{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T19:56:10Z","timestamp":1790193370224,"version":"4.1.0"},"reference-count":37,"publisher":"MDPI AG","issue":"21","license":[{"start":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T00:00:00Z","timestamp":1761782400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"M\u00f6lnlycke Health Care"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Background: The maintenance of an aseptic barrier between the surgical team and patient aids in the prevention of exposure of the patient to pathogens. Variations in gloving practice may have safety implications due to glove failure. An important relationship exists between optimum glove fit and manual dexterity, tactile sensitivity, and fatigue. The aim of this systematic review was to assess the presence and quality of the available literature that investigates the critical association between glove fit and provider performance in the operating theatre and to ascertain whether there is an established standard to determine appropriate glove size. Methods: A systematic review of the literature was undertaken in accordance with the PRISMA statement using one distinct research question regarding glove fit (INPLASY2025100008). Searches on PubMed, Embase, Cochrane Collaboration of Systematic Reviews and Metanalyses and Google Scholar were performed between 1 May 2022 and 24 January 2023. Studies were assessed for eligibility against pre-defined inclusion and exclusion criteria. Risk of bias was determined using multiple assessment tools. Results: This systematic review included 18 studies, nine of which were high-quality Level I or II trials, and multiple observational analyses. Poor glove fit was consistently associated with reduced manual dexterity, impaired tactile sensitivity, and decreased comfort, while oversized or undersized gloves increased the risk of glove perforation and fatigue. These findings underscore the clinical importance of appropriate glove sizing to optimize surgical performance and safety. Conclusions: There is a scarcity of high-quality studies investigating the relationship of glove fit and performance. Furthermore, there does not appear to be a standard method to determine the optimal glove fit for members of the surgical team, nor are there practical examples of how glove size is determined. Further research in this area is required.<\/jats:p>","DOI":"10.3390\/jcm14217695","type":"journal-article","created":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T05:08:47Z","timestamp":1761800927000},"page":"7695","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Hands Deserve Better: A Systematic Review on Surgical Glove Fit and Provider Performance"],"prefix":"10.3390","volume":"14","author":[{"given":"Abhishek","family":"Chatterjee","sequence":"first","affiliation":[{"name":"Department of Surgery, Division of Plastic Surgery, Tufts Medical Center, Boston, MA 02111, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deborah L.","family":"Spratt","sequence":"additional","affiliation":[{"name":"Independent Researcher, Hornell, NY 14843, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9258-487X","authenticated-orcid":false,"given":"Andreas","family":"Enz","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Helios Kliniken Schwerin, Medical School Hamburg, 19055 Schwerin, Germany"},{"name":"Department of Orthopedics, University Medicine Rostock, 18057 Rostock, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jessica","family":"Bah-R\u00f6sman","sequence":"additional","affiliation":[{"name":"Global Medical Affairs, M\u00f6lnlycke Health Care, 43121 M\u00f6lndal, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-5483-8990","authenticated-orcid":false,"given":"C. Tod","family":"Brindle","sequence":"additional","affiliation":[{"name":"Independent Researcher, Norcross, GA 30092, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,10,30]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"159","DOI":"10.26502\/jsr.10020033","article-title":"Burnout Leads to Premature Surgeon Retirement: A Nationwide Survey","volume":"2","author":"Cimbak","year":"2019","journal-title":"J. Surg. Res."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1797","DOI":"10.1007\/s11701-023-01601-2","article-title":"Musculoskeletal Injuries in Cross-Speciality Surgeons: A Survey of UK-Based Doctors","volume":"17","author":"Durden","year":"2023","journal-title":"J. Robot. Surg."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"24","DOI":"10.5704\/MOJ.2003.004","article-title":"Musculoskeletal Occupational Injuries in Orthopaedic Surgeons and Residents","volume":"14","author":"Tan","year":"2020","journal-title":"Malays. Orthop. J."