{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T16:40:32Z","timestamp":1787935232653,"version":"build-2784847793"},"reference-count":115,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2019,8,13]],"date-time":"2019-08-13T00:00:00Z","timestamp":1565654400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Given the tremendous progress in interventional cardiology over the last decade, a growing number of older patients, who have more comorbidities and more complex coronary artery disease, are being considered for technically challenging and high-risk percutaneous coronary interventions (PCI). The success of performing such complex PCI is increasingly dependent on the availability and improvement of mechanical circulatory support (MCS) devices, which aim to provide hemodynamic support and left ventricular (LV) unloading to enable safe and successful coronary revascularization. MCS as an adjunct to high-risk PCI may, therefore, be an important component for improvement in clinical outcomes. MCS devices in this setting can be used for two main clinical conditions: patients who present with cardiogenic shock complicating acute myocardial infarction (AMI) and those undergoing technically complex and high-risk PCI without having overt cardiogenic shock. The current article reviews the advancement in the use of various devices in both AMI complicated by cardiogenic shock and complex high-risk PCI, highlights the available hemodynamic and clinical data associated with the use of MCS devices, and presents suggestive management strategies focusing on appropriate patient selection and optimal timing and support to potentially increase the clinical benefit from utilizing these devices during PCI in this high-risk group of patients.<\/jats:p>","DOI":"10.3390\/jcm8081209","type":"journal-article","created":{"date-parts":[[2019,8,14]],"date-time":"2019-08-14T03:59:26Z","timestamp":1565755166000},"page":"1209","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":28,"title":["Utilization of Percutaneous Mechanical Circulatory Support Devices in Cardiogenic Shock Complicating Acute Myocardial Infarction and High-Risk Percutaneous Coronary Interventions"],"prefix":"10.3390","volume":"8","author":[{"given":"Rabea","family":"Asleh","sequence":"first","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jon","family":"Resar","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2019,8,13]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2295","DOI":"10.1161\/CIRCULATIONAHA.114.011541","article-title":"Surgical ineligibility and mortality among patients with unprotected left main or multivessel coronary artery disease undergoing percutaneous coronary intervention","volume":"130","author":"Waldo","year":"2014","journal-title":"Circulation"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1016\/j.jcin.2016.02.046","article-title":"A practical approach to mechanical circulatory support in patients undergoing percutaneous coronary intervention an interventional perspective","volume":"9","author":"Atkinson","year":"2016","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1001\/jama.2010.1190","article-title":"BCSI-1 Investigators. Elective intra-aortic balloon counterpulsation during high-risk percutaneous coronary intervention: A randomized controlled trial","volume":"304","author":"Perera","year":"2010","journal-title":"JAMA"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1717","DOI":"10.1161\/CIRCULATIONAHA.112.098194","article-title":"A prospective, randomized clinical trial of hemodynamic support with impella 2.5 versus intra-aortic balloon pump in patients undergoing high-risk percutaneous coronary intervention: The PROTECT II study","volume":"126","author":"Kleiman","year":"2012","journal-title":"Circulation"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1056\/NEJMoa1208410","article-title":"Intraaortic balloon support for myocardial infarction with cardiogenic shock","volume":"367","author":"Thiele","year":"2012","journal-title":"N. Engl. J. Med."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1016\/j.jacc.2016.10.022","article-title":"Percutaneous mechanical circulatory support versus intra-aortic balloon pump in cardiogenic shock after acute myocardial infarction","volume":"69","author":"Ouweneel","year":"2017","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1173","DOI":"10.1002\/ccd.28307","article-title":"Improved outcomes associated with the use of shock protocols: Updates from the national cardiogenic shock initiative","volume":"93","author":"Basir","year":"2019","journal-title":"Catheter Cardiovasc. Interv."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Ameloot, K., Bastos, M.B., Daemen, J., Schreuder, J., Boersma, E., Zijlstra, F., and Van Mieghem, N.M. (2019). New generation mechanical circulatory support during high-risk PCI: A cross sectional analysis. EuroIntervention.","DOI":"10.4244\/EIJ-D-18-01126"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1890","DOI":"10.1016\/j.jacc.2019.01.055","article-title":"Percutaneous coronary intervention in older patients with ST-segment elevation myocardial infarction and cardiogenic shock","volume":"73","author":"Damluji","year":"2019","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1093\/eurheartj\/ehx393","article-title":"2017 ESC Guidelines for the management of acute myocardial infarction in patients presenting with ST-segment elevation","volume":"39","author":"Ibanez","year":"2018","journal-title":"Eur. Heart J."