{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T05:14:19Z","timestamp":1791350059109,"version":"4.3.1"},"reference-count":38,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2020,3,7]],"date-time":"2020-03-07T00:00:00Z","timestamp":1583539200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Canada Research Chair","award":["CRC"],"award-info":[{"award-number":["CRC"]}]},{"DOI":"10.13039\/501100000038","name":"Natural Sciences and Engineering Research Council of Canada","doi-asserted-by":"publisher","award":["RGPIN-2014-04462"],"award-info":[{"award-number":["RGPIN-2014-04462"]}],"id":[{"id":"10.13039\/501100000038","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>One in three adults worldwide has hypertension, which is associated with significant morbidity and mortality. Consequently, there is a global demand for continuous and non-invasive blood pressure (BP) measurements that are convenient, easy to use, and more accurate than the currently available methods for detecting hypertension. This could easily be achieved through the integration of single-site photoplethysmography (PPG) readings into wearable devices, although improved reliability and an understanding of BP estimation accuracy are essential. This review paper focuses on understanding the features of PPG associated with BP and examines the development of this technology over the 2010\u20132019 period in terms of validation, sample size, diversity of subjects, and datasets used. Challenges and opportunities to move single-site PPG forward are also discussed.<\/jats:p>","DOI":"10.3390\/jcm9030723","type":"journal-article","created":{"date-parts":[[2020,3,9]],"date-time":"2020-03-09T05:37:34Z","timestamp":1583732254000},"page":"723","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":120,"title":["Cuffless Single-Site Photoplethysmography for Blood Pressure Monitoring"],"prefix":"10.3390","volume":"9","author":[{"given":"Manish","family":"Hosanee","sequence":"first","affiliation":[{"name":"Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 1Z3, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gabriel","family":"Chan","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 1Z3, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaylie","family":"Welykholowa","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 1Z3, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7053-4305","authenticated-orcid":false,"given":"Rachel","family":"Cooper","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 1Z3, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2868-485X","authenticated-orcid":false,"given":"Panayiotis A.","family":"Kyriacou","sequence":"additional","affiliation":[{"name":"Research Centre for Biomedical Engineering, City, University of London, London EC1V 0HB, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dingchang","family":"Zheng","sequence":"additional","affiliation":[{"name":"Research Center of Intelligent Healthcare, Faculty of Health and Life Science, Coventry University, Coventry CV1 5FB, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7263-0533","authenticated-orcid":false,"given":"John","family":"Allen","sequence":"additional","affiliation":[{"name":"Northern Medical Physics and Clinical Engineering, Freeman Hospital, Newcastle upon Tyne NE7 7DN, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0945-2674","authenticated-orcid":false,"given":"Derek","family":"Abbott","sequence":"additional","affiliation":[{"name":"School of Electrical and Electronic Engineering, The University of Adelaide, Adelaide, SA 5005, Australia"},{"name":"Centre for Biomedical Engineering, The University of Adelaide, Adelaide, SA 5005, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2309-9977","authenticated-orcid":false,"given":"Carlo","family":"Menon","sequence":"additional","affiliation":[{"name":"School of Mechatronic Systems Engineering, Simon Fraser University, Burnaby, BC V5A 1S6, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1637-1079","authenticated-orcid":false,"given":"Nigel H.","family":"Lovell","sequence":"additional","affiliation":[{"name":"Graduate School of Biomedical Engineering, UNSW Sydney, Sydney, NSW 2052, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8503-3973","authenticated-orcid":false,"given":"Newton","family":"Howard","sequence":"additional","affiliation":[{"name":"Nuffield Department of Surgical Sciences, University of Oxford, Oxford OX3 9DU, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wee-Shian","family":"Chan","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 1Z3, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenneth","family":"Lim","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 1Z3, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8470-8417","authenticated-orcid":false,"given":"Richard","family":"Fletcher","sequence":"additional","affiliation":[{"name":"D-Lab, Massachusetts Institute of Technology, Cambridge, MA 02139, USA"},{"name":"Department of Psychiatry, University of Massachusetts Medical School, Worcester, MA 01655, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2471-1902","authenticated-orcid":false,"given":"Rabab","family":"Ward","sequence":"additional","affiliation":[{"name":"School of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1831-0202","authenticated-orcid":false,"given":"Mohamed","family":"Elgendi","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 1Z3, Canada"},{"name":"School of Mechatronic Systems Engineering, Simon Fraser University, Burnaby, BC V5A 1S6, Canada"},{"name":"School of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada"},{"name":"BC Children\u2019s &amp; Women\u2019s Hospital, Vancouver, BC V6H 3N1, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2020,3,7]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1016\/S0140-6736(05)17741-1","article-title":"Global burden of hypertension: Analysis of worldwide data","volume":"365","author":"Kearney","year":"2005","journal-title":"Lancet"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"R1","DOI":"10.1088\/0967-3334\/36\/3\/R1","article-title":"A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time","volume":"36","author":"Buxi","year":"2015","journal-title":"Physiol. Meas."