{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T12:12:56Z","timestamp":1785413576934,"version":"3.56.0"},"reference-count":37,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2026,6,28]],"date-time":"2026-06-28T00:00:00Z","timestamp":1782604800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100009687","name":"Wroclaw Medical University","doi-asserted-by":"publisher","award":["SUBZ.Z516.26.003"],"award-info":[{"award-number":["SUBZ.Z516.26.003"]}],"id":[{"id":"10.13039\/501100009687","id-type":"DOI","asserted-by":"publisher"}]},{"award":["SUBZ.Z516.26.003"],"award-info":[{"award-number":["SUBZ.Z516.26.003"]}],"id":[{"id":"https:\/\/ror.org\/01qpw1b93","id-type":"ROR","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JFB"],"abstract":"<jats:p>Coronary drug-eluting stents (DESs) are the current clinical standard, yet delayed endothelialization remains a critical challenge. Graphene-based coatings have emerged as promising cardiovascular biomaterials due to their favorable hemocompatibility and ability to support endothelial cell growth. In this study, we evaluated the in vivo performance of graphene-coated stents (GCSs) compared with commercial sirolimus-eluting stents in a Polish White swine model (n = 10). Stents were implanted into major coronary branches, with follow-up at 30 and 90 days using quantitative coronary angiography (QCA), optical coherence tomography (OCT), and cryogenic scanning electron microscopy (cryo-SEM). No systemic toxicity, mortality, thrombotic events, or ischemic complications were observed during the study period. QCA demonstrated no significant differences in percent diameter stenosis between GCSs and DESs at either 30 days (12.3 \u00b1 6.1% vs. 8.6 \u00b1 5.8%, p = 0.2782) or 90 days (18.3 \u00b1 10.5% vs. 9.6 \u00b1 6.6%, p = 0.1074). OCT analysis confirmed comparable lumen and neointimal parameters between groups, while demonstrating a favorable, although non-significant, trend toward a lower percentage of uncovered struts in GCSs. Cryo-SEM imaging demonstrated stable tissue integration and a preserved healing response surrounding GCSs. Collectively, these findings indicate that GCSs are safe and biocompatible and demonstrate mid-term vascular performance comparable to clinically used DES platforms. The presented results support further investigation of graphene-based coatings as potential surface-modification strategies for coronary stents.<\/jats:p>","DOI":"10.3390\/jfb17070313","type":"journal-article","created":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T05:49:33Z","timestamp":1782712173000},"page":"313","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of Graphene as a Novel Bioactive Stent Coating: Comparative Performance and Vascular Response in Porcine Coronary Arteries"],"prefix":"10.3390","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2761-7580","authenticated-orcid":false,"given":"Jacek","family":"Arkowski","sequence":"first","affiliation":[{"name":"Pre-Clinical Research Center, Wroc\u0142aw Medical University, K. Marcinkowskiego 1, 50-368 Wroc\u0142aw, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9125-7594","authenticated-orcid":false,"given":"Przemys\u0142aw","family":"Sare\u0142o","sequence":"additional","affiliation":[{"name":"Pre-Clinical Research Center, Wroc\u0142aw Medical University, K. Marcinkowskiego 1, 50-368 Wroc\u0142aw, Poland"},{"name":"Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wroc\u0142aw University of Science and Technology, Wybrze\u017ce S. Wyspia\u0144skiego 27, 50-370 Wroc\u0142aw, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2298-9713","authenticated-orcid":false,"given":"Urszula","family":"Pas\u0142awska","sequence":"additional","affiliation":[{"name":"Department of Diagnostics and Clinical Sciences, Faculty of Veterinary Medicine, University of Agriculture in Krak\u00f3w, Aleja A. Mickiewicza 21, 31-120 Krak\u00f3w, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9607-2919","authenticated-orcid":false,"given":"Robert","family":"Pas\u0142awski","sequence":"additional","affiliation":[{"name":"Department of Diagnostics and Clinical Sciences, Faculty of Veterinary Medicine, University