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"e7","DOI":"10.1016\/j.jacc.2015.03.036","article-title":"2015 SCAI\/ACC\/HFSA\/STS clinical expert consensus statement on the use of percutaneous mechanical circulatory support devices in cardiovascular care","volume":"65","author":"Rihal","year":"2015","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_12","first-page":"e574","article-title":"2011 ACCF\/AHA\/SCAI guideline for percutaneous coronary intervention","volume":"124","author":"Levine","year":"2011","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Wallace, T.W., Berger, J.S., Wang, A., Velazquez, E.J., and Brown, DL. (2009). Impact of left ventricular dysfunction on hospital mortality among patients undergoing elective percutaneous coronary intervention. Am. J. Cardiol.","DOI":"10.1016\/j.amjcard.2008.09.088"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1002\/ccd.23403","article-title":"Real-world use of the Impella 2.5 circulatory support system in complex high-risk percutaneous coronary intervention: The USpella registry","volume":"80","author":"Maini","year":"2012","journal-title":"Catheter Cardiovasc. Interv."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/S0002-9149(03)00655-6","article-title":"Evaluation of the American College of Cardiology\/American Heart Association and the Society for Coronary Angiography and Interventions lesion classification system in the current \u201cstent era\u201d of coronary interventions (from the ACC-National Cardiovascular","volume":"92","author":"Krone","year":"2003","journal-title":"Am. J. Cardiol."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Sakakura, K., Ako, J., Wada, H., Kubo, N., and Momomura, S.I. (2012). ACC\/AHA classification of coronary lesions reflects medical resource use in current percutaneous coronary interventions. Catheter Cardiovasc. Interv.","DOI":"10.1002\/ccd.23270"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"790","DOI":"10.1016\/j.jcin.2013.03.020","article-title":"Enhanced mortality risk prediction with a focus on high-risk percutaneous coronary intervention: Results from 1,208,137 procedures in the NCDR (national cardiovascular data registry)","volume":"6","author":"Brennan","year":"2013","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Burkhoff, D., Sayer, G., Doshi, D., and Uriel, N. (2015). Hemodynamics of mechanical circulatory support. J. Am. Coll. Cardiol.","DOI":"10.1016\/j.jacc.2015.10.017"},{"key":"ref_19","first-page":"e232","article-title":"Contemporary management of cardiogenic shock: A scientific statement from the american heart association","volume":"136","author":"Katz","year":"2017","journal-title":"Circulation"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Reynolds, H.R., and Hochman, J.S. (2008). Cardiogenic shock current concepts and improving outcomes. Circulation.","DOI":"10.1161\/CIRCULATIONAHA.106.613596"},{"key":"ref_21","unstructured":"Miller, L. (2016). Cardiogenic shock in acute myocardial infarction the era of mechanical support. J. Am. Coll. Cardiol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1427","DOI":"10.1016\/j.jacc.2016.12.005","article-title":"Trends in U.S. cardiovascular care: 2016 report from 4 ACC national cardiovascular data registries","volume":"69","author":"Masoudi","year":"2017","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Babaev, A., Frederick, P.D., Pasta, D.J., Every, N., Sichrovsky, T., and Hochman, J.S. (2005). Trends in management and outcomes of patients with acute myocardial infarction complicated by cardiogenic shock. J. Am. Med. Assoc.","DOI":"10.1001\/jama.294.4.448"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1016\/j.amjcard.2016.11.037","article-title":"Effect of early initiation of mechanical circulatory support on survival in cardiogenic shock","volume":"119","author":"Basir","year":"2017","journal-title":"Am. J. Cardiol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1498","DOI":"10.1016\/j.jacc.2008.12.058","article-title":"Acute left ventricular dynamic effects of primary percutaneous coronary intervention. From occlusion to reperfusion","volume":"53","author":"Remmelink","year":"2009","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Borlaug, B.A., and Kass, D.A. (2011). Invasive hemodynamic assessment in heart failure. Cardiol. Clin.","DOI":"10.1016\/j.ccl.2011.03.003"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Uriel, N., Sayer, G., Annamalai, S., Kapur, N.K., and Burkhoff, D. (2018). Mechanical unloading in heart failure. J. Am. Coll. Cardiol.","DOI":"10.1016\/j.jacc.2018.05.038"},{"key":"ref_28","unstructured":"Rab, T., and O\u2019Neill, W. (2018). Mechanical circulatory support for patients with cardiogenic shock. Trends Cardiovasc. Med."