the nerve. These findings may expand the indications for ultra-short implants, even in mandibles with a residual bone height of just 4 mm.<\/jats:p>","DOI":"10.3390\/jcm14072535","type":"journal-article","created":{"date-parts":[[2025,4,8]],"date-time":"2025-04-08T05:59:00Z","timestamp":1744091940000},"page":"2535","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Loading Pressure Induced by 4 mm Implants on the Inferior Alveolar Nerve: A 3D Finite Element Analysis Model"],"prefix":"10.3390","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6175-7806","authenticated-orcid":false,"given":"Roberta","family":"Gasparro","sequence":"first","affiliation":[{"name":"Department of Neuroscience, Reproductive Science and Dentistry, University of Naples Federico II, 80138 Naples, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabrizio","family":"Renno","sequence":"additional","affiliation":[{"name":"Department of Industrial Engineering, University of Naples Federico II, 80125 Naples, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simone","family":"De Vita","sequence":"additional","affiliation":[{"name":"Department of Neuroscience, Reproductive Science and Dentistry, University of Naples Federico II, 80138 Naples, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8485-7006","authenticated-orcid":false,"given":"Antonio","family":"Lanzotti","sequence":"additional","affiliation":[{"name":"Department of Industrial Engineering, University of Naples Federico II, 80125 Naples, Italy"},{"name":"CIRMIS, Centro Interdipartimentale di Ricerca in Management Sanitario e Innovazione in Sanit\u00e0, University of Naples Federico II, 80138 Naples, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8535-493X","authenticated-orcid":false,"given":"Massimo","family":"Martorelli","sequence":"additional","affiliation":[{"name":"Department of Industrial Engineering, University of Naples Federico II, 80125 Naples, Italy"},{"name":"CIRMIS, Centro Interdipartimentale di Ricerca in Management Sanitario e Innovazione in Sanit\u00e0, University of Naples Federico II, 80138 Naples, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4338-5444","authenticated-orcid":false,"given":"Francesco","family":"Penta","sequence":"additional","affiliation":[{"name":"Department of Industrial Engineering, University of Naples Federico II, 80125 Naples, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0579-794X","authenticated-orcid":false,"given":"Gilberto","family":"Sammartino","sequence":"additional","affiliation":[{"name":"Department of Neuroscience, Reproductive Science and Dentistry, University of Naples Federico II, 80138 Naples, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7683-5133","authenticated-orcid":false,"given":"Pietro","family":"Ausiello","sequence":"additional","affiliation":[{"name":"Department of Neuroscience, Reproductive Science and Dentistry, University of Naples Federico II, 80138 Naples, Italy"},{"name":"CIRMIS, Centro Interdipartimentale di Ricerca in Management Sanitario e Innovazione in Sanit\u00e0, University of Naples Federico II, 80138 Naples, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,4,7]]},"reference":[{"key":"ref_1","first-page":"e70","article-title":"Alveolar distraction osteogenesis for dental implant treatments of the vertical bone atrophy: A systematic review","volume":"24","year":"2019","journal-title":"Med. Oral Patol. Oral Cir. Bucal."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"26","DOI":"10.11607\/jomi.4479","article-title":"Efficacy of Alveolar Vertical Distraction Osteogenesis and Autogenous Bone Grafting for Dental Implants: Systematic Review and Meta-Analysis","volume":"31","author":"Yun","year":"2016","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1111\/prd.12539","article-title":"Guided bone regeneration in implant dentistry: Basic principle, progress over 35 years, and recent research activities","volume":"93","author":"Buser","year":"2023","journal-title":"Periodontol. 2000"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1038\/s41432-023-00924-1","article-title":"Comparing short implants to standard dental implants: A systematic review and meta-analysis of randomized controlled trials with extended follow-up","volume":"24","author":"Kermanshah","year":"2023","journal-title":"Evid.-Based Dent."