of Agriculture in Krak\u00f3w, Aleja A. Mickiewicza 21, 31-120 Krak\u00f3w, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Magdalena","family":"Wawrzy\u0144ska","sequence":"additional","affiliation":[{"name":"Pre-Clinical Research Center, Wroc\u0142aw Medical University, K. Marcinkowskiego 1, 50-368 Wroc\u0142aw, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,6,28]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"102836","DOI":"10.1016\/j.cpcardiol.2024.102836","article-title":"Innovations in interventional cardiology: Pioneering techniques for a new era","volume":"49","author":"Hamayun","year":"2024","journal-title":"Curr. Probl. Cardiol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"169","DOI":"10.2991\/jegh.k.201217.001","article-title":"Epidemiology and the Magnitude of Coronary Artery Disease and Acute Coronary Syndrome: A Narrative Review","volume":"11","author":"Ralapanawa","year":"2021","journal-title":"J. Epidemiol. Glob. Health"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1186\/s13019-022-01812-y","article-title":"Evolutionary perspective of drug eluting stents: From thick polymer to polymer free approach","volume":"17","author":"Hassan","year":"2022","journal-title":"J. Cardiothorac. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2000920","DOI":"10.1002\/adhm.202000920","article-title":"Surface Engineering of Cardiovascular Devices for Improved Hemocompatibility and Rapid Endothelialization","volume":"9","author":"Zhao","year":"2020","journal-title":"Adv. Healthc. Mater."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1016\/j.biomaterials.2016.06.042","article-title":"Biomimetic cardiovascular stents for in vivo re-endothelialization","volume":"103","author":"Liang","year":"2016","journal-title":"Biomaterials"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Strohbach, A., and Busch, R. (2021). Predicting the In Vivo Performance of Cardiovascular Biomaterials: Current Approaches In Vitro Evaluation of Blood\u2013Biomaterial Interactions. Int. J. Mol. Sci., 22.","DOI":"10.3390\/ijms222111390"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"021508","DOI":"10.1063\/5.0037298","article-title":"Surface engineering at the nanoscale: A way forward to improve coronary stent efficacy","volume":"5","author":"Cherian","year":"2021","journal-title":"APL Bioeng."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Raikar, A.S., Priya, S., Bhilegaonkar, S.P., Somnache, S.N., and Kalaskar, D.M. (2023). Surface Engineering of Bioactive Coatings for Improved Stent Hemocompatibility: A Comprehensive Review. Materials, 16.","DOI":"10.20944\/preprints202310.0470.v1"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"e007311","DOI":"10.1161\/CIRCINTERVENTIONS.118.007311","article-title":"Safety and Efficacy of Polymer-Free Drug-Eluting Stents","volume":"12","author":"Chiarito","year":"2019","journal-title":"Circ. Cardiovasc. Interv."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1002\/jbm.b.34380","article-title":"Functionalization with a VEGFR2-binding antibody fragment leads to enhanced endothelialization of a cardiovascular stent in vitro and in vivo","volume":"108","author":"Kraskiewicz","year":"2020","journal-title":"J. Biomed. Mater. Res. B Appl. Biomater."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1016\/j.bbe.2023.02.001","article-title":"In vitro examinations of the anti-inflammatory interleukin functionalized polydopamine based biomaterial as a potential coating for cardiovascular stents","volume":"43","author":"Podbielska","year":"2023","journal-title":"Biocybern. Biomed. Eng."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1016\/j.colsurfb.2018.11.061","article-title":"Functionalized CD133 antibody coated stent surface simultaneously promotes EPCs adhesion and inhibits smooth muscle cell proliferation\u2013A novel approach to prevent in-stent restenosis","volume":"174","author":"Duda","year":"2019","journal-title":"Colloids Surf. B Biointerfaces"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/j.actbio.2020.05.011","article-title":"Late Endothelial Progenitor Cell-Capture Stents with CD146 Antibody and Nanostructure Reduce In-Stent Restenosis and Thrombosis","volume":"111","author":"Park","year":"2020","journal-title":"Acta Biomater."