{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T23:28:36Z","timestamp":1790810916122,"version":"4.1.0"},"reference-count":85,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2019,8,7]],"date-time":"2019-08-07T00:00:00Z","timestamp":1565136000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["PU 219\/2-1"],"award-info":[{"award-number":["PU 219\/2-1"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Electrical impedance tomography (EIT) is a bedside monitoring tool that noninvasively visualizes local ventilation and arguably lung perfusion distribution. This article reviews and discusses both methodological and clinical aspects of thoracic EIT. Initially, investigators addressed the validation of EIT to measure regional ventilation. Current studies focus mainly on its clinical applications to quantify lung collapse, tidal recruitment, and lung overdistension to titrate positive end-expiratory pressure (PEEP) and tidal volume. In addition, EIT may help to detect pneumothorax. Recent studies evaluated EIT as a tool to measure regional lung perfusion. Indicator-free EIT measurements might be sufficient to continuously measure cardiac stroke volume. The use of a contrast agent such as saline might be required to assess regional lung perfusion. As a result, EIT-based monitoring of regional ventilation and lung perfusion may visualize local ventilation and perfusion matching, which can be helpful in the treatment of patients with acute respiratory distress syndrome (ARDS).<\/jats:p>","DOI":"10.3390\/jcm8081176","type":"journal-article","created":{"date-parts":[[2019,8,7]],"date-time":"2019-08-07T10:56:38Z","timestamp":1565175398000},"page":"1176","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":141,"title":["Electrical Impedance Tomography for Cardio-Pulmonary Monitoring"],"prefix":"10.3390","volume":"8","author":[{"given":"Christian","family":"Putensen","sequence":"first","affiliation":[{"name":"Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, 53127 Bonn, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1071-1861","authenticated-orcid":false,"given":"Benjamin","family":"Hentze","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, 53127 Bonn, Germany"},{"name":"Chair for Medical Information Technology, RWTH Aachen University, 52074 Aachen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Muenster","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, 53127 Bonn, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Muders","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, 53127 Bonn, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2019,8,7]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1917","DOI":"10.1007\/s00134-012-2684-z","article-title":"Electrical impedance tomography: The holy grail of ventilation and perfusion monitoring?","volume":"38","author":"Leonhardt","year":"2012","journal-title":"Intensive Care Med."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1136\/thoraxjnl-2016-208357","article-title":"Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: Consensus statement of the TRanslational EIT developmeNt stuDy group","volume":"72","author":"Frerichs","year":"2017","journal-title":"Thorax"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Posada-Quintero, H.F., Reljin, N., Eaton-Robb, C., Noh, Y., Riistama, J., and Chon, K.H. (2018). Analysis of Consistency of Transthoracic Bioimpedance Measurements Acquired with Dry Carbon Black PDMS Electrodes, Adhesive Electrodes, and Wet Textile Electrodes. Sensors, 18.","DOI":"10.3390\/s18061719"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"10895","DOI":"10.3390\/s140610895","article-title":"The theory and fundamentals of bioimpedance analysis in clinical status monitoring and diagnosis of diseases","volume":"14","author":"Khalil","year":"2014","journal-title":"Sensors"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1186\/s13054-015-1161-9","article-title":"Influence of different electrode belt positions on electrical impedance tomography imaging of regional ventilation: A prospective observational study","volume":"20","author":"Karsten","year":"2016","journal-title":"Crit. Care"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1097\/CCM.0b013e3181958d2f","article-title":"Principles of electrical impedance tomography and its clinical application","volume":"37","author":"Bodenstein","year":"2009","journal-title":"Crit. Care Med."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1088\/0967-3334\/32\/7\/S01","article-title":"Adjacent stimulation and measurement patterns considered harmful","volume":"32","author":"Adler","year":"2011","journal-title":"Physiol. Meas."