{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,27]],"date-time":"2026-06-27T21:52:58Z","timestamp":1782597178378,"version":"3.54.5"},"reference-count":28,"publisher":"MDPI AG","issue":"18","license":[{"start":{"date-parts":[[2025,9,18]],"date-time":"2025-09-18T00:00:00Z","timestamp":1758153600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Bausch and Lomb"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Background\/Objective: Contact lens discomfort (CLD) is a prevalent issue affecting up to 50% of wearers and contributes to discontinuation in approximately 30% of cases. This study aimed to evaluate the impact of refitting symptomatic monthly replacement contact lens (CL) wearers with a new daily, disposable contact lens (Kalifilcon A DDCL) and to compare its effectiveness against a placebo CL. Methods: Seventy-nine symptomatic wearers (CLDEQ-8 \u2265 12; mean age 27.07 \u00b1 8.38 years; 77% female) were recruited and randomly assigned to wear either Kalifilcon A DDCLs or placebo CLs. Participants were assessed at baseline and after one month of CL wear. Subjective measures included the CLDEQ-8 and the NEI VFQ-25 questionnaire. Objective assessments included tear film stability and ocular surface health. Statistical analysis was performed using paired t-tests and repeated-measures ANOVA. Bonferroni correction was applied for multiple comparisons, and results were reported with effect sizes (Cohen\u2019s d) and 95% confidence intervals. Statistical significance was set at p &lt; 0.05. Results: Kalifilcon A DDCL wearers showed a significant reduction in CLDEQ-8 scores (18.5 \u00b1 4.6 to 10.8 \u00b1 8.5; p &lt; 0.005; Cramer\u2019s V: 0.594; 95% CI: 13.35\u201315.34), with only 33% remaining symptomatic. Vision-related quality of life improved (75.83 \u00b1 8.0 to 83.5 \u00b1 8.6; p &lt; 0.005; Cramer\u2019s V: 0.977; 95% CI: 78.54\u201380.81), especially in ocular pain (p &lt; 0.001; Cramer\u2019s V: 0.755; 95% CI: 54.73\u201358.88), role difficulties (p &lt; 0.001; Cramer\u2019s V: 0.812; 95% CI: 35.12\u201342.77), and color vision (p &lt; 0.05; Cramer\u2019s V: 0.575; 95% CI: 93.07\u201395.63). Compared to the placebo CL, Kalifilcon A DDCLs led to greater improvements in comfort (p &lt; 0.0001; Cramer\u2019s V: 0.329; 95% CI: 7.22\u20137.74), visual acuity (p &lt; 0.0001; Cramer\u2019s V: 0.267; 95% CI: 7.38\u20137.85), and satisfaction (p = 0.005; Cramer\u2019s V: 0.208; 95% CI: 7.70\u20138.18). Tear film stability also improved significantly (p &lt; 0.05), with no changes observed in the placebo group. Conclusions: Refitting symptomatic CL wearers with Kalifilcon A DDCLs significantly improves comfort, reduces CLD symptoms, and enhances vision-related quality of life. These results support its use as a beneficial alternative to monthly CLs in symptomatic individuals.<\/jats:p>","DOI":"10.3390\/jcm14186575","type":"journal-article","created":{"date-parts":[[2025,9,18]],"date-time":"2025-09-18T14:45:46Z","timestamp":1758206746000},"page":"6575","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["A Randomized Trial on the Benefits of Refitting Symptomatic Contact Lens Wearers with Daily Disposable Lenses"],"prefix":"10.3390","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-5543-4684","authenticated-orcid":false,"given":"Jos\u00e9 Miguel","family":"S\u00e1nchez-Ruiz","sequence":"first","affiliation":[{"name":"Grupo de Investigaci\u00f3n Optometr\u00eda Cl\u00ednica y Experimental, Facultad de \u00d3ptica y Optometr\u00eda, Universidad de Murcia, 30100 Murcia, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A. Eusebio","family":"L\u00f3pez-Hern\u00e1ndez","sequence":"additional","affiliation":[{"name":"Grupo de Investigaci\u00f3n Optometr\u00eda Cl\u00ednica y Experimental, Facultad de \u00d3ptica y Optometr\u00eda, Universidad de Murcia, 30100 Murcia, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Youssef","family":"Abidi","sequence":"additional","affiliation":[{"name":"Grupo de Investigaci\u00f3n Optometr\u00eda Cl\u00ednica y Experimental, Facultad de \u00d3ptica y Optometr\u00eda, Universidad de Murcia, 30100 Murcia, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9124-9247","authenticated-orcid":false,"given":"Johnny","family":"Di Pierdomenico","sequence":"additional","affiliation":[{"name":"Grupo de Investigaci\u00f3n Optometr\u00eda Cl\u00ednica y Experimental, Facultad de \u00d3ptica y Optometr\u00eda, Universidad de Murcia, 30100 Murcia, Spain"},{"name":"Grupo de Investigaci\u00f3n Oftalmolog\u00eda Experimental, Departamento de Oftalmolog\u00eda, Optometr\u00eda, Otorrinolaringolog\u00eda y Anatom\u00eda