{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,8]],"date-time":"2026-03-08T14:17:40Z","timestamp":1772979460190,"version":"3.50.1"},"reference-count":35,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T00:00:00Z","timestamp":1772755200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Zimmer Biomet"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Background\/Objectives: Rigid interfragmentary compression is essential for primary bone healing following fractures, osteotomies, and arthrodeses of the foot and ankle. Evidence on the clinical performance of the MAX Variable Pitch Compression (VPC) Screw System (Zimmer Biomet, Warsaw, IN, USA) remains limited. This post-market, retrospective cohort study evaluated its safety, performance, and patient-reported outcomes. Methods: A single-center, consecutive series of patients treated with the MAX VPC Screw System for foot or ankle fractures, osteotomies, or arthrodeses between March 2018 and October 2023 was analyzed. The primary endpoint was radiographic and clinical bone union or joint fusion at 6\u20138 weeks and \u226518 months. Secondary endpoints included adverse events and functional outcomes using the Foot and Ankle Ability Measure (FAAM). Results: A total of 214 procedures were included (27 fractures, 80 osteotomies, 107 arthrodeses). Union was assessed in 209 procedures (97.7%) at 6\u20138 weeks and in 82 procedures (38.3%) at \u226518 months. Union rates were 86.1% at 6\u20138 weeks and 98.8% at \u226518 months. Early union was higher in arthrodeses (91.5%) than in fractures\/osteotomies (80.6%). Adverse events occurred in 13.1% of procedures, 67.9% of which were device-related; no recurrent mechanical failures were observed. Mean FAAM scores were 92.3 (ADL) and 78.8 (Sports) for arthrodeses and 94.3 and 85.8, respectively, for fractures\/osteotomies, at a mean FAAM follow-up of 2.9 years. Conclusions: The MAX VPC Screw System demonstrated high bone-union rates, favorable functional outcomes, and a moderate number of device-related complications. These results support its clinical use in foot and ankle surgery. However, the retrospective, single-center design limits generalizability, and prospective multicenter trials are warranted to confirm these findings.<\/jats:p>","DOI":"10.3390\/jcm15052024","type":"journal-article","created":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T11:05:44Z","timestamp":1772795144000},"page":"2024","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Post-Market Clinical Follow-Up of the MAX Variable Pitch Compression Screw System in Foot and Ankle Surgery: Safety, Performance, and Patient-Reported Outcomes"],"prefix":"10.3390","volume":"15","author":[{"given":"Thomas J. J.","family":"Wolfinger","sequence":"first","affiliation":[{"name":"Department of Traumatology, Orthopaedics and Hand Surgery, Fricktal Health Center AG, 4310 Rheinfelden, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S\u00e9verin R.","family":"Wendelspiess","sequence":"additional","affiliation":[{"name":"Department of Traumatology, Orthopaedics and Hand Surgery, Fricktal Health Center AG, 4310 Rheinfelden, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dirk F.","family":"Th\u00fcmmler","sequence":"additional","affiliation":[{"name":"Department of Traumatology, Orthopaedics and Hand Surgery, Fricktal Health Center AG, 4310 Rheinfelden, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Urs N.","family":"Genewein","sequence":"additional","affiliation":[{"name":"Department of Traumatology, Orthopaedics and Hand Surgery, Fricktal Health Center AG, 4310 Rheinfelden, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2026,3,6]]},"reference":[{"key":"ref_1","first-page":"e76250","article-title":"Principles of Fracture Healing and Fixation: A Literature Review","volume":"16","author":"Beeharry","year":"2024","journal-title":"Cureus"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1055\/s-0041-1732334","article-title":"Bone Healing and Inflammation: Principles of Fracture and Repair","volume":"35","author":"ElHawary","year":"2021","journal-title":"Semin. Plast. Surg."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1038\/nrrheum.2014.164","article-title":"Fracture Healing: Mechanisms and Interventions","volume":"11","author":"Einhorn","year":"2015","journal-title":"Nat. Rev. Rheumatol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1099","DOI":"10.1016\/S0736-0266(02)00044-X","article-title":"The Effect of Mechanical Stability on Local Vascularization and Tissue Differentiation in Callus Healing","volume":"20","author":"Claes","year":"2002","journal-title":"J. Orthop. Res."