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Benjamin, S.R., and J\u00fanior, E.J.M.R. (2024). Carbon-based nanomaterials as antimicrobial nanocoatings for medical devices and implants. Next-Generation Antimicrobial Nanocoatings for Medical Devices and Implants, Woodhead Publishing.","DOI":"10.1016\/B978-0-323-95756-4.00012-9"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1660","DOI":"10.1039\/C2RA23073A","article-title":"Graphene coatings for enhanced hemo-compatibility of nitinol stents","volume":"3","author":"Podila","year":"2013","journal-title":"RSC Adv."},{"key":"ref_16","first-page":"2758347","article-title":"Biocompatible Carbon-Based Coating as Potential Endovascular Material for Stent Surface","volume":"2018","author":"Arkowski","year":"2018","journal-title":"Biomed Res. Int."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"708","DOI":"10.1016\/j.msec.2018.11.084","article-title":"Innovative coating based on graphene and their decorated nanoparticles for medical stent applications","volume":"96","author":"ElSawy","year":"2019","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Yang, M.-C., Tsou, H.-M., Hsiao, Y.-S., Cheng, Y.-W., Liu, C.-C., Huang, L.-Y., Peng, X.-Y., Liu, T.-Y., Yung, M.-C., and Hsu, C.-C. (2019). Electrochemical Polymerization of PEDOT\u2013Graphene Oxide\u2013Heparin Composite Coating for Anti-Fouling and Anti-Clotting of Cardiovascular Stents. Polymers, 11.","DOI":"10.3390\/polym11091520"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/j.msec.2016.03.001","article-title":"Anticoagulation and endothelial cell behaviors of heparin-loaded graphene oxide coating on titanium surface","volume":"63","author":"Pan","year":"2016","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1093\/rb\/rbz010","article-title":"Inhibition of in-stent restenosis after graphene oxide double-layer drug coating with good biocompatibility","volume":"6","author":"Ge","year":"2019","journal-title":"Regen. Biomater."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Wasyluk, \u0141., Hreniak, D., Boiko, V., Sobieszcza\u0144ska, B., Bologna, E., Zingales, M., Pas\u0142awski, R., Arkowski, J., Sare\u0142o, P., and Wawrzy\u0144ska, M. (2024). Functional Mechanical Behavior and Biocompatible Characteristics of Graphene-Coated Cardiovascular Stents. Int. J. Mol. Sci., 25.","DOI":"10.3390\/ijms252413345"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1111\/jcmm.13936","article-title":"The effects of stenting on coronary endothelium from a molecular biological view: Time for improvement?","volume":"23","author":"Cornelissen","year":"2019","journal-title":"J. Cell. Mol. Med."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Gherasie, F.-A., Valentin, C., and Busnatu, S.-S. (2023). Is There an Advantage of Ultrathin-Strut Drug-Eluting Stents over Second- and Third-Generation Drug-Eluting Stents?. J. Pers. Med., 13.","DOI":"10.3390\/jpm13050753"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Shen, Y., Yu, X., Cui, J., Yu, F., Liu, M., Chen, Y., Wu, J., Sun, B., and Mo, X. (2022). Development of Biodegradable Polymeric Stents for the Treatment of Cardiovascular Diseases. Biomolecules, 12.","DOI":"10.3390\/biom12091245"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.carrev.2022.05.028","article-title":"Magmaris Resorbable Magnesium Scaffold Versus Conventional Drug-Eluting Stent in ST-Segment Elevation Myocardial Infarction: 1-Year Results of a Propensity-Score-Matching Comparison","volume":"43","author":"Xaplanteris","year":"2022","journal-title":"Cardiovasc. Revasc. Med."