{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T14:45:18Z","timestamp":1783694718518,"version":"3.55.0"},"reference-count":26,"publisher":"MDPI AG","issue":"17","license":[{"start":{"date-parts":[[2025,8,30]],"date-time":"2025-08-30T00:00:00Z","timestamp":1756512000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Objectives: To assess the anatomical lens position (ALP) predictability for a capsulotomy-fixated intraocular lens (IOL; FEMTIS FB-313, Teleon Surgical B.V) versus an intracapsular IOL (TECNIS 1-Piece, ZCB00V, Johnson &amp; Johnson) implanted for age-related cataracts. Methods: Pre- and 3-month postoperative measurements from optical biometry and swept-source anterior segment OCT were analyzed. The lens position (i.e., postoperatively, ALP) was defined as the distance between the corneal endothelium and the lens equator. Multivariate linear mixed-effects models assessed the influence of preoperative biometric parameters on ALP, prediction error (PE), and absolute PE (AbsPE). Results: A total of 45 FEMTIS eyes from 32 patients and 26 TECNIS eyes from 18 patients were included. Postoperatively, the anterior chamber depth (ACD) increased by 1.10 mm in FEMTIS eyes and 1.66 mm in TECNIS eyes, while the lens position decreased by 0.59 mm and 0.34 mm, respectively. ACD and lens thickness (LT) were the strongest ALP predictors (ACD: \u03b2 = +0.70, p &lt; 0.0001; LT: \u03b2 = +0.37, p &lt; 0.0001). Separate multivariate models demonstrated strong predictive performance, with the FEMTIS achieving R2 = 0.92 and the TECNIS IOL performing even better with R2 = 0.97. In the FEMTIS group, LT influenced the PE (p = 0.006) and ACD the AbsPE (p = 0.005). In the TECNIS group, ACD influenced the PE (p &lt; 0.0001), while AbsPE was not significantly affected by biometric parameters or formulas. Conclusions: ALP can be reliably predicted from standard biometric data, although less accurately for the FEMTIS IOL. Its anterior capsulotomy fixation likely compromises refractive accuracy with formulas inherently designed and optimized for in-the-bag IOLs, emphasizing the need for fixation-specific formula adjustments and dedicated optimization in capsulotomy-fixated IOLs.<\/jats:p>","DOI":"10.3390\/jcm14176151","type":"journal-article","created":{"date-parts":[[2025,9,2]],"date-time":"2025-09-02T13:01:13Z","timestamp":1756818073000},"page":"6151","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Anatomical Lens Position Predictability for a Capsulotomy-Fixated Intraocular Lens in Femtosecond Laser-Assisted Cataract Surgery"],"prefix":"10.3390","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6746-3681","authenticated-orcid":false,"given":"Colya N.","family":"Englisch","sequence":"first","affiliation":[{"name":"Eye Clinic Sulzbach, Knappschaft Hospitals Saar, 66280 Sulzbach\/Saar, Germany"},{"name":"Department of Experimental Ophthalmology, Saarland University, 66421 Homburg\/Saar, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3587-6382","authenticated-orcid":false,"given":"Philip","family":"Wakili","sequence":"additional","affiliation":[{"name":"Eye Clinic Sulzbach, Knappschaft Hospitals Saar, 66280 Sulzbach\/Saar, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5328-9608","authenticated-orcid":false,"given":"Andr\u00e9","family":"Messias","sequence":"additional","affiliation":[{"name":"Eye Clinic Sulzbach, Knappschaft Hospitals Saar, 66280 Sulzbach\/Saar, Germany"},{"name":"Department of Ophthalmology, Otorhinolaryngology and Head and Neck Surgery, School of Medicine of Ribeir\u00e3o Preto, University of S\u00e3o Paulo, S\u00e3o Paulo 05508-220, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Szurman","sequence":"additional","affiliation":[{"name":"Eye Clinic Sulzbach, Knappschaft Hospitals Saar, 66280 Sulzbach\/Saar, Germany"},{"name":"Klaus Heimann Eye Research Institute (KHERI), 66280 Sulzbach\/Saar, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Annekatrin","family":"Rickmann","sequence":"additional","affiliation":[{"name":"Eye Clinic Sulzbach, Knappschaft Hospitals Saar, 66280 Sulzbach\/Saar, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clemens N.","family":"Rudolph","sequence":"additional","affiliation":[{"name":"Eye Clinic Sulzbach, Knappschaft Hospitals Saar, 66280 Sulzbach\/Saar, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-5945-1081","authenticated-orcid":false,"given":"Anna Theresa","family":"Fr\u00f6hlich","sequence":"additional","affiliation":[{"name":"Eye Clinic Sulzbach, Knappschaft Hospitals Saar, 66280 Sulzbach\/Saar, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9701-8204","authenticated-orcid":false,"given":"Berthold","family":"Seitz","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Saarland University Medical Center, 66421 Homburg\/Saar, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Achim","family":"Langenbucher","sequence":"additional","affiliation":[{"name":"Department of Experimental Ophthalmology, Saarland University, 66421 Homburg\/Saar, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karl T.","family":"Boden","sequence":"additional","affiliation":[{"name":"Eye Clinic Sulzbach, Knappschaft Hospitals Saar, 66280 Sulzbach\/Saar, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,8,30]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"e285","DOI":"10.1111\/aos.15726","article-title":"Impact of uncertainties in biometric parameters on intraocular lens power formula predicted refraction using a Monte-Carlo simulation","volume":"102","author":"Langenbucher","year":"2024","journal-title":"Acta Ophthalmol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1016\/j.jcrs.2007.10.031","article-title":"Sources of error in intraocular lens power calculation","volume":"34","author":"Norrby","year":"2008","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1111\/j.1755-3768.2007.00879.x","article-title":"Calculation of intraocular lens power: A review","volume":"85","author":"Olsen","year":"2007","journal-title":"Acta Ophthalmol. Scand."