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"S3","DOI":"10.1016\/j.injury.2014.04.002","article-title":"Delayed Union and Nonunions: Epidemiology, Clinical Issues, and Financial Aspects","volume":"45","author":"Hak","year":"2014","journal-title":"Injury"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"111845","DOI":"10.1016\/j.injury.2024.111845","article-title":"Effect of Mechanical Stability of Osteosynthesis on Infection Rates: Timing of Temporary and Definitive Fixation","volume":"55","author":"Santolini","year":"2024","journal-title":"Injury"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Bowers, K.M., and Anderson, D.E. (2024). Delayed Union and Nonunion: Current Concepts, Prevention, and Correction: A Review. Bioengineering, 11.","DOI":"10.3390\/bioengineering11060525"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"S64","DOI":"10.1016\/j.injury.2017.04.019","article-title":"Technical Considerations to Avoid Delayed and Non-Union","volume":"48","author":"McMillan","year":"2017","journal-title":"Injury"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1031","DOI":"10.1007\/s00264-010-1129-y","article-title":"Comparison of Headless Screws Used in the Treatment of Proximal Nonunion of Scaphoid Bone","volume":"35","author":"Gereli","year":"2011","journal-title":"Int. Orthop."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1016\/j.hcl.2010.04.005","article-title":"Headless Compression Screw Fixation of Scaphoid Fractures","volume":"26","author":"Fowler","year":"2010","journal-title":"Hand Clinics"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1007\/s43465-020-00107-5","article-title":"Which Headless Compression Screw Produces the Highest Interfragmentary Compression Force in Scaphoid Fracture?","volume":"54","author":"Vishwanathan","year":"2020","journal-title":"Indian J. Orthop."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Gruszka, D., Herr, R., Hely, H., Hofmann, P., Klitscher, D., Hofmann, A., and Rommens, P.M. (2016). Impact of Different Screw Designs on Durability of Fracture Fixation: In Vitro Study with Cyclic Loading of Scaphoid Bones. PLoS ONE, 11.","DOI":"10.1371\/journal.pone.0145949"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1177\/1558944719877890","article-title":"A Mechanical Comparison of the Compressive Force Generated by Various Headless Compression Screws and the Impact of Fracture Gap Size","volume":"16","author":"Ilyas","year":"2021","journal-title":"Hand"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1728","DOI":"10.1016\/j.jhsa.2013.04.027","article-title":"Insertion Profiles of 4 Headless Compression Screws","volume":"38","author":"Hart","year":"2013","journal-title":"J. Hand Surg."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"385.e1","DOI":"10.1016\/j.jhsa.2017.10.018","article-title":"Fracture Gap Reduction with Variable-Pitch Headless Screws","volume":"43","author":"Roebke","year":"2018","journal-title":"J. Hand Surg."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.1016\/j.jhsa.2012.03.018","article-title":"The Durability of the Intrascaphoid Compression of Headless Compression Screws: In Vitro Study","volume":"37","author":"Gruszka","year":"2012","journal-title":"J. Hand Surg."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/j.injury.2011.07.011","article-title":"A Biomechanical Study on Variation of Compressive Force along the Acutrak 2 Screw","volume":"43","author":"Sugathan","year":"2012","journal-title":"Injury"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1159","DOI":"10.1016\/j.injury.2012.03.015","article-title":"Biomechanical Analysis of Second-Generation Headless Compression Screws","volume":"43","author":"Assari","year":"2012","journal-title":"Injury"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1601","DOI":"10.1007\/s00402-009-0971-0","article-title":"A Biomechanical Study on Preloaded Compression Effect on Headless Screws","volume":"129","author":"Baran","year":"2009","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1016\/j.promfg.2020.03.070","article-title":"Torque Control During Bone Insertion of Cortical Screws","volume":"46","author":"Moldovan","year":"2020","journal-title":"Procedia Manuf."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.clinbiomech.2019.12.004","article-title":"Screw Insertion Torque as Parameter to Judge the Fixation. Assessment of Torque and Pull-out Strength in Different Bone Densities and Screw-Pitches","volume":"72","author":"Addevico","year":"2020","journal-title":"Clin. Biomech."