{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T16:23:04Z","timestamp":1791562984551,"version":"4.3.4"},"reference-count":20,"publisher":"MDPI AG","issue":"17","license":[{"start":{"date-parts":[[2025,9,4]],"date-time":"2025-09-04T00:00:00Z","timestamp":1756944000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Agencia Estatal de Investigaci\u00f3n","award":["PID2021-122486OA-I00"],"award-info":[{"award-number":["PID2021-122486OA-I00"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Background\/Objectives: The objective of this study is to compare the optical and visual quality provided by the advanced monofocal intraocular lens (IOL) ISOPure and the standard monofocal IOL MicroPure in cataract patients, using objective and subjective assessments. Methods: This prospective, single-blind clinical study includes 28 patients with cataracts, bilaterally implanted with either the ISOPure or MicroPure IOL. Eligible eyes had no ocular comorbidities and regular corneal astigmatism \u2264 1.00 D. Three months postoperatively, uncorrected distance and intermediate (UDVA, UIVA) and corrected distance and intermediate (CDVA, DCIVA) visual acuities were measured at 4 m, 80 cm, and 66 cm under photopic (85 cd\/m2) and mesopic (3.5 cd\/m2) conditions. Photic phenomena, including halo and glare, were evaluated. Objective optical quality was assessed using Objective Scattering Index (OSI), Modulation Transfer Function (MTF), Strehl Ratio (SR), and ocular aberrations. Subjective patient satisfaction was evaluated using Quality of Vision (QoV) and Catquest-9SF questionnaires. Results: Under photopic conditions, logMAR DCIVA at 80 cm, UIVA at 66 cm, and DCIVA at 66 cm were 0.18 \u00b1 0.06, 0.25 \u00b1 0.12, and 0.20 \u00b1 0.13, respectively, for ISOPure, and 0.22 \u00b1 0.06, 0.30 \u00b1 0.09, and 0.25 \u00b1 0.09 for MicroPure (p = 0.05, 0.02, and 0.05, respectively). No significant differences were observed in halo\/glare size or intensity, OSI, MTF, or SR. However, statistically significant differences were found in higher-order total aberrations for pupil sizes of 3.0, 4.0 mm, and 5.0 mm. Questionnaires indicated greater satisfaction and functional intermediate vision with ISOPure. Conclusions: The ISOPure IOL offers superior intermediate vision without compromising distance vision, delivering a balanced combination of optical quality, functional performance, and patient satisfaction.<\/jats:p>","DOI":"10.3390\/jcm14176255","type":"journal-article","created":{"date-parts":[[2025,9,5]],"date-time":"2025-09-05T07:46:17Z","timestamp":1757058377000},"page":"6255","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Advanced vs. Standard Monofocal IOLs: Optical Quality and Patient-Perceived Visual Outcomes"],"prefix":"10.3390","volume":"14","author":[{"given":"Carla","family":"Charbel","sequence":"first","affiliation":[{"name":"Optometry and Vision Department, Faculty of Optics and Optometry, Complutense University of Madrid, C\/Arcos de Jal\u00f3n, 118, 28037 Madrid, Spain"},{"name":"Miranza IOA Clinic, C\/Galileo, 104, 28003 Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lidia","family":"P\u00e9rez-Sanz","sequence":"additional","affiliation":[{"name":"Optometry and Vision Department, Faculty of Optics and Optometry, Complutense University of Madrid, C\/Arcos de Jal\u00f3n, 118, 28037 Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6162-0081","authenticated-orcid":false,"given":"Nuria","family":"Garz\u00f3n","sequence":"additional","affiliation":[{"name":"Optometry and Vision Department, Faculty of Optics and Optometry, Complutense University of Madrid, C\/Arcos de Jal\u00f3n, 118, 28037 Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco","family":"Poyales","sequence":"additional","affiliation":[{"name":"Miranza IOA Clinic, C\/Galileo, 104, 28003 Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2795-1802","authenticated-orcid":false,"given":"Jes\u00fas","family":"Carballo","sequence":"additional","affiliation":[{"name":"Optometry and Vision Department, Faculty of Optics and Optometry, Complutense University of Madrid, C\/Arcos de Jal\u00f3n, 118, 28037 Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,9,4]]},"reference":[{"key":"ref_1","first-page":"58","article-title":"The Evolution of Cataract Surgery","volume":"113","author":"Davis","year":"2016","journal-title":"Mo. Med."},{"key":"ref_2","unstructured":"Chang, D.F. (2017). The Continuing Evolution of Cataract Surgery. Asia Pac. J. Ophthalmol., 6."},{"key":"ref_3","unstructured":"(2018). Extended Depth of Focus Intraocular Lenses (Standard No. ANSI Z80.35.35-2018). Available online: https:\/\/webstore.ansi.org\/standards\/vc%20(asc%20z80)\/ansiz80352018."},{"key":"ref_4","unstructured":"Fern\u00e1ndez Guti\u00e9rrez, D., Barbero Briones, S., Dorronso D\u00edaz, C., and Marcos Celestino, S. (2013). Refractive Multifocal Intraocular Lens with Optimised Optical Quality in a Range of Focus and Method to Produce It. (EP2941222A1), European Patent."