{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T05:22:03Z","timestamp":1791177723652,"version":"4.1.0"},"reference-count":106,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2024,12,23]],"date-time":"2024-12-23T00:00:00Z","timestamp":1734912000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JFB"],"abstract":"<jats:p>Intraocular lenses (IOLs) play a pivotal role in restoring vision following cataract surgery. The evolution of polymeric biomaterials has been central to addressing challenges such as biocompatibility, optical clarity, mechanical stability, and resistance to opacification. This review explores essential requirements for IOL biomaterials, emphasizing their ability to mitigate complications like posterior capsule opacification (PCO) and dysphotopsias while maintaining long-term durability and visual quality. Traditional polymeric materials, including polymethyl methacrylate (PMMA), silicone, and acrylic polymers, are critically analyzed alongside cutting-edge innovations such as hydrogels, shape memory polymers, and light-adjustable lenses (LALs). Advances in polymer engineering have enabled these materials to achieve enhanced flexibility, transparency, and biocompatibility, driving their adoption in modern IOL design. Functionalization strategies, including surface modifications and drug-eluting designs, highlight advancements in preventing inflammation, infection, and other complications. The incorporation of UV-blocking and blue-light-filtering agents is also examined for their potential in reducing retinal damage. Furthermore, emerging technologies like nanotechnology and smart polymer-based biomaterials offer promising avenues for personalized, biocompatible IOLs with enhanced performance. Clinical outcomes, including visual acuity, contrast sensitivity, and patient satisfaction, are evaluated to provide an understanding of the current advancements and limitations in IOL development. We also discuss the current challenges and future directions, underscoring the need for cost-effective, innovative polymer-based solutions to optimize surgical outcomes and improve patients\u2019 quality of life.<\/jats:p>","DOI":"10.3390\/jfb15120391","type":"journal-article","created":{"date-parts":[[2024,12,24]],"date-time":"2024-12-24T02:50:56Z","timestamp":1735008656000},"page":"391","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["Innovative Polymeric Biomaterials for Intraocular Lenses in Cataract Surgery"],"prefix":"10.3390","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1662-6900","authenticated-orcid":false,"given":"Kevin Y.","family":"Wu","sequence":"first","affiliation":[{"name":"Department of Surgery, Division of Ophthalmology, University of Sherbrooke, Sherbrooke, QC J1G 2E8, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rebecca","family":"Khammar","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Universit\u00e9 de Montr\u00e9al, Montr\u00e9al, QC H3T 1J4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hafsah","family":"Sheikh","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Queens University, Kingston, ON K7M 1G2, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1069-630X","authenticated-orcid":false,"given":"Michael","family":"Marchand","sequence":"additional","affiliation":[{"name":"Department of Surgery, Division of Ophthalmology, University of Sherbrooke, Sherbrooke, QC J1G 2E8, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2024,12,23]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Luo, C., Wang, H., Chen, X., Xu, J., Yin, H., and Yao, K. (2022). Recent Advances of Intraocular Lens Materials and Surface Modification in Cataract Surgery. Front. Bioeng. Biotechnol., 10.","DOI":"10.3389\/fbioe.2022.913383"},{"key":"ref_2","first-page":"CD012516","article-title":"Intraocular Lens Optic Edge Design for the Prevention of Posterior Capsule Opacification after Cataract Surgery","volume":"2021","author":"Maedel","year":"2021","journal-title":"Cochrane Database Syst. Rev."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"221","DOI":"10.4274\/tjo.10437","article-title":"Biocompatibility of Intraocular Lenses","volume":"47","author":"Karel","year":"2017","journal-title":"Turk. J. Ophthalmol."