{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T05:15:41Z","timestamp":1782796541896,"version":"3.54.5"},"reference-count":30,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T00:00:00Z","timestamp":1754092800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100005774","name":"Universitat de Barcelona","doi-asserted-by":"publisher","award":["C\u00e0tedra UB-Avinent"],"award-info":[{"award-number":["C\u00e0tedra UB-Avinent"]}],"id":[{"id":"10.13039\/501100005774","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JFB"],"abstract":"<jats:p>The aim of this study was to evaluate the impact of autoclaving on the dimensional stability of surgical guides (SGs) for aesthetic crown lengthening (ACL) using different resins\/printing methods. Fifty SGs for ACL were printed using five different resin\/printer combinations (FL, SR, ND, KS and VC). All the SGs were scanned before (T0) and after (T1) sterilization. Autoclaving was conducted at 134 \u00b0C during 4 min. The STL files of each SG at T0 and T1 were compared with the original design (TR). Dimensional stability was measured using trueness and precision. Deviations from TR to T1 were calculated in the three space axes and by measuring the area between three reference landmarks. At T0, the FL group showed the best trueness and precision, while the SR group performed significantly worse than the other groups. At T1, all the groups except VC exhibited significant dimensional alterations compared with T0. Also, VC showed the best trueness and precision values. All the groups had a significant deviation in at least one space axis, while only the SR group exhibited significant variations from T1 to TR in the area between the reference landmarks. Most of the evaluated resin\/3D printer combinations suffered significant dimensional alterations after autoclaving.<\/jats:p>","DOI":"10.3390\/jfb16080284","type":"journal-article","created":{"date-parts":[[2025,8,4]],"date-time":"2025-08-04T11:54:51Z","timestamp":1754308491000},"page":"284","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Impact of Autoclaving on the Dimensional Stability of 3D-Printed Surgical Guides for Aesthetic Crown Lengthening"],"prefix":"10.3390","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0782-9896","authenticated-orcid":false,"given":"Albert","family":"Gonz\u00e1lez-Barnadas","sequence":"first","affiliation":[{"name":"Department of Dentistry, Faculty of Medicine and Health Sciences, Universitat de Barcelona, 08907 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-2533-6738","authenticated-orcid":false,"given":"Anna","family":"Ribas-Garcia","sequence":"additional","affiliation":[{"name":"Department of Dentistry, Faculty of Medicine and Health Sciences, Universitat de Barcelona, 08907 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2369-0326","authenticated-orcid":false,"given":"Adri\u00e0","family":"Jorba-Garc\u00eda","sequence":"additional","affiliation":[{"name":"Department of Dentistry, Faculty of Medicine and Health Sciences, Universitat de Barcelona, 08907 Barcelona, Spain"},{"name":"Dental and Maxillofacial Pathology and Therapeutics Research Group, IDIBELL Research Institute, 08908 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2122-6530","authenticated-orcid":false,"given":"Rui","family":"Figueiredo","sequence":"additional","affiliation":[{"name":"Department of Dentistry, Faculty of Medicine and Health Sciences, Universitat de Barcelona, 08907 Barcelona, Spain"},{"name":"Dental and Maxillofacial Pathology and Therapeutics Research Group, IDIBELL Research Institute, 08908 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9669-3187","authenticated-orcid":false,"given":"Eduard","family":"Valmaseda-Castell\u00f3n","sequence":"additional","affiliation":[{"name":"Department of Dentistry, Faculty of Medicine and Health Sciences, Universitat de Barcelona, 08907 Barcelona, Spain"},{"name":"Dental and Maxillofacial Pathology and Therapeutics Research Group, IDIBELL Research Institute, 08908 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9991-2226","authenticated-orcid":false,"given":"Octavi","family":"Camps-Font","sequence":"additional","affiliation":[{"name":"Department of Dentistry, Faculty of Medicine and Health Sciences, Universitat de Barcelona, 08907 Barcelona, Spain"},{"name":"Dental and Maxillofacial Pathology and Therapeutics Research Group, IDIBELL Research Institute, 08908 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,8,2]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Khaohoen, A., Powcharoen, W., Sornsuwan, T., Chaijareenont, P., Rungsiyakull, C., and Rungsiyakull, P. (2024). Accuracy of implant placement with computer-aided static, dynamic, and robot-assisted surgery: A systematic review and meta-analysis of clinical trials. BMC Oral. Health, 24.","DOI":"10.1186\/s12903-024-04033-y"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2479","DOI":"10.1007\/s00784-021-03833-8","article-title":"Accuracy assessment of dynamic computer-aided implant placement: A systematic review and meta-analysis","volume":"25","author":"Figueiredo","year":"2021","journal-title":"Clin. Oral. Investig."