{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T02:52:58Z","timestamp":1777949578196,"version":"3.51.4"},"reference-count":28,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T00:00:00Z","timestamp":1777680000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Background: Percutaneous liver biopsy is a cornerstone in the diagnostic and therapeutic management of pediatric liver diseases. However, data on the optimal needle gauge for coaxial techniques in children remain scarce. Smaller-gauge needles may theoretically enhance safety but could potentially compromise diagnostic yield. Objectives: The primary objective of this study was to evaluate and compare the safety and diagnostic clinical adequacy of ultrasound-guided percutaneous liver biopsies performed with semi-automated 20G versus 18G coaxial needles in pediatric patients. Patients and Methods: This retrospective cohort study included consecutive patients aged \u226419 years who underwent percutaneous non-targeted liver biopsies at a tertiary medical center between 2006 and 2012. Patient demographics, biopsy technique parameters (including needle gauge, number of cores, and tract embolization), and procedure-related complications were analyzed. Procedural success was defined by diagnostic and clinical adequacy, requiring a definitive pathology report and the presence of \u22657 portal tracts (the widely accepted threshold for a reliable histologic diagnosis). Complications were classified according to the Society of Interventional Radiology guidelines. Results: A total of 320 biopsies were performed in 260 patients (44.6% female; mean age 7.4 \u00b1 6.0 years). Common indications included post-liver transplantation surveillance (28.4%) and unexplained liver enzyme elevation (22.5%). Biopsies were performed using 18G (n = 148; 46.3%) or 20G (n = 172; 53.7%) coaxial needles. Diagnostic and clinical adequacy was achieved in 100% of the procedures, with biopsy results directly influencing clinical management in 39.7% of cases. The overall complication rate was 5.3% (3.4% minor, 1.9% major), with no procedure-related mortality. While raw complication rates were numerically higher in the 20G group (likely to reflect an operator-driven selection bias for younger or higher-risk patients), the differences between the 18G and 20G needles were not statistically significant. Notably, the use of the 20G needle was associated with a significantly reduced clinical need for post-biopsy tract embolization. Conclusions: Our findings demonstrate no statistically significant differences in complication rates or diagnostic clinical adequacy between 18G and 20G coaxial needles for pediatric percutaneous liver biopsies. When selected based on appropriate clinical judgment, the 20G needle provides a high diagnostic yield and serves as an effective option, particularly for reducing the need for tract embolization. However, both 18G and 20G needles represent acceptable clinical options within the pediatric interventional armamentarium. Ultimately, the choice of needle gauge should be meticulously tailored to individual patient characteristics, bleeding risk profiles, and specific clinical indications, rather than uniformly recommending a smaller gauge across all pediatric age groups.<\/jats:p>","DOI":"10.3390\/jcm15093497","type":"journal-article","created":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T01:12:09Z","timestamp":1777857129000},"page":"3497","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Safety and Efficacy Performance of Coaxial 18G vs. 20G Needles for Pediatric Percutaneous Liver Biopsy: A Retrospective Cohort Study"],"prefix":"10.3390","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9062-7354","authenticated-orcid":false,"given":"Gil N.","family":"Bachar","sequence":"first","affiliation":[{"name":"Units of Vascular and Interventional Radiology, Department of Diagnostic Radiology, Rabin Medical Center, Hasharon and Beilinson Hospitals, Petach Tikva 49100, Israel"},{"name":"Gray\u2019s Faculty of Medicine, Tel Aviv University, Tel Aviv 6139001, Israel"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shlomit","family":"Tamir","sequence":"additional","affiliation":[{"name":"Units of Vascular and Interventional Radiology, Department of Diagnostic Radiology, Rabin Medical Center, Hasharon and Beilinson Hospitals, Petach Tikva 49100, Israel"},{"name":"Gray\u2019s Faculty of Medicine, Tel Aviv University, Tel Aviv 6139001, Israel"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aeonv","family":"Choen","sequence":"additional","affiliation":[{"name":"Units of Vascular and Interventional Radiology, Department of Diagnostic Radiology, Rabin Medical Center, Hasharon and