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Wu, H., Wang, J., Fan, W., Zhong, Q., Xue, R., Li, S., Song, Z., and Tao, Y. (2024). Eye of the Future: Unlocking the Potential Utilization of Hydrogels in Intraocular Lenses. Bioeng. Transl. Med., 9.","DOI":"10.1002\/btm2.10664"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"e74","DOI":"10.1016\/j.ophtha.2020.06.055","article-title":"Intraocular Lenses: Overview of Designs, Materials, and Pathophysiologic Features","volume":"128","author":"Werner","year":"2021","journal-title":"Ophthalmology"},{"key":"ref_6","first-page":"CD011977","article-title":"Blue-light Filtering Intraocular Lenses (IOLs) for Protecting Macular Health","volume":"5","author":"Downie","year":"2018","journal-title":"Cochrane Database Syst. Rev."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1466","DOI":"10.1515\/epoly.2009.9.1.1466","article-title":"Materials for Intraocular Lenses (IOLs): Review of Developments to Achieve Biocompatibility","volume":"9","author":"Tripti","year":"2009","journal-title":"e-Polymers"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/S0886-3350(01)00742-8","article-title":"Biocompatibility of Intraocular Lenses","volume":"27","author":"Amon","year":"2001","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Tan, X., Zhan, J., Zhu, Y., Cao, J., Wang, L., Liu, S., Wang, Y., Liu, Z., Qin, Y., and Wu, M. (2017). Improvement of Uveal and Capsular Biocompatibility of Hydrophobic Acrylic Intraocular Lens by Surface Grafting with 2-Methacryloyloxyethyl Phosphorylcholine-Methacrylic Acid Copolymer. Sci. Rep., 7.","DOI":"10.1038\/srep40462"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Saika, S., Werner, L., and Lovicu, F.J. (2014). Capsular and Uveal Biocompatibility of Different IOLs in Eyes with and Without Associated Conditions. Lens Epithelium and Posterior Capsular Opacification, Springer.","DOI":"10.1007\/978-4-431-54300-8"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1097\/ICU.0b013e3282f20132","article-title":"Biocompatibility of Intraocular Lens Materials","volume":"19","author":"Werner","year":"2008","journal-title":"Curr. Opin. Ophthalmol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1016\/j.jcrs.2018.01.033","article-title":"Assessment of Straylight and the Modulation Transfer Function of Intraocular Lenses with Centrally Localized Opacification Associated with the Intraocular Injection of Gas","volume":"44","author":"Labuz","year":"2018","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_13","first-page":"2687385","article-title":"Biomaterial Influence on Intraocular Lens Performance: An Overview","volume":"2018","year":"2018","journal-title":"J. Ophthalmol."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Berggren, C.C., Ameku, K.A., and Pedrigi, R.M. (2021). Altered Stress Field of the Human Lens Capsule after Cataract Surgery. J. Biomech., 115.","DOI":"10.1016\/j.jbiomech.2020.110127"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Pusnik, A., Petrovski, G., and Lumi, X. (2022). Dysphotopsias or Unwanted Visual Phenomena after Cataract Surgery. Life, 13.","DOI":"10.3390\/life13010053"},{"key":"ref_16","first-page":"1353","article-title":"Refractive Index and Its Impact on Pseudophakic Dysphotopsia","volume":"9","author":"Radmall","year":"2015","journal-title":"Clin. Ophthalmol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"388","DOI":"10.3928\/1081597X-20200420-01","article-title":"Three-Dimensional Assessments of Intraocular Lens Stability with High-Speed Swept-Source Optical Coherence Tomography","volume":"36","author":"Ding","year":"2020","journal-title":"J. Refract. Surg."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Liu, C., and Shalaby Bardan, A. (2021). Posterior Capsule Opacification. Cataract Surgery: Pearls and Techniques, Springer International Publishing.","DOI":"10.1007\/978-3-030-38234-6"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1301","DOI":"10.1098\/rstb.2010.0341","article-title":"The Lens as a Model for Fibrotic Disease","volume":"366","author":"Eldred","year":"2011","journal-title":"Philos. Trans. R. Soc. B Biol. Sci."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"5587","DOI":"10.1167\/iovs.10-7073","article-title":"Imaging of Forward Light-Scatter by Opacified Posterior Capsules Isolated from Pseudophakic Donor Eyes","volume":"52","author":"Franssen","year":"2011","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"100905","DOI":"10.1016\/j.preteyeres.2020.100905","article-title":"Posterior Capsule Opacification: What\u2019s in the Bag?","volume":"82","author":"Wormstone","year":"2021","journal-title":"Prog. Retin. Eye Res."