},{"key":"ref_3","first-page":"339","article-title":"Computer-guided surgical exposure of palatally displaced canines: A technical note","volume":"26","author":"Vilarrasa","year":"2023","journal-title":"Int. J. Comput. Dent."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1515","DOI":"10.1016\/j.joen.2020.06.017","article-title":"Fully Guided Tooth Autotransplantation Using a Multidrilling Axis Surgical Stent: Proof of Concept","volume":"46","author":"Llaquet","year":"2020","journal-title":"J. Endod."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Gibreal, O., Al-modallal, Y., Mahmoud, G., and Gibreal, A. (2023). The efficacy and accuracy of 3D-guided orthodontic piezocision: A randomized controlled trial. BMC Oral. Health, 23.","DOI":"10.1186\/s12903-023-02902-6"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1111\/jerd.12920","article-title":"The crown lengthening double guide and the digital Perio analysis","volume":"35","author":"Coachman","year":"2023","journal-title":"J. Esthet. Restor. Dent."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1016\/j.prosdent.2017.04.018","article-title":"A digitally guided dual technique for both gingival and bone resection during crown lengthening surgery","volume":"119","author":"Liu","year":"2018","journal-title":"J. Prosthet. Dent."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1596","DOI":"10.1111\/jerd.13269","article-title":"Digital resources for surgical and restorative treatment of excessive gingival display in one session","volume":"36","author":"Giordani","year":"2024","journal-title":"J. Esthet. Restor. Dent."},{"key":"ref_9","first-page":"254","article-title":"Double guide concept: A new digital paradigm for the treatment of altered passive eruption in patients with high esthetic expectations","volume":"17","author":"Longo","year":"2022","journal-title":"Int. J. Esthet. Dent."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Borham, E., Abuel-Ela, H.A., Mohamed, I.S., and Fouad, Y.A. (2024). Treatment of excessive gingival display using conventional esthetic crown lengthening versus computer guided esthetic crown lengthening: (a randomized clinical trial). BMC Oral. Health, 24.","DOI":"10.1186\/s12903-024-04080-5"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/j.prosdent.2019.06.027","article-title":"Full digital workflow for crown lengthening by using a single surgical guide","volume":"124","author":"Passos","year":"2020","journal-title":"J. Prosthet. Dent."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1016\/j.prosdent.2020.09.041","article-title":"Periodontal plastic surgery for esthetic crown lengthening by using data merging and a CAD-CAM surgical guide","volume":"127","author":"Cornejo","year":"2022","journal-title":"J. Prosthet. Dent."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1589","DOI":"10.1007\/s00784-022-04780-8","article-title":"Digital planning and guided dual technique in esthetic crown lengthening: A randomized controlled clinical trial","volume":"27","author":"Carrera","year":"2023","journal-title":"Clin. Oral. Investig."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1284","DOI":"10.1111\/jerd.13405","article-title":"Accuracy of Guided Dual Technique in Esthetic Crown Lengthening: A Prospective Case-Series Study","volume":"37","author":"Vilarrasa","year":"2025","journal-title":"J. Esthet. Restor. Dent."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1111\/jopr.13161","article-title":"Comparison of the Accuracy of Implant Position Using Surgical Guides Fabricated by Additive and Subtractive Techniques","volume":"29","author":"Henprasert","year":"2020","journal-title":"J. Prosthodont."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1111\/jopr.13477","article-title":"Additive Manufacturing Technologies: Current Status and Future Perspectives","volume":"31","author":"Alammar","year":"2022","journal-title":"J. Prosthodont."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1007\/s10266-019-00441-7","article-title":"An update on applications of 3D printing technologies used for processing polymers used in implant dentistry","volume":"108","author":"Sadeghpour","year":"2020","journal-title":"Odontology"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"103909","DOI":"10.1016\/j.jdent.2021.103909","article-title":"Accuracy of commercial 3D printers for the fabrication of surgical guides in dental implantology","volume":"117","author":"Cade","year":"2022","journal-title":"J. Dent."