{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T11:56:09Z","timestamp":1791201369776,"version":"4.2.0"},"reference-count":26,"publisher":"MDPI AG","issue":"19","license":[{"start":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T00:00:00Z","timestamp":1790985600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Clin. Med.","JCM"],"abstract":"<jats:p>Objectives: Aggregate pre-analytical rejection rates conflate specimen-quality failures and administrative events, which require distinct mitigation protocols. We disaggregated rejection events to isolate specimen-quality failures and benchmarked them against global frameworks. Methods: We conducted a 25-month retrospective audit (July 2023 to August 2025) of test orders received by the Al Rass General Hospital laboratory. Using an AI-assisted classification protocol, we isolated pre-analytical Specimen Quality Failures from operational and administrative events. We mapped Specimen Quality Failure causes into IFCC WG-LEPS Quality Indicators (QIs) and evaluated via Six Sigma metrics, IFCC benchmarks, and Pareto analysis\u2014stratified by laboratory section, sample type, priority, and work shift. Results: Of 905,018 test orders received, 35,476 were rejected (overall rejection rate 3.92%). However, the specimen-quality failures were 2.21% (\u03c3 = 3.51), with 15,495 entries excluded as operational events. Clotted samples (26.2%), hemolysis (23.0%), wrong sample type (20.2%), sample not received (7.8%), and insufficient volume (7.1%) together accounted for 84.3% of specimen quality failures (the Vital Few). Most individual categories scored Good (\u22654.0) on Sigma, despite a pooled Sigma of 3.51 (Acceptable). Benchmarking against IFCC WG-LEPS targets showed that 6 of 13 quality indicators, including clotted sample, wrong sample type, and insufficient volume, fell Below Minimum, demonstrating divergent absolute internal process capability metrics and population-relative external benchmark performance signals. STAT samples had a lower specimen quality failure rate than Routine samples (1.25% vs. 2.51%). Although the morning shift accounted for 80.98% of total rejections, only 53.4% represented true specimen quality failures. Conclusions: Headline laboratory rejection rates are inflated by operational and administrative events, necessitating partitioned reporting models. While individual Westgard Sigma scores demonstrate satisfactory absolute process capability across most specimen quality failure categories, cross-referencing against population-relative IFCC targets contextualizes these results and identifies areas performing in the lower international quartiles. Quality improvement strategies require structural changes and workforce training.<\/jats:p>","DOI":"10.3390\/jcm15197663","type":"journal-article","created":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T10:57:46Z","timestamp":1791197866000},"page":"7663","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Partitioning All-Cause Pre-Analytical Laboratory Rejections: A 25-Month Retrospective Audit of Specimen Quality Failures with Six Sigma, IFCC, and Pareto Analysis"],"prefix":"10.3390","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3347-6796","authenticated-orcid":false,"given":"Shoukat Ali","family":"Arain","sequence":"first","affiliation":[{"name":"Department of Pathology, College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"},{"role":"writing-original-draft","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"}]},{"given":"Abdullah Naji","family":"Alhawil","sequence":"additional","affiliation":[{"name":"College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"writing-original-draft","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"},{"role":"resources","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1820-1276","authenticated-orcid":false,"given":"Shahid Akhtar","family":"Akhund","sequence":"additional","affiliation":[{"name":"Department of Medical Education and Anatomy and Genetics, College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"methodology","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"writing-original-draft","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"},{"role":"validation","vocabulary":"credit"}]},{"given":"Mahnoor","family":"Ali","sequence":"additional","affiliation":[{"name":"College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"data-curation","vocabulary":"credit"},{"role":"validation","vocabulary":"credit"},{"role":"visualization","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"}]},{"given":"Salman","family":"Aldosari","sequence":"additional","affiliation":[{"name":"College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"data-curation","vocabulary":"credit"},{"role":"resources","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"}]},{"given":"Abdulwahab Z.","family":"Binjomah","sequence":"additional","affiliation":[{"name":"College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia"},{"name":"Bacterial Diseases & Special Pathogens, Public Health Authority, Riyadh 13352, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,10,3]]},"reference":[{"key":"ref_1","first-page":"12","article-title":"The add value of laboratory diagnostics: The many reasons why decision-makers should actually care","volume":"2","author":"Lippi","year":"2017","journal-title":"J. Lab. Precis. Med."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1515\/CCLM.2007.173","article-title":"\u201cPre-pre\u201d and \u201cpost-post\u201d analytical error: High-incidence patient safety hazards involving the clinical laboratory","volume":"45","author":"Laposata","year":"2007","journal-title":"Clin. Chem. Lab. Med."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"e2872021","DOI":"10.5935\/1676-2444.20210023","article-title":"Impact of pre-analytical errors on costs of clinical analysis laboratory","volume":"57","author":"Santos","year":"2021","journal-title":"J. Bras. Patol. Med. Lab."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.5858\/arpa.2013-0331-CP","article-title":"Clinical consequences of specimen rejection: A College of American Pathologists Q-Probes analysis of 78 clinical laboratories","volume":"138","author":"Karcher","year":"2014","journal-title":"Arch. Pathol. Lab. Med."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1607","DOI":"10.1093\/jalm\/jfab035","article-title":"The hidden cost of hemolyzed blood samples in the emergency department","volume":"6","author":"Phelan","year":"2021","journal-title":"J. Appl. Lab. Med."