Beilinson Hospitals, Petach Tikva 49100, Israel"},{"name":"Gray\u2019s Faculty of Medicine, Tel Aviv University, Tel Aviv 6139001, Israel"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yael","family":"Rapson","sequence":"additional","affiliation":[{"name":"Units of Vascular and Interventional Radiology, Department of Diagnostic Radiology, Rabin Medical Center, Hasharon and Beilinson Hospitals, Petach Tikva 49100, Israel"},{"name":"Gray\u2019s Faculty of Medicine, Tel Aviv University, Tel Aviv 6139001, Israel"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8930-6932","authenticated-orcid":false,"given":"Ahuva","family":"Grubstein","sequence":"additional","affiliation":[{"name":"Units of Vascular and Interventional Radiology, Department of Diagnostic Radiology, Rabin Medical Center, Hasharon and Beilinson Hospitals, Petach Tikva 49100, Israel"},{"name":"Gray\u2019s Faculty of Medicine, Tel Aviv University, Tel Aviv 6139001, Israel"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8574-2235","authenticated-orcid":false,"given":"Eli","family":"Atar","sequence":"additional","affiliation":[{"name":"Units of Vascular and Interventional Radiology, Department of Diagnostic Radiology, Rabin Medical Center, Hasharon and Beilinson Hospitals, Petach Tikva 49100, Israel"},{"name":"Gray\u2019s Faculty of Medicine, Tel Aviv University, Tel Aviv 6139001, Israel"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2026,5,2]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1007\/s00247-009-1311-9","article-title":"Is juvenile liver biopsy unsafe? Putting an end to a common misapprehension","volume":"39","author":"Pietrobattista","year":"2009","journal-title":"Pediatr. Radiol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1007\/s002470000244","article-title":"Liver biopsy methods for pediatric oncology patients","volume":"30","author":"Hoffer","year":"2000","journal-title":"Pediatr. Radiol."},{"key":"ref_3","first-page":"536","article-title":"Percutaneous liver biopsy in children: Impact of ultrasonography and spring-loaded biopsy needles","volume":"31","author":"Scheimann","year":"2000","journal-title":"J. Pediatr. Gastroenterol. Nutr."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"W644","DOI":"10.2214\/AJR.05.1536","article-title":"Sonographically guided percutaneous liver biopsy in infants: A retrospective review","volume":"187","author":"Amaral","year":"2006","journal-title":"AJR Am. J. Roentgenol."},{"key":"ref_5","first-page":"213","article-title":"Outpatient liver biopsy in children: A medical position statement of the North American Society for Pediatric Gastroenterology and Nutrition","volume":"23","author":"Fox","year":"1996","journal-title":"J. Pediatr. Gastroenterol. Nutr."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1007\/s00247-003-1044-0","article-title":"Blind and ultrasound-guided percutaneous liver biopsy in children","volume":"33","author":"Nobili","year":"2003","journal-title":"Pediatr. Radiol."},{"key":"ref_7","first-page":"364","article-title":"The utility of ultrasound site selection for pediatric percutaneous liver biopsy","volume":"36","author":"Kader","year":"2003","journal-title":"J. Pediatr. Gastroenterol. Nutr."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.1002\/hep.510230522","article-title":"The role of sonography and automatic-needle biopsy in outpatient percutaneous liver biopsy","volume":"23","author":"Lindor","year":"1996","journal-title":"Hepatology"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"413","DOI":"10.2214\/AJR.07.2676","article-title":"Percutaneous imaging-guided solid organ core needle biopsy: Coaxial versus noncoaxial method","volume":"190","author":"Hatfield","year":"2008","journal-title":"AJR Am. J. Roentgenol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1097\/MPG.0b013e3181e7e832","article-title":"Value of ultrasound-guided percutaneous liver biopsy in children following liver transplantation","volume":"51","author":"Sornsakrin","year":"2010","journal-title":"J. Pediatr. Gastroenterol. Nutr."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1016\/0016-5085(92)90112-C","article-title":"Complications of percutaneous liver biopsy in children","volume":"102","author":"Cohen","year":"1992","journal-title":"Gastroenterology"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1002\/cncr.21193","article-title":"Percutaneous biopsy of pediatric solid tumors","volume":"104","author":"Garrett","year":"2005","journal-title":"Cancer"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1007\/BF02079063","article-title":"Complications of percutaneous liver biopsy in infants and children","volume":"154","author":"Lachaux","year":"1995","journal-title":"Eur. J. Pediatr."