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"105226","DOI":"10.1016\/j.jdent.2024.105226","article-title":"Accuracy of surgical guides manufactured with four different 3D printers. A comparative in vitro study","volume":"148","author":"Berrendero","year":"2024","journal-title":"J. Dent."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1111\/clr.14362","article-title":"Effect of Storage Conditions and Time on the Dimensional Stability of 3D Printed Surgical Guides: An In Vitro Study","volume":"36","author":"Ntovas","year":"2024","journal-title":"Clin. Oral. Implant. Res."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1111\/cid.13350","article-title":"Effects of sterilization and disinfection methods on digitally designed surgical implant guide accuracy: An in vitro study","volume":"26","author":"Li","year":"2024","journal-title":"Clin. Implant. Dent. Relat. Res."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Lo Russo, L., Guida, L., Mariani, P., Ronsivalle, V., Gallo, C., Cicci\u00f9, M., and Laino, L. (2023). Effect of Fabrication Technology on the Accuracy of Surgical Guides for Dental-Implant Surgery. Bioengineering, 10.","DOI":"10.3390\/bioengineering10070875"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Yazigi, C., Chaar, M.S., Busch, R., and Kern, M. (2023). The Effect of Sterilization on the Accuracy and Fit of 3D-Printed Surgical Guides. Materials, 16.","DOI":"10.3390\/ma16155305"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1097\/ID.0000000000000908","article-title":"Effect of Steam Heat Sterilization on the Accuracy of 3D Printed Surgical Guides","volume":"28","author":"Marei","year":"2019","journal-title":"Implant. Dent."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"821","DOI":"10.1111\/clr.14158","article-title":"Autoclaving-induced dimensional changes of three-dimensional printed surgical guides: An in vitro study","volume":"35","author":"David","year":"2024","journal-title":"Clin. Oral. Implant. Res."},{"key":"ref_26","unstructured":"(2023). Accuracy (Trueness and Precision) of Measurement Methods and Results\u2014Part 1: General Principles and Definitions (Standard No. ISO 5725-1:2023). Available online: https:\/\/www.iso.org\/obp\/ui\/es\/#iso:std:iso:5725:-1:ed-2:v1:en."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"T\u00f6r\u00f6k, G., Gombocz, P., Bogn\u00e1r, E., Nagy, P., Dinya, E., Kisp\u00e9lyi, B., and Hermann, P. (2020). Effects of disinfection and sterilization on the dimensional changes and mechanical properties of 3D printed surgical guides for implant therapy\u2014Pilot study. BMC Oral. Health, 20.","DOI":"10.1186\/s12903-020-1005-0"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"e70111","DOI":"10.1002\/cre2.70111","article-title":"Impact of Autoclaving on the Dimensional Stability of 3D-Printed Guides for Orthodontic Mini-Implant Insertion\u2014An In Vitro Study","volume":"11","author":"David","year":"2025","journal-title":"Clin. Exp. Dent. Res."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Pranno, N., Franchina, A., De Angelis, F., Boss\u00f9, M., Salucci, A., Brauner, E., Cristalli, M.P., and La Monaca, G. (2025). The Effects of Light Crystal Display 3D Printers, Storage Time and Steam Sterilization on the Dimensional Stability of a Photopolymer Resin for Surgical Guides: An In Vitro Study. Materials, 18.","DOI":"10.3390\/ma18030474"},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Vara, R., Lin, W., Low, J.K., Smith, D., Grimm, A., Calvert, G., Tadakamadla, S.K., Alifui-Segbaya, F., and Ahmed, K.E. (2023). Assessing the Impact of Resin Type, Post-Processing Technique, and Arch Location on the Trueness and Precision of 3D-Printed Full-Arch Implant Surgical Guides. Appl. Sci., 13.","DOI":"10.3390\/app13042491"}],"container-title":["Journal of Functional Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2079-4983\/16\/8\/284\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T18:21:44Z","timestamp":1760034104000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2079-4983\/16\/8\/284"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,2]]},"references-count":30,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2025,8]]}},"alternative-id":["jfb16080284"],"URL":"https:\/\/doi.org\/10.3390\/jfb16080284","relation":{},"ISSN":["2079-4983"],"issn-type":[{"value":"2079-4983","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,2]]}}}