{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T12:51:55Z","timestamp":1790772715204,"version":"4.1.0"},"reference-count":59,"publisher":"MDPI AG","issue":"21","license":[{"start":{"date-parts":[[2025,10,25]],"date-time":"2025-10-25T00:00:00Z","timestamp":1761350400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"VICTOR BABES UNIVERSITY OF MEDICINE AND PHARMACY TIMI\u0218OARA"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Background\/Objectives: This study aims to investigate the correlation between vertical facial dimensions, lip morphology, angular facial parameters, and demographic variables (age and sex) in Romanian orthodontic patients, using structured-light 3D facial scanning technology. Methods: This cross-sectional study assessed craniofacial soft tissue parameters in 90 Romanian orthodontic patients (57 females, 33 males; median age 14 years) using the MetiSmile 3D facial scanner. Measurements included vertical facial heights (upper, middle, and lower), total facial height, facial proportion indices, lip lengths, interpupillary distance, bizygomatic width, mouth width, angular parameters (nasofrontal, nasolabial, mentolabial, and facial angles), and distances from the lips to the esthetic (E) line. Spearman\u2019s rank correlation and Mann\u2013Whitney U-tests were applied for statistical analysis. Results: A total of 90 subjects (63.3% female; median age, 14 years [range: 9\u201327 years]) were evaluated. Age showed strong positive correlations with total facial height (\u03c1 = 0.690), middle (\u03c1 = 0.631), and lower facial height (\u03c1 = 0.615), while upper facial height had a weaker correlation (\u03c1 = 0.334). Upper and lower lip lengths were moderately correlated with each other and with bizygomatic and interpupillary widths. Vertical facial proportion indices reflected distinct associations with their respective facial segments. Sex-based analysis revealed that females had significantly greater middle and total facial heights and nasofrontal angles, while males exhibited larger nasolabial angles. Upper lip protrusion relative to the E-line was significantly more pronounced in females (p = 0.041). No significant sex differences were noted in lip dimensions or transverse widths. Conclusions: The research demonstrates the value of 3D structured-light facial scanning in orthodontics as a non-invasive, radiation-free method for evaluating age- and sex-related morphological patterns. These findings support the integration of facial morphometric analysis into individualized diagnostic and treatment workflows in clinical orthodontics.<\/jats:p>","DOI":"10.3390\/jcm14217578","type":"journal-article","created":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T09:16:24Z","timestamp":1761729384000},"page":"7578","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Advanced 3D Facial Scanning in Orthodontics: A Correlative Analysis of Craniofacial Anthropometric Parameters"],"prefix":"10.3390","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-5432-1026","authenticated-orcid":false,"given":"Andra-Alexandra","family":"St\u0103ncioiu","sequence":"first","affiliation":[{"name":"Orthodontic Research Center ORTHO-CENTER, Discipline of Orthodontics I, Faculty of Dental Medicine, \u201cVictor Babes\u201d University of Medicine and Pharmacy Timisoara, 9 No., Revolutiei Bv., 300041 Timisoara, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandru C\u0103t\u0103lin","family":"Motofelea","sequence":"additional","affiliation":[{"name":"Center for Molecular Research in Nephrology and Vascular Disease, Discipline of Nephrology, Department VII\/Internal Medicine II, Faculty of Medicine, \u201cVictor Babes\u201d University of Medicine and Pharmacy, 300041 Timisoara, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adelina","family":"Popa","sequence":"additional","affiliation":[{"name":"Orthodontic Research Center ORTHO-CENTER, Discipline of Orthodontics I, Faculty of Dental Medicine, \u201cVictor Babes\u201d University of Medicine and Pharmacy Timisoara, 9 No., Revolutiei Bv., 300041 Timisoara, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4129-0505","authenticated-orcid":false,"given":"Riham","family":"Nagib","sequence":"additional","affiliation":[{"name":"Orthodontic Research Center ORTHO-CENTER, Discipline of