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Thiele, H., Ohman, E.M., Desch, S., Eitel, I., and De Waha, S. (2015). Management of cardiogenic shock. Eur. Heart J.","DOI":"10.1093\/eurheartj\/ehv051"},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Csepe, T.A., and Kilic, A. (2017). Advancements in mechanical circulatory support for patients in acute and chronic heart failure. J. Thorac. Dis.","DOI":"10.21037\/jtd.2017.09.89"},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Tan, L.B. (1986). Cardiac pumping capability and prognosis in heart failure. Lancet.","DOI":"10.1016\/S0140-6736(86)92006-4"},{"key":"ref_32","first-page":"33","article-title":"Peak cardiac power, measured non-invasively, is a powerful predictor of mortality in chronic heart failure","volume":"22","author":"Lang","year":"2007","journal-title":"Circulation"},{"key":"ref_33","unstructured":"WEBER, KT. (2013). Intra-aortic balloon pumping. Ann. Intern. Med."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Papaioannou, T.G., and Stefanadis, C. (2005). Basic principles of the intraaortic balloon pump and mechanisms affecting its performance. ASAIO J.","DOI":"10.1097\/01.MAT.0000159381.97773.9B"},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Rastan, A.J., Tillmann, E., Subramanian, S., Lehmkuhl, L., Funkat, A.K., Leontyev, S., Doenst, T., Walther, T., Gutberlet, M., and Mohr, F.W. (2010). Visceral arterial compromise during intra-aortic balloon counterpulsation therapy. Circulation.","DOI":"10.1161\/CIRCULATIONAHA.109.929810"},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Herrera-Perez, D., Haslam, A., Crain, T., Gill, J., Livingston, C., Kaestner, V., Hayes, M., Morgan, D., Cifu, A.S., and Prasad, V. (2019). A comprehensive review of randomized clinical trials in three medical journals reveals 396 medical reversals. Elife.","DOI":"10.7554\/eLife.45183.012"},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Basra, S.S., Loyalka, P., and Kar, B. (2011). Current status of percutaneous ventricular assist devices for cardiogenic shock. Curr. Opin. Cardiol.","DOI":"10.1097\/HCO.0b013e32834b803c"},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"M\u00f6bius-Winkler, S., Fritzenwanger, M., Pfeifer, R., and Schulze, P.C. (2018). Percutaneous support of the failing left and right ventricle\u2014Recommendations for the use of mechanical device therapy. Heart Fail. Rev.","DOI":"10.1007\/s10741-018-9730-z"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1161\/CIRCHEARTFAILURE.112.967224","article-title":"Percutaneous left-ventricular support with the impella-2.5-assist device in acute cardiogenic shock results of the impella-EUROSHOCK-registry","volume":"6","author":"Lauten","year":"2013","journal-title":"Circ. Hear Fail."},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Remmelink, M., Sjauw, K.D., Henriques, J.P., De Winter, R.J., Vis, M.M., Koch, K.T., Paulus, W.J., De Mol, B.A., Tijssen, J.G., and Piek, J.J. (2010). Effects of mechanical left ventricular unloading by impella on left ventricular dynamics in high-risk and primary percutaneous coronary intervention patients. Catheter Cardiovasc. Interv.","DOI":"10.1002\/ccd.22263"},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Doshi, R., Patel, K., Decter, D., Gupta, R., and Meraj, P. (2019). Trends in the utilisation and in-hospital mortality associated with short-term mechanical circulatory support for heart failure with reduced ejection fraction. Hear Lung Circ.","DOI":"10.1016\/j.hlc.2018.03.025"},{"key":"ref_42","first-page":"1201","article-title":"Percutaneous retrograde left ventricular assist support for patients with aortic stenosis and left ventricular dysfunction","volume":"80","author":"Martinez","year":"2011","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Kar, B., Gregoric, I.D., Basra, S.S., Idelchik, G.M., and Loyalka, P. (2010). The percutaneous ventricular assist device in severe refractory cardiogenic shock. J. Am. Coll. Cardiol.","DOI":"10.1016\/j.jacc.2010.08.613"},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Burkhoff, D., and Naidu, S.S. (2012). The science behind percutaneous hemodynamic support: A review and comparison of support strategies. Catheter Cardiovasc. Interv.","DOI":"10.1002\/ccd.24421"},{"key":"ref_45","doi-asserted-by":"crossref","unstructured":"Kono, S., Nishimura, K., Nishina, T., Komeda, M., and Akamatsu, T. (1999). Auto-synchronized systolic unloading during left ventricular assist with centrifugal pump. ASAIO J.","DOI":"10.1097\/00002480-199903000-00112"},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Pham, D.T., Al-Quthami, A., and Kapur, N.K. (2013). Percutaneous left ventricular support in cardiogenic shock and severe aortic regurgitation. Catheter Cardiovasc. Interv.","DOI":"10.1002\/ccd.24501"},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Ouweneel, D.M., Schotborgh, J.V., Limpens, J., Sjauw, K.D., Engstr\u00f6m, A.E., Lagrand, W.K., Cherpanath, T.G.V., Driessen, A.H.G., De Mol, B.A.J.M., and Henriques, J.P.S. (2016). Extracorporeal life support during cardiac arrest and cardiogenic shock: A systematic review and meta-analysis. Intensive Care Med.","DOI":"10.1007\/s00134-016-4536-8"},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Thiagarajan, R.R., Barbaro, R.P., Rycus, P.T., McMullan, D.M., Conrad, S.A., Fortenberry, J.D., and Paden, M.L. (2017). Extracorporeal life support organization registry international report 2016. ASAIO J.","DOI":"10.1097\/MAT.0000000000000475"},{"key":"ref_49","first-page":"75","article-title":"The fundamentals of extra-corporeal membrane oxygenation","volume":"63","author":"Aghili","year":"2015","journal-title":"Minerva Cardioangiol."