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1016\/j.jpedsurg.2017.11.013","article-title":"Noninvasive monitoring of physiologic compromise in acute appendicitis: New insight into an old disease","volume":"53","author":"Choi","year":"2018","journal-title":"J. Pediatric Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1455","DOI":"10.1109\/JBHI.2016.2620995","article-title":"Continuous blood pressure measurement from invasive to unobtrusive: Celebration of 200th birth anniversary of Carl Ludwig","volume":"20","author":"Ding","year":"2016","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"180076","DOI":"10.1038\/sdata.2018.76","article-title":"An optimal filter for short photoplethysmogram signals","volume":"5","author":"Liang","year":"2018","journal-title":"Sci. Data"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/s41746-019-0136-7","article-title":"The use of photoplethysmography for assessing hypertension","volume":"2","author":"Elgendi","year":"2019","journal-title":"Npj Digit. Med."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Chan, G., Cooper, R., Hosanee, M., Welykholowa, K., Kyriacou, P.A., Zheng, D., Allen, J., Abbott, D., Lovell, N.H., and Fletcher, R. (2019). Multi-Site Photoplethysmography Technology for Blood Pressure Assessment: Challenges and Recommendations. J. Clin. Med., 8.","DOI":"10.3390\/jcm8111827"},{"key":"ref_8","unstructured":"Albert, R., Vogt, W., and Helbig, W. (1973). Photoelectric measurement of blood pressure and flow in the finger. The Digest of 10th Inernational Conference of Medical Biological Engineering, Dresden, GDR, Germany, 13\u201317 August, 1973, The Conference Committee."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1164","DOI":"10.1161\/HYPERTENSIONAHA.117.10647","article-title":"Performance of a blood pressure smartphone app in pregnant women: The iPARR Trial (iPhone app compared with standard RR measurement)","volume":"71","author":"Raichle","year":"2018","journal-title":"Hypertension"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1007\/s10916-018-0901-1","article-title":"Assessment of subtle changes in diabetes-associated arteriosclerosis using photoplethysmographic pulse wave from index finger","volume":"42","author":"Hsu","year":"2018","journal-title":"J. Med Syst."},{"key":"ref_11","unstructured":"Alex, R.M., Zhang, R., Watenpaugh, D.E., and Behbehani, K. (2018, January 18\u201321). Mathematical Modeling of Arterial Blood Pressure Using Photo-Plethysmography Signal in Breath-hold Maneuver. Proceedings of the 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Honolulu, HI, USA."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1016\/j.compbiomed.2018.09.013","article-title":"Arterial blood pressure feature estimation using photoplethysmography","volume":"102","author":"Zadi","year":"2018","journal-title":"Comput. Biol. Med."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"025005","DOI":"10.1088\/1361-6579\/aaa454","article-title":"New photoplethysmogram indicators for improving cuffless and continuous blood pressure estimation accuracy","volume":"39","author":"Lin","year":"2018","journal-title":"Physiol. Meas."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"eaap8674","DOI":"10.1126\/scitranslmed.aap8674","article-title":"Smartphone-based blood pressure monitoring via the oscillometric finger-pressing method","volume":"10","author":"Chandrasekhar","year":"2018","journal-title":"Sci. Transl. Med."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Dey, J., Gaurav, A., and Tiwari, V.N. (2018, January 18\u201321). InstaBP: Cuff-less Blood Pressure Monitoring on Smartphone using Single PPG Sensor. Proceedings of the 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Honolulu, HI, USA.","DOI":"10.1109\/EMBC.2018.8513189"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Acciaroli, G., Facchinetti, A., Pillonetto, G., and Sparacino, G. (2018, January 18\u201321). Non-Invasive Continuous-Time Blood Pressure Estimation from a Single Channel PPG Signal using Regularized ARX Models. Proceedings of the 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Honolulu, HI, USA.","DOI":"10.1109\/EMBC.2018.8512944"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1186\/s12938-016-0302-y","article-title":"Feasibility study for the non-invasive blood pressure estimation based on ppg morphology: Normotensive subject study","volume":"16","author":"Shin","year":"2017","journal-title":"Biomed. Eng. Online"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Chen, Y., Cheng, S., Wang, T., and Ma, T. (2017, January 11\u201315). Novel blood pressure estimation method using single photoplethysmography feature. Proceedings of the 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Seogwipo, Korea.","DOI":"10.1109\/EMBC.2017.8037172"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Gao, S.C., Wittek, P., Zhao, L., and Jiang, W.J. (2016, January 16\u201320). Data-driven estimation of blood pressure using photoplethysmographic signals. Proceedings of the 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Orlando, FL, USA.","DOI":"10.1109\/EMBC.2016.7590814"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2154","DOI":"10.1088\/0967-3334\/37\/12\/2154","article-title":"Systolic blood pressure estimation using PPG and ECG during physical exercise","volume":"37","author":"Sun","year":"2016","journal-title":"Physiol. Meas."