{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T05:10:56Z","timestamp":1789017056916,"version":"build-2803163510"},"reference-count":34,"publisher":"MDPI AG","issue":"17","license":[{"start":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T00:00:00Z","timestamp":1788480000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Clin. Med.","JCM"],"abstract":"<jats:p>Background: Minimally invasive cardiac valve surgery (MIVS) provides distinct clinical advantages, yet annular suturing remains a technically demanding step. Automated annular suturing devices (RAM\u00ae) have been developed to standardize suture placement during valve replacement. This study evaluates the initial clinical feasibility, technical safety, and operational integration of automated suturing during its institutional adoption phase. Methods: We retrospectively evaluated 43 consecutive patients undergoing MIVS supported by the RAM\u00ae system (2021\u20132025), stratified into mitral valve replacements (RAM-MVR, n = 26) and aortic valve replacements (RAM-AVR, n = 17). Technical parameters, procedural safety metrics, and perioperative outcomes were descriptively analyzed and contextualized against our broader institutional MIVS platform using percutaneous femoral cannulation (n = 182). Results: Automated annular suturing achieved a 100% technical feasibility rate (43\/43, 95% CI: 91.8\u2013100.0%) with zero mechanical device failures or intraoperative suture-line disruptions (0%, 95% CI: 0.0\u20138.2%). In the RAM-MVR cohort, median cross-clamp and cardiopulmonary bypass (CPB) times were 73.0 min (IQR 64.0\u201391.0) and 114.5 min (IQR 94.8\u2013129.5), respectively. In RAM-AVR, median cross-clamp time was 75.0 min (IQR 71.0\u201383.0). Thirty-day mortality was 4.7% (2\/43, 95% CI: 0.6\u201315.8%), secondary to non-device-related medical complications in high-risk baseline patients. Postoperative echocardiography demonstrated no paravalvular regurgitation (0%, 95% CI: 0.0\u20138.2%). Conclusions: Initial institutional experience demonstrates that automated annular suturing is technically feasible and safe in minimally invasive mitral and aortic valve replacement. The system enables consistent procedural execution across valve positions. These observational data support automated suturing as a feasible alternative to manual suturing in MIVS workflows.<\/jats:p>","DOI":"10.3390\/jcm15176870","type":"journal-article","created":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T17:25:56Z","timestamp":1788542756000},"page":"6870","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Feasibility, Technical Safety, and Early Clinical Experience with an Automated Annular Suturing Device in Minimally Invasive Valve Replacement"],"prefix":"10.3390","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7340-7472","authenticated-orcid":false,"given":"Robert","family":"Balan","sequence":"first","affiliation":[{"name":"Doctoral School, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540142 Targu Mures, Romania"},{"name":"Department of Cardiac Surgery, Klinikum Passau, 94032 Passau, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Parwis","family":"Massoudy","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, Klinikum Passau, 94032 Passau, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9044-8866","authenticated-orcid":false,"given":"Marius Mihai","family":"Harpa","sequence":"additional","affiliation":[{"name":"Department of Surgery IV, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540142 Targu Mures, Romania"},{"name":"Department of Cardiovascular Surgery, Emergency Institute for Cardiovascular Diseases and Transplantation Targu Mures, 540136 Targu Mures, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Klara","family":"Br\u00eenzaniuc","sequence":"additional","affiliation":[{"name":"Department of Anatomy and Embryology, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540142 Targu Mures, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonah","family":"Schwarz","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, Klinikum Passau, 94032 Passau, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,9,4]]},"reference":[{"key":"ref_1","first-page":"315","article-title":"Evolution of the concept and practice of mitral valve repair","volume":"4","author":"Cohn","year":"2015","journal-title":"Ann. Surg."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1016\/j.jacc.2010.03.053","article-title":"Minimally-Invasive Valve Surgery","volume":"56","author":"Schmitto","year":"2010","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Holubec, T., Dahle, G., and Bonaros, N. (2023). Minimally Invasive Cardiac Surgery: State of the Art and Current Challenges. Front. Cardiovasc. Med., 10.","DOI":"10.3389\/fcvm.2023.1286868"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"564","DOI":"10.21037\/acs-2022-rmvs-26","article-title":"Historical Evolution of Robot-Assisted Cardiac Surgery: A 25-Year Journey","volume":"11","author":"Chitwood","year":"2022","journal-title":"Ann. Cardiothorac. Surg."