{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T00:42:59Z","timestamp":1759970579333,"version":"build-2065373602"},"reference-count":21,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2025,1,29]],"date-time":"2025-01-29T00:00:00Z","timestamp":1738108800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100004506","name":"Cz\u0119stochowa University of Technology","doi-asserted-by":"publisher","award":["R-WIMII.SD.74.2024"],"award-info":[{"award-number":["R-WIMII.SD.74.2024"]}],"id":[{"id":"10.13039\/501100004506","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JFB"],"abstract":"<jats:p>The study is a metallographic analysis of commercial bone plates used for stabilizing long bones. The plates examined were delivered to the hospital in different years, and the course of treatment of patients with similar goniometric and anthropometric parameters varied dramatically. To determine the characteristics of displacement of bony fragments in the area of the simulated fracture and relate it to the strength parameters of the bone plate, experimental tests were carried out on composite femurs loaded according to the biomechanical loading model at known values of forces acting on the femoral head. In order to assess the influence of material parameters of the plate on the biomechanics of the bone\u2013bone plate system, microstructural and strength tests were performed, i.e., three-point bending tests, chemical composition and hardness assessments, as well as evaluation of the state of internal stresses in the tested materials. The research conducted allowed us to develop guidelines for companies producing bone fixations and orthopedic surgeons who use bone plates to stabilize bones after mechanical trauma, allowing the plates to be tailored to individual patient characteristics.<\/jats:p>","DOI":"10.3390\/jfb16020044","type":"journal-article","created":{"date-parts":[[2025,1,29]],"date-time":"2025-01-29T11:10:39Z","timestamp":1738149039000},"page":"44","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Impact of Strength Parameters and Material Structure of Bone Plates on Displacement of Bone Fragments in the Injured Area"],"prefix":"10.3390","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5910-0554","authenticated-orcid":false,"given":"Arkadiusz","family":"Szarek","sequence":"first","affiliation":[{"name":"Department of Technology and Automation, Faculty of Mechanical Engineering and Computer Science, Czestochowa University of Technology, 21 Armii Krajowej Av., 42-201 Czestochowa, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2093-4674","authenticated-orcid":false,"given":"Grzegorz","family":"Gola\u0144ski","sequence":"additional","affiliation":[{"name":"Faculty of Production Engineering and Materials Technology, Czestochowa University of Technology, 19 Armii Krajowej Av., 42-201 Czestochowa, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zbigniew","family":"Ba\u0142aga","sequence":"additional","affiliation":[{"name":"Faculty of Production Engineering and Materials Technology, Czestochowa University of Technology, 19 Armii Krajowej Av., 42-201 Czestochowa, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9351-7452","authenticated-orcid":false,"given":"Marcin","family":"Godzierz","sequence":"additional","affiliation":[{"name":"Centre of Polymer and Carbon Materials, Polish Academy of Science, M. Curie-Sk\u0142odowskiej Street 34, 41-819 Zabrze, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mariusz","family":"Radecki","sequence":"additional","affiliation":[{"name":"Orthopedics and Traumatic Surgery Department of NMP Voivodship Specialist Hospital in Czestochowa, Bialska Street 104\/118, 42-200 Czestochowa, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2025,1,29]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Zhang, N.Z., Liu, B.L., Luan, Y.C., Zhang, M., and Cheng, C.K. (2023). Failure analysis of a locking compression plate with asymmetric holes and polyaxial screws. J. Mech. Behav. Biomed. Mater., 138.","DOI":"10.1016\/j.jmbbm.2022.105645"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1177\/09544119241229157","article-title":"Biomechanical analysis of combi-holelocking compression plate duringfracture healing: A numerical study of screw configuration","volume":"238","author":"Li","year":"2024","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Wee, H., Staub, J., Koroneos, Z., Kunselman, A., Reid, J.S., and Lewis, G.S. (2024). Mechanics of dynamic compression plate application in fracture fixation. Clin. Biomech., 113.","DOI":"10.1016\/j.clinbiomech.2024.106209"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"095308","DOI":"10.1088\/2053-1591\/ac24f8","article-title":"Effects of bone-plate materials on the healing process of fractured tibia bone under time-varying conditions: A finite element analysis","volume":"8","author":"Tan","year":"2021","journal-title":"Mater. Res. Express"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1186\/s13018-020-01636-3","article-title":"J-bone graft with double locking plate: A symphony of mechanics and biology for atrophic distal femoral non-union with bone defect","volume":"15","author":"Lu","year":"2020","journal-title":"J. Orthop. Surg. Res."