{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T12:57:04Z","timestamp":1786712224131,"version":"build-2736575974"},"reference-count":34,"publisher":"MDPI AG","issue":"14","license":[{"start":{"date-parts":[[2025,7,15]],"date-time":"2025-07-15T00:00:00Z","timestamp":1752537600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"BIOTRONIK SE &amp; Co. KG (Woermannkehre 1, D-12359 Berlin, Germany)"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Background\/Objectives: Patients with normal sinus rhythms undergoing cardiac resynchronization therapy defibrillator (CRT-D) implantation may benefit from a novel two-lead CRT-D system (CRT-DX), which features an atrial sensing dipole integrated into the right ventricular lead. This single-arm, international, non-controlled investigation focused on the safety and clinical efficacy of CRT-DX devices in CRT-D candidates who do not require atrial pacing. Methods: Patients indicated for CRT-D implantation (resting heart rates &gt; 40 bpm and \u2265100 bpm during exercise, no second or higher-degree AV block, and no history of persistent or permanent atrial fibrillation) were enrolled across 21 sites in four European countries. The primary endpoint was the need for an additional RA lead implantation within 12 months. Secondary endpoints comprised any invasive re-intervention to the CRT-DX system or infection. Results: Among the 110 patients (mean age 62 years, 70% male), 60% had an underlying non-ischemic cardiac disease. During 12 months of follow-up, RA lead implantation was required in two patients for atrial undersensing or chronotropic incompetence (RA lead implantation-free rate: 98.2% (95% CI: 92.7\u201399.5%)). Atrial sensing amplitudes were stable (mean: 4.7 \u00b1 1.7 mV), AV-synchrony was maintained at &gt;99%, and the median percentage of biventricular pacing exceeded 98%. The left ventricular ejection fraction improved by an absolute 14.7%. Conclusions: Using simple, clinically applicable inclusion criteria, the two-lead CRT-DX system demonstrated a low rate of subsequent RA lead implantations (1.8%) and maintained adequate RA sensing amplitudes throughout the observation period. The two-lead CRT-DX concept appears to be a feasible alternative for patients with preserved chronotropic competence.<\/jats:p>","DOI":"10.3390\/jcm14145009","type":"journal-article","created":{"date-parts":[[2025,7,15]],"date-time":"2025-07-15T15:01:05Z","timestamp":1752591665000},"page":"5009","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Biventricular Cardiac Resynchronization Therapy with Atrial Sensing but No Atrial Lead: A Prospective Registry of Patients, Complications, and Therapy Responses"],"prefix":"10.3390","volume":"14","author":[{"given":"Christof","family":"Kolb","sequence":"first","affiliation":[{"name":"Department of Cardiology, German Heart Centre, TUM University Hospital, Technical University of Munich, 80636 Munich, Germany"},{"name":"Department of Cardiology, Rhythmology, Angiology and Intensive Care Medicine, Heart Centre Osnabr\u00fcck, Hospital Osnabr\u00fcck, Westphalian Wilhelms University of M\u00fcnster, 49076 Osnabr\u00fcck, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5132-6009","authenticated-orcid":false,"given":"Endre","family":"Zima","sequence":"additional","affiliation":[{"name":"Heart and Vascular Center, Semmelweis Medical University, 1122 Budapest, Hungary"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Arnold","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Friedrich-Alexander-Universit\u00e4t Erlangen-Nuremberg, 91054 Erlangen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mari\u00e1n","family":"Fedorco","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Friedrich-Alexander-Universit\u00e4t Erlangen-Nuremberg, 91054 Erlangen, Germany"},{"name":"Department of Cardiology, University Hospital Olomouc, 77900 Olomouc, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-6071-5139","authenticated-orcid":false,"given":"Hendrik","family":"Bonnemeier","sequence":"additional","affiliation":[{"name":"Medical Faculty, Christian-Albrechts-University, 24105 Kiel, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Deneke","sequence":"additional","affiliation":[{"name":"Heart Center Bad Neustadt, 97616 Bad Neustadt, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Burghard","family":"Schumacher","sequence":"additional","affiliation":[{"name":"2nd Department of Medicine, Westpfalz-Klinikum, 67655 Kaiserslautern, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2560-4068","authenticated-orcid":false,"given":"Peter","family":"Nordbeck","sequence":"additional","affiliation":[{"name":"Internal Medicine I, University Hospital W\u00fcrzburg, 97080 W\u00fcrzburg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4963-5563","authenticated-orcid":false,"given":"Clemens","family":"Steinwender","sequence":"additional","affiliation":[{"name":"Department of Cardiology, University Hospital, Medical Faculty, Johannes Kepler University, 4020 Linz, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Theresa","family":"Storz","sequence":"additional","affiliation":[{"name":"Department of Cardiology, German Heart Centre, TUM University Hospital, Technical University of Munich, 80636 Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6514-0723","authenticated-orcid":false,"given":"B\u00e9la","family":"Merkely","sequence":"additional","affiliation":[{"name":"Heart and Vascular Center, Semmelweis Medical University, 1122 Budapest, Hungary"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lars","family":"Anneken","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Friedrich-Alexander-Universit\u00e4t Erlangen-Nuremberg, 91054 Erlangen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9087-071X","authenticated-orcid":false,"given":"Angelika","family":"Felk","sequence":"additional","affiliation":[{"name":"Biotronik, 12359 Berlin, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carsten","family":"Lennerz","sequence":"additional","affiliation":[{"name":"Department of Cardiology, German Heart Centre, TUM University Hospital, Technical University of Munich, 80636 Munich, Germany"},{"name":"Partner Site Munich Heart Alliance, German Centre for Cardiovascular Research (DZHK), 80636 Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,7,15]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"3427","DOI":"10.1093\/eurheartj\/ehab364","article-title":"2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy","volume":"42","author":"Glikson","year":"2021","journal-title":"Eur. Heart J."