{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T23:37:29Z","timestamp":1794699449718,"version":"4.9.1"},"reference-count":25,"publisher":"MDPI AG","issue":"18","license":[{"start":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T00:00:00Z","timestamp":1789430400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Clin. Med.","JCM"],"abstract":"<jats:p>Background\/Objectives: Single-pass triple-rule-out computed tomography (CT) angiography (TRO-CTA) must compromise among differing pulmonary, coronary, and aortic contrast-transit times. Wide-area detector CT (WAD-CT) and dual-source CT (DSCT) offer different coverage, temporal resolution, and dose profiles, but direct comparative evidence for a sequential single-bolus strategy is limited in selected emergency patients with overlapping concern for acute coronary syndrome, pulmonary embolism, or acute aortic syndrome. We compared territory-specific image quality and radiation dose; diagnostic accuracy was not assessed. Methods: This retrospective study included 114 adults (WAD-CT, n = 60; DSCT, n = 54). After test-bolus timing, one weight-based diagnostic bolus was used for sequential pulmonary, electrocardiography-synchronized coronary, and non-gated aortic acquisitions. Attenuation, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), blinded dual-reader quality scores, and radiation dose were compared by territory. Results: Mean overall scores across the two readers were \u22653 for every examination in all phases. WAD-CT showed higher pulmonary trunk SNR (19.5 \u00b1 8.9 vs. 14.3 \u00b1 3.8; p = 0.002), higher ascending aortic SNR (24.9 \u00b1 11.4 vs. 14.2 \u00b1 3.0; p &lt; 0.001), lower coronary and aortic noise, and 38.1% lower total estimated dose (6.40 \u00b1 1.72 vs. 10.34 \u00b1 6.91 mSv; p &lt; 0.001). DSCT showed higher right coronary attenuation (671.8 \u00b1 186.7 vs. 466.4 \u00b1 128.9 Hounsfield units; p &lt; 0.001), no significant difference in right coronary SNR (p = 0.681), and less aortic-root pulsation artifact (p &lt; 0.001). Pulmonary- and coronary-phase overall scores were comparable. Conclusions: Both protocols provided acceptable territory-level image quality from one diagnostic bolus. WAD-CT provided lower coronary and aortic noise and estimated radiation dose, whereas DSCT provided higher coronary attenuation and less aortic-root pulsation artifact. Diagnostic accuracy and performance in subsegmental pulmonary arteries and distal or small coronary branches remain unestablished.<\/jats:p>","DOI":"10.3390\/jcm15187166","type":"journal-article","created":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T11:57:34Z","timestamp":1789473454000},"page":"7166","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Single-Bolus Sequential Triple-Rule-Out CT Angiography: Image Quality and Radiation Dose on Wide-Area Detector and Dual-Source CT"],"prefix":"10.3390","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6522-9883","authenticated-orcid":false,"given":"Hyun Jung","family":"Kim","sequence":"first","affiliation":[{"name":"Department of Radiology, Wonju Severance Christian Hospital, Wonju College of Medicine, Yonsei University, Wonju 26426, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"writing-original-draft","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"},{"role":"project-administration","vocabulary":"credit"}]},{"given":"Jin Woo","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Radiology, Wonju Severance Christian Hospital, Wonju College of Medicine, Yonsei University, Wonju 26426, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"},{"role":"writing-original-draft","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-0088-1921","authenticated-orcid":false,"given":"Sung-Jin","family":"Cha","sequence":"additional","affiliation":[{"name":"Department of Radiology, Wonju Severance Christian Hospital, Wonju College of Medicine, Yonsei University, Wonju 26426, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"investigation","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7420-6269","authenticated-orcid":false,"given":"Sung Min","family":"Ko","sequence":"additional","affiliation":[{"name":"Department of Radiology, Wonju Severance Christian Hospital, Wonju College of Medicine, Yonsei University, Wonju 26426, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"project-administration","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"},{"role":"writing-original-draft","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"visualization","vocabulary":"credit"},{"role":"resources","vocabulary":"credit"},{"role":"software","vocabulary":"credit"},{"role":"validation","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"},{"role":"funding-acquisition","vocabulary":"credit"}]}],"member":"1968","published-online":{"date-parts":[[2026,9,15]]},"reference":[{"key":"ref_1","first-page":"e368","article-title":"2021 AHA\/ACC\/ASE\/CHEST\/SAEM\/SCCT\/SCMR guideline for the evaluation and diagnosis of chest pain","volume":"144","author":"Gulati","year":"2021","journal-title":"Circulation"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"3720","DOI":"10.1093\/eurheartj\/ehad191","article-title":"2023 ESC guidelines for the management of acute coronary syndromes","volume":"44","author":"Byrne","year":"2023","journal-title":"Eur. Heart J."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1148\/radiol.2522082335","article-title":"Triple-rule-out CT angiography for evaluation of acute chest pain and possible acute coronary syndrome","volume":"252","author":"Halpern","year":"2009","journal-title":"Radiology"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1148\/radiol.2482072169","article-title":"Evaluation of a triple rule-out coronary CT angiography protocol: Use of 64-section CT in low- to moderate-risk emergency department patients suspected of having acute coronary syndrome","volume":"248","author":"Takakuwa","year":"2008","journal-title":"Radiology"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.1016\/j.acra.2009.03.013","article-title":"Comparison of image quality and arterial enhancement with a dedicated coronary CTA protocol versus a triple rule-out coronary CTA protocol","volume":"16","author":"Halpern","year":"2009","journal-title":"Acad. Radiol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1007\/s00330-007-0803-y","article-title":"Dual-source CT for chest pain assessment","volume":"18","author":"Johnson","year":"2008","journal-title":"Eur. Radiol."