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/j.jcrs.2016.11.043","article-title":"Clinical and biometric determinants of actual lens position after cataract surgery","volume":"43","author":"Plat","year":"2017","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1007\/s00417-023-06175-1","article-title":"Predicting the postoperative intraocular lens position based on IOL Master 700 biometry, compared with results from the anterior segment analysis system","volume":"262","author":"Chang","year":"2024","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1016\/S0886-3350(13)80338-0","article-title":"The Hoffer Q formula: A comparison of theoretic and regression formulas","volume":"19","author":"Hoffer","year":"1993","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/S0886-3350(88)80059-2","article-title":"A three-part system for refining intraocular lens power calculations","volume":"14","author":"Holladay","year":"1988","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/S0886-3350(13)80705-5","article-title":"Development of the SRK\/T intraocular lens implant power calculation formula","volume":"16","author":"Retzlaff","year":"1990","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Schroder, S., and Langenbucher, A. (2018). Relationship between effective lens position and axial position of a thick intraocular lens. PLoS ONE, 13.","DOI":"10.1371\/journal.pone.0198824"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"e1378","DOI":"10.1111\/aos.15108","article-title":"Prediction of the axial lens position after cataract surgery using deep learning algorithms and multilinear regression","volume":"100","author":"Langenbucher","year":"2022","journal-title":"Acta Ophthalmol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1553","DOI":"10.21037\/atm-20-2290","article-title":"Recent developments in intraocular lens power calculation methods-update 2020","volume":"8","author":"Savini","year":"2020","journal-title":"Ann. Transl. Med."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1016\/j.jcrs.2005.12.139","article-title":"Prediction of the effective postoperative (intraocular lens) anterior chamber depth","volume":"32","author":"Olsen","year":"2006","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1097\/j.jcrs.0000000000001159","article-title":"Surgeons need to know more about intraocular lens design for accurate power calculation","volume":"49","author":"Olsen","year":"2023","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1007\/s00347-020-01092-8","article-title":"New intraocular lens designs for femtosecond laser-assisted cataract operations: Chances and benefits","volume":"117","author":"Holland","year":"2020","journal-title":"Ophthalmologe"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1016\/S0886-3350(02)01375-5","article-title":"Bag-in-the-lens implantation of intraocular lenses","volume":"28","author":"Tassignon","year":"2002","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/j.jcrs.2017.10.038","article-title":"Surgical management of negative dysphotopsia","volume":"44","author":"Masket","year":"2018","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"198","DOI":"10.3928\/1081597X-20140217-06","article-title":"Intraocular lens fixated in the anterior capsulotomy created in the line of sight by a femtosecond laser","volume":"30","author":"Dick","year":"2014","journal-title":"J. Refract. Surg."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.ajo.2020.12.025","article-title":"Stability and Visual Outcomes of the Capsulotomy-Fixated FEMTIS-IOL After Automated Femtosecond Laser-Assisted Anterior Capsulotomy","volume":"225","author":"Auffarth","year":"2021","journal-title":"Am. J. Ophthalmol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"e532","DOI":"10.3928\/1081597X-20250417-03","article-title":"Refraction Predictability for a Capsulotomy-Fixated Intraocular Lens in Femtosecond Laser-Assisted Cataract Surgery","volume":"41","author":"Englisch","year":"2025","journal-title":"J. Refract. Surg."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1016\/j.jcrs.2018.07.044","article-title":"Intraoperative optical coherence tomography measurements of aphakic eyes to predict postoperative position of 2 intraocular lens designs","volume":"44","author":"Hirnschall","year":"2018","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1097\/OPX.0b013e31819fa590","article-title":"Standardized patient methodology to assess refractive error reproducibility","volume":"86","author":"Shah","year":"2009","journal-title":"Optom. Vis. Sci."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"989","DOI":"10.1007\/s40123-021-00390-x","article-title":"Relationship Between Postoperative Intraocular Lens Shift and Postoperative Refraction Change in Cataract Surgery Using Three Different Types of Intraocular Lenses","volume":"10","author":"Teshigawara","year":"2021","journal-title":"Ophthalmol. Ther."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1016\/j.jcrs.2018.06.017","article-title":"Predicting pseudophakic refractive error: Interplay of biometry prediction error, anterior chamber depth, and changes in corneal curvature","volume":"44","author":"Wallace","year":"2018","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1007\/s004170000188","article-title":"Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis","volume":"238","author":"Haigis","year":"2000","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1097\/j.jcrs.0000000000001126","article-title":"Comparison of the new Hoffer QST with 4 modern accurate formulas","volume":"49","author":"Taroni","year":"2023","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1016\/j.ajo.2020.01.009","article-title":"Determining and Comparing the Effective Lens Position and Refractive Outcome of a Novel Rhexis-Fixated Lens to Established Lens Designs","volume":"213","author":"Shajari","year":"2020","journal-title":"Am. J. Ophthalmol."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/17\/6151\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T18:36:20Z","timestamp":1760034980000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/17\/6151"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,30]]},"references-count":26,"journal-issue":{"issue":"17","published-online":{"date-parts":[[2025,9]]}},"alternative-id":["jcm14176151"],"URL":"https:\/\/doi.org\/10.3390\/jcm14176151","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,30]]}}}