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1258\/acb.2009.009222","article-title":"The detection and prevention of errors in laboratory medicine","volume":"47","author":"Plebani","year":"2010","journal-title":"Ann. Clin. Biochem."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"e00303","DOI":"10.1016\/j.plabm.2022.e00303","article-title":"Blood specimen rejection rate in clinical laboratory: A systematic review and meta-analysis","volume":"33","author":"Getawa","year":"2023","journal-title":"Pract. Lab. Med."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"381","DOI":"10.5144\/0256-4947.2025.381","article-title":"Frequencies and causes of pre-analytical errors in a tertiary care hospital laboratory in Saudi Arabia","volume":"45","author":"Alenezy","year":"2025","journal-title":"Ann. Saudi Med."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"e29853","DOI":"10.1097\/MD.0000000000029853","article-title":"Analysis of preanalytical errors in a clinical chemistry laboratory: A 2-year study","volume":"101","author":"Alcantara","year":"2022","journal-title":"Medicine"},{"key":"ref_10","first-page":"e34444","article-title":"An overview of complete blood count sample rejection rates in a clinical hematology laboratory due to various preanalytical errors","volume":"15","author":"Noor","year":"2023","journal-title":"Cureus"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"643","DOI":"10.4103\/aam.aam_132_24","article-title":"Preanalytical phase: Evaluation of specimen rejection rates and reasons from different hospital units during coronavirus disease 2019 pandemic in Saudi Arabia","volume":"24","author":"Jeraiby","year":"2025","journal-title":"Ann. Afr. Med."},{"key":"ref_12","first-page":"943","article-title":"Performance criteria and quality indicators for the pre-analytical phase","volume":"53","author":"Plebani","year":"2015","journal-title":"Clin. Chem. Lab. Med."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/j.cca.2019.07.007","article-title":"Pre-analytical quality indicators in laboratory medicine: Performance of laboratories participating in the IFCC working group \u201cLaboratory Errors and Patient Safety\u201d project","volume":"497","author":"Sciacovelli","year":"2019","journal-title":"Clin. Chim. Acta"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1309\/V50H4FRVVWX12C79","article-title":"The quality of laboratory testing today: An assessment of sigma metrics for analytic quality using performance data from proficiency testing surveys and the CLIA criteria for acceptable performance","volume":"125","author":"Westgard","year":"2006","journal-title":"Am. J. Clin. Pathol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"688","DOI":"10.1515\/cclm-2022-1143","article-title":"Quality indicators in laboratory medicine: State-of-the-art, quality specifications and future strategies","volume":"61","author":"Sciacovelli","year":"2023","journal-title":"Clin. Chem. Lab. Med."},{"key":"ref_16","first-page":"S70","article-title":"Frequency and types of pre-analytical errors in a clinical laboratory of a specialized healthcare hospital","volume":"40","author":"Tasneem","year":"2024","journal-title":"Pak. J. Med. Sci."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"750","DOI":"10.1515\/CCLM.2006.123","article-title":"Errors in clinical laboratories or errors in laboratory medicine?","volume":"44","author":"Plebani","year":"2006","journal-title":"Clin. Chem. Lab. Med."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"764","DOI":"10.1515\/CCLM.2008.170","article-title":"Haemolysis: An overview of the leading cause of unsuitable specimens in clinical laboratories","volume":"46","author":"Lippi","year":"2008","journal-title":"Clin. Chem. Lab. Med."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1186\/s12959-016-0123-z","article-title":"Pre-analytical issues in the haemostasis laboratory: Guidance for the clinical laboratories","volume":"14","author":"Magnette","year":"2016","journal-title":"Thromb. J."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"020503","DOI":"10.11613\/BM.2018.020503","article-title":"Sigma metrics in laboratory medicine revisited: We are on the right road with the wrong map","volume":"28","author":"Oosterhuis","year":"2018","journal-title":"Biochem. Med."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"777","DOI":"10.1111\/ijlh.14344","article-title":"International Council for Standardization in Haematology (ICSH) recommendations for the performance and interpretation of activated partial thromboplastin time and prothrombin time mixing tests","volume":"46","author":"Adcock","year":"2024","journal-title":"Int. J. Lab. Hematol."},{"key":"ref_22","first-page":"99","article-title":"Common pre-analytical errors in microbiology samples: An observational study","volume":"15","author":"Pradhan","year":"2023","journal-title":"CME J. Geriatr. Med."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"588","DOI":"10.5858\/2007-131-588-CLSRWT","article-title":"Clinical laboratory specimen rejection\u2014Association with the site of patient care and patients\u2019 characteristics: Findings from a single health care organization","volume":"131","author":"Stark","year":"2007","journal-title":"Arch. Pathol. Lab. Med."},{"key":"ref_24","first-page":"519","article-title":"A quality improvement initiative to reduce rejected laboratory samples and enhance specimen acceptability","volume":"47","author":"Gupta","year":"2021","journal-title":"Jt. Comm. J. Qual. Patient Saf."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"988","DOI":"10.1016\/j.clinbiochem.2012.06.019","article-title":"Effectiveness of barcoding for reducing patient specimen and laboratory testing identification errors: A Laboratory Medicine Best Practices systematic review and meta-analysis","volume":"45","author":"Snyder","year":"2012","journal-title":"Clin. Biochem."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"a1242","DOI":"10.4102\/phcfm.v9i1.1242","article-title":"The effect of phlebotomy training on blood sample rejection and phlebotomy knowledge of primary health care providers in Cape Town: A quasi-experimental study","volume":"9","author":"Abbas","year":"2017","journal-title":"Afr. J. Prim. Health Care Fam. Med."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/15\/19\/7663\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T11:10:10Z","timestamp":1791198610000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/15\/19\/7663"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,3]]},"references-count":26,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2026,10]]}},"alternative-id":["jcm15197663"],"URL":"https:\/\/doi.org\/10.3390\/jcm15197663","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,3]]}}}