{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,25]],"date-time":"2026-10-25T19:33:10Z","timestamp":1792956790877,"version":"4.5.0"},"reference-count":35,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2022,5,23]],"date-time":"2022-05-23T00:00:00Z","timestamp":1653264000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"World Class Research UNDIP","award":["118-23\/UN7.6.1\/PP\/2021"],"award-info":[{"award-number":["118-23\/UN7.6.1\/PP\/2021"]}]},{"name":"World Class Research UNDIP","award":["0014\/UN9\/SK.LP2M.PT\/2021"],"award-info":[{"award-number":["0014\/UN9\/SK.LP2M.PT\/2021"]}]},{"name":"DIPA of Public Service Agency of Sriwijaya University 2021","award":["118-23\/UN7.6.1\/PP\/2021"],"award-info":[{"award-number":["118-23\/UN7.6.1\/PP\/2021"]}]},{"name":"DIPA of Public Service Agency of Sriwijaya University 2021","award":["0014\/UN9\/SK.LP2M.PT\/2021"],"award-info":[{"award-number":["0014\/UN9\/SK.LP2M.PT\/2021"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JFB"],"abstract":"<jats:p>Due to various concerns about the use of metal-on-metal that is detrimental to users, the use of metal as acetabular cup material was later changed to ultra high molecular weight polyethylene (UHMWPE). However, the wear on UHMWPE releases polyethylene wear particles, which can trigger a negative body response and contribute to osteolysis. For reducing the wear of polyethylene, one of the efforts is to investigate the selection of metal materials. Cobalt chromium molybdenum (CoCrMo), stainless steel 316L (SS 316L), and titanium alloy (Ti6Al4V) are the frequently employed materials. The computational evaluation of contact pressure was carried out using a two-dimensional axisymmetric model for UHMWPE acetabular cup paired with metal femoral head under gait cycle in this study. The results show Ti6Al4V-on-UHMWPE is able to reduce cumulative contact pressure compared to SS 316L-on-UHMWPE and CoCrMo-on-UHMWPE. Compared to Ti6Al4V-on-UHMWPE at peak loading, the difference in cumulative contact pressure to respective maximum contact pressure is 9.740% for SS 316L-on-UHMWPE and 11.038% for CoCrMo-on-UHMWPE.<\/jats:p>","DOI":"10.3390\/jfb13020064","type":"journal-article","created":{"date-parts":[[2022,5,23]],"date-time":"2022-05-23T22:57:22Z","timestamp":1653346642000},"page":"64","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":102,"title":["Computational Contact Pressure Prediction of CoCrMo, SS 316L and Ti6Al4V Femoral Head against UHMWPE Acetabular Cup under Gait Cycle"],"prefix":"10.3390","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6172-2635","authenticated-orcid":false,"given":"J.","family":"Jamari","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, Faculty of Engineering, Diponegoro University, Semarang 50275, Central Java, Indonesia"},{"name":"Undip Biomechanics Engineering & Research Centre (UBM-ERC), Diponegoro University, Semarang 50275, Central Java, Indonesia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8845-7202","authenticated-orcid":false,"given":"Muhammad Imam","family":"Ammarullah","sequence":"additional","affiliation":[{"name":"Undip Biomechanics Engineering & Research Centre (UBM-ERC), Diponegoro University, Semarang 50275, Central Java, Indonesia"},{"name":"Department of Mechanical Engineering, Faculty of Engineering, Pasundan University, Bandung 40264, West Java, Indonesia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2368-193X","authenticated-orcid":false,"given":"Gatot","family":"Santoso","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Faculty of Engineering, Pasundan University, Bandung 40264, West Java, Indonesia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9971-2862","authenticated-orcid":false,"given":"S.","family":"Sugiharto","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Faculty of Engineering, Pasundan University, Bandung 40264, West Java, Indonesia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1128-8161","authenticated-orcid":false,"given":"Toto","family":"Supriyono","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Faculty of Engineering, Pasundan University, Bandung 40264, West Java, Indonesia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0295-7207","authenticated-orcid":false,"given":"Akbar Teguh","family":"Prakoso","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Faculty of Engineering, Sriwijaya University, Indralaya 30662, South Sumatra, Indonesia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7867-9744","authenticated-orcid":false,"given":"Hasan","family":"Basri","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Faculty of Engineering, Sriwijaya University, Indralaya 30662, South Sumatra, Indonesia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5231-8665","authenticated-orcid":false,"given":"Emile","family":"van der Heide","sequence":"additional","affiliation":[{"name":"Laboratory for Surface Technology and Tribology, Faculty of Engineering Technology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,5,23]]},"reference":[{"key":"ref_1","unstructured":"EU\u2014Indonesia Business Network (2019). EIBN Sector Reports: Medical Devices, EU\u2014Indonesia Business Network. [2019 ed.]