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"960","DOI":"10.1038\/s41433-019-0630-9","article-title":"5 Year Incidence of YAG Capsulotomy and PCO after Cataract Surgery with Single-Piece Monofocal Intraocular Lenses: A Real-World Evidence Study of 20,763 Eyes","volume":"34","author":"Ursell","year":"2020","journal-title":"Eye"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1007\/s10389-017-0851-y","article-title":"German Claims Data Analysis to Assess Impact of Different Intraocular Lenses on Posterior Capsule Opacification and Related Healthcare Costs","volume":"26","author":"Kossack","year":"2018","journal-title":"J. Public Health"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.1016\/S0886-3350(97)80026-0","article-title":"Sandwich Theory: Bioactivity-Based Explanation for Posterior Capsule Opacification","volume":"23","author":"Linnola","year":"1997","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1080\/09286580490515116","article-title":"Comparison of Nd:YAG Capsulotomy Rates Following Phacoemulsification with Implantation of PMMA, Silicone, or Acrylic Intra-Ocular Lenses in Four European Countries","volume":"11","author":"Auffarth","year":"2004","journal-title":"Ophthalmic Epidemiol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1016\/S0886-3350(98)80325-8","article-title":"Adhesiveness of AcrySof to a Collagen Film","volume":"24","author":"Nagata","year":"1998","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_27","first-page":"819","article-title":"Fibronectin Adhesive Properties of Various Intraocular Lens Materials","volume":"54","author":"Ong","year":"2013","journal-title":"Investig. Ophtalmol. Vis. Sci."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Kapoor, S., Gupta, S., Kapoor, S., and Gupta, S. (2020). Basic Science of Intraocular Lens Materials. Intraocular Lens, IntechOpen.","DOI":"10.5772\/intechopen.92573"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1016\/j.ophtha.2016.11.010","article-title":"Long-Term Posterior Capsule Opacification Reduction with Square-Edge Polymethylmethacrylate Intraocular Lens: Randomized Controlled Study","volume":"124","author":"Haripriya","year":"2017","journal-title":"Ophthalmology"},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Vacalebre, M., Frison, R., Corsaro, C., Neri, F., Santoro, A., Conoci, S., Anastasi, E., Curatolo, M.C., and Fazio, E. (2023). Current State of the Art and Next Generation of Materials for a Customized IntraOcular Lens According to a Patient-Specific Eye Power. Polymers, 15.","DOI":"10.3390\/polym15061590"},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"\u010canovi\u0107, S., Konjevoda, S., Pavi\u010di\u0107, A.D., Stani\u0107, R., \u010canovi\u0107, S., Konjevoda, S., Pavi\u010di\u0107, A.D., and Stani\u0107, R. (2019). Intraocular Lens (IOL) Materials. Intraocular Lens, IntechOpen.","DOI":"10.5772\/intechopen.89985"},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Li, Y., Wang, J., Chen, Z., and Tang, X. (2013). Effect of Hydrophobic Acrylic versus Hydrophilic Acrylic Intraocular Lens on Posterior Capsule Opacification: Meta-Analysis. PLoS ONE, 8.","DOI":"10.1371\/journal.pone.0077864"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"969","DOI":"10.3109\/02713683.2014.978476","article-title":"New Hydrophobic IOL Materials and Understanding the Science of Glistenings","volume":"40","author":"Tetz","year":"2015","journal-title":"Curr. Eye Res."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Yildirim, T.M., Fang, H., Schickhardt, S.K., Wang, Q., Merz, P.R., and Auffarth, G.U. (2020). Glistening Formation in a New Hydrophobic Acrylic Intraocular Lens. BMC Ophthalmol., 20.","DOI":"10.1186\/s12886-020-01430-z"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1020","DOI":"10.1016\/j.jcrs.2019.01.025","article-title":"The Impact of Glistenings on the Optical Quality of a Hydrophobic Acrylic Intraocular Lens","volume":"45","author":"Weindler","year":"2019","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Ozates, S., Berker, N., Cakar Ozdal, P., and Ozdamar Erol, Y. (2020). Phacoemulsification in Patients with Uveitis: Long-Term Outcomes. BMC Ophthalmol., 20.","DOI":"10.1186\/s12886-020-01373-5"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.1007\/s40123-022-00646-0","article-title":"Refractive Outcome and 5-Year Capsulotomy Rate of Hydrophobic and Hydrophilic IOLs with Similar Optical Design: A Contralateral Study","volume":"12","author":"Bellucci","year":"2023","journal-title":"Ophthalmol. Ther."