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"3599","DOI":"10.1093\/eurheartj\/ehab368","article-title":"2021 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure","volume":"42","author":"McDonagh","year":"2021","journal-title":"Eur. Heart J."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"2140","DOI":"10.1056\/NEJMoa032423","article-title":"Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) Investigators. Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure","volume":"350","author":"Bristow","year":"2004","journal-title":"N. Engl. J. Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.1056\/NEJMoa050496","article-title":"Cardiac Resynchronization-Heart Failure (CARE-HF) Study Investigators. The effect of cardiac resynchronization on morbidity and mortality in heart failure","volume":"352","author":"Cleland","year":"2005","journal-title":"N. Engl. J. Med."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"401","DOI":"10.7326\/0003-4819-154-6-201103150-00313","article-title":"Meta-analysis: Cardiac resynchronization therapy for patients with less symptomatic heart failure","volume":"154","author":"McAlister","year":"2011","journal-title":"Ann. Intern. Med."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1007","DOI":"10.1016\/j.jacc.2011.04.039","article-title":"Dual-chamber implantable cardioverter-defibrillator selection is associated with increased complication rates and mortality among patients enrolled in the NCDR implantable cardioverter-defibrillator registry","volume":"58","author":"Dewland","year":"2011","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"2025","DOI":"10.1001\/jama.2013.4982","article-title":"Association of single- vs. dual-chamber ICDs with mortality, readmissions, and complications among patients receiving an ICD for primary prevention","volume":"309","author":"Peterson","year":"2013","journal-title":"JAMA"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/j.ipej.2018.03.005","article-title":"Pre-CRAFT investigators. Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy","volume":"18","author":"Sticherling","year":"2018","journal-title":"Indian Pacing Electrophysiol. J."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1016\/j.tcm.2021.01.003","article-title":"Rationale and feasibility of the atrioventricular single-lead ICD systems with a floating atrial dipole (DX) in clinical practice","volume":"32","author":"Vamos","year":"2022","journal-title":"Trends Cardiovasc. Med."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1016\/j.ijcard.2017.09.189","article-title":"Less is more: Can we achieve cardiac resynchronization with 2 leads only?","volume":"249","author":"Biffi","year":"2017","journal-title":"Int. J. Cardiol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1784","DOI":"10.1111\/jce.14552","article-title":"Novel two-lead cardiac resynchronization therapy system provides equivalent CRT responses with less complications than a conventional three-lead system: Results from the QP ExCELs lead registry","volume":"31","author":"Shaik","year":"2020","journal-title":"J Cardiovasc. Electrophysiol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2281","DOI":"10.1093\/eurheartj\/eht150","article-title":"2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: The Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA)","volume":"34","author":"Brignole","year":"2013","journal-title":"Eur. Heart J."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2129","DOI":"10.1093\/eurheartj\/ehw128","article-title":"2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure: The Task Force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC)Developed with the special contribution of the Heart Failure Association (HFA) of the ESC","volume":"37","author":"Ponikowski","year":"2016","journal-title":"Eur. Heart J."},{"key":"ref_14","first-page":"w13938","article-title":"Outcome of patients with cardiac resynchronisation defibrillator therapy and a follow-up of at least five years after implant","volume":"144","author":"Bossard","year":"2014","journal-title":"Swiss Med. Wkly."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1093\/europace\/euv222","article-title":"Clinical outcomes in cardiac resynchronization therapy-defibrillator recipients 80 years of age and older","volume":"18","author":"Adelstein","year":"2016","journal-title":"Europace"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2697","DOI":"10.1093\/eurheartj\/ehr149","article-title":"Clinical course and outcome of patients enrolled in US and non-US centres in MADIT-CRT","volume":"32","author":"Buber","year":"2011","journal-title":"Eur. Heart J."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1007\/s12471-014-0556-6","article-title":"Incidence of lead dislodgement, malfunction and perforation during the first year following device implantation","volume":"22","author":"Ghani","year":"2014","journal-title":"Neth. Heart J."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1395","DOI":"10.1056\/NEJMoa1306687","article-title":"Cardiac-resynchronization therapy in heart failure with a narrow QRS complex","volume":"369","author":"Ruschitzka","year":"2013","journal-title":"N. Engl. J. Med."