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Bacharach, S.L., and Nijhoff, M. (1986). Recent developments in applied potential tomography-APT. Information Processing in Medical Imaging, Springer.","DOI":"10.1007\/978-94-009-4261-5"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1109\/TBME.1987.326032","article-title":"Comparing reconstruction algorithms for electrical impedance tomography","volume":"34","author":"Yorkey","year":"1987","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"S35","DOI":"10.1088\/0967-3334\/30\/6\/S03","article-title":"GREIT: A unified approach to 2D linear EIT reconstruction of lung images","volume":"30","author":"Adler","year":"2009","journal-title":"Physiol. Meas."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1088\/0143-0815\/12\/4\/009","article-title":"Studies on the effect of the third dimension on a two-dimensional electrical impedance tomography system","volume":"12","author":"Rabbani","year":"1991","journal-title":"Clin. Phys. Physiol. Meas."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1088\/0967-3334\/37\/6\/785","article-title":"3D EIT image reconstruction with GREIT","volume":"37","author":"Grychtol","year":"2016","journal-title":"Physiol. Meas."},{"key":"ref_13","unstructured":"Adler, A., Proenca, M., Braun, F., Brunner, J., and Sola, J. (2017, January 21\u201324). Origins of Cardiosynchronous Signals in EIT. Proceedings of the 18th International Conference on Biomedical Applications of Electrical Impedance Tomography, Dartmouth College, Hanover, NH, USA."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"A161","DOI":"10.1088\/0967-3334\/16\/3A\/016","article-title":"Changes in the thoracic impedance distribution under different ventilatory conditions","volume":"16","author":"Hahn","year":"1995","journal-title":"Physiol. Meas."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1762","DOI":"10.1152\/jappl.1997.83.5.1762","article-title":"Monitoring changes in lung air and liquid volumes with electrical impedance tomography","volume":"83","author":"Adler","year":"1997","journal-title":"J. Appl. Physiol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1007\/s10877-006-9021-4","article-title":"Electrical impedance tomography\u2019s correlation to lung volume is not influenced by anthropometric parameters","volume":"20","author":"Marquis","year":"2006","journal-title":"J. Clin. Monit. Comput."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1007\/s00134-002-1555-4","article-title":"End-expiratory lung impedance change enables bedside monitoring of end-expiratory lung volume change","volume":"29","author":"Hinz","year":"2003","journal-title":"Intensive Care Med."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1068","DOI":"10.1111\/j.1399-6576.2011.02511.x","article-title":"Positive end-expiratory pressure-induced changes in end-expiratory lung volume measured by spirometry and electric impedance tomography","volume":"55","author":"Grivans","year":"2011","journal-title":"Acta Anaesthesiol. Scand."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1362","DOI":"10.1007\/s00134-009-1512-6","article-title":"Lung volume calculated from electrical impedance tomography in ICU patients at different PEEP levels","volume":"35","author":"Bikker","year":"2009","journal-title":"Intensive Care Med."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1097\/CCM.0B013E3181652EDD","article-title":"Electrical impedance tomography compared with thoracic computed tomography during a slow inflation maneuver in experimental models of lung injury","volume":"36","author":"Wrigge","year":"2008","journal-title":"Crit. Care Med."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1152\/japplphysiol.00081.2002","article-title":"Detection of local lung air content by electrical impedance tomography compared with electron beam CT","volume":"93","author":"Frerichs","year":"2002","journal-title":"J. Appl. Physiol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1378\/chest.124.1.314","article-title":"Regional ventilation by electrical impedance tomography: A comparison with ventilation scintigraphy in pigs","volume":"124","author":"Hinz","year":"2003","journal-title":"Chest"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"3891","DOI":"10.1097\/00003246-200012000-00025","article-title":"Monitoring of recruitment and derecruitment by electrical impedance tomography in a model of acute lung injury","volume":"28","author":"Kunst","year":"2000","journal-title":"Crit. Care Med."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"R193","DOI":"10.1186\/cc10354","article-title":"Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial","volume":"15","author":"Bikker","year":"2011","journal-title":"Crit. Care"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1953","DOI":"10.1007\/s00134-010-1995-1","article-title":"Regional tidal ventilation and compliance during a stepwise vital capacity manoeuvre","volume":"36","author":"Dargaville","year":"2010","journal-title":"Intensive Care Med."