},{"key":"ref_5","first-page":"167","article-title":"The efficacy of horizontal and vertical bone augmentation procedures for dental implants\u2014A Cochrane systematic review","volume":"2","author":"Esposito","year":"2009","journal-title":"Eur. J. Oral Implantol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"685","DOI":"10.11607\/prd.4522","article-title":"Guided Bone Regeneration with Nonresorbable Membranes in the Rehabilitation of Partially Edentulous Atrophic Arches: A Retrospective Study on 122 Implants with a 3- to 7-Year Follow-Up","volume":"40","author":"Pistilli","year":"2020","journal-title":"Int. J. Periodontics Restor. Dent."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1186\/s40729-023-00476-0","article-title":"Short implants compared to regular dental implants after bone augmentation in the atrophic posterior mandible: Umbrella review and meta-analysis of success outcomes","volume":"9","author":"Baeza","year":"2023","journal-title":"Int. J. Implant. Dent."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1111\/clr.13342","article-title":"Group 1 ITI Consensus Report: The influence of implant length and design and medications on clinical and patient-reported outcomes","volume":"29","author":"Jung","year":"2018","journal-title":"Clin. Oral Implants Res."},{"key":"ref_9","first-page":"267","article-title":"Short implants versus longer implants in vertically augmented atrophic mandibles: A systematic review of randomised controlled trials with a 5-year post-loading follow-up","volume":"12","author":"Esposito","year":"2019","journal-title":"Int. J. Oral Implantol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1111\/clr.12632","article-title":"Short implants compared to implants in vertically augmented bone: A systematic review","volume":"26","author":"Nisand","year":"2015","journal-title":"Clin. Oral Implants Res."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1249","DOI":"10.1016\/j.ijom.2021.01.005","article-title":"Vertical bone augmentation and regular implants versus short implants in the vertically deficient posterior mandible: A systematic review and meta-analysis of randomized studies","volume":"50","author":"Terheyden","year":"2021","journal-title":"Int. J. Oral Maxillofac. Surg."},{"key":"ref_12","first-page":"31","article-title":"Extra-short (4-mm) implants placed after regenerative failures in the posterior atrophic mandible: A retrospective study","volume":"16","author":"Barausse","year":"2023","journal-title":"Int. J. Oral Implantol."},{"key":"ref_13","first-page":"e199","article-title":"Severe atrophy of the posterior mandible and inferior alveolar nerve transposition","volume":"41","author":"Romanos","year":"2021","journal-title":"Int. J. Periodontics Restor. Dent."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1111\/jopr.13324","article-title":"Complications associated with rehabilitation of a unilateral partially edentulous mandible with inferior alveolar nerve transposition and implant placement: A clinical report","volume":"30","author":"Haeberle","year":"2021","journal-title":"J. Prosthodont."},{"key":"ref_15","first-page":"674","article-title":"The prevalence of altered sensation associated with implant surgery","volume":"8","author":"Ellies","year":"1993","journal-title":"Int. J. Oral Maxillofac. Implants."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1038\/sj.bdj.2009.258","article-title":"Case studies on implant removal influencing the resolution of inferior alveolar nerve injury","volume":"206","author":"Khawaja","year":"2009","journal-title":"Br. Dent. J."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1563\/AAID-JOI-D-09-00059","article-title":"Inferior alveolar nerve injury in implant dentistry: Diagnosis, causes, prevention, and management","volume":"36","author":"Alhassani","year":"2010","journal-title":"J. Oral Implantol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1735","DOI":"10.1902\/jop.2008.080030","article-title":"Analysis of the occlusal stress transmitted to the inferior alveolar nerve by an osseointegrated threaded fixture","volume":"79","author":"Sammartino","year":"2008","journal-title":"J. Periodontol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1902\/jop.2013.120611","article-title":"Analysis of occlusal stresses transmitted to the inferior alveolar nerve by multiple threaded implants","volume":"84","author":"Sammartino","year":"2013","journal-title":"J. Periodontol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"979","DOI":"10.1007\/s11517-017-1737-4","article-title":"Influence of implant number, length, and tilting degree on stress distribution in atrophic maxilla: A finite element study","volume":"56","author":"Korkmaz","year":"2018","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Sammartino, G., Prados-Frutos, J.C., Riccitiello, F., Felice, P., Cerone, V., Gasparro, R., and Wang, H.L. (2016). The relevance of the use of radiographic planning in order to avoid complications in mandibular implantology: A retrospective study. Biomed. Res. Int., 2016.","DOI":"10.1155\/2016\/8175284"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1080\/10255842.2020.1836168","article-title":"The use of different adhesive filling material and mass combinations to restore class II cavities under loading and shrinkage effects: A 3D-FEA","volume":"24","author":"Ausiello","year":"2021","journal-title":"Comput. Methods Biomech. Biomed. Engin."