Patol\u00f3gica, Facultad de Medicina, Instituto Murciano de Investigaci\u00f3n Biosanitaria Pascual Parrilla-IMIB, Universidad de Murcia, 30120 Murcia, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7639-5366","authenticated-orcid":false,"given":"Diego","family":"Garc\u00eda-Ayuso","sequence":"additional","affiliation":[{"name":"Grupo de Investigaci\u00f3n Optometr\u00eda Cl\u00ednica y Experimental, Facultad de \u00d3ptica y Optometr\u00eda, Universidad de Murcia, 30100 Murcia, Spain"},{"name":"Grupo de Investigaci\u00f3n Oftalmolog\u00eda Experimental, Departamento de Oftalmolog\u00eda, Optometr\u00eda, Otorrinolaringolog\u00eda y Anatom\u00eda Patol\u00f3gica, Facultad de Medicina, Instituto Murciano de Investigaci\u00f3n Biosanitaria Pascual Parrilla-IMIB, Universidad de Murcia, 30120 Murcia, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,9,18]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"101579","DOI":"10.1016\/j.clae.2022.101579","article-title":"Exploring the factors which impact overall satisfaction with single vision contact lenses","volume":"45","author":"Guthrie","year":"2022","journal-title":"Contact Lens Anterior Eye"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1097\/ICL.0b013e3182480e97","article-title":"Quality of life of myopic subjects with different methods of visual correction using the NEI RQL-42 questionnaire","volume":"38","author":"Queiros","year":"2012","journal-title":"Eye Contact Lens"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"TFOS20","DOI":"10.1167\/iovs.13-13125","article-title":"The TFOS International Workshop on Contact Lens Discomfort: Report of the subcommittee on epidemiology","volume":"54","author":"Dumbleton","year":"2013","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"85","DOI":"10.2147\/OPTO.S198637","article-title":"A Review of Contact Lens Dropout","volume":"12","author":"Pucker","year":"2020","journal-title":"Clin. Optom."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"102096","DOI":"10.1016\/j.clae.2023.102096","article-title":"Clinical characterisation of contact lens discomfort progression","volume":"47","year":"2024","journal-title":"Contact Lens Anterior Eye"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"TFOS7","DOI":"10.1167\/iovs.13-13212","article-title":"The TFOS International Workshop on Contact Lens Discomfort: Executive summary","volume":"54","author":"Nichols","year":"2013","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"101521","DOI":"10.1016\/j.clae.2021.101521","article-title":"Quality-of-life outcomes of long-term contact lens wear: A systematic review","volume":"45","author":"Kandel","year":"2022","journal-title":"Contact Lens Anterior Eye"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1097\/OPX.0b013e318269c90d","article-title":"Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8) and opinion of contact lens performance","volume":"89","author":"Chalmers","year":"2012","journal-title":"Optom. Vis. Sci."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1097\/ICL.0000000000000727","article-title":"Contact Lens Discomfort Management: Outcomes of Common Interventions","volume":"47","author":"Fernandez","year":"2021","journal-title":"Eye Contact Lens"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"101370","DOI":"10.1016\/j.clae.2020.09.003","article-title":"Does placebo effect exist in contact lens discomfort management?","volume":"44","author":"Fernandez","year":"2021","journal-title":"Contact Lens Anterior Eye"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"686","DOI":"10.1111\/opo.13299","article-title":"Refitting contact lens dropouts into a modern daily disposable contact lens","volume":"44","author":"Lievens","year":"2024","journal-title":"Ophthalmic Physiol. Opt."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"The WHOQOL Group (1995). The World Health Organization Quality of Life assessment (WHOQOL): Position paper from the World Health Organization. Soc. Sci. Med., 41, 1403\u20131409.","DOI":"10.1016\/0277-9536(95)00112-K"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1001\/archopht.119.7.1050","article-title":"Development of the 25-item National Eye Institute Visual Function Questionnaire","volume":"119","author":"Mangione","year":"2001","journal-title":"Arch. Ophthalmol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1136\/jnnp.2003.010678","article-title":"The use of contact lenses to treat visually symptomatic congenital nystagmus","volume":"75","author":"Biousse","year":"2004","journal-title":"J. Neurol. Neurosurg. Psychiatry"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"830","DOI":"10.1080\/08164622.2024.2422473","article-title":"Vision-related quality of life and near-work visual symptoms in patients with attention-deficit\/hyperactivity disorder","volume":"108","year":"2025","journal-title":"Clin. Exp. Optom."