{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,9]],"date-time":"2026-08-09T23:41:42Z","timestamp":1786318902212,"version":"build-2736575974"},"reference-count":27,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2025,6,15]],"date-time":"2025-06-15T00:00:00Z","timestamp":1749945600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Background: This study aimed at delivering first clinical results after the use of a screw-and-PEEK rod system. Emphasis was placed on the ability of the construct to prevent adjacent segment disease at an average of 5 years follow up. Methods: The cohort was made up of 33 patients who received decompressive surgery in one segment and instrumentation with a screw-and-PEEK rod-based construct for stenosis of the lumbar spinal canal and a control group of 20 who received fusion surgery. Results: At an average of 68 months follow up there were 19 patients where the symptoms had markedly improved or completely subsided. There were also nine patients where the symptoms initially subsided only to reoccur years later and five who had a subjective non-satisfactory result. Conclusions: The system showed no major disadvantage when compared to similar non-fusion pedicle-based techniques, nor was it able to consequently prevent ASD. Under a clinical point of view, there was, in our opinion, no marked benefit when compared against decompressive surgery and fusion as the accepted standard.<\/jats:p>","DOI":"10.3390\/jcm14124252","type":"journal-article","created":{"date-parts":[[2025,6,16]],"date-time":"2025-06-16T06:40:27Z","timestamp":1750056027000},"page":"4252","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["A PEEK-Based Pedicle Screw System for One-Level Lumbar Spinal Canal Stenosis: An Appraisal at a Five-Year Follow Up"],"prefix":"10.3390","volume":"14","author":[{"given":"Andrei George","family":"Anghel","sequence":"first","affiliation":[{"name":"Spine Unit, Orthopaedic Clinic Hessisch Lichtenau, 37235 Hessisch Lichtenau, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonas","family":"Garthmann","sequence":"additional","affiliation":[{"name":"Spine Unit, Orthopaedic Clinic Hessisch Lichtenau, 37235 Hessisch Lichtenau, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Baraa","family":"Alkahawagi","sequence":"additional","affiliation":[{"name":"Spine Unit, Orthopaedic Clinic Hessisch Lichtenau, 37235 Hessisch Lichtenau, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,6,15]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"191","DOI":"10.2147\/MDER.S509958","article-title":"A PEEK Rod-Based Dynamic Instrumentation Construct for the Degenerative Lumbar Spine Disease, First Appraisal Based on Five-year Clinical and Radiological Findings","volume":"18","author":"Anghel","year":"2025","journal-title":"Med. Devices"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/BRS.0b013e31826cef01","article-title":"Introduction\/Summary statement: Adjacent segment pathology","volume":"37","author":"Riew","year":"2012","journal-title":"Spine"},{"key":"ref_3","unstructured":"(2020, October 03). Faktencheck Gesundheit, Bertelsmann Stiftung: Juni. Available online: https:\/\/faktencheck-gesundheit.de\/de\/startseite\/."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1497","DOI":"10.2106\/00004623-200407000-00020","article-title":"Adjacent segment degeneration in the lumbar spine","volume":"86","author":"Ghiselli","year":"2004","journal-title":"J. Bone Jt. Surg. Am."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"451956","DOI":"10.1155\/2013\/451956","article-title":"Biomechanics of Posterior Dynamic Stabilization Systems","volume":"2013","author":"Erbulut","year":"2013","journal-title":"Adv. Orthop."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1186\/s13018-018-0905-z","article-title":"Clinical experiences with a PEEK-based dynamic instrumentation device in lumbar spinal surgery: 2 years and no more","volume":"13","author":"Oikonomidis","year":"2018","journal-title":"J. Orthop. Surg."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Benezech, J., Garlenq, B., and Larroque, G. (2016). Flexible Stabilisation of the Degenerative Lumbar Spine Using. PEEK Rods. Adv. Orthop., 7369409.","DOI":"10.1155\/2016\/7369409"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"807","DOI":"10.4184\/asj.2015.9.5.807","article-title":"Adjacent Segment Pathology after Lumbar Spinal Fusion","volume":"9","author":"Lee","year":"2015","journal-title":"Asian Spine J."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"872","DOI":"10.1007\/s00586-015-4274-6","article-title":"Lumbar spinal degenerative \u201cmicroinstability\u201d: Hype or hope? Proposal of a new classification to detect it and to assess surgical treatment","volume":"24","author":"Landi","year":"2015","journal-title":"Eur. Spine J."