."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Pozzuoli, A., Berizzi, A., Crim\u00ec, A., Belluzzi, E., Frigo, A.C., de Conti, G., Nicolli, A., Trevisan, A., Biz, C., and Ruggieri, P. (2020). Metal Ion Release, Clinical and Radiological Outcomes in Large Diameter Metal-on-Metal Total Hip Arthroplasty at Long-Term Follow-Up. Diagnostics, 10.","DOI":"10.3390\/diagnostics10110941"},{"key":"ref_3","unstructured":"Australian Orthopaedic Association National Joint Replacement Registry (2020). Annual Report 2020, Australian Orthopaedic Association. [2020 ed.]."},{"key":"ref_4","first-page":"1063","article-title":"First Case Report of Vanadium Metallosis after Ceramic-on-Ceramic Total Hip Arthroplasty","volume":"27","author":"Pesce","year":"2013","journal-title":"J. Biol. Regul. Homeost. Agents"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Allizond, V., Comini, S., Cuffini, A.M., and Banche, G. (2022). Current Knowledge on Biomaterials for Orthopedic Applications Modified to Reduce Bacterial Adhesive Ability. Antibiotics, 11.","DOI":"10.3390\/antibiotics11040529"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Nicolli, A., Trevisan, A., Bortoletti, I., Pozzuoli, A., Ruggieri, P., Martinelli, A., Gambalunga, A., and Carrieri, M. (2020). Biological Monitoring of Metal Ions Released from Hip Prostheses. Int. J. Environ. Res. Public Health, 17.","DOI":"10.3390\/ijerph17093223"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s12306-018-0539-7","article-title":"Reconstruction of Failed Acetabular Component in the Presence of Severe Acetabular Bone Loss: A Systematic Review","volume":"103","author":"Volpin","year":"2019","journal-title":"Musculoskelet. Surg."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Piconi, C., and Sprio, S. (2021). Oxide Bioceramic Composites in Orthopedics and Dentistry. J. Compos. Sci., 5.","DOI":"10.3390\/jcs5080206"},{"key":"ref_9","first-page":"110","article-title":"An Experimental Investigation on Tribological Performance of UHMWPE Composite under Textured Dry Sliding Conditions","volume":"24","author":"Aher","year":"2020","journal-title":"J. Tribol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jmbbm.2018.07.017","article-title":"Long-Term Wear Failure Analysis of Uhmwpe Acetabular Cup in Total Hip Replacement","volume":"87","author":"Shahemi","year":"2018","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"55","DOI":"10.24845\/ijfac.v1.i3.55","article-title":"Hydroxyapatite Coating on Alloys CoCrMo-TiN with Sol-Gel Method","volume":"1","author":"Charlena","year":"2016","journal-title":"Indones. J. Fundam. Appl. Chem."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1593","DOI":"10.14716\/ijtech.v10i8.3476","article-title":"Effect of Feed Metal Flow Rate on Low-Cost Plasma Atomizer for Fabricating 316L Stainless Steel Powder","volume":"10","author":"Dharmanto","year":"2019","journal-title":"Int. J. Technol."},{"key":"ref_13","first-page":"765","article-title":"Development of Ti6Al-4V Based-Miniplate Manufactured by Electrical Discharge Machining as Maxillofacial Implant","volume":"10","author":"Qosim","year":"2018","journal-title":"J. Fundam. Appl. Sci."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"25","DOI":"10.3389\/fmech.2020.00025","article-title":"Comparative Analysis of Error Sources in the Determination of Wear Volumes of Oscillating Ball-on-Plane Tests","volume":"6","author":"Reichelt","year":"2020","journal-title":"Front. Mech. Eng."},{"key":"ref_15","first-page":"60","article-title":"Permeability Study of Functionally Graded Scaffold Based on Morphology of Cancellous Bone","volume":"17","author":"Akbar","year":"2021","journal-title":"Malays. J. Med. Health Sci."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Lorkowski, J., and Pokorski, M. (2022). In Silico Finite Element Modeling of Stress Distribution in Osteosynthesis after Pertrochanteric Fractures. J. Clin. Med., 11.","DOI":"10.3390\/jcm11071885"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"981","DOI":"10.1063\/1.1721448","article-title":"Contact and Rubbing of Flat Surfaces","volume":"24","author":"Archard","year":"1953","journal-title":"J. Appl. Phys."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Skvortsova, S., Orlov, A., Valyano, G., Spektor, V., and Mamontova, N. (2021). Wear Resistance of Ti\u20136Al\u20134V Alloy Ball Heads for Use in Implants. J. Funct. Biomater., 12.","DOI":"10.3390\/jfb12040065"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1177\/0954411912456926","article-title":"The Effect of Cup Orientation and Coverage on Contact Mechanics and Range of Motion of Metal-on-Metal Hip Resurfacing Arthroplasty","volume":"226","author":"Wang","year":"2012","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"021402","DOI":"10.1115\/1.4023207","article-title":"Wear Simulation of Metal-on-Metal Hip Replacements with Frictional Contact","volume":"135","author":"Mattei","year":"2013","journal-title":"J. Tribol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1650020","DOI":"10.1142\/S0219519416500202","article-title":"Predicting the Wear of Soft-on-Hard Bearing Couples for Human Hip Prosthesis Using Finite Element Concepts","volume":"16","author":"Shankar","year":"2016","journal-title":"J. Mech. Med. Biol."