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1186\/s13054-019-2417-6","article-title":"Heterogeneity of regional inflection points from pressure-volume curves assessed by electrical impedance tomography","volume":"23","author":"Scaramuzzo","year":"2019","journal-title":"Crit. Care"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1097\/00003246-200001000-00029","article-title":"Regional pressure volume curves by electrical impedance tomography in a model of acute lung injury","volume":"28","author":"Kunst","year":"2000","journal-title":"Crit. Care Med."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1111\/j.1399-6576.2006.00958.x","article-title":"Regional pulmonary pressure volume curves in mechanically ventilated patients with acute respiratory failure measured by electrical impedance tomography","volume":"50","author":"Hinz","year":"2006","journal-title":"Acta Anaesthesiol. Scand."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1097\/CCM.0000000000002233","article-title":"Mapping Regional Differences of Local Pressure-Volume Curves With Electrical Impedance Tomography","volume":"45","author":"Beda","year":"2017","journal-title":"Crit. Care Med."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1132","DOI":"10.1007\/s00134-009-1447-y","article-title":"Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography","volume":"35","author":"Costa","year":"2009","journal-title":"Intensive Care Med."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1097\/ALN.0000000000002638","article-title":"Lung Recruitment in Obese Patients with Acute Respiratory Distress Syndrome","volume":"130","author":"Fumagalli","year":"2019","journal-title":"Anesthesiology"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1111\/j.1399-6576.1998.tb05308.x","article-title":"Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography","volume":"42","author":"Frerichs","year":"1998","journal-title":"Acta Anaesthesiol. Scand."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1088\/0967-3334\/28\/7\/S18","article-title":"Protective ventilation using electrical impedance tomography","volume":"28","author":"Luepschen","year":"2007","journal-title":"Physiol. Meas."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1186\/s12938-019-0701-y","article-title":"Integrated EIT system for functional lung ventilation imaging","volume":"18","author":"Jang","year":"2019","journal-title":"BioMed Eng. OnLine"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1264","DOI":"10.1007\/978-3-319-32703-7_242","article-title":"Center of Ventilation\u2014Methods of Calculation Using Electrical Impedance Tomography and the Influence of Image Segmentation","volume":"Volume 57","author":"Kyriacou","year":"2016","journal-title":"XIV Mediterranean Conference on Medical and Biological Engineering and Computing 2016"},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Bauer, M., Opitz, A., Filser, J., Jansen, H., Meffert, R.H., Germer, C.T., Roewer, N., Muellenbach, R.M., and Kredel, M. (2019). Perioperative redistribution of regional ventilation and pulmonary function: A prospective observational study in two cohorts of patients at risk for postoperative pulmonary complications. BMC Anesthesiol., 19.","DOI":"10.1186\/s12871-019-0805-8"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1900","DOI":"10.1007\/s00134-009-1589-y","article-title":"Evaluation of an electrical impedance tomography-based Global Inhomogeneity Index for pulmonary ventilation distribution","volume":"35","author":"Zhao","year":"2009","journal-title":"Intensive Care Med."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Zhao, Z., Pulletz, S., Frerichs, I., M\u00fcller-Lisse, U., and M\u00f6ller, K. (2014). The EIT-based global inhomogeneity index is highly correlated with regional lung opening in patients with acute respiratory distress syndrome. BMC Res. Notes, 7.","DOI":"10.1186\/1756-0500-7-82"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1093\/bja\/aew188","article-title":"Perioperative assessment of regional ventilation during changing body positions and ventilation conditions by electrical impedance tomography","volume":"117","author":"Ukere","year":"2016","journal-title":"Br. J. Anaesth."