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Prati, C., Tribst, J.P.M., Piva, A.M.O.D., Zamparini, F., and Ausiello, P. (2021). 3D finite element analysis of rotary instruments in root canal dentine with different elastic moduli. Appl. Sci., 11.","DOI":"10.3390\/app11062547"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Cipollina, A., Ceddia, M., Di Pietro, N., Inchingolo, F., Tumedei, M., Romasco, T., Piattelli, A., Specchiulli, A., and Trentadue, B. (2023). Finite element analysis (FEA) of a premaxillary device: A new type of subperiosteal implant to treat severe atrophy of the maxilla. Biomimetics, 8.","DOI":"10.20944\/preprints202306.1150.v1"},{"key":"ref_25","first-page":"855","article-title":"Finite element analysis in the dental sciences: A bibliometric and a visual study","volume":"25","author":"Xie","year":"2024","journal-title":"Int. Dent. J."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.dental.2022.12.001","article-title":"Stress distribution in resin-based CAD-CAM implant-supported crowns","volume":"39","author":"Ausiello","year":"2023","journal-title":"Dent. Mater."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"8851098","DOI":"10.1155\/2023\/8851098","article-title":"A nonlinear three-dimensional finite element analysis of stress distribution and microstrain evaluation in short dental implants with three different implant-abutment connections in single and splinted conditions in the posterior mandible","volume":"2023","author":"Talreja","year":"2023","journal-title":"Int. J. Dent."},{"key":"ref_28","first-page":"24","article-title":"The influence of the shock-absorbing restorative materials on the stress distributions of short dental implant rehabilitations","volume":"25","author":"Huang","year":"2021","journal-title":"Eur. Rev. Med. Pharmacol. Sci."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1688","DOI":"10.1016\/j.dental.2021.08.022","article-title":"The role of cortical zone level and prosthetic platform angle in dental implant mechanical response: A 3D finite element analysis","volume":"37","author":"Ausiello","year":"2021","journal-title":"Dent. Mater."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Garavelli, C., Curreli, C., Palanca, M., Aldieri, A., Cristofolini, L., and Viceconti, M. (2022). Experimental validation of a subject-specific finite element model of lumbar spine segment using digital image correlation. PLoS ONE, 17.","DOI":"10.1371\/journal.pone.0272529"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1016\/S1350-4533(98)00081-2","article-title":"Material properties assignment to finite element models of bone structures: A new method","volume":"20","author":"Zannoni","year":"1998","journal-title":"Med. Eng. Phys."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"2483","DOI":"10.1016\/j.jbiomech.2008.05.017","article-title":"An accurate estimation of bone density improves the accuracy of subject-specific finite element models","volume":"41","author":"Schileo","year":"2008","journal-title":"J. Biomech."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1016\/j.medengphy.2006.10.014","article-title":"The material mapping strategy influences the accuracy of CT-based finite element models of bones: An evaluation against experimental measurements","volume":"29","author":"Tadde","year":"2007","journal-title":"Med. Eng. Phys."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"897","DOI":"10.1016\/S0021-9290(03)00071-X","article-title":"Trabecular Bone Modulus-Density Relationships Depend on Anatomic Site","volume":"36","author":"Morgan","year":"2003","journal-title":"J. Biomech."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/S0090-3019(02)00899-6","article-title":"Percutaneous trigeminal ganglion balloon compression for treatment of trigeminal neuralgia\u2014Part I: Pressure recordings","volume":"59","author":"Lee","year":"2003","journal-title":"Surg. Neurol."