{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T03:03:29Z","timestamp":1760238209870,"version":"build-2065373602"},"reference-count":31,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2020,7,27]],"date-time":"2020-07-27T00:00:00Z","timestamp":1595808000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JFB"],"abstract":"<jats:p>Background: The question of reconstruction of human tissues and organs with the use of medical materials is still open, because of the accurate requirements for their biological and physical features. The aim of this study was to prove the efficiency of titanium nickelide constructors in treatment of isolated orbital floor fractures or combination with zygomatico-orbital complex fractures. Methods: Patients with a fracture of zygomatico-orbital complex and\/or low orbital floor (n = 44) carried out different treatments: in the first group, osteosynthesis and endoprosthesis with titanium nickelide structures; in the second group, titan mini-plates osteosynthesis; in the third group (\u2018blow-out\u2019), endoprosthesis with a titanium nickelide mesh; and in the fourth group (\u2018blow-out\u2019), conservative treatment and monitoring (archive data) (p &gt; 0.05). The paraesthesia, diplopia, enophthalmos and exophthalmos degree were measured in points. Results: In one year, the first and second groups had no differences in level of paraesthesia (p &gt; 0.05). The absence of exophthalmos and differences between first and second groups, and between the third and the fourth groups with positive dynamics inside the groups were proved (p &lt; 0.05). In the first and third groups, enophthalmos was absent, and it increased in the second and fourth groups (p &lt; 0.01, p &lt; 0.11). Diplopia in the first and third groups was absent, and it increased in the second and fourth groups (p &lt; 0.05, p &lt; 0.01). Conclusion: The elasticity and biocompatibility of titanium nickelide make the implant insertion and restoration of the lower orbital wall anatomy easier, with good postoperative clinical results.<\/jats:p>","DOI":"10.3390\/jfb11030052","type":"journal-article","created":{"date-parts":[[2020,7,27]],"date-time":"2020-07-27T09:24:49Z","timestamp":1595841889000},"page":"52","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Titanium Nickelide in Midface Fractures Treatment"],"prefix":"10.3390","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4186-381X","authenticated-orcid":false,"given":"Liudmila","family":"Shamanaeva","sequence":"first","affiliation":[{"name":"Department of Maxillofacial Surgery, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, Russia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4388-8911","authenticated-orcid":false,"given":"Ekaterina","family":"Diachkova","sequence":"additional","affiliation":[{"name":"Department of Oral Surgery, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, Russia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pavel","family":"Petruk","sequence":"additional","affiliation":[{"name":"Department of Maxillofacial Surgery, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, Russia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kirill","family":"Polyakov","sequence":"additional","affiliation":[{"name":"Department of Maxillofacial Surgery, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, Russia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Igor","family":"Cherkesov","sequence":"additional","affiliation":[{"name":"Department of Maxillofacial Surgery, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, Russia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sergei","family":"Ivanov","sequence":"additional","affiliation":[{"name":"Department of Maxillofacial Surgery, I.M. Sechenov First Moscow State Medical University (Sechenov University), 119991 Moscow, Russia"},{"name":"Department of Maxillofacial and Oral Surgery, Peoples Friendship University of Russia (RUDN University), 117198 Moscow, Russia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2020,7,27]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"5","DOI":"10.2478\/adms-2014-0010","article-title":"Biomaterials and implants in cardiac and vascular surgery-review","volume":"14","year":"2014","journal-title":"Adv. Mater. Sci."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/j.ijom.2015.08.992","article-title":"Two-year prospective study of outcomes following total temporomandibular joint replacement","volume":"45","author":"Centeno","year":"2016","journal-title":"Int. J. Oral Maxillofac. Surg."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1237","DOI":"10.1097\/SCS.0000000000004551","article-title":"Outcomes after open reduction with internal fixation of mandible fractures","volume":"29","author":"Barry","year":"2018","journal-title":"J. Craniofac. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2016\/2908570","article-title":"New Ti-Alloys and Surface Modifications to Improve the Mechanical Properties and the Biological Response to Orthopedic and Dental Implants: A Review","volume":"2016","author":"Kirmanidou","year":"2016","journal-title":"BioMed Res. Int."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1046\/j.1365-2591.2000.00339.x","article-title":"An overview of nickel-titanium alloys used in dentistry","volume":"33","author":"Thompson","year":"2000","journal-title":"Int. Endod. J."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1016\/j.finel.2010.09.001","article-title":"An improved, fully symmetric, finite-strain phenomenological constitutive model for shape memory alloys","volume":"47","author":"Arghavani","year":"2011","journal-title":"Finite Elem. Anal. Des."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1016\/j.actbio.2008.01.013","article-title":"Critical overview of Nitinol surfaces and their modifications for medical applications","volume":"4","author":"Shabalovskaya","year":"2008","journal-title":"Acta Biomater."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/S1010-5182(02)00168-3","article-title":"Cranio-maxillofacial trauma: A 10-year review of 9543 cases with 21067 injuries","volume":"31","author":"Gassner","year":"2003","journal-title":"J. Cranio Maxillofac. Surg."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1416","DOI":"10.1097\/SCS.0b013e31821cc28d","article-title":"Analysis of Zygomatic Fractures","volume":"22","author":"Hwang","year":"2011","journal-title":"J. Craniofac. Surg."