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1186\/s13054-017-1931-7","article-title":"Variation of poorly ventilated lung units (silent spaces) measured by electrical impedance tomography to dynamically assess recruitment","volume":"22","author":"Spadaro","year":"2018","journal-title":"Crit. Care"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1097\/CCM.0b013e318236f452","article-title":"Tidal recruitment assessed by electrical impedance tomography and computed tomography in a porcine model of lung injury*","volume":"40","author":"Muders","year":"2012","journal-title":"Crit. Care Med."},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Muders, T., Hentze, B., Simon, P., Girrbach, F., Doebler, M.R.G., Leonhardt, S., Wrigge, H., and Putensen, C. (2019). A Modified Method to Assess Tidal Recruitment by Electrical Impedance Tomography. JCM, 8.","DOI":"10.3390\/jcm8081161"},{"key":"ref_43","first-page":"1024","article-title":"Regional intratidal gas distribution in acute lung injury and acute respiratory distress syndrome assessed by electric impedance tomography","volume":"76","author":"Lowhagen","year":"2010","journal-title":"Minerva Anestesiol."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1186\/s13054-018-2137-3","article-title":"Regional expiratory time constants in severe respiratory failure estimated by electrical impedance tomography: A feasibility study","volume":"22","author":"Karagiannidis","year":"2018","journal-title":"Crit. Care"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1164\/rccm.200301-133OC","article-title":"Imbalances in regional lung ventilation: A validation study on electrical impedance tomography","volume":"169","author":"Victorino","year":"2004","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"L8","DOI":"10.1152\/ajplung.00463.2015","article-title":"Regional lung response to bronchodilator reversibility testing determined by electrical impedance tomography in chronic obstructive pulmonary disease","volume":"311","author":"Vogt","year":"2016","journal-title":"Am. J. Physiol. Lung Cell Mol. Physiol."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"R100","DOI":"10.1186\/cc9036","article-title":"Bedside measurement of changes in lung impedance to monitor alveolar ventilation in dependent and non-dependent parts by electrical impedance tomography during a positive end-expiratory pressure trial in mechanically ventilated intensive care unit patients","volume":"14","author":"Bikker","year":"2010","journal-title":"Crit. Care"},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Zick, G., Elke, G., Becher, T., Sch\u00e4dler, D., Pulletz, S., Freitag-Wolf, S., Weiler, N., and Frerichs, I. (2013). Effect of PEEP and tidal volume on ventilation distribution and end-expiratory lung volume: A prospective experimental animal and pilot clinical study. PLoS ONE, 8.","DOI":"10.1371\/journal.pone.0072675"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"e3820","DOI":"10.1097\/MD.0000000000003820","article-title":"Assessment of Lung Recruitment by Electrical Impedance Tomography and Oxygenation in ARDS Patients","volume":"95","author":"Yun","year":"2016","journal-title":"Medicine (Baltimore)"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"1664","DOI":"10.1097\/CCM.0b013e318287f6e7","article-title":"Topographic distribution of tidal ventilation in acute respiratory distress syndrome: Effects of positive end-expiratory pressure and pressure support","volume":"41","author":"Mauri","year":"2013","journal-title":"Crit. Care Med."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1186\/s13613-019-0484-0","article-title":"Positive end-expiratory pressure titration with electrical impedance tomography and pressure\u2013volume curve in severe acute respiratory distress syndrome","volume":"9","author":"Zhao","year":"2019","journal-title":"Ann. Intensive Care"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1164\/rccm.201605-1055OC","article-title":"Bedside Contribution of Electrical Impedance Tomography to Setting Positive End-Expiratory Pressure for Extracorporeal Membrane Oxygenation-treated Patients with Severe Acute Respiratory Distress Syndrome","volume":"196","author":"Franchineau","year":"2017","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"1453","DOI":"10.1007\/s00134-017-4890-1","article-title":"Optimum support by high-flow nasal cannula in acute hypoxemic respiratory failure: Effects of increasing flow rates","volume":"43","author":"Mauri","year":"2017","journal-title":"Intensive Care Med."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"1194","DOI":"10.1093\/bja\/aex192","article-title":"Individualized positive end-expiratory pressure in obese patients during general anaesthesia: A randomized controlled clinical trial using electrical impedance tomography","volume":"119","author":"Nestler","year":"2017","journal-title":"Br. J. Anaesth."