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1450","DOI":"10.1016\/j.jtcvs.2016.02.030","article-title":"Mitral valve repair using robotic technology: Safe, effective, and durable","volume":"151","author":"Suri","year":"2016","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"498","DOI":"10.5606\/tgkdc.dergisi.2023.25404","article-title":"Minimally invasive versus conventional mitral valve surgery: A propensity score matching analysis","volume":"31","author":"Duman","year":"2023","journal-title":"Turk. J. Thorac. Cardiovasc. Surg."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1016\/j.jtcvs.2017.07.037","article-title":"Early Results of Robotically Assisted Mitral Valve Surgery","volume":"155","author":"Gillinov","year":"2018","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Harpa, M.M., Anitei, E.-D., Ghiragosian, C., Calburean, P., Opris, D.R., Banceu, M.C., Arbanasi, E.M., Suciu, H., and Al Hussein, H. (2025). Endoscopic Mitral Surgery in Noonan Syndrome\u2014Case Report and Considerations. J. Clin. Med., 14.","DOI":"10.3390\/jcm14020583"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1016\/j.ijsu.2010.10.007","article-title":"Cross-Clamp Time Is an Independent Predictor of Mortality and Morbidity in Low- and High-Risk Cardiac Patients","volume":"9","author":"Thalib","year":"2011","journal-title":"Int. J. Surg."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"814","DOI":"10.1053\/j.jvca.2008.08.004","article-title":"Cardiopulmonary Bypass Duration Is an Independent Predictor of Morbidity and Mortality after Cardiac Surgery","volume":"22","author":"Salis","year":"2008","journal-title":"J. Cardiothorac. Vasc. Anesth."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1355","DOI":"10.1001\/jamacardio.2021.4833","article-title":"The Challenge of Estimating Treatment Effects in Cardiac Surgery","volume":"6","author":"Gaudino","year":"2021","journal-title":"JAMA Cardiol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"941","DOI":"10.1016\/j.jtcvs.2018.08.017","article-title":"The art of mitral valve repair: Recreating nature or learning from it?","volume":"157","author":"Doenst","year":"2019","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Harpa, M.M., Oltean, S.F., Al Hussein, H., Anitei, D.E., Puscas, I.A., B\u0103nceu, C.M., Veres, M., Opri\u0219, D.R., Balau, R.A., and Suciu, H. (2024). Successful Treatment of Unilateral Pulmonary Edema as Minimally Invasive Mitral Valve Surgery Complication\u2014Case Presentation. J. Clin. Med., 13.","DOI":"10.3390\/jcm13247654"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1598","DOI":"10.1111\/jocs.14265","article-title":"What is the safety and efficacy of the use of automated fastener in heart valve surgery?","volume":"34","author":"Salmasi","year":"2019","journal-title":"J. Card. Surg."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1308\/rcsann.2019.0063","article-title":"Use of an automated knot fastener shortens operative times in minimally invasive mitral valve repair","volume":"101","author":"Perin","year":"2019","journal-title":"Ann. R. Coll. Surg. Engl."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1160","DOI":"10.1016\/j.athoracsur.2018.05.022","article-title":"Automated Titanium Fasteners Versus Hand-Tied Knots: A Randomized Controlled Trial","volume":"106","author":"Etiwy","year":"2018","journal-title":"Ann. Thorac. Surg."},{"key":"ref_17","first-page":"ivae112","article-title":"First experiences with automated annular suturing device in totally endoscopic aortic and mitral valve replacement","volume":"38","author":"Salamate","year":"2024","journal-title":"Interdiscip. Cardiovasc. Thorac. Surg."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1186\/s13019-021-01464-4","article-title":"Totally Endoscopic Mitral Valve Surgery: Early Experience in 188 Patients","volume":"16","author":"Chen","year":"2021","journal-title":"J. Cardiothorac. Surg."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Schwarz, J., Massoudy, P., Harpa, M.M., Czesla, M., Mogilansky, C., Br\u00eenzaniuc, K., Anitei, E.