Orthodontics I, Faculty of Dental Medicine, \u201cVictor Babes\u201d University of Medicine and Pharmacy Timisoara, 9 No., Revolutiei Bv., 300041 Timisoara, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rare\u0219-Bogdan","family":"Lung","sequence":"additional","affiliation":[{"name":"Orthodontic Research Center ORTHO-CENTER, Discipline of Orthodontics I, Faculty of Dental Medicine, \u201cVictor Babes\u201d University of Medicine and Pharmacy Timisoara, 9 No., Revolutiei Bv., 300041 Timisoara, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3668-2299","authenticated-orcid":false,"given":"Camelia","family":"Szuhanek","sequence":"additional","affiliation":[{"name":"Orthodontic Research Center ORTHO-CENTER, Discipline of Orthodontics I, Faculty of Dental Medicine, \u201cVictor Babes\u201d University of Medicine and Pharmacy Timisoara, 9 No., Revolutiei Bv., 300041 Timisoara, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,10,25]]},"reference":[{"key":"ref_1","first-page":"e81662","article-title":"Facial Scans in Clinical Dentistry and Related Research: A Scoping Review","volume":"17","author":"Shuto","year":"2025","journal-title":"Cureus"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"664","DOI":"10.3390\/prosthesis4040053","article-title":"Facial Scanners in Dentistry: An Overview","volume":"4","author":"Lee","year":"2022","journal-title":"Prosthesis"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Mangano, F., Gandolfi, A., Luongo, G., and Logozzo, S. (2017). Intraoral scanners in dentistry: A review of the current literature. BMC Oral Health, 17.","DOI":"10.1186\/s12903-017-0442-x"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"381","DOI":"10.4047\/jap.2017.9.5.381","article-title":"Integrating 3D facial scanning in a digital workflow to CAD\/CAM design and fabricate complete dentures for immediate total mouth rehabilitation","volume":"9","author":"Hassan","year":"2017","journal-title":"J. Adv. Prosthodont."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1016\/j.prosdent.2018.01.015","article-title":"Accuracy of digital technologies for the scanning of facial, skeletal, and intraoral tissues: A systematic review","volume":"121","author":"Bohner","year":"2019","journal-title":"J. Prosthet. Dent."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Zhao, Y.J., Xiong, Y.X., and Wang, Y. (2017). Three-Dimensional Accuracy of Facial Scan for Facial Deformities in Clinics: A New Evaluation Method for Facial Scanner Accuracy. PLoS ONE, 12.","DOI":"10.1371\/journal.pone.0169402"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Amornvit, P., and Sanohkan, S. (2019). The Accuracy of Digital Face Scans Obtained from 3D Scanners: An In Vitro Study. Int. J. Environ. Res. Public Health, 16.","DOI":"10.3390\/ijerph16245061"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1111\/clr.12379","article-title":"The virtual patient in dental medicine","volume":"26","author":"Joda","year":"2015","journal-title":"Clin. Oral Implants. Res."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Thurzo, A., Strunga, M., Havl\u00ednov\u00e1, R., Reh\u00e1kov\u00e1, K., Urban, R., Surovkov\u00e1, J., and Kurilov\u00e1, V. (2022). Smartphone-Based Facial Scanning as a Viable Tool for Facially Driven Orthodontics?. Sensors, 22.","DOI":"10.20944\/preprints202209.0220.v1"},{"key":"ref_10","unstructured":"Crumpler, W. (2025, May 03). How Accurate Are Facial Recognition Systems\u2013and Why Does It Matter? Center for Strategic and International Studies. Available online: https:\/\/www.csis.org\/blogs\/strategic-technologies-blog\/how-accurate-are-facial-recognition-systems-and-why-does-it."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"105553","DOI":"10.1016\/j.jdent.2024.105553","article-title":"Clinical Evaluation of the Accuracy of Two Face Scanners with Different Scanning Technologies","volume":"153","author":"Srinivasan","year":"2025","journal-title":"J. Dent."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"cjae056","DOI":"10.1093\/ejo\/cjae056","article-title":"Patch-Based Convolutional Neural Networks for Automatic Landmark Detection of 3D Facial Images in Clinical Settings","volume":"46","author":"Ayoub","year":"2024","journal-title":"Eur. J. Orthod."