{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T12:51:34Z","timestamp":1777899094061,"version":"3.51.4"},"reference-count":27,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Background\/Objectives: Valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) is an established treatment for failed surgical aortic bioprostheses, but dedicated data on the MyVal platform remain limited. We evaluated outcomes, hemodynamics, residual gradient, and an exploratory matched comparison with ACURATE neo2. Methods: This prospective, single-center cohort included consecutive patients with failed surgical aortic bioprostheses treated with MyVal ViV-TAVI between July 2022 and June 2025. Outcomes were reported according to VARC-3. Results: Sixty-eight patients were included (age 77 \u00b1 7 years; 51.5% women; EuroSCORE II 7.3 \u00b1 1.8%). Technical success was 100%, with no 30-day death, stroke, myocardial infarction, second-valve implantation, or emergency surgical conversion. Mean gradient decreased from 38.0 \u00b1 9.5 mmHg at baseline to 6.7 \u00b1 2.1 mmHg post-procedure and remained low at 1 year (8.1 \u00b1 2.5 mmHg; overall p &lt; 0.001). AVA increased from 0.80 \u00b1 0.23 cm2 to 1.98 \u00b1 0.19 cm2 post-procedure and was 1.86 \u00b1 0.23 cm2 at 1 year (overall p &lt; 0.001). Smaller true internal diameter independently predicted elevated 1-year gradient (adjusted OR per 1-mm decrease 1.33, 95% CI 1.04\u20131.78; p = 0.028). In the exploratory matched comparison, safety and hemodynamic outcomes did not differ significantly between MyVal and ACURATE neo2. At a median follow-up of 12.8 months, all-cause mortality and heart failure hospitalization were each 4.4%. Conclusions: In this prospective single-center cohort, MyVal ViV-TAVI was associated with high procedural success and favorable 1-year hemodynamic outcomes, with residual gradient driven mainly by small surgical valve true internal diameter.<\/jats:p>","DOI":"10.3390\/jcm15093462","type":"journal-article","created":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T09:33:17Z","timestamp":1777627997000},"page":"3462","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Transfemoral Valve-in-Valve TAVI with MyVal for Failed Surgical Aortic Bioprostheses: Procedural Outcomes, Serial Hemodynamics, and Anatomy-Based Determinants of Residual Gradient"],"prefix":"10.3390","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7155-9907","authenticated-orcid":false,"given":"Georgios E.","family":"Papadopoulos","sequence":"first","affiliation":[{"name":"Cardiology Department, Interbalkan Medical Center, 57001 Thessaloniki, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4444-3781","authenticated-orcid":false,"given":"Ilias","family":"Ninios","sequence":"additional","affiliation":[{"name":"Cardiology Department, Interbalkan Medical Center, 57001 Thessaloniki, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3080-5729","authenticated-orcid":false,"given":"Sotirios","family":"Evangelou","sequence":"additional","affiliation":[{"name":"Cardiology Department, Interbalkan Medical Center, 57001 Thessaloniki, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Ioannides","sequence":"additional","affiliation":[{"name":"Cardiology Department, Interbalkan Medical Center, 57001 Thessaloniki, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Athinodoros","family":"Nikitopoulos","sequence":"additional","affiliation":[{"name":"Cardiology Department, Interbalkan Medical Center, 57001 Thessaloniki, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0390-7172","authenticated-orcid":false,"given":"Vlasis","family":"Ninios","sequence":"additional","affiliation":[{"name":"Cardiology Department, Interbalkan Medical Center, 57001 Thessaloniki, Greece"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2026,5,1]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2335","DOI":"10.1161\/CIRCULATIONAHA.112.104505","article-title":"Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: Results from the global valve-in-valve registry","volume":"126","author":"Dvir","year":"2012","journal-title":"Circulation"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1016\/j.jcin.2022.02.014","article-title":"5-Year Follow-Up From the PARTNER 2 Aortic Valve-in-Valve Registry for Degenerated Aortic Surgical Bioprostheses","volume":"15","author":"Hahn","year":"2022","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"4635","DOI":"10.1093\/eurheartj\/ehaf194","article-title":"2025 ESC\/EACTS Guidelines for the management of valvular heart disease","volume":"46","author":"Praz","year":"2025","journal-title":"Eur. Heart J."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1016\/j.jacc.2018.04.074","article-title":"Transcatheter Aortic Valve Replacement of Failed Surgically Implanted Bioprostheses","volume":"72","author":"Tuzcu","year":"2018","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"2731","DOI":"10.1093\/eurheartj\/ehaa544","article-title":"Long-term outcomes after transcatheter aortic valve implantation in failed bioprosthetic valves","volume":"41","author":"Bleiziffer","year":"2020","journal-title":"Eur. Heart J."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1001\/jama.2014.7246","article-title":"Transcatheter aortic valve implantation in failed bioprosthetic surgical valves","volume":"312","author":"Dvir","year":"2014","journal-title":"JAMA"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1016\/j.jcin.2017.08.039","article-title":"Impact of Pre-Existing Prosthesis-Patient Mismatch on Survival Following Aortic Valve-in-Valve Procedures","volume":"11","author":"Pibarot","year":"2018","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"e013558","DOI":"10.1161\/CIRCINTERVENTIONS.123.013558","article-title":"Impact of Elevated Gradients After Transcatheter Aortic Valve Implantation for Degenerated Surgical Aortic Valve Bioprostheses","volume":"17","author":"Kherallah","year":"2024","journal-title":"Circ. Cardiovasc. Interv."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"e757","DOI":"10.4244\/EIJ-D-20-00067","article-title":"Risk of coronary obstruction and the need to perform BASILICA: The VIVID classification","volume":"16","author":"Tang","year":"2020","journal-title":"EuroIntervention"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.jcct.2023.01.042","article-title":"Valve-in-valve TAVI and risk of coronary obstruction: Validation of the VIVID classification","volume":"17","author":"Tomii","year":"2023","journal-title":"J. Cardiovasc. Comput. Tomogr."