-D., and Balan, R. (2026). Evolution of Femoral Cannulation Techniques in Minimally Invasive Mitral Valve Surgery: A 10-Year Experience. Med. Sci., 14.","DOI":"10.3390\/medsci14020182"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Schaefer, A., Sarwari, H., Reichenspurner, H., and Conradi, L. (2021). Plug-Based Vascular Closure Device for Percutaneous Femoral Artery Closure in Minimally Invasive Valve Surgery. Front. Cardiovasc. Med., 8.","DOI":"10.3389\/fcvm.2021.682321"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1016\/j.jcin.2016.12.277","article-title":"Plug-Based Arteriotomy Closure Device for Large-Bore Access: Multicenter Prospective Study","volume":"10","author":"Latib","year":"2017","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1177\/11297298251325391","article-title":"Efficacy, safety, and complications of manta vascular closure device in VA-ECMO decannulation: A systematic review and meta-analysis","volume":"27","author":"Troisi","year":"2026","journal-title":"J. Vasc. Access."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2116","DOI":"10.1016\/j.athoracsur.2013.07.015","article-title":"Minimally Invasive Mitral Valve Surgery: Influence of Aortic Clamping Technique on Early Outcomes","volume":"96","author":"Mazine","year":"2013","journal-title":"Ann. Thorac. Surg."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1016\/j.athoracsur.2025.08.013","article-title":"Defining the Learning Curve in Minimally Invasive Cardiac Surgery: A Systematic Review and Meta-Analysis","volume":"121","author":"Elsebaie","year":"2026","journal-title":"Ann. Thorac. Surg."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1161\/CIRCULATIONAHA.112.001402","article-title":"Learning Minimally Invasive Mitral Valve Surgery: A Cumulative Sum Sequential Probability Analysis of 3895 Operations from a Single High-Volume Center","volume":"128","author":"Holzhey","year":"2013","journal-title":"Circulation"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"919","DOI":"10.1136\/bmjqs-2016-005526","article-title":"Comparison of Control Charts for Monitoring Clinical Performance Using Binary Data","volume":"26","author":"Neuburger","year":"2017","journal-title":"BMJ Qual. Saf."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1016\/S0003-4975(03)00680-5","article-title":"Analysis of the Learning Curve in Telerobotic, Beating Heart Coronary Artery Bypass Grafting: A 90 Patient Experience","volume":"76","author":"Novick","year":"2003","journal-title":"Ann. Thorac. Surg."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"iv5-10","DOI":"10.1136\/heart.88.suppl_4.iv5","article-title":"Anatomy of the mitral valve","volume":"88","author":"Ho","year":"2002","journal-title":"Heart"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"875","DOI":"10.1016\/j.carrev.2020.03.032","article-title":"Safety and Effectiveness of MANTA Vascular Closure Device After Large-Bore Mechanical Circulatory Support: Real-World Experience","volume":"21","author":"Gupta","year":"2020","journal-title":"Cardiovasc. Revascularization Med."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"169","DOI":"10.21037\/jovs.2016.11.04","article-title":"Evolution of a minimally invasive mitral valve program","volume":"2","author":"Czesla","year":"2016","journal-title":"J. Vis. Surg."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1110","DOI":"10.1001\/jamacardio.2022.3399","article-title":"Routine Ultrasonography Guidance for Femoral Vascular Access for Cardiac Procedures: The UNIVERSAL Randomized Clinical Trial","volume":"7","author":"Jolly","year":"2022","journal-title":"JAMA Cardiol."},{"key":"ref_32","first-page":"3","article-title":"Surgical and Pathological Anatomy of the Aortic Valve and Root","volume":"1","author":"Becker","year":"1996","journal-title":"Oper. Tech. Card. Thorac. Surg."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"2443","DOI":"10.21037\/jtd.2020.03.55","article-title":"In vitro comparison of everting vs. non-everting suture techniques for the implantation of a supra-annular biological heart valve","volume":"12","author":"Puluca","year":"2020","journal-title":"J. Thorac. Dis."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Li, B., Bai, S., Yue, G., Zhu, J., Zhang, M., Yang, B., Luo, J., Sun, Y., Zhang, L., and Wang, X. (2022). Safety and Effectiveness Outcomes of a Novel Automated Titanium Suture Fastener Device Applied for Heart Valve Surgery in an Ovine Model. Front. Cardiovasc. Med., 9.","DOI":"10.3389\/fcvm.2022.783208"}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/15\/17\/6870\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T04:40:13Z","timestamp":1789015213000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/15\/17\/6870"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,4]]},"references-count":34,"journal-issue":{"issue":"17","published-online":{"date-parts":[[2026,9]]}},"alternative-id":["jcm15176870"],"URL":"https:\/\/doi.org\/10.3390\/jcm15176870","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,4]]}}}