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Zhan, S., Jiang, D., Hu, Q., Wang, Q., Wang, M., Feng, C., Jia, W., Hu, H., and Niu, W. (2024). Single-plane osteotomy model is inaccurate for evaluating the optimal strategy in treating vertical femoral neck fractures: A finite element analysis. Comput. Methods Programs Biomed., 245.","DOI":"10.1016\/j.cmpb.2024.108036"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1080\/08941939.2019.1567875","article-title":"Plating system design determines mechanical environment in long bone mid-shaft fractures: A finite element analysis","volume":"33","author":"Wang","year":"2020","journal-title":"J. Investig. Surg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"e26302","DOI":"10.1016\/j.heliyon.2024.e26302","article-title":"Investigation of dynamic hip plate screw systems in different lengths with finite element analysis","volume":"10","year":"2024","journal-title":"Heliyon"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Kim, S.M. (2024). Study on the characteristics of increased mechanical stiffness according to changes in LCP shape to reinforce clavicle fractures. Sci. Rep., 14.","DOI":"10.1038\/s41598-024-56588-z"},{"key":"ref_10","unstructured":"Nowakowski, A., and Mazutek, T. (2024). Orthopedics and Traumatology. Educational Project of the Polish Orthopedic and Traumatological Society, Exemplum Scientific Publishing House."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"750","DOI":"10.5455\/medscience.2021.12.409","article-title":"Evaluation of the Results of the Proximal Femoral Nail Surgery for Intertrochanteric Femoral Fractures","volume":"11","author":"Ulusoy","year":"2018","journal-title":"Med. Sci."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/j.injury.2012.10.011","article-title":"An unusual failure of a sliding hip screw in the immediate post-operative period","volume":"44","author":"Arastu","year":"2013","journal-title":"Inj. Extra"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1355","DOI":"10.1016\/j.injury.2005.04.014","article-title":"Two-hole side-plate DHS in the treatment of intertrochanteric fracture: Results and complications","volume":"36","author":"Laohapoonrungsee","year":"2005","journal-title":"Injury"},{"key":"ref_14","unstructured":"R\u00fcedi, T.P., Buckley, R.E., and Moran, C.G. (2014). AO Basics of Fracture Treatment, MediPage."},{"key":"ref_15","unstructured":"Szarek, A. (2015). Biomechanical and Biomaterial Determinants of Aseptic Loosening of Human Hip Joint Endoprostheses, Czestochowa University of Technology Publishing House."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Pauwels, F., Maquet, P.G., and Furlong, R. (1980). Biomechanics of the locomotor apparatus. Contributions on the Functional Anatomy of the Locomotor Apparatus, Springer. [1st ed.].","DOI":"10.1007\/978-3-642-67138-8"},{"key":"ref_17","unstructured":"(2009). Non-Destructive Testing\u2014Test Method for Residual Stress Analysis by X-ray Diffraction (Standard No. EN 15305:2009)."},{"key":"ref_18","unstructured":"Jessen, C.Q. (2011). Stainless Steel and Corrosion, Damstahl."},{"key":"ref_19","unstructured":"(2024). Steels\u2014Micrographic Determination of the Apparent Grain Size (Standard No. ISO 643:2024)."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1002\/srin.200806146","article-title":"Some strengthening methods for austenitic stainless steels","volume":"79","author":"Karjalainen","year":"2008","journal-title":"Steel Res."},{"key":"ref_21","unstructured":"(2024). Implants for Surgery\u2014Metallic Materials. Part 1: Wrought Stainless Steel (Standard No. ISO 5832-1:2024)."}],"container-title":["Journal of Functional Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2079-4983\/16\/2\/44\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T10:38:31Z","timestamp":1759919911000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2079-4983\/16\/2\/44"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,29]]},"references-count":21,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2025,2]]}},"alternative-id":["jfb16020044"],"URL":"https:\/\/doi.org\/10.3390\/jfb16020044","relation":{},"ISSN":["2079-4983"],"issn-type":[{"type":"electronic","value":"2079-4983"}],"subject":[],"published":{"date-parts":[[2025,1,29]]}}}