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1007\/s40123-021-00411-9","article-title":"Laboratory Investigation of Preclinical Visual-Quality Metrics and Halo-Size in Enhanced Monofocal Intraocular Lenses","volume":"10","author":"Labuz","year":"2021","journal-title":"Ophthalmol. Ther."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Alarcon, A., Canovas, C., Koopman, B., Pande, M.V., Koch, D.D., and Piers, P. (2023). Optical bench evaluation of the effect of pupil size in new generation monofocal intraocular lenses. BMC Ophthalmol., 23.","DOI":"10.1186\/s12886-023-02839-y"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"2231","DOI":"10.2147\/OPTH.S425352","article-title":"Prospective Randomized Single-Masked Study of Bilateral Isofocal Optic-Design or Monofocal Intraocular Lenses","volume":"17","author":"Ang","year":"2023","journal-title":"Clin. Ophthalmol."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Perez-Sanz, L., Gonzalez-Fernandez, V., Gomez-Pedrero, J.A., Albarran-Diego, C., Garcia-Montero, M., and Garzon, N. (2023). Optical and Clinical Outcomes of an Isofocal Intraocular Lens vs. a Monofocal Standard Lens. Life, 13.","DOI":"10.3390\/life13102001"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"182","DOI":"10.5301\/ejo.5001029","article-title":"A comparative study of the visual outcomes between a new trifocal and an extended depth of focus intraocular lens","volume":"28","year":"2018","journal-title":"Eur. J. Ophthalmol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"5303","DOI":"10.1364\/OL.38.005303","article-title":"Multifocal intraocular lens providing optimized through-focus performance","volume":"38","author":"Fernandez","year":"2013","journal-title":"Opt. Lett."},{"key":"ref_11","unstructured":"(2025, March 01). Isopure Technical Data. Available online: https:\/\/www.bvimedical.com\/wp-521content\/uploads\/2023\/02\/ISOPURE-Technical-Data-Sheet.pdf."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1271","DOI":"10.1016\/j.jcrs.2012.02.041","article-title":"Assessment of new-generation glistening-free hydrophobic acrylic intraocular lens material","volume":"38","author":"Pagnoulle","year":"2012","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1016\/j.ajo.2014.04.010","article-title":"Multifocal intraocular lens explantation: A case series of 50 eyes","volume":"158","author":"Kamiya","year":"2014","journal-title":"Am. J. Ophthalmol"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"15","DOI":"10.2174\/1874364101913010015","article-title":"Fast Measure of Visual Acuity and Contrast Sensitivity Defocus Curves with an iPad Application","volume":"13","author":"Tauste","year":"2019","journal-title":"Open Ophthalmol. J."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Ribeiro, F., Ferreira, T.B., Silva, D., Matos, A.C., Gaspar, S., and Pinero, D.P. (2023). Analysis of Daily Visual Habits in a Presbyopic Population. J. Ophthalmol., 2023.","DOI":"10.1155\/2023\/6440954"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.jcrs.2010.07.035","article-title":"Optical analysis, reading performance, and quality-of-life evaluation after implantation of a diffractive multifocal intraocular lens","volume":"37","author":"Alio","year":"2011","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"214","DOI":"10.4236\/ojoph.2021.113017","article-title":"Visual Performance of a Polynomial Extended Depth of Focus Intraocular Lens","volume":"11","author":"Stodulka","year":"2021","journal-title":"Open J. Ophthalmol."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Bova, A., and Vita, S. (2022). Clinical and Aberrometric Evaluation of a New Monofocal IOL with Intermediate Vision Improvement. J. Ophthalmol., 2022.","DOI":"10.1155\/2022\/4119698"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Mencucci, R., Morelli, A., Cennamo, M., Roszkowska, A.M., and Favuzza, E. (2023). Enhanced Monofocal Intraocular Lenses: A Retrospective, Comparative Study between Three Different Models. J. Clin. Med., 12.","DOI":"10.3390\/jcm12103588"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1111\/opo.13287","article-title":"Optical and aberrometric evaluation of a new enhanced monofocal intraocular lens with isofocal optic design","volume":"44","author":"Charbel","year":"2024","journal-title":"Ophthalmic Physiol. Opt."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/17\/6255\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T18:39:36Z","timestamp":1760035176000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/17\/6255"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,4]]},"references-count":20,"journal-issue":{"issue":"17","published-online":{"date-parts":[[2025,9]]}},"alternative-id":["jcm14176255"],"URL":"https:\/\/doi.org\/10.3390\/jcm14176255","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,4]]}}}