{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T04:53:04Z","timestamp":1789015984686,"version":"build-2803163510"},"reference-count":30,"publisher":"MDPI AG","issue":"23","license":[{"start":{"date-parts":[[2025,11,26]],"date-time":"2025-11-26T00:00:00Z","timestamp":1764115200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Objective: This in vitro study aimed to evaluate and compare the trueness and precision of four extraoral 3D facial scanning systems using a standardized 3D-printed human head model. Methods: A 3D-printed head model with 16 anatomical landmarks and 17 inter-landmark linear distances was fabricated using a high-resolution 3D printer. Caliper measurements were used as reference standards. The model was scanned 15 times by four systems: a handheld scanner (MetiSmile, Shining 3D, Hangzhou, China), a desktop scanner (RAYFace v2.0, Ray Co., Seongnam, Gyeonggi-do, Republic of Korea), and two mobile applications (Heges and Polycam, iPhone 15, Apple Inc., Cupertino, CA, USA). All digital distances were measured in Blender software. To assess intra-observer reliability, all measurements were repeated twice by the same examiner with a 3-week interval between sessions, and intra-class correlation coefficients were calculated using a two-way mixed-effects, single-measurement, absolute-agreement model (ICC 3,1). Trueness, defined as the absolute deviation from the reference caliper values, was compared across scanners using the Kruskal\u2013Wallis test due to its non-normal distribution. Precision, regional trueness and precision values across the four scanners defined as the standard deviation of repeated scans, was analyzed using One-way ANOVA with Tukey post-hoc comparisons for normally distributed datasets (\u03b1 = 0.05). Distances were measured digitally in Blender software, and trueness (absolute deviation from reference) and precision (standard deviation of repeated scans) were analyzed using the Kruskal\u2013Wallis test and One-way ANOVA with Tukey post hoc comparisons (\u03b1 = 0.05). Results: The Polycam application demonstrated the highest trueness (0.49 \u00b1 0.32 mm), followed by MetiSmile (0.51 \u00b1 0.36 mm), RAYFace (0.58 \u00b1 0.39 mm), and Heges (0.73 \u00b1 0.42 mm). The MetiSmile scanner showed the highest precision (0.12 \u00b1 0.07 mm), while RAYFace and Polycam exhibited moderate precision (0.28 \u00b1 0.19 mm and 0.15 \u00b1 0.06 mm, respectively). Vertical measurements tended to be more accurate than horizontal ones, and the lower facial region showed smaller deviations; however, these differences were not statistically significant (p &gt; 0.05). Conclusions: MetiSmile achieved the highest precision and Polycam the highest trueness. Although all systems showed mean deviations &lt; 1 mm, only three demonstrated &lt;0.6 mm accuracy (except for Heges scanner). These results suggest that professional and mobile-based scanners can provide clinically acceptable facial data for educational and preliminary digital workflow applications, though further validation under clinical conditions is required. This study provides quantitative evidence on the accuracy and repeatability of commonly available extraoral 3D facial scanning systems under controlled laboratory conditions. The results indicate that both professional-grade and mobile-based scanners can reproduce facial morphology with clinically acceptable deviations, particularly in flat and stable regions such as the forehead and chin. Although only three systems achieved mean trueness below 0.6 mm, all demonstrated errors within 1 mm, sufficient for diagnostic visualization, digital smile design, and preliminary virtual patient modeling. These findings support the safe and cost-effective adoption of extraoral facial scanning in dental education and treatment planning, while emphasizing the need for further validation in real clinical environments where motion, lighting, and soft-tissue variability may affect accuracy.<\/jats:p>","DOI":"10.3390\/jcm14238384","type":"journal-article","created":{"date-parts":[[2025,11,26]],"date-time":"2025-11-26T13:56:34Z","timestamp":1764165394000},"page":"8384","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Evaluation of Trueness and Precision in Extraoral 3D Facial Scanning Systems Using a 3D-Printed Head Model: An In Vitro Study"],"prefix":"10.3390","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-5139-452X","authenticated-orcid":false,"given":"Viet","family":"Hoang","sequence":"first","affiliation":[{"name":"Department of Orthodontics and Pedodontics, Faculty of Dentistry, Van Lang University, Ho Chi Minh City 70000, Vietnam"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-0266-9208","authenticated-orcid":false,"given":"Tue Huu","family":"Nguyen","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Van Lang University, Ho Chi Minh City 70000, Vietnam"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Trang Nhat Uyen","family":"Doan","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Van Lang University, Ho Chi Minh City 