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1097\/01.mpg.0000184608.22928.f9","article-title":"Safety of percutaneous liver biopsy in infants less than three months old","volume":"41","author":"Azzam","year":"2005","journal-title":"J. Pediatr. Gastroenterol. Nutr."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1007\/s00270-023-03631-7","article-title":"Quick, Safe, Effective: Ultrasound-Guided Percutaneous Liver Biopsy in the Pediatric Patient","volume":"47","author":"Salamo","year":"2024","journal-title":"Cardiovasc. Interv. Radiol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1097\/MPG.0000000000001601","article-title":"Ultrasound-guided Liver Biopsies in Children: A Single-center Experience and Risk Factors for Minor Bleeding","volume":"65","author":"Bilreiro","year":"2017","journal-title":"J. Pediatr. Gastroenterol. Nutr."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1097\/MPG.0000000000001565","article-title":"Outpatient Liver Biopsy in Children: Safety, Feasibility, and Economic Impact","volume":"65","author":"Bolia","year":"2017","journal-title":"J. Pediatr. Gastroenterol. Nutr."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1355","DOI":"10.1002\/jum.15229","article-title":"Complications After Percutaneous Ultrasound-Guided Liver Biopsy: A Systematic Review and Meta-analysis of a Population of More Than 12,000 Patients From 51 Cohort Studies","volume":"39","author":"Tian","year":"2020","journal-title":"J. Ultrasound Med."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1840","DOI":"10.1016\/j.jvir.2020.07.012","article-title":"Society of Interventional Radiology Quality Improvement Standards on Percutaneous Needle Biopsy in Adult and Pediatric Patients","volume":"31","author":"Sheth","year":"2020","journal-title":"J. Vasc. Interv. Radiol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"645","DOI":"10.2214\/AJR.12.9802","article-title":"Sonography-guided percutaneous liver biopsies in children","volume":"201","author":"Govender","year":"2013","journal-title":"AJR Am. J. Roentgenol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1097\/MPG.0b013e3182a0e0d8","article-title":"Percutaneous liver biopsy: Pathologic diagnosis and complications in children","volume":"57","author":"Short","year":"2013","journal-title":"J. Pediatr. Gastroenterol. Nutr."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1066","DOI":"10.2214\/AJR.20.23196","article-title":"Ultrasound-Guided Core Biopsy for Tissue Diagnosis in Pediatric Oncology: 16-Year Experience With 597 Biopsies","volume":"216","author":"Ilivitzki","year":"2021","journal-title":"AJR Am. J. Roentgenol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/S0168-8278(03)00191-0","article-title":"Impact of liver biopsy size on histological evaluation of chronic viral hepatitis: The smaller the sample, the milder the disease","volume":"39","author":"Colloredo","year":"2003","journal-title":"J. Hepatol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"710","DOI":"10.1309\/W3XCNT4HKFBN2G0B","article-title":"A systematic review of the quality of liver biopsy specimens","volume":"125","author":"Cholongitas","year":"2006","journal-title":"Am. J. Clin. Pathol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1017","DOI":"10.1002\/hep.22742","article-title":"American Association for the Study of Liver Diseases. Liver biopsy","volume":"49","author":"Rockey","year":"2009","journal-title":"Hepatology"},{"key":"ref_26","first-page":"S227","article-title":"Quality improvement guidelines for image-guided percutaneous biopsy in adults","volume":"14","author":"Cardella","year":"2003","journal-title":"J. Vasc. Interv. Radiol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1148\/radiology.204.1.9205229","article-title":"Liver biopsy: Effects of biopsy needle caliber on bleeding and tissue recovery","volume":"204","author":"Plecha","year":"1997","journal-title":"Radiology"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1148\/radiology.183.2.1561359","article-title":"Effect of needle gauge, level of anticoagulation, and target organ on bleeding associated with aspiration biopsy. Work in progress","volume":"183","author":"Gazelle","year":"1992","journal-title":"Radiology"}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/15\/9\/3497\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T01:32:33Z","timestamp":1777858353000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/15\/9\/3497"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,2]]},"references-count":28,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2026,5]]}},"alternative-id":["jcm15093497"],"URL":"https:\/\/doi.org\/10.3390\/jcm15093497","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,2]]}}}