{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T01:01:50Z","timestamp":1787619710913,"version":"build-2736575974"},"reference-count":35,"publisher":"MDPI AG","issue":"21","license":[{"start":{"date-parts":[[2025,10,24]],"date-time":"2025-10-24T00:00:00Z","timestamp":1761264000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Objectives: To establish normative data for anterior segment parameters in healthy pediatric and adult populations using swept-source optical coherence tomography (SS-OCT), and to evaluate the influence of age and sex on these parameters. Methods: This retrospective study included the right eyes of 390 healthy participants. Subjects were divided into three age groups: Group 1 (6\u201317 years, n = 97), Group 2 (18\u201345 years, n = 144), and Group 3 (46\u201377 years, n = 149). All patients were categorized according to their biological sex as female and male. Exclusion criteria were corneal pathology, prior intraocular\/refractive surgery, recent contact lens use, severe dry eye, ectatic disorders, low-quality imaging, and refractive error of \u00b12.0 D or greater. Measurements of anterior and posterior keratometry, total corneal power (TCP), central corneal thickness (CCT), thinnest corneal thickness (TCT), pupil diameter (PD), lens thickness (LT), and white-to-white distance (WTW) were obtained using the Anterion\u00ae SS-OCT system. Data were analyzed using SPSS software. Results: Group 1 demonstrated the highest PD and CCT values, whereas LT was lowest. In adults, LT increased with age and was significantly higher in males older than 45 years. Keratometric analysis revealed greater anterior and total steep astigmatism in the pediatric group, independent of sex. Adult females had significantly higher anterior and posterior keratometry values compared with males. In the pediatric cohort, females exhibited greater CCT, while WTW varied with age. PD decreased with age, whereas LT increased. Conclusions: Anterior segment parameters measured with SS-OCT show significant variations across different age groups and between sexes. Normative data, particularly for pediatric and adult populations, may serve as valuable reference values in keratorefractive surgical planning and corneal pathology assessment. Future studies with larger cohorts, especially in pediatric populations, are warranted.<\/jats:p>","DOI":"10.3390\/jcm14217558","type":"journal-article","created":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T09:16:24Z","timestamp":1761729384000},"page":"7558","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Age- and Sex-Related Normative Anterior Segment Parameters Using Swept-Source OCT: Insights from Pediatric to Elderly Populations"],"prefix":"10.3390","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5371-1373","authenticated-orcid":false,"given":"Hatice Kubra","family":"Sonmez","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Medical Faculty, Erciyes University, Kayseri 38039, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3015-2158","authenticated-orcid":false,"given":"Zeynep","family":"Akkul","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Bursa Yuksek Ihtisas Training and Research Hospital, Bursa 16310, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5836-0170","authenticated-orcid":false,"given":"Hidayet","family":"Sener","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Medical Faculty, Erciyes University, Kayseri 38039, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erinc","family":"Buyukpat\u0131r Deneme","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Develi Dr. Ekrem Karakaya State Hospital, Kayseri 38400, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elif","family":"Er Arslantas","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Viransehir State Hospital, Sanl\u0131urfa 63700, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7889-4532","authenticated-orcid":false,"given":"Cem","family":"Evereklioglu","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Maya Eye Hospital, Kayseri 38230, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1442-6032","authenticated-orcid":false,"given":"Fatih","family":"Horozoglu","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Medical Faculty, Erciyes University, Kayseri 38039, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Osman Ahmet","family":"Polat","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Medical Faculty, Erciyes University, Kayseri 38039, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hatice","family":"Arda","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Medical Faculty, Erciyes University, Kayseri 38039, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,10,24]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1136\/bjo.2006.103408","article-title":"Recent advances in ophthalmic anterior segment imaging: A new era for ophthalmic