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1429","DOI":"10.1080\/00140139.2012.708058","article-title":"Methodology for Evaluating Gloves in Relation to the Effects on Hand Performance Capabilities: A Literature Review","volume":"55","author":"Dianat","year":"2012","journal-title":"Ergonomics"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1080\/00140139308967930","article-title":"The Effects of Various Thicknesses of Chemical Protective Gloves on Manual Dexterity","volume":"36","author":"Bensel","year":"1993","journal-title":"Ergonomics"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1016\/j.apergo.2006.04.024","article-title":"The Effects of Glove Thickness and Work Load on Female Hand Performance and Fatigue during a Infrequent High-Intensity Gripping Task","volume":"38","author":"Chang","year":"2007","journal-title":"Appl. Ergon."},{"key":"ref_7","first-page":"21","article-title":"Comparative Study: The Effects of Latex and Vinyl Gloves on the Tactile Discrimination of First Year Dental Hygiene Students\u2014Record Details\u2014Embase","volume":"12","author":"Brunick","year":"1990","journal-title":"Clin. Prev. Dent."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1080\/15459620903481660","article-title":"Wearing the Wrong Size Latex Surgical Gloves Impairs Manual Dexterity","volume":"7","author":"Drabek","year":"2010","journal-title":"J. Occup. Environ. Hyg."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Anand, S., Pogoreli\u0107, Z., Singh, A., Llorente Mu\u00f1oz, C.M., Krishnan, N., Dhua, A.K., Goel, P., and Bajpai, M. (2022). Comparison of Unnoticed Glove Perforations during Minimally Invasive versus Open Surgeries: A Systematic Review and Meta-Analysis. Children, 9.","DOI":"10.3390\/children9020179"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Enz, A., Boermeester, M.A., Chatterjee, A., Coombs, N., Dye, L., Johnson, P., Lingaas, E., Mittelmeier, W., Munakata, K., and Sawyer, R.G. (2025, October 27). Protocol for Hands Deserve Better: A Systematic Review of Surgical Gloving Practice. Available online: https:\/\/inplasy.com\/wp-content\/uploads\/2025\/10\/INPLASY-Protocol-8334.pdf.","DOI":"10.37766\/inplasy2025.10.0008"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"n71","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 Statement: An Updated Guideline for Reporting Systematic Reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"key":"ref_12","unstructured":"(2025, October 27). ReD Associates Ethnographic Research Study. Available online: https:\/\/www.redassociates.com\/all-perspectives\/next-wave-of-strategy-juergen-siebenrock-rdwkd."},{"key":"ref_13","unstructured":"Wells, G., Shea, B., O\u2019Connell, D., Peterson, J., Welch, V., Losos, M., and Tugwell, P. (2025, October 27). The Newcastle\u2013Ottawa Scale (NOS) for Assessing the Quality of Non-Randomized Studies in Meta-Analysis. Available online: https:\/\/web.archive.org\/web\/20210716121605id_\/www3.med.unipmn.it\/dispense_ebm\/2009-2010\/Corso%20Perfezionamento%20EBM_Faggiano\/NOS_oxford.pdf."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"d5928","DOI":"10.1136\/bmj.d5928","article-title":"The Cochrane Collaboration\u2019s Tool for Assessing Risk of Bias in Randomised Trials","volume":"343","author":"Higgins","year":"2011","journal-title":"BMJ"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/j.jclinepi.2015.06.005","article-title":"ROBIS: A New Tool to Assess Risk of Bias in Systematic Reviews Was Developed","volume":"69","author":"Whiting","year":"2016","journal-title":"J. Clin. Epidemiol."},{"key":"ref_16","unstructured":"Dearholt, S., and Dang, D. (2012). Johns Hopkins Evidence-Based Practice Model and Guidelines."},{"key":"ref_17","first-page":"133","article-title":"Biomechanics of Surgical Glove Expansion","volume":"4","author":"Aggarwal","year":"1994","journal-title":"J. Long. Term Eff. Med. Implants"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1308\/003588411X12851639108150","article-title":"A Comparison of the Effect of Different Surgical Gloves on Objective Measurement of Fingertip Cutaneous Sensibility","volume":"93","author":"Bucknor","year":"2011","journal-title":"Ann. R. Coll. Surg. Engl."},{"key":"ref_19","first-page":"186","article-title":"Can Surgical Gloves Be Made Thinner without Increasing Their Liability to Puncture?","volume":"78","author":"Carter","year":"1996","journal-title":"Ann. R. Coll. Surg. Engl."},{"key":"ref_20","first-page":"95","article-title":"Glove Failure: An Occupational Hazard of Surgeons in a Developing Country","volume":"42","author":"Gunasekera","year":"1997","journal-title":"J. R. Coll. Surg. Edinb."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1177\/0194599817704377","article-title":"The Effects of Double Gloving on Microsurgical Skills","volume":"157","author":"Hardison","year":"2017","journal-title":"Otolaryngol. Head Neck Surg. Off. J. Am. Acad. Otolaryngol. Head Neck Surg."