},{"key":"ref_38","first-page":"1700","article-title":"Calcification of Hydrophilic Acrylic Intraocular Lenses Following Secondary Surgical Procedures in the Anterior and Posterior Segments","volume":"103","author":"Darcy","year":"2019","journal-title":"Br. J. Ophthalmol."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1021\/acs.biomac.0c01525","article-title":"Polymeric Materials for Eye Surface and Intraocular Applications","volume":"22","author":"Karayilan","year":"2021","journal-title":"Biomacromolecules"},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Cui, H., Li, P., Su, Z., Guan, S., Dong, H., and Dong, X. (2024). Preparation and Stability Study of an Injectable Hydrogel for Artificial Intraocular Lenses. Polymers, 16.","DOI":"10.3390\/polym16182562"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1521","DOI":"10.18240\/ijo.2020.10.03","article-title":"Biosafety of a 3D-Printed Intraocular Lens Made of a Poly(Acrylamide-Co-Sodium Acrylate) Hydrogel in Vitro and in Vivo","volume":"13","author":"Li","year":"2020","journal-title":"Int. J. Ophthalmol."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1136\/bjo.2003.023580","article-title":"Posterior Capsule Opacification after Implantation of a Hydrogel Intraocular Lens","volume":"88","author":"Hayashi","year":"2004","journal-title":"Br. J. Ophthalmol."},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Toffoletto, N., Salema-Oom, M., Anguiano Igea, S., Alvarez-Lorenzo, C., Saramago, B., and Serro, A.P. (2021). Drug-Loaded Hydrogels for Intraocular Lenses with Prophylactic Action against Pseudophakic Cystoid Macular Edema. Pharmaceutics, 13.","DOI":"10.3390\/pharmaceutics13070976"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"15885","DOI":"10.1021\/acs.iecr.1c03083","article-title":"Additive Manufacturing of Shape Memory Polymer Composites for Futuristic Technology","volume":"60","author":"Patadiya","year":"2021","journal-title":"Ind. Eng. Chem. Res."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1163\/092050609X12567412849136","article-title":"Synthesis and Characterization of Shape Memory (Meth)Acrylate Co-Polymers and Their Cytocompatibility In Vitro","volume":"22","author":"Song","year":"2011","journal-title":"J. Biomater. Sci. Polym. Ed."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1016\/j.jcrs.2018.01.031","article-title":"Risk Factors for Refractive Error after Cataract Surgery: Analysis of 282\u2009811 Cataract Extractions Reported to the European Registry of Quality Outcomes for Cataract and Refractive Surgery","volume":"44","author":"Dickman","year":"2018","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1186\/s40662-018-0110-5","article-title":"Intraocular Lens Power Calculation in Eyes with Previous Corneal Refractive Surgery","volume":"5","author":"Savini","year":"2018","journal-title":"Eye Vis."},{"key":"ref_48","first-page":"8","article-title":"Long-Term Follow-up and Clinical Evaluation of the Light-Adjustable Intraocular Lens Implanted after Cataract Removal: 7-Year Results","volume":"46","author":"Schojai","year":"2020","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"e206","DOI":"10.1016\/j.ophtha.2020.12.025","article-title":"Future Intraocular Lens Technologies","volume":"128","author":"Dick","year":"2021","journal-title":"Ophthalmology"},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Huang, Y.-S., Bertrand, V., Bozukova, D., Pagnoulle, C., Labrug\u00e8re, C., Pauw, E.D., Pauw-Gillet, M.-C.D., and Durrieu, M.-C. (2014). RGD Surface Functionalization of the Hydrophilic Acrylic Intraocular Lens Material to Control Posterior Capsular Opacification. PLoS ONE, 9.","DOI":"10.1371\/journal.pone.0114973"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1089\/jop.2020.0134","article-title":"Surface Modification of Intraocular Lens with Hydrophilic Poly(Sulfobetaine Methacrylate) Brush for Posterior Capsular Opacification Prevention","volume":"37","author":"Wang","year":"2021","journal-title":"J. Ocul. Pharmacol. Ther."