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1016\/j.msec.2014.01.013","article-title":"The influence of bone quality on the biomechanical behavior of full-arch implant-supported fixed prostheses","volume":"37","author":"Faverani","year":"2014","journal-title":"Mater. Sci. Eng. C Mater. Biol. Appl."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"219","DOI":"10.4012\/dmj.24.219","article-title":"Influence of cortical bone quality on stress distribution in bone around dental implant","volume":"24","author":"Kitagawa","year":"2005","journal-title":"Dent. Mater. J."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Chuang, C.L., Lai, C.L., Huang, A.C., Su, P.H., Chu, L.P., Hsieh, K.C., and Lu, H.K. (2024). Comparison of whole body bone mineral density measurements between dual energy X-ray absorptiometry and novel bioelectrical impedance analysis. Sci. Rep., 14.","DOI":"10.1038\/s41598-024-80721-7"},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Calvo-Gallego, J.L., Guti\u00e9rrez-Mill\u00e1n, F., Ojeda, J., P\u00e9rez, M.\u00c1., and Mart\u00ednez-Reina, J. (2022). The correlation between bone density and mechanical variables in bone remodelling models: Insights from a case study corresponding to the femur of a healthy adult. Mathematics, 10.","DOI":"10.3390\/math10183367"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.clinbiomech.2007.08.024","article-title":"Mathematical relationships between bone density and mechanical properties: A literature review","volume":"23","author":"Helgason","year":"2008","journal-title":"Clin. Biomech."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1115\/1.1338122","article-title":"Nonlinear behavior of trabecular bone at small strains","volume":"123","author":"Morgan","year":"2001","journal-title":"J. Biomech. Eng."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"780","DOI":"10.1111\/clr.12340","article-title":"Morphometric characteristics of cortical and trabecular bone in atrophic edentulous mandibles","volume":"26","author":"Bertl","year":"2015","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_43","first-page":"e4","article-title":"Evaluation of cortical thicknesses and bone density values of mandibular canal borders and coronal site of alveolar crest","volume":"14","author":"Goyushov","year":"2023","journal-title":"J. Oral Maxillofac. Res."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Aboelfadl, A., Keilig, L., Ebeid, K., Ahmed, M.A.M., Nouh, I., Refaie, A., and Bourauel, C. (2024). Biomechanical behavior of implant-retained prostheses in the posterior maxilla using different materials: A finite element study. BMC Oral Health, 24.","DOI":"10.1186\/s12903-024-04142-8"},{"key":"ref_45","doi-asserted-by":"crossref","unstructured":"Kligman, S., Ren, Z., Chung, C.H., Perillo, M.A., Chang, Y.C., Koo, H., Zheng, Z., and Li, C. (2021). The impact of dental implant surface modifications on osseointegration and biofilm formation. J. Clin. Med., 10.","DOI":"10.3390\/jcm10081641"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"1607","DOI":"10.1111\/clr.14349","article-title":"Four-mm-short implants in the rehabilitation of posterior atrophic jaws: A retrospective study on 212 patients with a mean follow-up of 8.02\u2009years","volume":"35","author":"Barausse","year":"2024","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_47","first-page":"221","article-title":"Posterior jaws rehabilitated with partial prostheses supported by 4.0 x 4.0 mm or by longer implants: Four-month post-loading data from a randomised controlled trial","volume":"8","author":"Esposito","year":"2015","journal-title":"Eur. J. Oral Implantol."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"936","DOI":"10.1111\/jcpe.13981","article-title":"Short (\u22646 mm) compared with \u226510-mm dental implants in different clinical scenarios: A systematic review of randomized clinical trials with meta-analysis, trial sequential analysis and quality of evidence grading","volume":"51","author":"Serroni","year":"2024","journal-title":"J. Clin. Periodontol."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/7\/2535\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T17:11:59Z","timestamp":1760029919000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/7\/2535"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,7]]},"references-count":48,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2025,4]]}},"alternative-id":["jcm14072535"],"URL":"https:\/\/doi.org\/10.3390\/jcm14072535","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,7]]}}}