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"430.e1","DOI":"10.1016\/j.joms.2019.10.028","article-title":"Orbital Volume Correction in Orbital Floor Fractures: A Comparison of Transorbital and Transantral Techniques","volume":"78","author":"Dennis","year":"2020","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1097\/SAP.0000000000000700","article-title":"Aesthetic and Functional Outcome of Zygomatic Fractures Fixation Comparison with Resorbable Versus Titanium Plates","volume":"76","author":"Mahmoud","year":"2016","journal-title":"Ann. Plast. Surg."},{"key":"ref_12","first-page":"1","article-title":"Surgical navigation improves reductions accuracy of unilateral complicated zygomaticomaxillary complex fractures: A randomized controlled trial","volume":"2","author":"Zhang","year":"2018","journal-title":"Sci. Rep."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Hardt, N., Kessler, P., and Kuttenberger, J. (2018). Craniofacial Trauma: Diagnosis and Management, Springer.","DOI":"10.1007\/978-3-319-77210-3"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"16510","DOI":"10.1088\/2053-1591\/aaa1ff","article-title":"The e_ect of mechano-chemical treatment on structural properties of the drawn TiNi-based alloy wire","volume":"5","author":"Anikeev","year":"2018","journal-title":"Mater. Res. Express"},{"key":"ref_15","first-page":"112","article-title":"Osteosynthesis of the bones of the medium face zone with the application of titanium nickelid constructions","volume":"11","author":"Radkevich","year":"2019","journal-title":"Sib. J. Life Sci. Agric."},{"key":"ref_16","first-page":"95","article-title":"Evaluation of biocompatibility and bioresistance of the workpieces of the nickel-titanium implants with modified nanosized surface layers in the in vivo","volume":"1","author":"Nadezhdin","year":"2016","journal-title":"Biomedicine"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Shtin, V., Novikov, V., Chekalkin, T., Gunther, V., Marchenko, E., Choynzonov, E., Kang, S.B., Chang, M.J., Kang, J.H., and Obrosov, A. (2019). Repair of Orbital Post-TraumaticWall Defects by Custom-Made TiNi Mesh Endografts. J. Funct. Biomater., 10.","DOI":"10.3390\/jfb10030027"},{"key":"ref_18","first-page":"35","article-title":"Nickelid titanium mesh for orbital floor reconstruction","volume":"93","author":"Medvedev","year":"2014","journal-title":"Stomatologiia"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1544","DOI":"10.1016\/j.jcms.2018.06.008","article-title":"Correlation between increased orbital volume and enophthalmos and diplopia in patients with fractures of the orbital floor or the medial orbital wall","volume":"46","author":"Wagner","year":"2018","journal-title":"J. Cran. Maxillofac. Surg."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1054\/ijom.2002.0481","article-title":"Hertel exophthalmometry versus computed tomography and optical 3D imaging for the determination of the globe position in zygomatic fractures","volume":"33","author":"Nkenke","year":"2004","journal-title":"Int. J. Oral Maxillofac. Surg."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1097\/00006534-199002000-00006","article-title":"Toward CT-based facial fracture treatment","volume":"85","author":"Manson","year":"1990","journal-title":"Plast. Reconstr. Surg."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/j.joms.2003.01.006","article-title":"Status of the internal orbit after reduction of zygomaticomaxillary complex fractures","volume":"62","author":"Ellis","year":"2004","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"894","DOI":"10.1016\/j.joms.2012.10.031","article-title":"Intraoperative imaging with a 3D C-arm system after zygomatico-orbital complex fracture reduction","volume":"71","author":"Wilde","year":"2013","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1001\/jamafacial.2019.0201","article-title":"Trends in concurrent orbital floor repair during zygomaticomaxillary complex fracture repair","volume":"21","author":"Flynn","year":"2019","journal-title":"JAMA Facial Plast. Surg."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/01.prs.0000294655.16607.ea","article-title":"MOC-PSSM CME article: Zygomatic fractures","volume":"121","author":"Evans","year":"2008","journal-title":"Plast. Reconstr. Surg."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/j.ajoms.2017.11.006","article-title":"The clinical course of diplopia associated with zygomaticomaxillary complex fractures before and after surgery","volume":"30","author":"Salma","year":"2018","journal-title":"J. Oral Maxillofac. Surg. Med. Pathol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1097\/IOP.0000000000001162","article-title":"Assessment of infraorbital hypesthesia following orbital floor and zygomaticomaxillary complex fractures using a novel sensory grading system","volume":"35","author":"Homer","year":"2019","journal-title":"Ophthalmic Plast. Reconstr. Surg."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1542","DOI":"10.1016\/j.jcms.2019.07.009","article-title":"Comparative evaluation of 2-point vs 3-point fixation in the treatment of zygomaticomaxillary complex fractures\u2014A systematic review","volume":"47","author":"Gadkari","year":"2019","journal-title":"J. Craniomaxillofac. Surg."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"836","DOI":"10.1016\/j.bjoms.2017.06.011","article-title":"Severe distortion of an orbital titanium mesh implant after recurrent facial trauma: A potential threat to the orbital contents?","volume":"55","author":"Foletti","year":"2017","journal-title":"Br. J. Oral Maxillofac. Surg."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/1097-0347(200101)23:1<1::AID-HED1>3.0.CO;2-2","article-title":"Fixation methods in mandibular reconstruction using fibula grafts: A comparative study into the relative strength of three different types of osteosynthesis","volume":"23","author":"Strackee","year":"2001","journal-title":"Head Neck"},{"key":"ref_31","unstructured":"Gunter, V.E. (2011). Shape-Memory Medical Materials. Shape-Memory Materials and Implants, MITs. (In Russian)."}],"container-title":["Journal of Functional Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2079-4983\/11\/3\/52\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T09:51:58Z","timestamp":1760176318000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2079-4983\/11\/3\/52"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,27]]},"references-count":31,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2020,9]]}},"alternative-id":["jfb11030052"],"URL":"https:\/\/doi.org\/10.3390\/jfb11030052","relation":{},"ISSN":["2079-4983"],"issn-type":[{"type":"electronic","value":"2079-4983"}],"subject":[],"published":{"date-parts":[[2020,7,27]]}}}