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1177\/0885328216638547","article-title":"Surface PEGylation of Intraocular Lens for PCO Prevention: An in Vivo Evaluation","volume":"31","author":"Xu","year":"2016","journal-title":"J. Biomater. Appl."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"1546","DOI":"10.1039\/D0TB02802A","article-title":"Surface Modification of Intraocular Lenses via Photodynamic Coating for Safe and Effective PCO Prevention","volume":"9","author":"Tang","year":"2021","journal-title":"J. Mater. Chem. B"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"3579","DOI":"10.1021\/acsabm.1c00089","article-title":"Intraocular Lens with Mussel-Inspired Coating for Preventing Posterior Capsule Opacification via Photothermal Effect","volume":"4","author":"Xu","year":"2021","journal-title":"ACS Appl. Bio Mater."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1097\/OPX.0000000000001642","article-title":"Poly 2-Methacryloyloxyethyl Phosphorylcholine Protects Corneal Cells and Contact Lenses from Desiccation Damage","volume":"98","author":"Olivieri","year":"2021","journal-title":"Optom. Vis. Sci."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"1065","DOI":"10.1021\/acsbiomaterials.0c01705","article-title":"Drug-Eluting Hydrophilic Coating Modification of Intraocular Lens via Facile Dopamine Self-Polymerization for Posterior Capsular Opacification Prevention","volume":"7","author":"Liu","year":"2021","journal-title":"ACS Biomater. Sci. Eng."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1080\/09205063.2020.1865691","article-title":"Antiproliferative Drug-Loaded Multi-Functionalized Intraocular Lens for Reducing Posterior Capsular Opacification","volume":"32","author":"Huang","year":"2021","journal-title":"J. Biomater. Sci. Polym. Ed."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1016\/j.ejpb.2020.02.011","article-title":"Supercritical Fluid Technology for the Development of Innovative Ophthalmic Medical Devices: Drug Loaded Intraocular Lenses to Mitigate Posterior Capsule Opacification","volume":"149","author":"Ongkasin","year":"2020","journal-title":"Eur. J. Pharm. Biopharm."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/j.actbio.2021.11.018","article-title":"Centrifugally Concentric Ring-Patterned Drug-Loaded Polymeric Coating as an Intraocular Lens Surface Modification for Efficient Prevention of Posterior Capsular Opacification","volume":"138","author":"Lu","year":"2022","journal-title":"Acta Biomater."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"901","DOI":"10.1055\/s-0034-1368566","article-title":"Zuverl\u00e4ssiger UV-Schutz durch Intraokularlinsen\u2014Rationale und Qualit\u00e4tsanforderungen","volume":"231","author":"Augustin","year":"2014","journal-title":"Klin. Monatsbl\u00e4tter F\u00fcr Augenheilkd."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"2065","DOI":"10.1007\/s00417-019-04390-3","article-title":"Phototoxicity of Environmental Radiations in Human Lens: Revisiting the Pathogenesis of UV-Induced Cataract","volume":"257","author":"Kamari","year":"2019","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"ref_62","doi-asserted-by":"crossref","unstructured":"Zhu, X., Zou, H., Yu, Y., Sun, Q., and Zhao, N. (2012). Comparison of Blue Light-Filtering IOLs and UV Light-Filtering IOLs for Cataract Surgery: A Meta-Analysis. PLoS ONE, 7.","DOI":"10.1371\/journal.pone.0033013"},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"e87","DOI":"10.1111\/j.1442-9071.2011.02620.x","article-title":"Filtering Blue Light Reduces Light-Induced Oxidative Stress, Senescence and Accumulation of Extracellular Matrix Proteins in Human Retinal Pigment Epithelium Cells","volume":"40","author":"Kernt","year":"2012","journal-title":"Clin. Experiment. Ophthalmol."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1038\/eye.2015.267","article-title":"Ultraviolet or Blue-Filtering Intraocular Lenses: What Is the Evidence?","volume":"30","author":"Downes","year":"2016","journal-title":"Eye"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.ophtha.2021.07.007","article-title":"Postoperative Endophthalmitis in Immediate Sequential Bilateral Cataract Surgery: A Nationwide Registry Study","volume":"129","author":"Friling","year":"2022","journal-title":"Ophthalmology"},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1097\/ICU.0000000000000326","article-title":"Endophthalmitis after Cataract Surgery: Epidemiology, Risk Factors, and Evidence on Protection","volume":"28","author":"Garg","year":"2017","journal-title":"Curr. Opin. Ophthalmol."