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"S187","DOI":"10.1088\/0967-3334\/27\/5\/S16","article-title":"Imaging pathologic pulmonary air and fluid accumulation by functional and absolute EIT","volume":"27","author":"Hahn","year":"2006","journal-title":"Physiol. Meas."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"1230","DOI":"10.1097\/CCM.0b013e31816a0380","article-title":"Real-time detection of pneumothorax using electrical impedance tomography","volume":"36","author":"Costa","year":"2008","journal-title":"Crit. Care Med."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1164\/rccm.201609-1780LE","article-title":"Monitoring of Pneumothorax Appearance with Electrical Impedance Tomography during Recruitment Maneuvers","volume":"195","author":"Morais","year":"2017","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"1219","DOI":"10.1016\/j.bja.2018.02.030","article-title":"Characteristic pattern of pleural effusion in electrical impedance tomography images of critically ill patients","volume":"120","author":"Becher","year":"2018","journal-title":"Br. J. Anaesth."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"1166","DOI":"10.1111\/aas.12959","article-title":"Spontaneous breathing trials after prolonged mechanical ventilation monitored by electrical impedance tomography: An observational study","volume":"61","author":"Zhao","year":"2017","journal-title":"Acta Anaesthesiol. Scand."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1007\/s00134-006-0425-x","article-title":"Regional lung derecruitment after endotracheal suction during volume- or pressure-controlled ventilation: A study using electric impedance tomography","volume":"33","author":"Lindgren","year":"2007","journal-title":"Intensive Care Med."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1093\/bja\/aen166","article-title":"Electrical impedance tomography to confirm correct placement of double-lumen tube: A feasibility study","volume":"101","author":"Steinmann","year":"2008","journal-title":"Br. J. Anaesth."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"3019","DOI":"10.1097\/CCM.0b013e31818b308b","article-title":"Excessive tidal volume from breath stacking during lung-protective ventilation for acute lung injury","volume":"36","author":"Pohlman","year":"2008","journal-title":"Crit. Care Med."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"1420","DOI":"10.1164\/rccm.201303-0539OC","article-title":"Spontaneous effort causes occult pendelluft during mechanical ventilation","volume":"188","author":"Yoshida","year":"2013","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1152\/japplphysiol.01090.2010","article-title":"Regional lung perfusion estimated by electrical impedance tomography in a piglet model of lung collapse","volume":"112","author":"Borges","year":"2012","journal-title":"J. Appl. Physiol."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"065004","DOI":"10.1088\/1361-6579\/aac7ae","article-title":"Regional lung ventilation and perfusion by electrical impedance tomography compared to single-photon emission computed tomography","volume":"39","author":"Hentze","year":"2018","journal-title":"Physiol. Meas."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"2127","DOI":"10.1152\/japplphysiol.00286.2012","article-title":"Comment on Borges et al. \u201cregional lung perfusion estimated by electrical impedance tomography in a piglet model of lung collapse\u201d","volume":"112","author":"Hellige","year":"2012","journal-title":"J. Appl. Physiol."},{"key":"ref_67","doi-asserted-by":"crossref","unstructured":"Bluth, T., Kiss, T., Kircher, M., Braune, A., Bozsak, C., Huhle, R., Scharffenberg, M., Herzog, M., Roegner, J., and Herzog, P. (2019). Measurement of relative lung perfusion with electrical impedance and positron emission tomography: An experimental comparative study. Br. J. Anaesth.","DOI":"10.1016\/j.bja.2019.04.056"},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1088\/0143-0815\/13\/A\/034","article-title":"Blood flow imaging using electrical impedance tomography","volume":"13","author":"Brown","year":"1992","journal-title":"Clin. Phys. Physiol. Meas."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"646","DOI":"10.1109\/TMI.2002.800585","article-title":"Regional lung perfusion as determined by electrical impedance tomography in comparison with electron beam CT imaging","volume":"21","author":"Frerichs","year":"2002","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1111\/aas.12455","article-title":"Real-time ventilation and perfusion distributions by electrical impedance tomography during one-lung ventilation with capnothorax","volume":"59","author":"Reinius","year":"2015","journal-title":"Acta Anaesthesiol. Scand."