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"149","DOI":"10.14245\/kjs.2013.10.3.149","article-title":"Analysis of Factors Contributing to Postoperative Spinal Instability after Lumbar Decompression for Spinal Stenosis","volume":"10","author":"Yang","year":"2013","journal-title":"Korean J. Spine"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1097\/BRS.0000000000000163","article-title":"Operative Duration as an Independent Risk Factor for Postoperative Complications in Single-Level Lumbar Fusion","volume":"39","author":"Kim","year":"2014","journal-title":"Spine"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"100077","DOI":"10.1016\/j.wnsx.2020.100077","article-title":"Fusion Surgery for Lumbar Spinal Stenosis: WFNS Spine Committee Recommendations","volume":"7","author":"Sharif","year":"2020","journal-title":"World Neurosurg. X"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"585","DOI":"10.3171\/2014.6.SPINE13190","article-title":"Decompression and nonfusion dynamic stabilization for spinal stenosis with degenerative lumbar scoliosis","volume":"21","author":"Lee","year":"2014","journal-title":"J. Neurosurg. Spine."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1007\/s00586-016-4637-7","article-title":"The outcome of decompression alone for lumbar spinal stenosis with degenerative spondylolisthesis","volume":"26","author":"Ahmad","year":"2017","journal-title":"Eur. Spine J."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1919","DOI":"10.1097\/BRS.0b013e3181d359bd","article-title":"Qualitative grading of severity of lumbar spinal stenosis based on the morphology of the dural sac on magnetic resonance images","volume":"35","author":"Schizas","year":"2010","journal-title":"Spine"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1413","DOI":"10.1056\/NEJMoa1513721","article-title":"A Randomized, Controlled Trial of Fusion Surgery for Lumbar Spinal Stenosis","volume":"374","author":"Carlsson","year":"2016","journal-title":"N. Engl. J. Med."},{"key":"ref_17","first-page":"120","article-title":"Reoperation rates and risk factors for revision 4 years after dynamic stabilization of the lumbar spine","volume":"19","author":"Krieg","year":"2018","journal-title":"Spine J."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1938","DOI":"10.1097\/01.brs.0000137069.88904.03","article-title":"Adjacent segment disease after lumbar or lumbosacral fusion: Review of the literature","volume":"1","author":"Park","year":"2004","journal-title":"Spine"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1111\/j.1532-5415.1994.tb01748.x","article-title":"Does radiographic osteoarthritis correlate with flexibility of the lumbar spine?","volume":"42","author":"Weiner","year":"1994","journal-title":"J. Am. Geriatr. Soc."},{"key":"ref_20","first-page":"371","article-title":"Spondyloptosis","volume":"54","author":"Meyerding","year":"1932","journal-title":"Surg. Gynaecol. Obstet."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1097\/BSD.0b013e318277ca7a","article-title":"Long-term outcome after monosegmental L4\/5 stabilization for degenerative spondylolisthesis with the Dynesys device","volume":"29","author":"Hoppe","year":"2016","journal-title":"Clin. Spine Surg."},{"key":"ref_22","first-page":"123","article-title":"Lumbar: Lumbar instability in surgical treatment without fusion","volume":"412","author":"Graf","year":"1992","journal-title":"Rachis"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1016\/j.ocl.2005.02.013","article-title":"Rationale, biomechanics, and surgical indications for Graf ligamentoplasty","volume":"36","author":"Kanayama","year":"2005","journal-title":"Orthop. Clin. N. Am."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"2206","DOI":"10.1097\/00007632-199911010-00006","article-title":"Stability analysis of an enhanced load sharing posterior fixation device and its equivalent conventional device in a calf spine model","volume":"24","author":"Scifert","year":"1999","journal-title":"Spine"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1097\/01.brs.0000157483.28505.e3","article-title":"The treatment mechanism of an interspinous process implant for lumbar neurogenic intermittent claudication","volume":"30","author":"Richards","year":"2005","journal-title":"Spine"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1198","DOI":"10.1097\/BRS.0b013e31819fcf35","article-title":"The influence of preoperative back pain on the outcome of lumbar decompression surgery","volume":"34","author":"Grob","year":"2009","journal-title":"Spine"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"712","DOI":"10.14245\/ns.2448184.092","article-title":"Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation with Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score","volume":"21","author":"Jiang","year":"2024","journal-title":"Neurospine"}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/12\/4252\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T17:52:20Z","timestamp":1760032340000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/12\/4252"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,15]]},"references-count":27,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2025,6]]}},"alternative-id":["jcm14124252"],"URL":"https:\/\/doi.org\/10.3390\/jcm14124252","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,15]]}}}