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"2479","DOI":"10.1016\/S0140-6736(16)32050-5","article-title":"Comparison of an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent for the treatment of coronary artery stenosis (ABSORB II): A 3 year, randomised, controlled, single-blind, multicentre clinical trial","volume":"388","author":"Serruys","year":"2016","journal-title":"Lancet"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1504","DOI":"10.1016\/S0140-6736(20)32173-5","article-title":"Long-term efficacy and safety of drug-coated balloons versus drug-eluting stents for small coronary artery disease (BASKET-SMALL 2): 3-year follow-up of a randomised, non-inferiority trial","volume":"396","author":"Jeger","year":"2020","journal-title":"Lancet"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"e082945","DOI":"10.1136\/bmj-2024-082945","article-title":"Stepwise dual antiplatelet therapy de-escalation in patients after drug coated balloon angioplasty (REC-CAGEFREE II): Multicentre, randomised, open label, assessor blind, non-inferiority trial","volume":"388","author":"Gao","year":"2025","journal-title":"BMJ"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1170","DOI":"10.1016\/j.jacc.2025.07.049","article-title":"Indications for Use of Drug-Coated Balloons in Coronary Intervention: Academic Research Consortium Position Statement","volume":"86","author":"Fezzi","year":"2025","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_30","first-page":"257","article-title":"Synergistic fusion of CD47, VE-cadherin and mussel adhesion protein promotes endothelialization and suppresses inflammation in vascular stents","volume":"55","author":"Yan","year":"2025","journal-title":"Bioact. Mater."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1431","DOI":"10.1007\/s11517-020-02166-0","article-title":"Characterization of carotid endothelial cell proliferation on Au, Au\/GO, and Au\/rGO surfaces by electrical impedance spectroscopy","volume":"58","author":"Can","year":"2020","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1186\/s40824-020-0182-x","article-title":"Mechanical and physio-biological properties of peptide-coated stent for re-endothelialization","volume":"24","author":"Bae","year":"2020","journal-title":"Biomater. Res."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"132487","DOI":"10.1016\/j.ijbiomac.2024.132487","article-title":"A CO-releasing coating based on carboxymethyl chitosan-functionalized graphene oxide for improving the anticorrosion and biocompatibility of magnesium alloy stent materials","volume":"271","author":"Pan","year":"2024","journal-title":"Int. J. Biol. Macromol."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"031405","DOI":"10.1063\/5.0192379","article-title":"Synthesis and characterization of amine-functionalized graphene as a nitric oxide-generating coating for vascular stents","volume":"11","author":"Tabish","year":"2024","journal-title":"Appl. Phys. Rev."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1161\/CIRCINTERVENTIONS.113.000990","article-title":"Long-term safety of an everolimus-eluting bioresorbable vascular scaffold and the cobalt-chromium XIENCE V stent in a porcine coronary artery model","volume":"7","author":"Otsuka","year":"2014","journal-title":"Circ. Cardiovasc. Interv."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"115","DOI":"10.5603\/CJ.a2018.0095","article-title":"Two-year longitudinal evaluation of a second-generation thin-strut sirolimus-eluting bioresorbable coronary scaffold with hybrid cell design in porcine coronary arteries","volume":"27","author":"Gasior","year":"2020","journal-title":"Cardiol. J."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1016\/j.jcin.2012.12.131","article-title":"Intracoronary Optical Coherence Tomography and Histology of Overlapping Everolimus-Eluting Bioresorbable Vascular Scaffolds in a Porcine Coronary Artery Model: The Potential Implications for Clinical Practice","volume":"6","author":"Farooq","year":"2013","journal-title":"JACC Cardiovasc. Interv."}],"container-title":["Journal of Functional Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2079-4983\/17\/7\/313\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T06:55:34Z","timestamp":1782716134000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2079-4983\/17\/7\/313"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,28]]},"references-count":37,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2026,7]]}},"alternative-id":["jfb17070313"],"URL":"https:\/\/doi.org\/10.3390\/jfb17070313","relation":{},"ISSN":["2079-4983"],"issn-type":[{"value":"2079-4983","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,28]]}}}