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1177\/0954411915587957","article-title":"Inverse-model-based cuffless blood pressure estimation using a single photoplethysmography sensor","volume":"229","author":"Suzuki","year":"2015","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1097\/MBP.0000000000000057","article-title":"Toe photoplethysmographic monitor, a promising noninvasive technique for tracking systolic blood pressure trends beat-to-beat","volume":"19","author":"Fu","year":"2014","journal-title":"Blood Press. Monit."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Kondo, R., Bhuiyan, M.S., Kawanaka, H., and Oguri, K. (2014, January 26\u201330). Separate estimation of long- and short-term systolic blood pressure variability from photoplethysmograph. Proceedings of the 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Chicago, IL, USA.","DOI":"10.1109\/EMBC.2014.6943970"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1618","DOI":"10.1007\/s00134-013-2964-2","article-title":"Innovative continuous non-invasive cuffless blood pressure monitoring based on photoplethysmography technology","volume":"39","author":"Ribas","year":"2013","journal-title":"Intensive Care Med."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Fukushima, H., Kawanaka, H., Bhuiyan, M.S., and Oguri, K. (2013, January 3\u20137). Cuffless Blood Pressure Estimation Using Only Photoplethysmography based On Cardiovascular Parameters. Proceedings of the 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Osaka, Japan.","DOI":"10.1109\/EMBC.2013.6609955"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/j.artmed.2011.05.001","article-title":"Non-invasive estimate of blood glucose and blood pressure from a photoplethysmograph by means of machine learning techniques","volume":"53","year":"2011","journal-title":"Artif. Intell. Med."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"945","DOI":"10.1007\/s10439-009-9882-z","article-title":"Towards using photo-plethysmogram amplitude to measure blood pressure during sleep","volume":"38","author":"Chua","year":"2010","journal-title":"Ann. Biomed. Eng."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1803485","DOI":"10.1155\/2017\/1803485","article-title":"Cuffless blood pressure estimation based on data-oriented continuous health monitoring system","volume":"2017","author":"Atomi","year":"2017","journal-title":"Comput. Math. Methods Med."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1260\/2040-2295.6.1.121","article-title":"Experimental feasibility study of estimation of the normalized central blood pressure waveform from radial photoplethysmogram","volume":"6","author":"Zahedi","year":"2015","journal-title":"J. Healthc. Eng."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Liang, Y., Chen, Z., Ward, R., and Elgendi, M. (2018). Photoplethysmography and deep learning: Enhancing hypertension risk stratification. Biosensors, 8.","DOI":"10.3390\/bios8040101"},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Duan, K., Qian, Z., Atef, M., and Wang, G. (2016, January 16\u201320). A feature exploration methodology for learning based cuffless blood pressure measurement using photoplethysmography. Proceedings of the 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Orlando, FL, USA.","DOI":"10.1109\/EMBC.2016.7592189"},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Gaurav, A., Maheedhar, M., Tiwari, V.N., and Narayanan, R. (2016, January 16\u201320). Cuff-less PPG based continuous blood pressure monitoring: A smartphone based approach. Proceedings of the 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Orlando, FL, USA.","DOI":"10.1109\/EMBC.2016.7590775"},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Choudhury, A.D., Banerjee, R., Sinha, A., and Kundu, S. (2014, January 26\u201330). Estimating blood pressure using Windkessel model on photoplethysmogram. Proceedings of the 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Chicago, IL, USA.","DOI":"10.1109\/EMBC.2014.6944640"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"e008857","DOI":"10.1161\/CIRCIMAGING.119.008857","article-title":"Smartphone-based blood pressure measurement using transdermal optical imaging technology","volume":"12","author":"Luo","year":"2019","journal-title":"Circ. Cardiovasc. Imaging"},{"key":"ref_35","unstructured":"Theodore, A.C., Gilles Clermont, M., Dalton, A., and Finlay, G. (2019). Indications, interpretation, and techniques for arterial catheterization for invasive monitoring. UptoDate."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"836","DOI":"10.1213\/00000539-197511000-00048","article-title":"Arterial cannulation: Factors in the development of occlusion","volume":"54","author":"Kim","year":"1975","journal-title":"Anesth. Analg."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1016\/j.bpobgyn.2011.01.006","article-title":"Epidemiology of pre-eclampsia and the other hypertensive disorders of pregnancy","volume":"25","author":"Hutcheon","year":"2011","journal-title":"Best Pract. Res. Clin. Obstet. Gynaecol."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1161\/01.HYP.21.4.504","article-title":"National standard for measurement of resting and ambulatory blood pressures with automated sphygmomanometers","volume":"21","author":"White","year":"1993","journal-title":"Hypertension"}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/9\/3\/723\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T09:05:02Z","timestamp":1760173502000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/9\/3\/723"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,3,7]]},"references-count":38,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2020,3]]}},"alternative-id":["jcm9030723"],"URL":"https:\/\/doi.org\/10.3390\/jcm9030723","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,3,7]]}}}