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Okumura, Y., Inomata, T., Iwata, N., Sung, J., Fujimoto, K., Fujio, K., Midorikawa-Inomata, A., Miura, M., Akasaki, Y., and Murakami, A. (2020). A Review of Dry Eye Questionnaires: Measuring Patient-Reported Outcomes and Health-Related Quality of Life. Diagnostics, 10.","DOI":"10.3390\/diagnostics10080559"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Rajabpour, M., Kangari, H., Pesudovs, K., Khorrami-Nejad, M., Rahmani, S., Mohaghegh, S., and Moradnejad, S. (2024). Refractive error and vision related quality of life. BMC Ophthalmol., 24.","DOI":"10.1186\/s12886-024-03350-8"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.clae.2018.10.015","article-title":"Translation and validation of the contact lens dry eye questionnaire-8 (CLDEQ-8) to the Spanish language","volume":"42","author":"Amparo","year":"2019","journal-title":"Contact Lens Anterior Eye"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1016\/j.jtos.2017.05.001","article-title":"TFOS DEWS II Diagnostic Methodology report","volume":"15","author":"Wolffsohn","year":"2017","journal-title":"Ocul. Surf."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1062","DOI":"10.1111\/opo.13024","article-title":"Short-term tear film stability, optical quality and visual performance in two dual-focus contact lenses for myopia control with different optical designs","volume":"42","author":"McAlinden","year":"2022","journal-title":"Ophthalmic Physiol. Opt."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"876","DOI":"10.1111\/opo.13328","article-title":"Assessing neophyte response to daily disposable silicone hydrogel contact lenses: A randomised clinical trial investigation over one month","volume":"44","author":"Giraldez","year":"2024","journal-title":"Ophthalmic Physiol. Opt."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1016\/j.clae.2016.04.005","article-title":"Cutoff score and responsiveness of the 8-item Contact Lens Dry Eye Questionnaire (CLDEQ-8) in a Large daily disposable contact lens registry","volume":"39","author":"Chalmers","year":"2016","journal-title":"Contact Lens Anterior Eye"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"3235","DOI":"10.2147\/OPTH.S429237","article-title":"Comfort After Refitting Symptomatic Habitual Reusable Toric Lens Wearers with a New Daily Disposable Contact Lens for Astigmatism","volume":"17","author":"Wan","year":"2023","journal-title":"Clin. Ophthalmol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1080\/08164622.2024.2432449","article-title":"Visual performance and quality of life in myopic adolescents with pupil-optimised multifocal versus single-vision contact lenses","volume":"108","author":"Yapici","year":"2025","journal-title":"Clin. Exp. Optom."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"102385","DOI":"10.1016\/j.clae.2025.102385","article-title":"Cost and benefits of availing specialty contact lenses for irregular cornea and ocular surface diseases from patient perspectives","volume":"48","author":"Balaji","year":"2025","journal-title":"Contact Lens Anterior Eye"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1111\/cxo.12597","article-title":"Tear film evaluation and management in soft contact lens wear: A systematic approach","volume":"100","author":"Downie","year":"2017","journal-title":"Clin. Exp. Optom."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1080\/08164622.2021.1945411","article-title":"Assessment of dry eye symptoms among university students during the COVID-19 pandemic","volume":"105","year":"2022","journal-title":"Clin. Exp. Optom."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1097\/OPX.0000000000000866","article-title":"Association Between Contact Lens Discomfort and Pre-lens Tear Film Kinetics","volume":"93","author":"Guillon","year":"2016","journal-title":"Optom. Vis. Sci."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/18\/6575\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T18:48:26Z","timestamp":1760035706000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/18\/6575"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,18]]},"references-count":28,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2025,9]]}},"alternative-id":["jcm14186575"],"URL":"https:\/\/doi.org\/10.3390\/jcm14186575","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,18]]}}}