{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T01:19:43Z","timestamp":1760059183219,"version":"build-2065373602"},"reference-count":24,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2025,5,26]],"date-time":"2025-05-26T00:00:00Z","timestamp":1748217600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"AST Products, Inc."}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Objectives: To evaluate the clinical performance and optical quality of a non-diffractive extended-depth-of-focus (EDOF) intraocular lens (IOL), Asqelio\u2122 EDOF (models ETLIO130C\/ETPIO130C), in patients undergoing cataract surgery or refractive lensectomy. Methods: This prospective observational, case-control study included patients bilaterally implanted with either the Asqelio\u2122 EDOF IOL (Study Group) or the spherical monofocal TECNIS\u00ae 1-Piece ZCB00 IOL (Control Group). The postoperative outcomes\u2014at 3 months after surgery\u2014included visual acuities at multiple distances, refraction, contrast sensitivity, the optical scatter index (OSI), wavefront aberrations, and patient-reported outcomes (Catquest-9SF and a quality-of-vision questionnaire). Results: Twenty-three patients (46 eyes) in the Asqelio\u2122 EDOF group and 17 patients (34 eyes) in the monofocal control group were enrolled. Postoperatively, 91% of eyes in the EDOF group were within \u00b10.50 D of the intended spherical equivalent. The binocular uncorrected distance, intermediate, and near visual acuities were 0.00 \u00b1 0.09, 0.13 \u00b1 0.12, and 0.32 \u00b1 0.15 logMAR, respectively. Contrast sensitivity and OSI values were similar between the study and control groups (p &gt; 0.05). Higher-order aberrations were significantly lower in the EDOF group (p &lt; 0.001), but values in both groups were clinically low. No adverse events were reported. Most patients expressed high satisfaction and reported few visual disturbances. Conclusions: The Asqelio\u2122 EDOF IOL provided good refractive predictability, effective uncorrected vision across distance and intermediate ranges, and high patient satisfaction. Contrast sensitivity and optical scatter were comparable to monofocal implants. This lens can be considered a valuable option for patients seeking an extended range of functional vision with minimal side effects.<\/jats:p>","DOI":"10.3390\/jcm14113717","type":"journal-article","created":{"date-parts":[[2025,5,26]],"date-time":"2025-05-26T04:49:52Z","timestamp":1748234992000},"page":"3717","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Clinical Performance and Optical Quality of a Non-Diffractive Extended-Depth-of-Focus Intraocular Lens in Patients Undergoing Cataract Surgery or Refractive Lensectomy"],"prefix":"10.3390","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3587-7892","authenticated-orcid":false,"given":"Antonio","family":"Cano-Ortiz","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Hospital Arruzafa, 14012 Cordoba, Spain"},{"name":"Department of Health and Biomedical Sciences, Universidad Loyola Andaluc\u00eda, 41704 Sevilla, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"\u00c1lvaro","family":"S\u00e1nchez-Ventosa","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Hospital Arruzafa, 14012 Cordoba, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9594-1601","authenticated-orcid":false,"given":"Timoteo","family":"Gonz\u00e1lez-Cruces","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Hospital Arruzafa, 14012 Cordoba, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8549-8431","authenticated-orcid":false,"given":"Marta","family":"Villalba-Gonz\u00e1lez","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Hospital Arruzafa, 14012 Cordoba, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francisco Javier","family":"Aguilar-Salazar","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Hospital Arruzafa, 14012 Cordoba, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6456-3572","authenticated-orcid":false,"given":"Juan J.","family":"Prados-Carmona","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Reina Sofia University Hospital, 14004 Cordoba, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vanesa","family":"D\u00edaz-Mesa","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Hospital Arruzafa, 14012 Cordoba, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7612-2555","authenticated-orcid":false,"given":"Alberto","family":"Villarrubia","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Hospital Arruzafa, 14012 Cordoba, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2025,5,26]]},"reference":[{"key":"ref_1","unstructured":"(2025, February 24). FDA News Release, Available online: https:\/\/www.fda.gov\/news-events\/fda-newsroom\/press-announcements."},{"key":"ref_2","first-page":"339","article-title":"Multifocal Intraocular Lenses and Extended Depth of Focus Intraocular Lenses","volume":"6","author":"Breyer","year":"2017","journal-title":"Asia Pac. J. Ophthalmol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1097\/j.jcrs.0000000000000109","article-title":"Extended depth-of-focus technology in intraocular lenses","volume":"46","author":"Kohnen","year":"2020","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1097\/APO.0000000000000296","article-title":"Extended Depth-of-Field Intraocular Lenses: An Update","volume":"9","author":"Kanclerz","year":"2020","journal-title":"Asia Pac. J. Ophthalmol."