},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"MacLaren, G., Combes, A., and Bartlett, R.H. (2012). Contemporary extracorporeal membrane oxygenation for adult respiratory failure: Life support in the new era. Intensive Care Med.","DOI":"10.1007\/s00134-011-2439-2"},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Russo, J.J., Aleksova, N., Pitcher, I., Couture, E., Parlow, S., Faraz, M., Visintini, S., Simard, T., Di Santo, P., and Mathew, R. (2019). Left ventricular unloading during extracorporeal membrane oxygenation in patients with cardiogenic shock. J. Am. Coll. Cardiol.","DOI":"10.1016\/j.jacc.2018.10.085"},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Koeckert, M.S., Jorde, U.P., Naka, Y., Moses, J.W., and Takayama, H. (2011). Impella LP 2.5 for left ventricular unloading during venoarterial extracorporeal membrane oxygenation support. J. Cardiol. Surg.","DOI":"10.1111\/j.1540-8191.2011.01338.x"},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Ostadal, P., Mlcek, M., Gorhan, H., Simundic, I., Strunina, S., Hrachovina, M., Kr\u00fcger, A., Vondrakova, D., Janotka, M., and Hala, P. (2018). Electrocardiogram-synchronized pulsatile extracorporeal life support preserves left ventricular function and coronary flow in a porcine model of cardiogenic shock. PLoS ONE.","DOI":"10.1371\/journal.pone.0196321"},{"key":"ref_54","doi-asserted-by":"crossref","unstructured":"Wang, S., Izer, J.M., Clark, J.B., Patel, S., Pauliks, L., Kunselman, A.R., Leach, D., Cooper, T.K., Wilson, R.P., and \u00dcndar, A. (2015). In vivo hemodynamic performance evaluation of novel electrocardiogram-synchronized pulsatile and nonpulsatile extracorporeal life support systems in an adult swine model. Artif. Organs.","DOI":"10.1111\/aor.12482"},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Wolfe, R., Strother, A., Wang, S., Kunselman, A.R., and \u00dcndar, A. (2015). Impact of pulsatility and flow rates on hemodynamic energy transmission in an adult extracorporeal life support system. Artif. Organs.","DOI":"10.1111\/aor.12484"},{"key":"ref_56","doi-asserted-by":"crossref","unstructured":"P\u00f6ss, J., Kriechbaum, S., Ewen, S., Graf, J., Hager, I., Hennersdorf, M., Petros, S., Link, A., Bohm, M., and Thiele, H. (2015). First-in-man analysis of the i-cor assist device in patients with cardiogenic shock. Eur. Heart J. Acute Cardiovasc. Care.","DOI":"10.1177\/2048872614561481"},{"key":"ref_57","doi-asserted-by":"crossref","unstructured":"Masyuk, M., Abel, P., Hug, M., Wernly, B., Haneya, A., Sack, S., Sideris, K., Langwieser, N., Graf, T., and Fuernau, G. (2019). Real-world clinical experience with the percutaneous extracorporeal life support system: Results from the German Lifebridge\u00ae Registry. Clin. Res. Cardiol.","DOI":"10.1007\/s00392-019-01482-2"},{"key":"ref_58","doi-asserted-by":"crossref","unstructured":"Cheng, R., Hachamovitch, R., Kittleson, M., Patel, J., Arabia, F., Moriguchi, J., Esmailian, F., and Azarbal, B. (2014). Complications of extracorporeal membrane oxygenation for treatment of cardiogenic shock and cardiac arrest: A meta-analysis of 1,866 adult patients. Ann. Thorac. Surg.","DOI":"10.1016\/j.athoracsur.2013.09.008"},{"key":"ref_59","unstructured":"Uil, C.D., Daemen, J., Lenzen, M., Maugenest, A.-M., Joziasse, L., Van Geuns, R., and Van Mieghem, N. (2017). Pulsatile iVAC 2L circulatory support in high-risk percutaneous coronary intervention. EuroIntervention."},{"key":"ref_60","doi-asserted-by":"crossref","unstructured":"McLaughlin, V.V., Archer, S.L., Badesch, D.B., Barst, R.J., Farber, H.W., Lindner, J.R., Mathier, M.A., McGoon, M.D., Park, M.H., and Rosenson, R.S. (2009). ACCF\/AHA 2009 expert consensus document on pulmonary hypertension. A report of the American College of Cardiology Foundation task force on expert consensus documents and the American Heart Association Developed in Collaboration with the American College of Chest Physicians; American Thoracic Society, Inc.; and the Pulmonary Hypertension Association. J. Am. Coll. Cardiol.","DOI":"10.1016\/j.jacc.2009.01.004"},{"key":"ref_61","doi-asserted-by":"crossref","unstructured":"Anderson, M.B., Goldstein, J., Milano, C., Morris, L.D., Kormos, R.L., Bhama, J., Kapur, N.K., Bansal, A., Garcia, J., and Baker, J.N. (2015). Benefits of a novel percutaneous ventricular assist device for right heart failure: The prospective RECOVER RIGHT study of the Impella RP device. J. Heart Lung Transplant.","DOI":"10.1016\/j.healun.2015.08.018"},{"key":"ref_62","doi-asserted-by":"crossref","unstructured":"Harris, S., Tepper, D., and Ip, R. (2010). Comparison of hospital mortality with intra-aortic balloon counterpulsation insertion before vs after primary percutaneous coronary intervention for cardiogenic