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Barone, S., Antonelli, A., Salviati, M., Greco, V., Bennardo, F., Becker, K., Giudice, A., and Simeone, M. (2024). Accuracy Assessment of EM3D App-Based 3D Facial Scanning Compared to Cone Beam Computed Tomography. Dent. J., 12.","DOI":"10.3390\/dj12110342"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"112282","DOI":"10.1016\/j.forsciint.2024.112282","article-title":"Analyzing 3D Facial Morphology: Insights from a Comparative European and South African Study on Population Affinity, Sex, Age, and Allometry","volume":"365","author":"Mbonani","year":"2024","journal-title":"Forensic Sci. Int."},{"key":"ref_15","first-page":"180","article-title":"Demographic Differences in Facial Anthropometric Data from 3D Scans and Implications for Respirator Fit","volume":"22","author":"Brazile","year":"2025","journal-title":"Int. J. Environ. Res. Public Health"},{"key":"ref_16","first-page":"1623","article-title":"Ethnic Variation in Lower Face Anthropometry on Facial Computed Tomography Scans for Patients Seeking Facial Feminization Surgery","volume":"77","author":"Nguyen","year":"2024","journal-title":"J. Plast. Reconstr. Aesthet. Surg."},{"key":"ref_17","unstructured":"Shining 3D (2025, May 22). MetiSmile\u2014Dental Facial Scanner. Available online: https:\/\/www.shining3ddental.com\/solution\/metismile-face-scanner\/."},{"key":"ref_18","first-page":"510","article-title":"Anthropometric Precision and Accuracy of Digital Three-Dimensional Photogrammetry: Comparing the 3dMDface System with Direct Anthropometry and 2D Photographs","volume":"43","author":"Weinberg","year":"2006","journal-title":"Cleft Palate Craniofac. J."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Choi, M.-H., Lee, S.-J., Yang, H.J., Huh, K.-H., Lee, S.-S., Heo, M.-S., Choi, S.-C., Hwang, S.J., and Yi, W.-J. (2020). Automatic Reproduction of Natural Head Position Using a Portable 3D Scanner Based on Immediate Calibration. Appl. Sci., 10.","DOI":"10.3390\/app10010174"},{"key":"ref_20","unstructured":"Dentstore (2025, May 22). Scanner Facial MetiSmile Shining 3D. Available online: https:\/\/dentstore.ro\/scanner-cabinet\/537918-scanner-facial-metismile-shining-3d-12.html?srsltid=AfmBOoqXRNxS1ftZHJqkiKlHBo5h6NPnz_KOC47MG-k7wDSzl1Fqlu_f."},{"key":"ref_21","unstructured":"Shining 3D (2023). MetiSmile User Manual: 3D Facial Scanner Instructions, Shining 3D Tech Co., Ltd.. Available online: https:\/\/www.shining3d.com."},{"key":"ref_22","first-page":"2","article-title":"Measurements of Lower, Middle, and Upper Facial Heights in Different Sex in a Teaching Hospital of Biratnagar","volume":"18","author":"Rathi","year":"2018","journal-title":"J. Nepal Dent. Assoc."},{"key":"ref_23","first-page":"1","article-title":"Complexities in Diagnosis and Management of Long Face","volume":"2","author":"George","year":"2018","journal-title":"J. Contemp. Orthod."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/B978-0-323-03684-9.50011-6","article-title":"Flap Classification and Design","volume":"Volume 1","author":"Baker","year":"2007","journal-title":"Local Flaps in Facial Reconstruction"},{"key":"ref_25","first-page":"1","article-title":"The Relationship between the Lip Length and Smile Line in a Malaysian Population: A Cross-Sectional Study","volume":"3","author":"Wen","year":"2017","journal-title":"Dent. Oral Craniofac. Res."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1055\/s-0039-1698360","article-title":"Evaluation of Smile Parameters in Nongrowing Subjects Using Photographs","volume":"7","author":"Bhullar","year":"2019","journal-title":"Dent. J. Adv. Stud."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1046\/j.1475-1313.1999.00441.x","article-title":"The Far Interpupillary Distance. A Gender-Specific Variation with Advancing Age","volume":"19","author":"Pointer","year":"1999","journal-title":"Ophthalmic Physiol. Opt."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Caton, N.R., and Dixson, B.J. (2022). Beyond Facial Width-to-Height Ratios: Bizygomatic Width Is Highly Sexually Dimorphic When Adjusting for Allometry. Biol. Lett., 18.","DOI":"10.1098\/rsbl.2022.0211"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1055\/s-0036-1584234","article-title":"Nasofrontal Angle and Nasal Dorsal Aesthetics: A Quantitative Investigation of Idealized and Normative Values","volume":"32","author":"Naini","year":"2016","journal-title":"Facial Plast. Surg."