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"e011045","DOI":"10.1161\/CIRCINTERVENTIONS.121.011045","article-title":"Coronary Access After Transcatheter Aortic Valve Replacement With Commissural Alignment: The ALIGN-ACCESS Study","volume":"15","author":"Tarantini","year":"2022","journal-title":"Circ. Cardiovasc. Interv."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1016\/j.jcin.2022.12.019","article-title":"Outcomes of Bioprosthetic Valve Fracture in Patients Undergoing Valve-in-Valve TAVR","volume":"16","author":"Chhatriwalla","year":"2023","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"e005216","DOI":"10.1161\/CIRCINTERVENTIONS.117.005216","article-title":"Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement","volume":"10","author":"Chhatriwalla","year":"2017","journal-title":"Circ. Cardiovasc. Interv."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.ijcard.2021.06.029","article-title":"Operator preference and determinants of size selection when additional intermediate-size aortic transcatheter heart valves are made available","volume":"338","author":"Kawashima","year":"2021","journal-title":"Int. J. Cardiol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"e12","DOI":"10.15420\/icr.2020.32","article-title":"Myval: A Novel Transcatheter Heart Valve for the Treatment of Severe Aortic Stenosis","volume":"18","author":"Seth","year":"2023","journal-title":"Interv. Cardiol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2695","DOI":"10.1016\/S0140-6736(24)00821-3","article-title":"LANDMARK comparison of early outcomes of newer-generation Myval transcatheter heart valve series with contemporary valves (Sapien and Evolut) in real-world individuals with severe symptomatic native aortic stenosis: A randomised non-inferiority trial","volume":"403","author":"Baumbach","year":"2024","journal-title":"Lancet"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1362","DOI":"10.1016\/S0140-6736(25)00106-0","article-title":"SAPIEN 3 versus Myval transcatheter heart valves for transcatheter aortic valve implantation (COMPARE-TAVI 1): A multicentre, randomised, non-inferiority trial","volume":"405","author":"Terkelsen","year":"2025","journal-title":"Lancet"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1016\/j.carrev.2020.11.018","article-title":"Transcatheter Valve-in-Valve Implantation With a Novel Balloon-Expandable Device in Patients with Bioprosthetic Heart Valve Failure: A Case Series","volume":"28","author":"Ielasi","year":"2021","journal-title":"Cardiovasc. Revasc. Med."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/j.ijcard.2023.01.017","article-title":"Transcatheter valve-in-valve or valve-in-ring implantation with a novel balloon-expandable device in patients with bioprosthetic left side heart valves failure: 1-year follow-up from a multicenter experience","volume":"376","author":"Moscarella","year":"2023","journal-title":"Int. J. Cardiol."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"VARC-3 Writing Committee, G\u00e9n\u00e9reux, P., Piazza, N., Alu, M.C., Nazif, T., Hahn, R.T., Pibarot, P., Bax, J.J., Leipsic, J.A., and Blanke, P. (2021). Valve Academic Research Consortium 3: Updated endpoint definitions for aortic valve clinical research. Eur. Heart J., 42, 1825\u20131857.","DOI":"10.1093\/eurheartj\/ehaa799"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2999","DOI":"10.1016\/j.jcin.2023.10.028","article-title":"Balloon- vs Self-Expanding Transcatheter Valves for Failed Small Surgical Aortic Bioprostheses: 1-Year Results of the LYTEN Trial","volume":"16","author":"Nuche","year":"2023","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"2655","DOI":"10.1253\/circj.CJ-18-0157","article-title":"Outcomes of Self-Expanding vs. Balloon-Expandable Transcatheter Heart Valves for the Treatment of Degenerated Aortic Surgical Bioprostheses\u2014A Propensity Score-Matched Comparison","volume":"82","author":"Ochiai","year":"2018","journal-title":"Circ. J."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1016\/j.jacc.2022.05.005","article-title":"Balloon- vs Self-Expanding Valve Systems for Failed Small Surgical Aortic Valve Bioprostheses","volume":"80","author":"Serra","year":"2022","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Papadopoulos, G.E., Ninios, I., Evangelou, S., Ioannidis, A., Nikitopoulos, A., Giannakoulas, G., and Ninios, V. (2025). Efficacy and Safety of ACURATE neo2 in Valve-in-Valve TAVI: A Prospective Single-Center Study. J. Clin. Med., 14.","DOI":"10.20944\/preprints202505.2091.v1"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1240","DOI":"10.1016\/j.jcin.2019.03.035","article-title":"The BASILICA Trial: Prospective Multicenter Investigation of Intentional Leaflet Laceration to Prevent TAVR Coronary Obstruction","volume":"12","author":"Khan","year":"2019","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.1007\/s10554-015-0724-9","article-title":"Exercise stress echocardiography with tissue Doppler imaging in risk stratification of mild to moderate aortic stenosis","volume":"31","author":"Sonaglioni","year":"2015","journal-title":"Int. J. Cardiovasc. Imaging"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1007\/s12574-024-00664-w","article-title":"The value of the dynamic changes in cardiac power output in aortic stenosis patients following transcatheter aortic valve implantation: An exercise stress echocardiography study","volume":"23","author":"Miyahara","year":"2025","journal-title":"J. Echocardiogr."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/15\/9\/3462\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T09:50:28Z","timestamp":1777629028000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/15\/9\/3462"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,1]]},"references-count":27,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2026,5]]}},"alternative-id":["jcm15093462"],"URL":"https:\/\/doi.org\/10.3390\/jcm15093462","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,1]]}}}