shock complicating acute myocardial infarction. Congest. Heart Fail.","DOI":"10.1111\/j.1751-7133.2010.00174.x"},{"key":"ref_63","doi-asserted-by":"crossref","unstructured":"Sjauw, K.D., Engstr\u00f6m, A.E., Vis, M.M., van der Schaaf, R.J., Baan, J., Koch, K.T., de Winter, R.J., Piek, J.J., Tijssen, J.G., and Henriques, J.P. (2009). A systematic review and meta-analysis of intra-aortic balloon pump therapy in ST-elevation myocardial infarction: Should we change the guidelines?. Eur. Heart J.","DOI":"10.1093\/eurheartj\/ehn602"},{"key":"ref_64","doi-asserted-by":"crossref","unstructured":"Hochman, J.S., Sleeper, L.A., Webb, J.G., Sanborn, T.A., White, H.D., Talley, J.D., Buller, C.E., Jacobs, A.K., Slater, J.N., and Col, J. (1999). Early revascularization in acute myocardial infarction complicated by cardiogenic shock. SHOCK Investigators. Should we emergently revascularize occluded coronaries for cardiogenic shock. N. Engl. J. Med.","DOI":"10.1056\/NEJM199908263410901"},{"key":"ref_65","doi-asserted-by":"crossref","unstructured":"Thiele, H., Zeymer, U., Neumann, F.-J., Ferenc, M., Olbrich, H.-G., Hausleiter, J., De Waha, A., Richardt, G., Hennersdorf, M., and Empen, K. (2013). Intra-aortic balloon counterpulsation in acute myocardial infarction complicated by cardiogenic shock (IABP-SHOCK II): Final 12 month results of a randomised, open-label trial. Lancet.","DOI":"10.1016\/S0140-6736(13)61783-3"},{"key":"ref_66","doi-asserted-by":"crossref","unstructured":"Thiele, H., Zeymer, U., Thelemann, N., Neumann, F.J., Hausleiter, J., Abdel-Wahab, M., Meyer-Saraei, R., Fuernau, G., Eitel, I., and Hambrecht, R. (2018). Intraaortic balloon pump in cardiogenic shock complicating acute myocardial infarction: Long-term 6-year outcome of the randomized IABP-SHOCK II trial. Circulation.","DOI":"10.1161\/CIRCULATIONAHA.118.038201"},{"key":"ref_67","doi-asserted-by":"crossref","unstructured":"Dehmer, G.J., Blankenship, J.C., Cilingiroglu, M., Dwyer, J.G., Feldman, D.N., Gardner, T.J., Grines, C.L., and Singh, M. (2014). SCAI\/ACC\/AHA Expert consensus document: 2014 update on percutaneous coronary intervention without on-site surgical backup. Catheter Cardiovasc. Interv.","DOI":"10.1161\/CIR.0000000000000037"},{"key":"ref_68","doi-asserted-by":"crossref","unstructured":"Patel, M.R., Smalling, R.W., Thiele, H., Barnhart, H.X., Zhou, Y., Chandra, P., Chew, D., Choen, M., French, J., and Perera, D. (2011). Intra-aortic balloon counterpulsation and infarct size in patients with acute anterior myocardial infarction without shock: The CRISP AMI randomized trial. JAMA-J. Am. Med. Assoc.","DOI":"10.1001\/jama.2011.1280"},{"key":"ref_69","doi-asserted-by":"crossref","unstructured":"Curtis, J.P., Rathore, S.S., Wang, Y., Chen, J., Nallamothu, B.K., and Krumholz, H.M. (2012). Use and effectiveness of intra-Aortic balloon pumps among patients undergoing high risk percutaneous coronary intervention: Insights from the national cardiovascular data registry. Circ. Cardiovasc. Qual. Outcomes.","DOI":"10.1161\/CIRCOUTCOMES.110.960385"},{"key":"ref_70","doi-asserted-by":"crossref","unstructured":"Perera, D., Stables, R., Clayton, T., De Silva, K., Lumley, M., Clack, L., Thomas, M., Redwood, S., and BCSI-1 Investigators (2012). Long-term mortality data from the balloon pump\u2013assisted coronary intervention study (BCIS-1). Circulation.","DOI":"10.1161\/CIRCULATIONAHA.112.132209"},{"key":"ref_71","doi-asserted-by":"crossref","unstructured":"O\u2019Gara, P.T., Kushner, F.G., Ascheim, D.D., E Casey, D., Chung, M.K., A De Lemos, J., Ettinger, S.M., Fang, J.C., Fesmire, F.M., and A Franklin, B. (2013). 2013 ACCF\/AHA guideline for the management of st-elevation myocardial infarction: Executive summary: A report of the American college of cardiology foundation\/american heart association task force on practice guidelines. J. Am. Coll. Cardiol.","DOI":"10.1161\/CIR.0b013e3182742c84"},{"key":"ref_72","doi-asserted-by":"crossref","unstructured":"Seyfarth, M., Sibbing, D., Bauer, I., Fr\u00f6hlich, G., Bott-Fl\u00fcgel, L., Byrne, R., Dirschinger, J., Kastrati, A., and Sch\u00f6mig, A. (2008). A Randomized clinical trial to evaluate the safety and efficacy of a percutaneous left ventricular assist device versus intra-aortic balloon pumping for treatment of cardiogenic shock caused by myocardial infarction. J. Am. Coll. Cardiol.","DOI":"10.1016\/j.jacc.2008.05.065"},{"key":"ref_73","doi-asserted-by":"crossref","unstructured":"Zeymer, U., and Thiele, H. (2017). Mechanical support for cardiogenic shock: Lost in translation?. J. Am. Coll. Cardiol.","DOI":"10.1016\/j.jacc.2016.10.025"},{"key":"ref_74","doi-asserted-by":"crossref","unstructured":"Karatolios, K., Chatzis, G., Markus, B., Luesebrink, U., Ahrens, H., Dersch, W., Betz, S., Ploeger, B., Boesl, E., and O\u2019Neill, W. (2018). Impella support compared to medical treatment for post-cardiac arrest shock after out of hospital cardiac arrest. Resuscitation.","DOI":"10.1016\/j.resuscitation.2018.03.008"},{"key":"ref_75","doi-asserted-by":"crossref","unstructured":"Schrage, B., Ibrahim, K., Loehn, T., Werner, N., Sinning, J.