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Wang, K., Wang, X., Zheng, S., Li, C., Jin, L., and Li, M. (2022). Dedicated CCTA followed by high-pitch scanning versus TRO-CT for contrast media and radiation dose reduction: A retrospective study. Diagnostics, 12.","DOI":"10.3390\/diagnostics12112647"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Kim, Y.J., An, G.Y., Cha, S.J., and Ko, S.M. (2026). Sequential helical\u2013axial\u2013helical triple-rule-out CT angiography: Technical feasibility and territory-specific image quality in the emergency department. J. Clin. Med., 15.","DOI":"10.3390\/jcm15124640"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1186\/s43055-019-0003-1","article-title":"Triple-rule-out CT angiography for clinical decision making and early triage of acute chest pain patients: Use of 320-multislice CT angiography","volume":"50","author":"Eltabbakh","year":"2019","journal-title":"Egypt. J. Radiol. Nucl. Med."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1007\/s10140-025-02351-4","article-title":"Wide-detector CT-based optimized triple rule-out CT angiography for emergency chest pain: Reducing contrast and radiation without compromising diagnostic quality","volume":"32","author":"Zhang","year":"2025","journal-title":"Emerg. Radiol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"4654","DOI":"10.1007\/s00330-018-5426-y","article-title":"Triple-rule-out CT angiography using two axial scans with 16 cm wide-detector for radiation dose reduction","volume":"28","author":"Chen","year":"2018","journal-title":"Eur. Radiol."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Sabel, B.O., Buric, K., Karara, N., Thierfelder, K.M., Dinkel, J., Sommer, W.H., and Meinel, F.G. (2016). High-pitch CT pulmonary angiography in third-generation dual-source CT: Image quality in an unselected patient population. PLoS ONE, 11.","DOI":"10.1371\/journal.pone.0146949"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1093\/eurheartj\/ehp470","article-title":"Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition","volume":"31","author":"Achenbach","year":"2010","journal-title":"Eur. Heart J."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1793","DOI":"10.1016\/j.ejrad.2013.05.003","article-title":"Clinical utility of ultra-high-pitch dual-source thoracic CT imaging of acute pulmonary embolism in the emergency department: Are we one step closer towards a non-gated triple rule out?","volume":"82","author":"Hou","year":"2013","journal-title":"Eur. J. Radiol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1007\/s10554-008-9308-2","article-title":"Initial evaluation of coronary images from 320-detector row computed tomography","volume":"24","author":"Rybicki","year":"2008","journal-title":"Int. J. Cardiovasc. Imaging"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1148\/radiol.2483072098","article-title":"Optimal electrocardiographic pulsing windows and heart rate: Effect on image quality and radiation exposure at dual-source coronary CT angiography","volume":"248","author":"Weustink","year":"2008","journal-title":"Radiology"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1453","DOI":"10.1016\/S0140-6736(07)61602-X","article-title":"The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: Guidelines for reporting observational studies","volume":"370","author":"Altman","year":"2007","journal-title":"Lancet"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1148\/radiol.11101800","article-title":"CT dose index and patient dose: They are not the same thing","volume":"259","author":"McCollough","year":"2011","journal-title":"Radiology"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1148\/radiol.10100047","article-title":"Multisection CT protocols: Sex- and age-specific conversion factors used to determine effective dose from dose-length product","volume":"257","author":"Deak","year":"2010","journal-title":"Radiology"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","article-title":"The measurement of observer agreement for categorical data","volume":"33","author":"Landis","year":"1977","journal-title":"Biometrics"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1016\/0895-4356(90)90158-L","article-title":"High agreement but low kappa: I. The problems of two paradoxes","volume":"43","author":"Feinstein","year":"1990","journal-title":"J. Clin. Epidemiol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1007\/s10140-021-01911-8","article-title":"The triple rule out CT in acute chest pain: A challenge for emergency radiologists?","volume":"28","author":"Russo","year":"2021","journal-title":"Emerg. Radiol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1097\/RLI.0b013e3181c15842","article-title":"Saving dose in triple-rule-out computed tomography examination using a high-pitch dual spiral technique","volume":"45","author":"Sommer","year":"2010","journal-title":"Investig. Radiol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1416","DOI":"10.1007\/s00330-011-2088-4","article-title":"Low-dose triple-rule-out using 320-row-detector volume MDCT: Less contrast medium and lower radiation exposure","volume":"21","author":"Durmus","year":"2011","journal-title":"Eur. Radiol."},{"key":"ref_25","unstructured":"American College of Radiology (2026). ACR Manual on Contrast Media, American College of Radiology. Available online: https:\/\/www.acr.org\/Clinical-Resources\/Clinical-Tools-and-Reference\/Contrast-Manual."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/15\/18\/7166\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T12:12:00Z","timestamp":1789474320000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/15\/18\/7166"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,15]]},"references-count":25,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2026,9]]}},"alternative-id":["jcm15187166"],"URL":"https:\/\/doi.org\/10.3390\/jcm15187166","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,15]]}}}