},{"key":"ref_71","doi-asserted-by":"crossref","unstructured":"Hentze, B., Muders, T., Luepschen, H., Leonhardt, S., Putensen, C., and Walter, M. (2017, January 11\u201315). Gamma-variate modeling of indicator dilution curves in electrical impedance tomography. Proceedings of the 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Seogwipo, Korea.","DOI":"10.1109\/EMBC.2017.8037635"},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1088\/0967-3334\/19\/2\/013","article-title":"Pulmonary perfusion measured by means of electrical impedance tomography","volume":"19","author":"Kunst","year":"1998","journal-title":"Physiol. Meas."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"R37","DOI":"10.1186\/cc9985","article-title":"Measurement of ventilation and cardiac related impedance changes with electrical impedance tomography","volume":"15","author":"Grant","year":"2011","journal-title":"Crit. Care"},{"key":"ref_74","first-page":"122","article-title":"Electrical Impedance Tomography for hemodynamic monitoring","volume":"2012","author":"Leonhardt","year":"2012","journal-title":"Conf. Proc. IEEE Eng. Med. Biol. Soc."},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1088\/0143-0815\/9\/4A\/008","article-title":"Methods of cardiac gating applied potential tomography","volume":"9","author":"Brown","year":"1988","journal-title":"Clin. Phys. Physiol. Meas."},{"key":"ref_76","doi-asserted-by":"crossref","unstructured":"Braun, F., Proen\u00e7a, M., Adler, A., Riedel, T., Thiran, J.-P., and Sol\u00e0, J. (2018). Accuracy and reliability of noninvasive stroke volume monitoring via ECG-gated 3D electrical impedance tomography in healthy volunteers. PLoS ONE, 13.","DOI":"10.1371\/journal.pone.0191870"},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1159\/000193994","article-title":"Assessment of changes in distribution of lung perfusion by electrical impedance tomography","volume":"77","author":"Frerichs","year":"2009","journal-title":"Respiration"},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1088\/0143-0815\/13\/A\/037","article-title":"Pulmonary perfusion and ventricular ejection imaging by frequency domain filtering of EIT (electrical impedance tomography) images","volume":"13","author":"Zadehkoochak","year":"1992","journal-title":"Clin. Phys. Physiol. Meas."},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1088\/0967-3334\/29\/6\/S01","article-title":"Dynamic separation of pulmonary and cardiac changes in electrical impedance tomography","volume":"29","author":"Deibele","year":"2008","journal-title":"Physiol. Meas."},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1088\/0967-3334\/19\/4\/003","article-title":"Ventilation and perfusion imaging by electrical impedance tomography: A comparison with radionuclide scanning","volume":"19","author":"Kunst","year":"1998","journal-title":"Physiol. Meas."},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1111\/j.1399-6576.2008.01847.x","article-title":"Monitoring pulmonary perfusion by electrical impedance tomography: An evaluation in a pig model","volume":"53","author":"Fagerberg","year":"2009","journal-title":"Acta Anaesthesiol. Scand."},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1213\/ANE.0000000000000241","article-title":"Recent advances in and limitations of cardiac output monitoring by means of electrical impedance tomography","volume":"119","author":"Pikkemaat","year":"2014","journal-title":"Anesth. Analg."},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1088\/0967-3334\/21\/2\/308","article-title":"Determination of stroke volume by means of electrical impedance tomography","volume":"21","author":"Janse","year":"2000","journal-title":"Physiol. Meas."},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"014003","DOI":"10.1088\/1361-6579\/aa9828","article-title":"Limitations and challenges of EIT-based monitoring of stroke volume and pulmonary artery pressure","volume":"39","author":"Braun","year":"2018","journal-title":"Physiol. Meas."},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"1075","DOI":"10.1088\/0967-3334\/36\/6\/1075","article-title":"Influence of heart motion on cardiac output estimation by means of electrical impedance tomography: A case study","volume":"36","author":"Braun","year":"2015","journal-title":"Physiol. Meas."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/8\/8\/1176\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:09:09Z","timestamp":1760188149000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/8\/8\/1176"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8,7]]},"references-count":85,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2019,8]]}},"alternative-id":["jcm8081176"],"URL":"https:\/\/doi.org\/10.3390\/jcm8081176","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,8,7]]}}}