-M., Pappalardo, F., Pieri, M., Skurk, C., Lauten, A., and Landmesser, U. (2019). Impella support for acute myocardial infarction complicated by cardiogenic shock. Circulation.","DOI":"10.1161\/CIRCULATIONAHA.118.036614"},{"key":"ref_76","doi-asserted-by":"crossref","unstructured":"Wernly, B., Seelmaier, C., Leistner, D., St\u00e4hli, B.E., Pretsch, I., Lichtenauer, M., Jung, C., Hoppe, U.C., Landmesser, U., and Thiele, H. (2019). Mechanical circulatory support with Impella versus intra-aortic balloon pump or medical treatment in cardiogenic shock\u2014A critical appraisal of current data. Clin. Res. Cardiol.","DOI":"10.1007\/s00392-019-01458-2"},{"key":"ref_77","doi-asserted-by":"crossref","unstructured":"Henriques, J.P., Remmelink, M., Baan, J., Van Der Schaaf, R.J., Vis, M.M., Koch, K.T., Scholten, E.W., De Mol, B.A., Tijssen, J.G., and Piek, J.J. (2006). Safety and feasibility of elective high-risk percutaneous coronary intervention procedures with left ventricular support of the impella recover LP 2.5. Am. J. Cardiol.","DOI":"10.1016\/j.amjcard.2005.10.037"},{"key":"ref_78","doi-asserted-by":"crossref","unstructured":"Dixon, S.R., Henriques, J.P., Mauri, L., Sjauw, K., Civitello, A., Kar, B., Loyalka, P., Resnic, F.S., Teirstein, P., and Makkar, R. (2009). A prospective feasibility trial investigating the use of the impella 2.5 system in patients undergoing high-risk percutaneous coronary intervention (The PROTECT I Trial). Initial U.S. Experience. JACC Cardiovasc. Interv.","DOI":"10.1016\/j.jcin.2008.11.005"},{"key":"ref_79","doi-asserted-by":"crossref","unstructured":"Dangas, G.D., Kini, A.S., Sharma, S.K., Henriques, J.P., Claessen, B.E., Dixon, S.R., Massaro, J.M., Palacios, I., Popma, J.J., and Ohman, E.M. (2014). Impact of hemodynamic support with impella 2.5 versus intra-aortic balloon pump on prognostically important clinical outcomes in patients undergoing high-risk percutaneous coronary intervention (from the PROTECT II randomized trial). Am. J. Cardiol.","DOI":"10.1016\/j.amjcard.2013.09.008"},{"key":"ref_80","doi-asserted-by":"crossref","unstructured":"Thiele, H., Sick, P., Boudriot, E., Diederich, K.-W., Hambrecht, R., Niebauer, J., and Schuler, G. (2005). Randomized comparison of intra-aortic balloon support with a percutaneous left ventricular assist device in patients with revascularized acute myocardial infarction complicated by cardiogenic shock. Eur. Heart J.","DOI":"10.1093\/eurheartj\/ehi161"},{"key":"ref_81","doi-asserted-by":"crossref","unstructured":"Burkhoff, D., Cohen, H., Brunckhorst, C., and O\u2019Neill, W.W. (2006). A randomized multicenter clinical study to evaluate the safety and efficacy of the TandemHeart percutaneous ventricular assist device versus conventional therapy with intraaortic balloon pumping for treatment of cardiogenic shock. Am. Heart J.","DOI":"10.1016\/j.ahj.2006.05.031"},{"key":"ref_82","doi-asserted-by":"crossref","unstructured":"Alli, O.O., Singh, I.M., Holmes, D.R., Pulido, J.N., Park, S.J., and Rihal, C.S. (2012). Percutaneous left ventricular assist device with TandemHeart for high-risk percutaneous coronary intervention: The Mayo Clinic experience. Catheter Cardiovasc. Interv.","DOI":"10.1002\/ccd.23465"},{"key":"ref_83","doi-asserted-by":"crossref","unstructured":"Briasoulis, A., Telila, T., Palla, M., Mercado, N., Kondur, A., Grines, C., and Schreiber, T. (2016). Meta-analysis of usefulness of percutaneous left ventricular assist devices for high-risk percutaneous coronary interventions. Am. J. Cardiol.","DOI":"10.1016\/j.amjcard.2016.05.003"},{"key":"ref_84","unstructured":"Bermudez, C., Kormos, R., Subramaniam, K., Mulukutla, S., Sappington, P., Waters, J., Khandhar, S.J., Esper, S.A., and Dueweke, E.J. (2015). Extracorporeal Membrane oxygenation support in acute coronary syndromes complicated by cardiogenic shock. Catheter Cardiovasc. Interv."},{"key":"ref_85","first-page":"52","article-title":"Contemporary use of veno-arterial extracorporeal membrane oxygenation for refractory cardiogenic shock in acute coronary syndrome","volume":"28","author":"Negi","year":"2016","journal-title":"J. Invasive Cardiol."},{"key":"ref_86","doi-asserted-by":"crossref","unstructured":"Chen, Y.-S., Chao, A., Yu, H.-Y., Ko, W.-J., Wu, I.-H., Chen, R.J.-C., Huang, S.-C., Lin, F.-Y., and Wang, S.-S. (2003). Analysis and results of prolonged resuscitation in cardiac arrest patients rescued by extracorporeal membrane oxygenation. J. Am. Coll. Cardiol.","DOI":"10.1016\/S0735-1097(02)02716-X"},{"key":"ref_87","doi-asserted-by":"crossref","unstructured":"Schrage, B., Burkhoff, D., R\u00fcbsamen, N., Becher, P.M., Schwarzl, M., Bernhardt, A., Grahn, H., Lubos, E., S\u00f6ffker, G., and Clemmensen, P. (2018). Unloading of the left ventricle during venoarterial extracorporeal membrane oxygenation therapy in cardiogenic shock. JACC Heart Fail.","DOI":"10.1016\/j.healun.2018.01.047"},{"key":"ref_88","doi-asserted-by":"crossref","unstructured":"Myat, A., Patel, N., Tehrani, S., Banning, A.P., Redwood, S.R., and Bhatt, D.L. (2015). Percutaneous circulatory assist devices for high-risk coronary intervention. JACC Cardiovasc. Interv.","DOI":"10.1016\/j.jcin.2014.07.030"},{"key":"ref_89","doi-asserted-by":"crossref","unstructured":"Maini, B., Gregory, D., Scotti, D.J., and