},{"key":"ref_67","first-page":"CD006364","article-title":"Perioperative Antibiotics for Prevention of Acute Endophthalmitis after Cataract Surgery","volume":"2017","author":"Gower","year":"2017","journal-title":"Cochrane Database Syst. Rev."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.ejps.2018.02.017","article-title":"Improving Sustained Drug Delivery from Ophthalmic Lens Materials through the Control of Temperature and Time of Loading","volume":"117","author":"Topete","year":"2018","journal-title":"Eur. J. Pharm. Sci."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.ejpb.2017.08.006","article-title":"Surface Modification of an Intraocular Lens Material by Plasma-Assisted Grafting with 2-Hydroxyethyl Methacrylate (HEMA), for Controlled Release of Moxifloxacin","volume":"120","author":"Vieira","year":"2017","journal-title":"Eur. J. Pharm. Biopharm."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"1808","DOI":"10.1016\/j.jcrs.2019.07.016","article-title":"Moxifloxacin-Loaded Acrylic Intraocular Lenses: In Vitro and in Vivo Performance","volume":"45","author":"Filipe","year":"2019","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"120613","DOI":"10.1016\/j.ijpharm.2021.120613","article-title":"Intraocular Lenses as Drug Delivery Devices","volume":"602","author":"Topete","year":"2021","journal-title":"Int. J. Pharm."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1016\/j.ejpb.2012.07.007","article-title":"Antifouling Foldable Acrylic IOLs Loaded with Norfloxacin by Aqueous Soaking and by Supercritical Carbon Dioxide Technology","volume":"82","author":"Braga","year":"2012","journal-title":"Eur. J. Pharm. Biopharm."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1016\/j.supflu.2011.08.014","article-title":"Supercritical Impregnation of Intraocular Lenses","volume":"60","author":"Masmoudi","year":"2011","journal-title":"J. Supercrit. Fluids"},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"119247","DOI":"10.1016\/j.ijpharm.2020.119247","article-title":"Supercritical Loading of Gatifloxacin into Hydrophobic Foldable Intraocular Lenses\u2014Process Control and Optimization by Following in Situ CO2 Sorption and Polymer Swelling","volume":"581","author":"Ongkasin","year":"2020","journal-title":"Int. J. Pharm."},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1111\/j.1755-3768.2008.01419.x","article-title":"Intraocular Lens as a Drug Delivery System for Dexamethasone","volume":"88","author":"Kugelberg","year":"2010","journal-title":"Acta Ophthalmol."},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"1927","DOI":"10.3390\/ma4111927","article-title":"Drug-Eluting Intraocular Lenses","volume":"4","author":"Concheiro","year":"2011","journal-title":"Materials"},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"NP126","DOI":"10.1177\/11206721221086156","article-title":"Reversible Deposition of Inflammatory Cells on the Surface of an Intraocular Lens in a Patient with Uveitis: Case Report and Literature Review","volume":"33","author":"Jiang","year":"2023","journal-title":"Eur. J. Ophthalmol."},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1177\/1120672119891042","article-title":"Development of a Drug-Eluting Intraocular Lens to Deliver Epidermal Growth Factor Receptor Inhibitor Gefitinib for Posterior Capsule Opacification Prophylaxis","volume":"31","author":"Kassumeh","year":"2021","journal-title":"Eur. J. Ophthalmol."},{"key":"ref_79","first-page":"343","article-title":"Drug-Eluting Intraocular Lens with Sustained Bromfenac Release for Conquering Posterior Capsular Opacification","volume":"9","author":"Zhang","year":"2021","journal-title":"Bioact. Mater."},{"key":"ref_80","first-page":"30","article-title":"Thermo-Sensitive Poloxamer Based Antibacterial Anti-Inflammatory and Photothermal Conductive Multifunctional Hydrogel as Injectable, in Situ Curable and Adjustable Intraocular Lens","volume":"41","author":"Qin","year":"2024","journal-title":"Bioact. Mater."