diagnosis?","volume":"91","author":"Konstantopoulos","year":"2007","journal-title":"Br. J. Ophthalmol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1626","DOI":"10.1016\/j.jcrs.2012.04.031","article-title":"Scheimpflug-Placido topographer and optical low-coherence reflectometry biometer: Repeatability and agreement","volume":"38","author":"Chen","year":"2012","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1658","DOI":"10.1016\/j.jcrs.2014.11.051","article-title":"Comparison of corneal power, astigmatism, and wavefront aberration measurements obtained by a point-source color light-emitting diode-based topographer, a Placido-disk topographer, and a combined Placido and dual Scheimpflug device","volume":"41","author":"Ventura","year":"2015","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"362","DOI":"10.3928\/1081597X-20190422-02","article-title":"Prediction Accuracy of Total Keratometry Compared to Standard Keratometry Using Different Intraocular Lens Power Formulas","volume":"35","author":"Fabian","year":"2019","journal-title":"J. Refract. Surg."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1111\/ceo.13760","article-title":"Total keratometry in intraocular lens power calculations in eyes with previous laser refractive surgery","volume":"48","author":"Lawless","year":"2020","journal-title":"Clin. Exp. Ophthalmol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1016\/j.jcrs.2015.11.036","article-title":"Effect of posterior corneal astigmatism on power calculation and alignment of toric intraocular lenses: Comparison of methodologies","volume":"42","author":"Reitblat","year":"2016","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1167\/iovs.14-15903","article-title":"An analysis of the factors influencing the residual refractive astigmatism after cataract surgery with toric intraocular lenses","volume":"56","author":"Savini","year":"2015","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1140","DOI":"10.1016\/j.jcrs.2017.06.040","article-title":"Optimized keratometry and total corneal astigmatism for toric intraocular lens calculation","volume":"43","author":"Savini","year":"2017","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1007\/s00417-019-04570-1","article-title":"Comparing refractive outcomes of a standard industry toric IOL calculator using anterior corneal astigmatism and total corneal refractive power","volume":"258","author":"Kern","year":"2020","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.1097\/DSS.0000000000000485","article-title":"Applications of the Excimer Laser: A Review","volume":"41","author":"Beggs","year":"2015","journal-title":"Dermatol. Surg."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"734","DOI":"10.3928\/1081597X-20131021-02","article-title":"Pupil size and LASIK: A review","volume":"29","author":"Myung","year":"2013","journal-title":"J. Refract. Surg."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/j.jcrs.2004.09.043","article-title":"Corneal power, thickness, and stiffness: Results of a prospective randomized controlled trial of PRK and LASIK for myopia","volume":"31","author":"Hjortdal","year":"2005","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_13","first-page":"105","article-title":"Advances in corneal imaging: Current applications and beyond","volume":"8","author":"Shih","year":"2019","journal-title":"Asia-Pac. J. Ophthalmol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1111\/ceo.13136","article-title":"Applications of corneal topography and tomography: A review","volume":"46","author":"Fan","year":"2018","journal-title":"Clin. Exp. Ophthalmol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1097\/ICO.0000000000001133","article-title":"Noncontact evaluation of corneal grafts: Swept-source Fourier domain OCT versus high-resolution Scheimpflug imaging","volume":"36","author":"Szalai","year":"2017","journal-title":"Cornea"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"e486","DOI":"10.1111\/aos.13298","article-title":"Comparison of corneal measurements in keratoconus using swept-source optical coherence tomography and combined Placido-Scheimpflug imaging","volume":"95","author":"Chan","year":"2017","journal-title":"Acta Ophthalmol."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Asam, J.S., Polzer, M., Tafreshi, A., Hirnschall, N., and Findl, O. (2019). Anterior segment OCT. High Resolution Imaging in Microscopy and Ophthalmology: New Frontiers in Biomedical Optics, Springer.","DOI":"10.1007\/978-3-030-16638-0_13"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"e000058","DOI":"10.1136\/bmjophth-2016-000058","article-title":"In vivo crystalline lens measurements with novel swept-source optical coherent tomography: An investigation on variability of measurement","volume":"1","author":"Shoji","year":"2017","journal-title":"BMJ Open Ophthalmol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1111\/opo.13151","article-title":"Monochromatic ocular high-order aberrations in children and adolescents","volume":"43","author":"Rauscher","year":"2023","journal-title":"Ophthalmic Physiol. Opt."