},{"key":"ref_22","first-page":"18","article-title":"2D Computational Tresca Stress Prediction of CoCrMo-on-UHMWPE Bearing of Total Hip Prosthesis Based on Body Mass Index","volume":"17","author":"Ammarullah","year":"2021","journal-title":"Malays. J. Med. Health Sci."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Wu, J., Taylor, D., Forst, R., and Seehaus, F. (2021). Does Pelvic Orientation Influence Wear Measurement of the Acetabular Cup in Total Hip Arthroplasty\u2014An Experimental Study. Appl. Sci., 11.","DOI":"10.3390\/app112110014"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Jamari, J., Ammarullah, M.I., Saad, A.P.M., Syahrom, A., Uddin, M., van der Heide, E., and Basri, H. (2021). The Effect of Bottom Profile Dimples on the Femoral Head on Wear in Metal-on-Metal Total Hip Arthroplasty. J. Funct. Biomater., 12.","DOI":"10.3390\/jfb12020038"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Ammarullah, M.I., Afif, I.Y., Maula, M.I., Winarni, T.I., Tauviqirrahman, M., Akbar, I., Basri, H., Heide, E., and Van Der Jamari, J. (2021). Tresca Stress Simulation of Metal-on-Metal Total Hip Arthroplasty during Normal Walking Activity. Materials, 14.","DOI":"10.3390\/ma14247554"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Ammarullah, M.I., Afif, I.Y., Maula, M.I., Winarni, T.I., Tauviqirrahman, M., and Jamari, J. (Mater. Today Proc., 2022). Tresca Stress Evaluation of Metal-on-UHMWPE Total Hip Arthroplasty during Peak Loading from Normal Walking Activity, Mater. Today Proc., in press.","DOI":"10.1016\/j.matpr.2022.02.055"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1","DOI":"10.32802\/asmscj.2020.526","article-title":"Tribological Studies of Different Bioimplant Materials for Orthopaedic Application","volume":"13","author":"Gaval","year":"2020","journal-title":"ASM Sci. J."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"012018","DOI":"10.1088\/1757-899X\/384\/1\/012018","article-title":"Wear Prediction of UHMWPE Acetabular Cup against CP Titanium Femoral Head in a Hip Joint Simulator","volume":"384","author":"Handoko","year":"2018","journal-title":"IOP Conf. Ser. Mater. Sci. Eng."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"125","DOI":"10.3390\/prosthesis4010013","article-title":"Gait Performance of Friction-Based Prosthetic Knee Joint Swing-Phase Controllers in Under-Resourced Settings","volume":"4","author":"Andrysek","year":"2022","journal-title":"Prosthesis"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"042012","DOI":"10.1088\/1742-6596\/1198\/4\/042012","article-title":"The Analysis of Dimple Geometry on Artificial Hip Joint to the Performance of Lubrication","volume":"1198","author":"Basri","year":"2019","journal-title":"J. Phys. Conf. Ser."},{"key":"ref_31","unstructured":"Dassault Syst\u00e8mes (2016). Abaqus Analysis User\u2019s Guide Volume IV: Elements, Dassault Syst\u00e8mes Simulia Corp."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1515\/corrrev-2020-0001","article-title":"Biocompatibility and Corrosion Resistance of Metallic Biomaterials","volume":"38","author":"Ali","year":"2020","journal-title":"Corros. Rev."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"19","DOI":"10.4028\/www.scientific.net\/AMM.735.19","article-title":"Metallic Biomaterials for Medical Implant Applications: A Review","volume":"735","author":"Zaman","year":"2015","journal-title":"Appl. Mech. Mater."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"020017","DOI":"10.1063\/5.0072856","article-title":"Wear Analysis of Acetabular Cup on Metal-on-Metal Total Hip Arthroplasty with Dimple Addition Using Finite Element Method","volume":"2391","author":"Ammarullah","year":"2022","journal-title":"AIP Conf. Proc."},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Vendittoli, P.-A., Martinov, S., Morcos, M.W., Sivaloganathan, S., and Blakeney, W.G. (2022). Personalized Hip Joint Replacement with Large Diameter Head: Current Concepts. J. Clin. Med., 11.","DOI":"10.3390\/jcm11071918"}],"container-title":["Journal of Functional Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2079-4983\/13\/2\/64\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T23:17:11Z","timestamp":1760138231000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2079-4983\/13\/2\/64"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,23]]},"references-count":35,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2022,6]]}},"alternative-id":["jfb13020064"],"URL":"https:\/\/doi.org\/10.3390\/jfb13020064","relation":{},"ISSN":["2079-4983"],"issn-type":[{"value":"2079-4983","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,23]]}}}