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Zhong, Y., Wang, K., Yu, X., Liu, X., and Yao, K. (2021). Comparison of trifocal or hybrid multifocal-extended depth of focus intraocular lenses: A systematic review and meta-analysis. Sci. Rep., 11.","DOI":"10.1038\/s41598-021-86222-1"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1016\/j.survophthal.2019.12.002","article-title":"Validation and application of Catquest-9SF in various populations: A systematic review","volume":"65","author":"Kabanovski","year":"2020","journal-title":"Surv. Ophthalmol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1791","DOI":"10.1016\/j.jcrs.2016.10.011","article-title":"Validation of the Spanish Catquest-9SF in patients with a monofocal or trifocal intraocular lens","volume":"42","author":"Llovet","year":"2016","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"5537","DOI":"10.1167\/iovs.10-5341","article-title":"The development of an instrument to measure quality of vision: The Quality of Vision (QoV) questionnaire","volume":"51","author":"McAlinden","year":"2010","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"218","DOI":"10.3928\/1081597X-20170302-01","article-title":"Standard for Reporting Refractive Outcomes of Intraocular Lens-Based Refractive Surgery","volume":"33","author":"Reinstein","year":"2017","journal-title":"J. Refract. Surg."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1625","DOI":"10.1016\/j.jcrs.2019.07.014","article-title":"Defocus curves of 4 presbyopia-correcting IOL designs: Diffractive panfocal, diffractive trifocal, segmental refractive, and extended-depth-of-focus","volume":"45","author":"Bohm","year":"2019","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.ophtha.2016.09.039","article-title":"Special report: American Academy of Ophthalmology task force consensus statement for extended depth of focus intraocular lenses","volume":"124","author":"MacRae","year":"2017","journal-title":"Ophthalmology"},{"key":"ref_12","unstructured":"(2018). American National Standard for Ophthalmics: Extended Depth of Focus Intraocular Lenses (Standard No. ANSI Z80.35-2018). Available online: https:\/\/webstore.ansi.org\/standards\/vc%20(asc%20z80)\/ansiz80352018."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Ta\u00f1\u00e1-Sanz, S., Ta\u00f1\u00e1-Sanz, P., Elvira-Giner, B., Orts-Vila, P., and Ta\u00f1\u00e1-Rivero, P. (2025). Visual performance, light distortion and patient reported outcomes with a new bi-aspheric non-diffractive extended depth of focus intraocular lens. Front. Med., 12.","DOI":"10.3389\/fmed.2025.1513803"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1177\/11206721221125004","article-title":"Visual outcomes of non-diffractive extended-depth-of-focus and enhanced monofocal intraocular lenses: A case-control study","volume":"33","author":"Sabur","year":"2023","journal-title":"Eur. J. Ophthalmol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1097\/j.jcrs.0000000000001330","article-title":"Visual performance and photic disturbances with diffractive and nondiffractive EDOF intraocular lenses using mini-monovision: Randomized trial","volume":"50","author":"Fernandes","year":"2024","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1097\/j.jcrs.0000000000000825","article-title":"Visual outcomes of a new nondiffractive extended depth-of-focus intraocular lens targeted for minimonovision: 3-month results of a prospective cohort study","volume":"48","author":"Webers","year":"2022","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"183","DOI":"10.2147\/OPTH.S350850","article-title":"Evaluation of quality of vision and visual outcomes with bilateral implantation of a non-diffractive extended vision intraocular lens with a target of slight myopia in the non-dominant eye","volume":"16","author":"Newsom","year":"2022","journal-title":"Clin. Ophthalmol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1097\/j.jcrs.0000000000001123","article-title":"Vision and patient-reported outcomes with nondiffractive EDOF or neutral aspheric monofocal intraocular lenses","volume":"49","author":"Pantanelli","year":"2023","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/S0886-3350(00)00562-9","article-title":"Normal values for the Pelli-Robson contrast sensitivity test","volume":"27","author":"Laitinen","year":"2001","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Giers, B.C., Khoramnia, R., Varadi, D., Wallek, H., Son, H.S., Attia, M.S., and Auffarth, G.U. (2019). Functional results and photic phenomena with new extended-depth-of-focus intraocular lens. BMC Ophthalmol., 19.","DOI":"10.1186\/s12886-019-1201-3"},{"key":"ref_21","first-page":"74","article-title":"Lens-based surgical correction of presbyopia. Where are we in 2020?","volume":"96","year":"2021","journal-title":"Arch. Soc. Esp. Oftalmol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1354","DOI":"10.1097\/j.jcrs.0000000000000988","article-title":"Visual disturbances produced after the implantation of 3 EDOF intraocular lenses vs 1 monofocal intraocular lens","volume":"48","author":"Guarro","year":"2022","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1579","DOI":"10.1038\/s41433-018-0131-2","article-title":"Three-year incidence of Nd:YAG capsulotomy and posterior capsule opacification and its relationship to monofocal acrylic IOL biomaterial: A UK Real World Evidence study","volume":"32","author":"Ursell","year":"2018","journal-title":"Eye"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.ajo.2023.05.002","article-title":"Recommendation for presbyopia-correcting intraocular lenses: A Delphi consensus statement by the ESASO Study Group","volume":"253","author":"Romano","year":"2023","journal-title":"Am. J. Ophthalmol."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/11\/3717\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T17:40:22Z","timestamp":1760031622000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/11\/3717"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,26]]},"references-count":24,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2025,6]]}},"alternative-id":["jcm14113717"],"URL":"https:\/\/doi.org\/10.3390\/jcm14113717","relation":{},"ISSN":["2077-0383"],"issn-type":[{"type":"electronic","value":"2077-0383"}],"subject":[],"published":{"date-parts":[[2025,5,26]]}}}