Buyantseva, L. (2014). Percutaneous cardiac assist devices compared with surgical hemodynamic support alternatives: Cost-effectiveness in the emergent setting. Catheter Cardiovasc. Interv.","DOI":"10.1002\/ccd.25247"},{"key":"ref_90","doi-asserted-by":"crossref","unstructured":"Roos, J.B., Doshi, S.N., Konorza, T., Palacios, I., Schreiber, T., Borisenko, O.V., and Henriques, J.P.S. (2013). The cost-effectiveness of a new percutaneous ventricular assist device for high-risk PCI patients: mid-stage evaluation from the European perspective. J. Med. Econ.","DOI":"10.3111\/13696998.2012.762004"},{"key":"ref_91","doi-asserted-by":"crossref","unstructured":"Udesen, N.J., M\u00f8ller, J.E., Lindholm, M.G., Eiskj\u00e6r, H., Sch\u00e4fer, A., Werner, N., Holmvang, L., Terkelsen, C.J., Jensen, L.O., and Junker, A. (2019). Rationale and design of DanGer shock: Danish-German cardiogenic shock trial. Am. Heart J.","DOI":"10.1016\/j.ahj.2019.04.019"},{"key":"ref_92","doi-asserted-by":"crossref","unstructured":"Jung, C., Bueter, S., Wernly, B., Masyuk, M., Saeed, D., Albert, A., Fuernau, G., Kelm, M., and Westenfeld, R. (2019). Lactate clearance predicts good neurological outcomes in cardiac arrest patients treated with extracorporeal cardiopulmonary resuscitation. J. Clin. Med.","DOI":"10.3390\/jcm8030374"},{"key":"ref_93","doi-asserted-by":"crossref","unstructured":"Slottosch, I., Liakopoulos, O., Kuhn, E., Scherner, M., Deppe, A.-C., Sabashnikov, A., Mader, N., Choi, Y.-H., Wippermann, J., and Wahlers, T. (2017). Lactate and lactate clearance as valuable tool to evaluate ECMO therapy in cardiogenic shock. J. Crit. Care.","DOI":"10.1016\/j.jcrc.2017.06.022"},{"key":"ref_94","doi-asserted-by":"crossref","unstructured":"Fux, T., Holm, M., Corbascio, M., and van der Linden, J. (2019). cardiac arrest prior to venoarterial extracorporeal membrane oxygenation. Crit. Care Med.","DOI":"10.1097\/CCM.0000000000003772"},{"key":"ref_95","doi-asserted-by":"crossref","unstructured":"Lee, W.-C., Fang, C.-Y., Chen, H.-C., Chen, C.-J., Yang, C.-H., Hang, C.-L., Yip, H.-K., Fang, H.-Y., and Wu, C.-J. (2016). Associations with 30-day survival following extracorporeal membrane oxygenation in patients with acute ST segment elevation myocardial infarction and profound cardiogenic shock. Heart Lung J. Acute Crit. Care.","DOI":"10.1016\/j.hrtlng.2016.08.006"},{"key":"ref_96","doi-asserted-by":"crossref","unstructured":"Kapur, N.K., Paruchuri, V., Urbano-Morales, J.A., Mackey, E.E., Daly, G.H., Qiao, X., Pandian, N., Perides, G., and Karas, R.H. (2013). Mechanically unloading the left ventricle before coronary reperfusion reduces left ventricular wall stress and myocardial infarct size. Circulation.","DOI":"10.1161\/CIRCULATIONAHA.112.000029"},{"key":"ref_97","doi-asserted-by":"crossref","unstructured":"Esposito, M.L., Zhang, Y., Qiao, X., Reyelt, L., Paruchuri, V., Schnitzler, G.R., Morine, K.J., Annamalai, S.K., Bogins, C., and Natov, P.S. (2018). Left ventricular unloading before reperfusion promotes functional recovery after acute myocardial infarction. J. Am. Coll. Cardiol.","DOI":"10.1016\/j.jacc.2018.05.034"},{"key":"ref_98","doi-asserted-by":"crossref","first-page":"1087","DOI":"10.1016\/S0735-1097(03)00084-6","article-title":"Left ventricular support by catheter-mounted axial flow pump reduces infarct size","volume":"41","author":"Meyns","year":"2003","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_99","doi-asserted-by":"crossref","unstructured":"Kapur, N.K., Qiao, X., Paruchuri, V., Morine, K.J., Syed, W., Dow, S., Shah, N., Pandian, N., and Karas, R.H. (2015). Mechanical pre-conditioning with acute circulatory support before reperfusion limits infarct size in acute myocardial infarction. JACC Heart Fail.","DOI":"10.1016\/j.jchf.2015.06.010"},{"key":"ref_100","doi-asserted-by":"crossref","unstructured":"Kapur, N.K., Alkhouli, M.A., DeMartini, T.J., Faraz, H., George, Z.H., Goodwin, M.J., Hernandez-Montfort, J.A., Iyer, V.S., Josephy, N., and Kalra, S. (2019). Unloading the left ventricle before reperfusion in patients with anterior st-segment-elevation myocardial infarction: A pilot study using the impella CP. Circulation.","DOI":"10.1161\/CIRCULATIONAHA.118.038269"},{"key":"ref_101","doi-asserted-by":"crossref","unstructured":"O\u2019Neill, W.W., Grines, C., Schreiber, T., Moses, J., Maini, B., Dixon, S.R., Ohman, E.M., and O\u2019Neill, W.W. (2018). Analysis of outcomes for 15,259 US patients with acute myocardial infarction cardiogenic shock (AMICS) supported with the Impella device. Am. Heart J.","DOI":"10.1016\/j.ahj.2018.03.024"},{"key":"ref_102","doi-asserted-by":"crossref","unstructured":"Flaherty, M.P., Khan, A.R., and O\u2019Neill, W.W. (2017). Early initiation of impella in acute myocardial infarction complicated by cardiogenic shock improves survival: A meta-analysis. JACC Cardiovasc. Interv.","DOI":"10.1016\/j.jcin.2017.06.027"},{"key":"ref_103","doi-asserted-by":"crossref","unstructured":"Auffret, V., Cottin, Y., Leurent, G., Gilard, M., Beer, J.-C., Zabalawi, A., Chagu\u00e9, F., Filippi, E., Brunet, D., and Hacot, J.