70000, Vietnam"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Khue Minh","family":"Vu","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Van Lang University, Ho Chi Minh City 70000, Vietnam"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Khang Chi","family":"Duong","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Van Lang University, Ho Chi Minh City 70000, Vietnam"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"An Sy","family":"Le","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Van Lang University, Ho Chi Minh City 70000, Vietnam"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9598-7543","authenticated-orcid":false,"given":"Lam Hung","family":"Tran","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Faculty of Dentistry, Van Lang University, Ho Chi Minh City 70000, Vietnam"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-8987-227X","authenticated-orcid":false,"given":"Phuc Ngoc","family":"Nguyen","sequence":"additional","affiliation":[{"name":"Department of Periodontology and Implantology, Faculty of Dentistry, Van Lang University, Ho Chi Minh City 70000, Vietnam"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,11,26]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"S21","DOI":"10.1016\/j.jdent.2018.04.019","article-title":"The Digital Patient\u2014Imaging Science in Dentistry","volume":"74","author":"Vandenberghe","year":"2018","journal-title":"J. Dent."},{"key":"ref_2","first-page":"201","article-title":"Face Scan for Ceph 3D: A Green Way for Diagnosis in Children","volume":"23","author":"Beretta","year":"2022","journal-title":"Eur. J. Paediatr. Dent."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"2241","DOI":"10.1097\/SCS.0000000000004485","article-title":"Combining Intraoral Scans, Cone Beam Computed Tomography and Face Scans: The Virtual Patient","volume":"29","author":"Mangano","year":"2018","journal-title":"J. Craniofac. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Joda, T., Zarone, F., and Ferrari, M. (2017). The Complete Digital Workflow in Fixed Prosthodontics: A Systematic Review. BMC Oral Health, 17.","DOI":"10.1186\/s12903-017-0415-0"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.jpor.2019.07.010","article-title":"Accuracy and Practicality of Intraoral Scanner in Dentistry: A Literature Review","volume":"64","author":"Kihara","year":"2020","journal-title":"J. Prosthodont. Res."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/j.jobcr.2021.12.004","article-title":"Effectiveness of Digital Data Acquisition Technologies in the Fabrication of Maxillofacial Prostheses\u2014A Systematic Review","volume":"12","author":"Suresh","year":"2022","journal-title":"J. Oral Biol. Craniofac. Res."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/j.jobcr.2019.07.001","article-title":"Scan Time, Reliability and Accuracy of Craniofacial Measurements Using a 3D Light Scanner","volume":"9","author":"Libdy","year":"2019","journal-title":"J. Oral Biol. Craniofac. Res."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.prosdent.2020.10.015","article-title":"Esthetic Treatment Planning with Digital Animation of the Smile Dynamics: A Technique to Create a 4-Dimensional Virtual Patient","volume":"128","author":"Jreige","year":"2022","journal-title":"J. Prosthet. Dent."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"664","DOI":"10.3390\/prosthesis4040053","article-title":"Facial Scanners in Dentistry: An Overview","volume":"4","author":"Lee","year":"2022","journal-title":"Prosthesis"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Major, M., M\u00e9sz\u00e1ros, B., W\u00fcrsching, T., Poly\u00e1k, M., Kammerhofer, G., N\u00e9meth, Z., Szab\u00f3, G., and Nagy, K. (2024). Evaluation of a Structured Light Scanner for 3d Facial Imaging: A Comparative Study with Direct Anthropometry. Sensors, 24.","DOI":"10.3390\/s24165286"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"20210268","DOI":"10.1259\/dmfr.20210268","article-title":"Integration of Imaging Modalities in Digital Dental Workflows\u2014Possibilities, Limitations, and Potential Future Developments","volume":"50","author":"Shujaat","year":"2021","journal-title":"Dentomaxillofacial Radiol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"358","DOI":"10.2319\/040921-290.1","article-title":"A Comparison between Stereophotogrammetry and Smartphone Structured Light Technology for Three-Dimensional Face Scanning","volume":"92","author":"Farronato","year":"2022","journal-title":"Angle Orthod."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Amornvit, P., and Sanohkan, S. (2019). The Accuracy of Digital Face Scans Obtained from 3D Scanners: An in Vitro Study. Int. J. Environ. Res. Public Health, 16.","DOI":"10.3390\/ijerph16245061"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"105639","DOI":"10.1016\/j.jdent.2025.105639","article-title":"Trueness and Precision of a Handheld, a Desktop and a Mobile 3D Face Scanning System: An in Vitro Study","volume":"155","author":"Nuytens","year":"2025","journal-title":"J. Dent."