},{"key":"ref_30","unstructured":"Szuhanek, C., Schiller, A., Grigore, A., and Popa, L. (2019). Ghid Ortodon\u021bie, Editura Victor Babe\u0219."},{"key":"ref_31","first-page":"17","article-title":"Anthropometric Study of Inter-Alar Width and Mouth Width Measurements among Nigerians of Delta State Extraction","volume":"7","author":"Uche","year":"2020","journal-title":"Eur. J. Biomed."},{"key":"ref_32","first-page":"163","article-title":"Mentolabial Angle and Aesthetic Preference","volume":"28","author":"Naini","year":"2017","journal-title":"J. Craniofac. Surg."},{"key":"ref_33","first-page":"101","article-title":"Evaluation of the Variation of Skeletofacial Angles (Facial, Mandibular, and Gonial Angles) among the Pubertal Age Groups: A Cephalometric Study","volume":"19","author":"Obaidi","year":"2007","journal-title":"Sci. J. Publ."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1186\/s13005-015-0080-y","article-title":"Influence of Maxillary Advancement Surgery on Skeletal and Soft-Tissue Changes in the Nose\u2014A Retrospective Cone-Beam Computed Tomography Study","volume":"11","author":"Hellak","year":"2015","journal-title":"Head Face Med."},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Schiller, L.A., Barbu, H.M., Iancu, S.A., and Brad, S. (2022). Incidence, Size and Orientation of Maxillary Sinus Septa\u2014A Retrospective Clinical Study. J. Clin. Med., 11.","DOI":"10.3390\/jcm11092393"},{"key":"ref_36","first-page":"599","article-title":"Radiographic Methods for Locating Impacted Maxillary Canines","volume":"63","author":"Dinu","year":"2022","journal-title":"Rom. J. Morphol. Embryol."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"David, A.P., Brad, S., Rusu, L.-C., David, O.T., Samoila, C., and Leretter, M.T. (2024). Automatic Segmentation of the Jaws Used in Guided Insertion of Orthodontic Mini Implants to Improve Their Stability and Precision. Medicina, 60.","DOI":"10.3390\/medicina60101660"},{"key":"ref_38","first-page":"287","article-title":"Accurate Determination for Orthodontic Mini-Implant Placement Using Acrylic Resin Surgical Guide and CBCT","volume":"53","author":"Popa","year":"2016","journal-title":"Mater. Plast."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"190","DOI":"10.37358\/MP.18.2.4992","article-title":"Dimensional Study of Impacted Maxillary Canine Replicas 3D Printed Using Two Types of Resin Materials","volume":"55","author":"Nagib","year":"2018","journal-title":"Mater. Plast."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"4057","DOI":"10.37358\/RC.19.11.7701","article-title":"OPG Fine Preoperative Evaluation of Maxillary Inflammatory and Atrophic Lesions with Postoperative Successfully Surgical Solutions Appreciation of Dentoalveollary Reconstructions Using Heterolog Membranes and Materials Together with Metallic Implants","volume":"70","author":"Sink","year":"2019","journal-title":"Rev. Chim."},{"key":"ref_41","first-page":"217","article-title":"The MRI Fine Evaluation of Cervical Lymphadenopathies and Associated Oral Cavity Pathological Conditions","volume":"117","author":"Rivis","year":"2013","journal-title":"Med. Surg. J."},{"key":"ref_42","first-page":"21","article-title":"Measurement of Proportion of Lower Facial Height and Its Significance in Different Age, Sex and Ethnicity","volume":"14","author":"Maharjan","year":"2014","journal-title":"J. Nepal Dent. Assoc."},{"key":"ref_43","first-page":"11","article-title":"Photometric Facial Analysis\u2014A Baseline Study","volume":"53","author":"Jain","year":"2004","journal-title":"J. Anat. Soc. India"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"125","DOI":"10.5115\/acb.2016.49.2.125","article-title":"Vertical and Horizontal Facial Proportions of Indian American Men","volume":"49","author":"Sadacharan","year":"2016","journal-title":"Anat. Cell Biol."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1825","DOI":"10.1016\/j.bjps.2009.10.032","article-title":"Anthropometric and Aesthetic Analysis of the Indian American Woman\u2019s Face","volume":"63","author":"Husein","year":"2010","journal-title":"J. Plast. Reconstr. Aesthet. Surg."