-P. (2018). Predicting the development of in-hospital cardiogenic shock in patients with ST-segment elevation myocardial infarction treated by primary percutaneous coronary intervention: The ORBI risk score. Eur. Heart J.","DOI":"10.1093\/eurheartj\/ehy565.P2482"},{"key":"ref_104","doi-asserted-by":"crossref","unstructured":"Schrage, B., and Westermann, D. (2019). Reply: Does VA-ECMO plus impella work in refractory cardiogenic shock?. JACC Heatr Fail.","DOI":"10.1016\/j.jchf.2019.01.001"},{"key":"ref_105","doi-asserted-by":"crossref","unstructured":"Li, Y., Yan, S., Gao, S., Liu, M., Lou, S., Liu, G., Ji, B., and Gao, B. (2019). Effect of an intra-aortic balloon pump with venoarterial extracorporeal membrane oxygenation on mortality of patients with cardiogenic shock: A systematic review and meta-analysis. Eur. J. Cardio-Thoracic Surg.","DOI":"10.1093\/ejcts\/ezy304"},{"key":"ref_106","unstructured":"Ohman, E.M., Nanas, J., Stomel, R.J., Leesar, M.A., Nielsen, D.W.T., O\u2019Dea, D., Rogers, F.J., Harber, D., Hudson, M.P., and Fraulo, E. (2005). Thrombolysis and counterpulsation to improve survival in myocardial infarction complicated by hypotension and suspected cardiogenic shock or heart failure: Results of the TACTICS trial. J. Thromb. Thrombolysis."},{"key":"ref_107","doi-asserted-by":"crossref","unstructured":"Waksman, R., Weiss, A.T., Gotsman, M.S., and Hasin, Y. (1993). Intra-aortic balloon counterpulsation improves survival in cardiogenic shock complicating acute myocardial infarction. Eur. Heart J.","DOI":"10.1093\/eurheartj\/14.1.71"},{"key":"ref_108","doi-asserted-by":"crossref","unstructured":"Barron, H.V., Every, N.R., Parsons, L.S., Angeja, B., Goldberg, R.J., Gore, J.M., and Chou, T.M. (2001). The use of intra-aortic balloon counterpulsation in patients with cardiogenic shock complicating acute myocardial infarction: Data from the national registry of myocardial infarction 2. Am. Heart J.","DOI":"10.1067\/mhj.2001.115295"},{"key":"ref_109","doi-asserted-by":"crossref","unstructured":"Cheng, J.M., Uil, C.A.D., Hoeks, S.E., Van Der Ent, M., Jewbali, L.S., Van Domburg, R.T., and Serruys, P.W. (2009). Percutaneous left ventricular assist devices vs. intra-aortic balloon pump counterpulsation for treatment of cardiogenic shock: A meta-analysis of controlled trials. Eur. Heart J.","DOI":"10.1093\/eurheartj\/ehp292"},{"key":"ref_110","doi-asserted-by":"crossref","unstructured":"Alushi, B., Douedari, A., Froehlich, G., Knie, W., Leistner, D., Staehli, B., Mochmann, H.-C., Pieske, B., Landmesser, U., and Krackhardt, F. (2018). P2481Impella assist device or intraaortic balloon pump for treatment of cardiogenic shock due to acute coronary syndrome. Eur. Heart J.","DOI":"10.1093\/eurheartj\/ehy565.P2481"},{"key":"ref_111","doi-asserted-by":"crossref","unstructured":"Nichol, G., Karmy-Jones, R., Salerno, C., Cantore, L., and Becker, L. (2006). Systematic review of percutaneous cardiopulmonary bypass for cardiac arrest or cardiogenic shock states. Resuscitation.","DOI":"10.1016\/j.resuscitation.2006.01.018"},{"key":"ref_112","doi-asserted-by":"crossref","unstructured":"Sheu, J.-J., Tsai, T.-H., Lee, F.-Y., Fang, H.-Y., Sun, C.-K., Leu, S., Yang, C.-H., Chen, S.-M., Hang, C.-L., and Hsieh, Y.-K. (2010). Early extracorporeal membrane oxygenator-assisted primary percutaneous coronary intervention improved 30-day clinical outcomes in patients with ST-segment elevation myocardial infarction complicated with profound cardiogenic shock. Crit. Care Med.","DOI":"10.1097\/CCM.0b013e3181e8acf7"},{"key":"ref_113","doi-asserted-by":"crossref","unstructured":"Takayama, H., Truby, L., Koekort, M., Uriel, N., Colombo, P., Mancini, D.M., Jorde, U.P., and Naka, Y. (2013). Clinical outcome of mechanical circulatory support for refractory cardiogenic shock in the current era. J. Heart Lung Transplant.","DOI":"10.1016\/j.healun.2012.10.005"},{"key":"ref_114","doi-asserted-by":"crossref","unstructured":"Teirstein, P.S., Vogel, R.A., Dorros, G., Stertzer, S.H., Vandormael, M., Smith, S.C., Overlie, P.A., and O\u2019Neill, W.W. (1993). Prophylactic versus standby cardiopulmonary support for high risk percutaneous transluminal coronary angioplasty. J. Am. Coll. Cardiol.","DOI":"10.1016\/0735-1097(93)90089-J"},{"key":"ref_115","doi-asserted-by":"crossref","unstructured":"Schreiber, T.L., Kodali, U.R., O\u2019Neill, W.W., Gangadharan, V., Puchrowicz-Ochocki, S.B., and Grines, C.L. (1998). Comparison of acute results of prophylactic intraaortic balloon pumping with cardiopulmonary support for percutaneous transluminal coronary angioplasty (PTCA). Catheter Cardiovasc. Diagn.","DOI":"10.1002\/(SICI)1097-0304(199810)45:2<115::AID-CCD3>3.0.CO;2-F"}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/8\/8\/1209\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:10:51Z","timestamp":1760188251000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/8\/8\/1209"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8,13]]},"references-count":115,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2019,8]]}},"alternative-id":["jcm8081209"],"URL":"https:\/\/doi.org\/10.3390\/jcm8081209","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,8,13]]}}}