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1007\/s12630-013-9938-2","article-title":"Factors That Influence the Selection of Sterile Glove Brand: A Randomized Controlled Trial Evaluating the Performance and Cost of Gloves","volume":"60","author":"Johnson","year":"2013","journal-title":"Can. J. Anaesth. J. Can. Anesth."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"e12550","DOI":"10.1016\/j.heliyon.2022.e12550","article-title":"Surgical Experience and Different Glove Wearing Conditions Affect Tactile Sensibility","volume":"8","author":"Man","year":"2022","journal-title":"Heliyon"},{"key":"ref_24","first-page":"20","article-title":"Subjective Effects of Double Gloves on Surgical Performance","volume":"78","author":"Wilson","year":"1996","journal-title":"Ann. R. Coll. Surg. Engl."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1160","DOI":"10.1080\/10803548.2021.1875636","article-title":"Comparison of Surgical Gloves: Perforation, Satisfaction and Manual Dexterity","volume":"28","author":"Basak","year":"2022","journal-title":"Int. J. Occup. Saf. Ergon. JOSE"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1111\/j.1399-6576.2004.00571.x","article-title":"Anaesthetists Should Wear Gloves--Touch Sensitivity Is Improved with a New Type of Thin Glove","volume":"49","author":"Kopka","year":"2005","journal-title":"Acta Anaesthesiol. Scand."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1097\/00006534-199901000-00020","article-title":"Evaluation of Hand Sensibility with Single and Double Latex Gloves","volume":"103","author":"Novak","year":"1999","journal-title":"Plast. Reconstr. Surg."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1235","DOI":"10.14219\/jada.archive.1994.0165","article-title":"Evaluating the Fit of Ambidextrous and Fitted Gloves: Implications for Hand Discomfort","volume":"125","author":"Powell","year":"1994","journal-title":"J. Am. Dent. Assoc. 1939"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"e4354","DOI":"10.1097\/GOX.0000000000004354","article-title":"An Unmet Need: Surgical Gloves with Variable Finger Lengths","volume":"10","author":"Rudolph","year":"2022","journal-title":"Plast. Reconstr. Surg. Glob. Open"},{"key":"ref_30","unstructured":"Stellon, M.A. (2016). The Effect of Surgeon Hand Anthropometry on Surgical Glove Sizing and Implications. [Ph.D. Thesis, University of Connecticut]."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"041004","DOI":"10.1115\/1.4037257","article-title":"Assessing the Importance of Surgeon Hand Anthropometry on the Design of Medical Devices","volume":"11","author":"Stellon","year":"2017","journal-title":"J. Med. Devices"},{"key":"ref_32","first-page":"CD009573","article-title":"Gloves, Extra Gloves or Special Types of Gloves for Preventing Percutaneous Exposure Injuries in Healthcare Personnel","volume":"2014","author":"Mischke","year":"2014","journal-title":"Cochrane Database Syst. Rev."},{"key":"ref_33","first-page":"CD003087","article-title":"Double Gloving to Reduce Surgical Cross-Infection","volume":"2006","author":"Tanner","year":"2006","journal-title":"Cochrane Database Syst. Rev."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1474","DOI":"10.1016\/j.arth.2022.01.001","article-title":"Repetitive Musculoskeletal Injuries: A Survey of Female Adult Reconstruction Surgeons","volume":"37","author":"Varady","year":"2022","journal-title":"J. Arthroplast."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1093\/occmed\/kqz155","article-title":"The Painful Truth: Work-Related Musculoskeletal Disorders in Australian Surgeons","volume":"70","author":"Grant","year":"2020","journal-title":"Occup. Med. Oxf. Engl."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1007\/s00464-003-8824-3","article-title":"The Relationship between Hand Size and Difficulty Using Surgical Instruments: A Survey of 726 Laparoscopic Surgeons","volume":"18","author":"Berguer","year":"2004","journal-title":"Surg. Endosc."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1051","DOI":"10.1007\/s00464-013-3281-0","article-title":"The Ergonomics of Women in Surgery","volume":"28","author":"Sutton","year":"2014","journal-title":"Surg. Endosc."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/21\/7695\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T05:42:31Z","timestamp":1761802951000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/21\/7695"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,30]]},"references-count":37,"journal-issue":{"issue":"21","published-online":{"date-parts":[[2025,11]]}},"alternative-id":["jcm14217695"],"URL":"https:\/\/doi.org\/10.3390\/jcm14217695","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,30]]}}}