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1375","DOI":"10.1016\/j.jclinepi.2015.04.014","article-title":"A simple formula for the calculation of sample size in pilot studies","volume":"68","author":"Viechtbauer","year":"2015","journal-title":"J. Clin. Epidemiol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1622","DOI":"10.1016\/j.hrthm.2011.04.014","article-title":"Risk factors for lead complications in cardiac pacing: A population-based cohort study of 28,860 Danish patients","volume":"8","author":"Kirkfeldt","year":"2011","journal-title":"Heart Rhythm"},{"key":"ref_21","first-page":"2348","article-title":"MIRACLE Study Program. Safety of transvenous cardiac resynchronization system implantation in patients with chronic heart failure: Combined results of over 2000 patients from a multicenter study program","volume":"46","author":"Abraham","year":"2005","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"874","DOI":"10.1016\/j.hrthm.2024.02.053","article-title":"Complications of left bundle branch area pacing compared with biventricular pacing in candidates for resynchronization therapy: Results of a propensity score-matched analysis from a multicenter registry","volume":"21","author":"Palmisano","year":"2024","journal-title":"Heart Rhythm"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"995","DOI":"10.1016\/j.jacc.2011.06.007","article-title":"Implantation-related complications of implantable cardioverter-defibrillators and cardiac resynchronization therapy devices: A systematic review of randomized clinical trials","volume":"58","author":"Thijssen","year":"2011","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1016\/j.jacc.2008.09.043","article-title":"Heart failure decompensation and all-cause mortality in relation to percent biventricular pacing in patients with heart failure: Is a goal of 100% biventricular pacing necessary?","volume":"53","author":"Koplan","year":"2009","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1111\/pace.12171","article-title":"Study Investigators. Clinical efficacy and safety of an implantable cardioverter-defibrillator lead with a floating atrial sensing dipole","volume":"36","author":"Safak","year":"2013","journal-title":"Pacing Clin. Electrophysiol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1834","DOI":"10.1016\/j.jacc.2008.08.027","article-title":"REVERSE (REsynchronization reVErses Remodeling in Systolic left vEntricular dysfunction) Study Group. Randomized trial of cardiac resynchronization in mildly symptomatic heart failure patients and in asymptomatic patients with left ventricular dysfunction and previous heart failure symptoms","volume":"52","author":"Linde","year":"2008","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1056\/NEJMoa0906431","article-title":"Cardiac-resynchronization therapy for the prevention of heart-failure events","volume":"361","author":"Moss","year":"2009","journal-title":"N. Engl. J. Med."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1208","DOI":"10.1093\/europace\/euad043","article-title":"EHRA clinical consensus statement on conduction system pacing implantation: Endorsed by the Asia Pacific Heart Rhythm Society (APHRS), Canadian Heart Rhythm Society (CHRS), and Latin American Heart Rhythm Society (LAHRS)","volume":"25","author":"Burri","year":"2023","journal-title":"Europace"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1016\/j.hroo.2023.06.011","article-title":"Left bundle branch area pacing vs biventricular pacing for cardiac resynchronization: A systematic review and meta-analysis","volume":"4","author":"Yousaf","year":"2023","journal-title":"Heart Rhythm O2"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"5858","DOI":"10.19102\/icrm.2024.15053","article-title":"Clinical and Electrophysiological Outcomes of Left Bundle Area Pacing Compared to Biventricular Pacing: An Updated Meta-analysis","volume":"15","author":"Lakshman","year":"2024","journal-title":"J. Innov. Card. Rhythm. Manag."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1016\/j.jacc.2022.07.019","article-title":"LBBP-RESYNC Investigators. Randomized Trial of Left Bundle Branch vs Biventricular Pacing for Cardiac Resynchronization Therapy","volume":"80","author":"Wang","year":"2022","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1431","DOI":"10.1016\/j.jacep.2022.08.001","article-title":"Conduction System Pacing vs Biventricular Pacing in Heart Failure and Wide QRS Patients: LEVEL-AT Trial","volume":"8","author":"Garre","year":"2022","journal-title":"JACC Clin. Electrophysiol."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1016\/j.hrthm.2024.02.035","article-title":"Conduction system pacing versus biventricular pacing in heart failure with reduced ejection fraction: A systematic review and meta-analysis of randomized controlled trials","volume":"21","author":"Collini","year":"2024","journal-title":"Heart Rhythm"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"5985","DOI":"10.19102\/icrm.2024.15081","article-title":"Feasibility of Single-lead Cardiac Resynchronization and Defibrillation Therapy in an Animal Model","volume":"15","author":"Varela","year":"2024","journal-title":"J. Innov. Card. Rhythm. Manag."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/14\/5009\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T18:10:02Z","timestamp":1760033402000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/14\/5009"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,15]]},"references-count":34,"journal-issue":{"issue":"14","published-online":{"date-parts":[[2025,7]]}},"alternative-id":["jcm14145009"],"URL":"https:\/\/doi.org\/10.3390\/jcm14145009","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,15]]}}}