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1186\/s13018-023-04040-9","article-title":"Factors Influencing Successful Bone Union of Isolated Subtalar Arthrodesis for Posttraumatic Subtalar Arthritis: A Multicenter Case Series","volume":"18","author":"Kim","year":"2023","journal-title":"J. Orthop. Surg. Res."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1016\/j.fas.2020.12.011","article-title":"Open Ankle Arthrodesis: A Systematic Review of Approaches and Fixation Methods","volume":"27","author":"Doorgakant","year":"2021","journal-title":"Foot Ankle Surg."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1186\/s13018-025-05529-1","article-title":"Comparative Study of Cannulated Compression Headless Screws and Anatomical Locking Compression Hook Plates for Fracture of Fifth Metatarsal Base in Athletes and Young Adults","volume":"20","author":"Cao","year":"2025","journal-title":"J. Orthop. Surg. Res."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"5242806","DOI":"10.1155\/2018\/5242806","article-title":"Comparison of Bioabsorbable Magnesium versus Titanium Screw Fixation for Modified Distal Chevron Osteotomy in Hallux Valgus","volume":"2018","author":"Acar","year":"2018","journal-title":"Biomed. Res. Int."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"350","DOI":"10.55095\/achot2020\/053","article-title":"Comparison of Clinical and Radiological Results of Two Fixation Materials after Distal Chevron Osteotomy for Hallux Valgus?\u2014Two Kirschner Wires versus Single Screw Fixation","volume":"87","author":"Bilgin","year":"2020","journal-title":"Acta Chir. Orthop. Traumatol. Cech."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1177\/10711007231171087","article-title":"CT-Verified Union Rate Following Arthrodesis of Ankle, Hindfoot, or Midfoot: A Systematic Review","volume":"44","author":"Leslie","year":"2023","journal-title":"Foot Ankle Int."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"World Medical Association (2013). World Medical Association Declaration of Helsinki: Ethical Principles for Medical Research Involving Human Subjects. JAMA, 310, 2191\u20132194.","DOI":"10.1001\/jama.2013.281053"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"968","DOI":"10.1177\/107110070502601113","article-title":"Evidence of Validity for the Foot and Ankle Ability Measure (FAAM)","volume":"26","author":"Martin","year":"2005","journal-title":"Foot Ankle Int."},{"key":"ref_30","unstructured":"R Core Team (2023). R: A Language and Environment for Statistical Computing, R Foundation for Statistical Computing."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1186\/s13047-022-00540-9","article-title":"First Metatarsophalangeal Joint Arthrodesis\/Fusion: A Systematic Review of Modern Fixation Techniques","volume":"15","author":"Kang","year":"2022","journal-title":"J. Foot Ankle Res."},{"key":"ref_32","first-page":"211","article-title":"Percutaneous Foot Surgery without Osteosynthesis in Hallux Valgus and Outcomes","volume":"9","author":"Restuccia","year":"2021","journal-title":"Arch. Bone Jt. Surg."},{"key":"ref_33","first-page":"1395","article-title":"Lateral Open Wedge Calcaneus Osteotomy with Bony Allograft Augmentation in Adult Acquired Flatfoot Deformity","volume":"31","author":"Mazzola","year":"2021","journal-title":"Clinical and Radiological Results. Eur. J. Orthop. Surg. Traumatol."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"4861","DOI":"10.1007\/s00402-023-04813-1","article-title":"Irritation from Metalwork After Ankle Arthrodesis Fixed Using Screws: A Proportional Meta-Analysis and Systematic Review","volume":"143","author":"Izzo","year":"2023","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"2473011418S00011","DOI":"10.1177\/2473011418S00011","article-title":"Normative Values for Commonly Reported Outcome Measures in the Foot and Ankle","volume":"3","author":"Matheny","year":"2018","journal-title":"Foot Ankle Orthop."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/15\/5\/2024\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,8]],"date-time":"2026-03-08T05:29:37Z","timestamp":1772947777000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/15\/5\/2024"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,6]]},"references-count":35,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2026,3]]}},"alternative-id":["jcm15052024"],"URL":"https:\/\/doi.org\/10.3390\/jcm15052024","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,6]]}}}