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1016\/j.jpra.2024.01.014","article-title":"Utility of Smartphone-Based Three-Dimensional Surface Imaging for Digital Facial Anthropometry","volume":"39","author":"Hartmann","year":"2024","journal-title":"JPRAS Open"},{"key":"ref_16","unstructured":"(2025, November 19). MetaHuman Head\u201452 Blendshapes\u2014ARkit Ready (Free). Available online: https:\/\/dragonboots.gumroad.com\/l\/metahumanhead."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"898","DOI":"10.1016\/j.identj.2024.09.007","article-title":"Influence of Head Circumference on the Accuracy of Facial Scanning: An in Vitro Study","volume":"75","author":"Guo","year":"2025","journal-title":"Int. Dent. J."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1186\/s40510-023-00496-x","article-title":"Accuracy of 3D Facial Scans: A Comparison of Three Different Scanning System in an in Vivo Study","volume":"24","author":"Pellitteri","year":"2023","journal-title":"Prog. Orthod."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1016\/j.ajodo.2025.04.009","article-title":"Evaluation of Trueness and Precision of 3 Face-Scanning Devices","volume":"168","author":"Bor","year":"2025","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Tangthaweesuk, N., and Raocharernporn, S. (2025). The Accuracy of Three-Dimensional Facial Scan Obtained from Three Different 3d Scanners. PLoS ONE, 20.","DOI":"10.1371\/journal.pone.0322358"},{"key":"ref_21","first-page":"296","article-title":"An in Vitro Comparison of Accuracy between Three Different Face Scanning Modalities","volume":"31","author":"Michelinakis","year":"2023","journal-title":"Eur. J. Prosthodont. Restor. Dent."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Cho, R.-Y., Byun, S.-H., Yi, S.-M., Ahn, H.-J., Nam, Y.-S., Park, I.-Y., On, S.-W., Kim, J.-C., and Yang, B.-E. (2023). Comparative Analysis of Three Facial Scanners for Creating Digital Twins by Focusing on the Difference in Scanning Method. Bioengineering, 10.","DOI":"10.3390\/bioengineering10050545"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"105553","DOI":"10.1016\/j.jdent.2024.105553","article-title":"Clinical Evaluation of the Accuracy of Two Face Scanners with Different Scanning Technologies","volume":"153","author":"Srinivasan","year":"2025","journal-title":"J. Dent."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Thurzo, A., Strunga, M., Havl\u00ednov\u00e1, R., Reh\u00e1kov\u00e1, K., Urban, R., Surovkov\u00e1, J., and Kurilov\u00e1, V. (2022). Smartphone-Based Facial Scanning as a Viable Tool for Facially Driven Orthodontics?. Sensors, 22.","DOI":"10.20944\/preprints202209.0220.v1"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"321","DOI":"10.2186\/jpr.JPR_D_22_00107","article-title":"Facial Scanning Technologies in the Era of Digital Workflow: A Systematic Review and Network Meta-Analysis","volume":"67","author":"Antonacci","year":"2022","journal-title":"J. Prosthodont. Res."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"381","DOI":"10.4047\/jap.2017.9.5.381","article-title":"Integrating 3D Facial Scanning in a Digital Workflow to CAD\/CAM Design and Fabricate Complete Dentures for Immediate Total Mouth Rehabilitation","volume":"9","author":"Hassan","year":"2017","journal-title":"J. Adv. Prosthodont."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1016\/j.prosdent.2016.07.033","article-title":"A Digital Approach Integrating Facial Scanning in a CAD-CAM Workflow for Complete-Mouth Implant-Supported Rehabilitation of Patients with Edentulism: A Pilot Clinical Study","volume":"117","author":"Hassan","year":"2017","journal-title":"J. Prosthet. Dent."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"rjae483","DOI":"10.1093\/jscr\/rjae483","article-title":"A Multidisciplinary Approach to Managing Severe Gummy Smile Using 3D Simulation and Digital Surgical Guide: A Case Report","volume":"2024","author":"Viet","year":"2024","journal-title":"J. Surg. Case Rep."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1563\/aaid-joi-D-24-00083","article-title":"Full-Arch Implant-Supported Rehabilitation Using Reverse Scan Technique: A Case Report","volume":"51","author":"Nguyen","year":"2025","journal-title":"J. Oral Implantol."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"e19612","DOI":"10.7717\/peerj.19612","article-title":"Comparative Analysis of Lingual Bracket Transfer Accuracy Using Fully versus Partially Enclosed 3D-Printed Indirect Bonding Trays: An In Vivo Study","volume":"13","author":"Nguyen","year":"2025","journal-title":"PeerJ"}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/23\/8384\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,26]],"date-time":"2025-11-26T14:07:13Z","timestamp":1764166033000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/14\/23\/8384"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,26]]},"references-count":30,"journal-issue":{"issue":"23","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["jcm14238384"],"URL":"https:\/\/doi.org\/10.3390\/jcm14238384","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,26]]}}}