},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"793","DOI":"10.1039\/D0TB02530E","article-title":"Enhanced PCO Prevention of Drug Eluting IOLs via Endocytosis and Autophagy Effects of a PAMAM Dendrimer","volume":"9","author":"Qin","year":"2021","journal-title":"J. Mater. Chem. B"},{"key":"ref_82","doi-asserted-by":"crossref","unstructured":"Chen, S., Qin, C., Fang, Q., Duo, L., Wang, M., Deng, Z., Chen, H., and Lin, Q. (2022). Rapid and Economical Drug-Eluting IOL Preparation via Thermoresponsive Agarose Coating for Effective Posterior Capsular Opacification Prevention. Front. Bioeng. Biotechnol., 10.","DOI":"10.3389\/fbioe.2022.930540"},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"1448","DOI":"10.3341\/jkos.2011.52.12.1448","article-title":"Visual Outcome and Stability of Hydrogel Full-Optics Accommodative Intraocular Lens","volume":"52","author":"Kim","year":"2011","journal-title":"J. Korean Ophthalmol. Soc."},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1007\/s10792-019-01196-4","article-title":"Visual Acuity and Defocus Curves with Six Multifocal Intraocular Lenses","volume":"40","author":"Gil","year":"2020","journal-title":"Int. Ophthalmol."},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"629","DOI":"10.2147\/OPTH.S56135","article-title":"Safety and Effectiveness of a Single-Piece Hydrophobic Acrylic Intraocular Lens (enVista\u00ae)\u2013Results of a European and Asian-Pacific Study","volume":"8","author":"Heiner","year":"2014","journal-title":"Clin. Ophthalmol."},{"key":"ref_86","unstructured":"Kaur, K., and Gurnani, B. (2024). Contrast Sensitivity. StatPearls, StatPearls Publishing."},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"1684","DOI":"10.1016\/S0886-3350(03)00523-6","article-title":"Retinal Image Contrast and Functional Visual Performance with Aspheric, Silicone, and Acrylic Intraocular Lenses: Prospective Evaluation","volume":"29","author":"Kershner","year":"2003","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_88","doi-asserted-by":"crossref","unstructured":"Lee, Y.W., Choi, C.Y., Moon, K., Jeong, Y.J., An, S.I., Lee, J.M., Lee, J.H., and Seong, M.C. (2022). Clinical Outcomes of New Multifocal Intraocular Lenses with Hydroxyethyl Methacrylate and Comparative Results of Contrast Sensitivity, Objective Scatter, and Subjective Photic Phenomena. BMC Ophthalmol., 22.","DOI":"10.1186\/s12886-022-02600-x"},{"key":"ref_89","doi-asserted-by":"crossref","first-page":"2995","DOI":"10.1007\/s00417-021-05262-5","article-title":"Posterior Capsular Opacification Evaluation through Contrast Sensitivity Defocus Curves with Two Multifocal Intraocular Lenses of Similar Material","volume":"259","year":"2021","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"ref_90","doi-asserted-by":"crossref","first-page":"1199","DOI":"10.1016\/j.jcrs.2014.09.038","article-title":"Glistenings 9 Years after Phacoemulsification in Hydrophobic and Hydrophilic Acrylic Intraocular Lenses","volume":"41","author":"Chang","year":"2015","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_91","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.jcrs.2008.08.040","article-title":"Quantification of Glistenings in Intraocular Lenses Using Scheimpflug Photography","volume":"35","author":"Behndig","year":"2009","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_92","doi-asserted-by":"crossref","first-page":"1510","DOI":"10.1136\/bjophthalmol-2020-317124","article-title":"Impact of Intraocular Lens Characteristics on Intraocular Lens Dislocation after Cataract Surgery","volume":"105","author":"Pregartner","year":"2021","journal-title":"Br. J. Ophthalmol."},{"key":"ref_93","doi-asserted-by":"crossref","first-page":"989","DOI":"10.1007\/s40123-021-00390-x","article-title":"Relationship Between Postoperative Intraocular Lens Shift and Postoperative Refraction Change in Cataract Surgery Using Three Different Types of Intraocular Lenses","volume":"10","author":"Teshigawara","year":"2021","journal-title":"Ophthalmol. Ther."},{"key":"ref_94","doi-asserted-by":"crossref","first-page":"8653476","DOI":"10.1155\/2022\/8653476","article-title":"Real-World Cataract Surgery Complications and Secondary Interventions Incidence Rates: An Analysis of US Medicare Claims Database","volume":"2022","author":"Terveen","year":"2022","journal-title":"J. Ophthalmol."