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Lu, T., Song, J., Wu, Q., Jiang, W., Tian, Q., Zhang, X., Xu, J., Wu, J., Hu, Y., and Sun, W. (2021). Refractive lens power and lens thickness in children (6\u201316 years old). Sci. Rep., 11.","DOI":"10.1038\/s41598-021-98817-9"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/S2352-4642(18)30022-1","article-title":"The age of adolescence","volume":"2","author":"Sawyer","year":"2018","journal-title":"Lancet Child Adolesc. Health"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"9520512","DOI":"10.1155\/2022\/9520512","article-title":"Distribution of Pupil Size and Associated Factors: Results from the Population-Based Gutenberg Health Study","volume":"2022","author":"Kiel","year":"2022","journal-title":"J. Ophthalmol."},{"key":"ref_23","first-page":"1132","article-title":"Factors affecting light-adapted pupil size in normal human subjects","volume":"35","author":"Winn","year":"1994","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_24","first-page":"505","article-title":"Corneal white-to-white distance and mesopic pupil diameter","volume":"5","author":"Cakmak","year":"2012","journal-title":"Int. J. Ophthalmol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1111\/j.1442-9071.2012.02760.x","article-title":"Lens thickness and associated factors","volume":"40","author":"Jonas","year":"2012","journal-title":"Clin. Exp. Ophthalmol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1097\/j.jcrs.0000000000000693","article-title":"Effect of age and cycloplegia on the morphology of the human crystalline lens: Swept-source OCT study","volume":"48","author":"Li","year":"2022","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1007\/s10384-024-01126-7","article-title":"Associations of ocular anterior segment structures with sex and age: The Yamagata study (Funagata)","volume":"68","author":"Namba","year":"2024","journal-title":"Jpn. J. Ophthalmol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1097\/00003226-200104000-00007","article-title":"Gender- and age-related differences in corneal topography","volume":"20","author":"Goto","year":"2001","journal-title":"Cornea"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1167\/8.4.29","article-title":"Age-related changes in optical and biometric characteristics of emmetropic eyes","volume":"8","author":"Atchison","year":"2008","journal-title":"J. Vis."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.ajo.2021.06.032","article-title":"Ocular Biometric Characteristics Measured by Swept-Source Optical Coherence Tomography in Individuals Undergoing Cataract Surgery","volume":"233","author":"Wasser","year":"2022","journal-title":"Am. J. Ophthalmol."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1167\/iovs.14-15659","article-title":"Anterior Surface-Based Keratometry Compared with Scheimpflug Tomography-Based Total Corneal Astigmatism","volume":"56","author":"Tonn","year":"2015","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1016\/j.ophtha.2015.01.021","article-title":"Corneal Thickness Profile and Posterior Corneal Astigmatism in Normal Corneas","volume":"122","author":"Ueno","year":"2015","journal-title":"Ophthalmology"},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Almor\u00edn-Fern\u00e1ndez-Vigo, I., S\u00e1nchez-Guill\u00e9n, I., Fern\u00e1ndez-Vigo, J.I., Burgos-Blasco, B., De-Pablo-G\u00f3mez-de-Lia\u00f1o, L., Fern\u00e1ndez-Vigo, J.\u00c1., and Macarro-Merino, A. (2023). Normative Topographic Anterior and Posterior Corneal Astigmatism: Axis Distribution and Its Relations with Ocular and Biometric Parameters. J. Clin. Med., 12.","DOI":"10.3390\/jcm12113664"},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Xie, X., Corradetti, G., Song, A., Pardeshi, A., Sultan, W., Lee, J.Y., Yu, F., Zhang, L., Chen, S., and Chopra, V. (2020). Age- and refraction-related changes in anterior segment anatomical structures measured by swept-source anterior segment OCT. PLoS ONE, 15.","DOI":"10.1371\/journal.pone.0240110"},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Schiano-Lomoriello, D., Hoffer, K.J., Abicca, I., and Savini, G. (2021). Repeatability of automated measurements by a new anterior segment optical coherence tomographer and biometer and agreement with standard devices. Sci. Rep., 11.","DOI":"10.1038\/s41598-020-79674-4"}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/21\/7558\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T09:47:32Z","timestamp":1761731252000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/21\/7558"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,24]]},"references-count":35,"journal-issue":{"issue":"21","published-online":{"date-parts":[[2025,11]]}},"alternative-id":["jcm14217558"],"URL":"https:\/\/doi.org\/10.3390\/jcm14217558","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,24]]}}}