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"125","DOI":"10.4103\/0972-4052.155033","article-title":"Vertical and Horizontal Proportions of the Face and Their Correlation to Phi among Indians in Moradabad Population: A Survey","volume":"15","author":"Anand","year":"2015","journal-title":"J. Indian Prosthodont. Soc."},{"key":"ref_47","unstructured":"Aniwaa (2025, July 09). Shining 3D MetiSmile Scanner, Available online: https:\/\/www.aniwaa.com\/product\/3d-scanners\/shining-3d-dental-metismile."},{"key":"ref_48","unstructured":"Top3DShop (2025, July 09). Shining 3D MetiSmile Face 3D Scanner Review, Available online: https:\/\/top3dshop.com\/product\/shining-3d-metismile-face-3d-scanner."},{"key":"ref_49","unstructured":"Starcona (2025, July 09). MetiSmile AI Software Capabilities for Orthodontics, Available online: https:\/\/starcona.com\/products\/shining3d-metismile-face-scanner."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"1178","DOI":"10.1097\/SCS.0000000000008036","article-title":"Facial anthropometry measurements using three-dimensional stereophotogrammetry analysis among Nigerians","volume":"33","author":"Adekunle","year":"2022","journal-title":"J. Craniofac. Surg."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"e4942","DOI":"10.1097\/GOX.0000000000004942","article-title":"Facial anthropometric norms of the young Black South African woman","volume":"11","author":"Wilson","year":"2023","journal-title":"Plast. Reconstr. Surg. Glob. Open"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1097\/SCS.0000000000008021","article-title":"Photographic nasal soft tissue analysis from preadolescence to young adulthood: Anthropometric measurements","volume":"33","author":"Golpinar","year":"2022","journal-title":"J. Craniofac. Surg."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"346","DOI":"10.2174\/1874210601509010346","article-title":"Photographic facial soft tissue analysis by means of linear and angular measurements in an adolescent Persian population","volume":"9","author":"Moshkelgosha","year":"2015","journal-title":"Open Dent. J."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"17","DOI":"10.4103\/CTD.CTD_4_24","article-title":"Angular photogrammetric analysis for a young adult Garhwali population","volume":"1","author":"Srivastava","year":"2024","journal-title":"Curr. Trends Dent."},{"key":"ref_55","first-page":"2","article-title":"Facial profile characteristics evaluation in a population of Central Romania region","volume":"60","author":"Bucur","year":"2014","journal-title":"Acta Med. Marisiensis"},{"key":"ref_56","doi-asserted-by":"crossref","unstructured":"St\u0103ncioiu, A.-A., Vasica, F., Nagib, R., Popa, A., Motofelea, A.C., Hu\u0219anu, A.A., and Szuhanek, C.-A. (2024). Cephalometric Evaluation of Facial Height Ratios and Growth Patterns: A Retrospective Cohort Study. Appl. Sci., 14.","DOI":"10.20944\/preprints202409.1465.v1"},{"key":"ref_57","doi-asserted-by":"crossref","unstructured":"St\u0103ncioiu, A.-A., Motofelea, A.C., Hu\u0219anu, A.A., Vasica, L., Nagib, R., Popa, A., and Szuhanek, C. (2025). Associations of Digital Measurements: Analysis of Orthopantomography Versus Lateral Cephalograms for Evaluation of Facial Asymmetry. J. Clin. Med., 14.","DOI":"10.20944\/preprints202501.1581.v1"},{"key":"ref_58","doi-asserted-by":"crossref","unstructured":"St\u0103ncioiu, A.-A., Motofelea, A.C., Hu\u0219anu, A.A., Vasica, L., Popa, A., Nagib, R., and Szuhanek, C. (2025). Innovative Aesthetic and Functional Orthodontic Planning with Hard and Soft Tissue Analyses. J. Clin. Med., 14.","DOI":"10.3390\/jcm14134458"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"861","DOI":"10.1007\/s12663-023-01942-3","article-title":"Are Virtually Designed 3D Printed Surgical Splints Accurate Enough for Maxillary Reposition as an Intermediate Orthognathic Surgical Guide?","volume":"22","author":"Sarkarat","year":"2023","journal-title":"J. Maxillofac. Oral Surg."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/21\/7578\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T09:51:02Z","timestamp":1761731462000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/21\/7578"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,25]]},"references-count":59,"journal-issue":{"issue":"21","published-online":{"date-parts":[[2025,11]]}},"alternative-id":["jcm14217578"],"URL":"https:\/\/doi.org\/10.3390\/jcm14217578","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,25]]}}}