},{"key":"ref_95","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1097\/j.jcrs.0000000000000712","article-title":"Multicountry Clinical Outcomes of a New Nondiffractive Presbyopia-Correcting IOL","volume":"48","author":"Bala","year":"2022","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_96","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1007\/s12325-023-02698-5","article-title":"Association of Patient Satisfaction with Cataract Grading in Five Types of Multifocal IOLs","volume":"41","author":"Niazi","year":"2024","journal-title":"Adv. Ther."},{"key":"ref_97","doi-asserted-by":"crossref","first-page":"2297","DOI":"10.2147\/OPTH.S182943","article-title":"Patient-Reported Outcomes of Multifocal and Accommodating Intraocular Lenses: Analysis of 117 Patients 2\u201310 Years after Surgery","volume":"12","author":"Hovanesian","year":"2018","journal-title":"Clin. Ophthalmol."},{"key":"ref_98","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1038\/s41433-023-02633-6","article-title":"Attitudes and Understanding of Premium Intraocular Lenses in Cataract Surgery: A Public Health Sector Patient Survey","volume":"38","author":"Jameel","year":"2024","journal-title":"Eye"},{"key":"ref_99","doi-asserted-by":"crossref","first-page":"33","DOI":"10.3928\/1081597X-20221130-02","article-title":"Astigmatism Tolerance and Visual Outcomes After Bilateral Implantation of a Hybrid Continuous Transitional Focus IOL","volume":"39","author":"Pedrotti","year":"2023","journal-title":"J. Refract. Surg."},{"key":"ref_100","doi-asserted-by":"crossref","first-page":"39","DOI":"10.2174\/187221113804805829","article-title":"Coated with Nanomaterials Intraocular Lenses, Ophthalmic and Human Body Implantable Devices with High Catalytic Antioxidant Activities: A New Nanotechnology Strategy of Peroxidase Cellular Enzyme Mimics Increasing the Biocompatibility and Therapeutic Deployment of the Medical Prosthetic Device","volume":"7","author":"Babizhayev","year":"2013","journal-title":"Recent Pat. Drug Deliv. Formul."},{"key":"ref_101","doi-asserted-by":"crossref","first-page":"25158414221112356","DOI":"10.1177\/25158414221112356","article-title":"Nanotechnology-Based Formulations to Amplify Intraocular Bioavailability","volume":"14","author":"Kagkelaris","year":"2022","journal-title":"Ther. Adv. Ophthalmol."},{"key":"ref_102","doi-asserted-by":"crossref","first-page":"e2000447","DOI":"10.1002\/adhm.202000447","article-title":"Antibacterial Nanopillar Array for an Implantable Intraocular Lens","volume":"9","author":"Choi","year":"2020","journal-title":"Adv. Healthc. Mater."},{"key":"ref_103","doi-asserted-by":"crossref","first-page":"8541","DOI":"10.7150\/thno.46895","article-title":"Mild Temperature Photothermal Assisted Anti-Bacterial and Anti-Inflammatory Nanosystem for Synergistic Treatment of Post-Cataract Surgery Endophthalmitis","volume":"10","author":"Ye","year":"2020","journal-title":"Theranostics"},{"key":"ref_104","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1016\/j.jconrel.2020.09.014","article-title":"Biofilm Microenvironment Activated Supramolecular Nanoparticles for Enhanced Photodynamic Therapy of Bacterial Keratitis","volume":"327","author":"Han","year":"2020","journal-title":"J. Control. Release"},{"key":"ref_105","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.1166\/jbn.2024.3847","article-title":"Phacoemulsification Plus Intraocular Lens Implantation with Gold Nanoparticles for Complicated Cataract Secondary to Uveitis: Efficacy Analysis","volume":"20","author":"Kuang","year":"2024","journal-title":"J. Biomed. Nanotechnol."},{"key":"ref_106","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1007\/s40135-017-0150-3","article-title":"Refractive IOL Pipeline: Innovations, Predictions, and Needs","volume":"5","year":"2017","journal-title":"Curr. Ophthalmol. Rep."}],"container-title":["Journal of Functional Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2079-4983\/15\/12\/391\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T16:58:51Z","timestamp":1760115531000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2079-4983\/15\/12\/391"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,23]]},"references-count":106,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["jfb15120391"],"URL":"https:\/\/doi.org\/10.3390\/jfb15120391","relation":{},"ISSN":["2079-4983"],"issn-type":[{"value":"2079-4983","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,23]]}}}