{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T05:07:24Z","timestamp":1788930444018,"version":"build-2803163510"},"reference-count":38,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T00:00:00Z","timestamp":1788739200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Funct. Biomater.","JFB"],"abstract":"<jats:p>Patient-specific Ti\u20136Al\u20134V fixation systems are increasingly used to stabilise the maxilla following segmental Le Fort I osteotomy; however, the biomechanical responses of complete locking and non-locking patient-specific fixation configurations remain insufficiently characterised. In this study, two patient-specific plate designs (a standard design and a reduced, minimally invasive design) were analysed by linear-elastic finite element analysis, each with locking and non-locking screws. Because they were developed for different indications and evaluated in distinct patient-specific anatomical models, between-model comparisons were considered descriptive. Vertical forces of 97.6, 206.9, and 257.0 N were applied bilaterally to the incisor and premolar regions, and the equivalent von Mises stress and total displacement were evaluated in the bone, plates, and screws. All results scaled linearly with load. Within the standard model, the locking configuration exhibited slightly greater bone, plate, and screw displacement than the corresponding non-locking configuration. Within the reduced model, it exhibited lower maximum bone, plate, and screw displacement by 16.4%, 19.2%, and 16.3%, respectively. Solver-reported local stress maxima were concentrated at the screw-head\/plate-hole transition; because these isolated peaks were contact- and mesh-sensitive, they were not used to quantify relative screw loading or predict yielding. The modelled locking and non-locking fixation configurations therefore exhibited different, model-dependent displacement patterns. Further controlled simulations and experimental validation are required to determine the clinical relevance of these findings.<\/jats:p>","DOI":"10.3390\/jfb17090454","type":"journal-article","created":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T10:30:46Z","timestamp":1788777046000},"page":"454","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Biomechanical Evaluation of Patient-Specific Titanium Fixation Systems for Segmental Le Fort I Osteotomy: A Finite Element Analysis"],"prefix":"10.3390","volume":"17","author":[{"given":"Neculai","family":"Onic\u0103","sequence":"first","affiliation":[{"name":"Grigore T. Popa University of Medicine and Pharmacy Iasi, 700115 Iasi, Romania"},{"name":"VEA MFG L.T.D., Bratuleni, 707307 Iasi, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8932-6784","authenticated-orcid":false,"given":"Elena-Raluca","family":"Baciu","sequence":"additional","affiliation":[{"name":"Grigore T. Popa University of Medicine and Pharmacy Iasi, 700115 Iasi, Romania"},{"name":"VEA MFG L.T.D., Bratuleni, 707307 Iasi, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cezara Andreea","family":"Onic\u0103","sequence":"additional","affiliation":[{"name":"Grigore T. Popa University of Medicine and Pharmacy Iasi, 700115 Iasi, Romania"},{"name":"VEA MFG L.T.D., Bratuleni, 707307 Iasi, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9678-5708","authenticated-orcid":false,"given":"Florin-Emilian","family":"\u021aurcanu","sequence":"additional","affiliation":[{"name":"Technical University \u201cGheorghe Asachi\u201d of Iasi, 700050 Iasi, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-6591-0681","authenticated-orcid":false,"given":"Geta-Mirela","family":"Ispas","sequence":"additional","affiliation":[{"name":"\u201cIon Ionescu de la Brad\u201d Iasi University of Life Sciences, 700490 Iasi, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vlad Nicolae","family":"Arsenoaia","sequence":"additional","affiliation":[{"name":"\u201cIon Ionescu de la Brad\u201d Iasi University of Life Sciences, 700490 Iasi, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-2598-0874","authenticated-orcid":false,"given":"Loredana","family":"Golovcencu","sequence":"additional","affiliation":[{"name":"Grigore T. Popa University of Medicine and Pharmacy Iasi, 700115 Iasi, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4526-3878","authenticated-orcid":false,"given":"Alice","family":"Murariu","sequence":"additional","affiliation":[{"name":"Grigore T. Popa University of Medicine and Pharmacy Iasi, 700115 Iasi, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,9,7]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Zammit, D., Ettinger, R.E., Sanati-Mehrizy, P., and Susarla, S.M. (2023). Current Trends in Orthognathic Surgery. Medicina, 59.","DOI":"10.3390\/medicina59122100"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1996","DOI":"10.1016\/j.joms.2021.04.036","article-title":"Orthognathic Surgery: Past\u2014Present\u2014Future","volume":"79","author":"Posnick","year":"2021","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1186\/s40902-023-00409-2","article-title":"Redefining Precision and Efficiency in Orthognathic Surgery through Virtual Surgical Planning and 3D Printing: A Narrative Review","volume":"45","author":"Lee","year":"2023","journal-title":"Maxillofac. Plast. Reconstr. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"945","DOI":"10.1007\/s11548-022-02596-1","article-title":"Deep Learning for Biomechanical Modeling of Facial Tissue Deformation in Orthognathic Surgical Planning","volume":"17","author":"Lampen","year":"2022","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Onic\u0103, N., Onic\u0103, C.A., Tatarciuc, M., Baciu, E.-R., Vlasie, G.-L., Ciofu, M., Balan, M., and Gele\u021bu, G.L. (2023). Managing Predicted Post-Orthognathic Surgical Defects Using Combined Digital Software: A Case Report. Healthcare, 11.","DOI":"10.3390\/healthcare11091219"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1186\/s40902-024-00449-2","article-title":"Virtual Surgical Plan with Custom Surgical Guide for Orthognathic Surgery: Systematic Review and Meta-Analysis","volume":"46","author":"Lee","year":"2024","journal-title":"Maxillofac. Plast. Reconstr. Surg."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Erdem, M.E., \u00c7oban, G., \u00d6zt\u00fcrk, T., Ya\u011fc\u0131, A., Yavuz, \u0130., Irg\u0131n, C., G\u00fcl Amuk, N., T\u00fcrker, G., Demirba\u015f, A.E., and Soylu, E. (2025). Skeletal Deformities and Surgical Procedures in Orthognathic Surgery Patients: A 10-Year Retrospective Analysis of 1095 Cases. BMC Oral Health, 25.","DOI":"10.1186\/s12903-025-07265-8"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1913","DOI":"10.1016\/j.jcms.2016.09.008","article-title":"The Use of Patient-Specific Implants in Orthognathic Surgery: A Series of 32 Maxillary Osteotomy Patients","volume":"44","author":"Suojanen","year":"2016","journal-title":"J. Craniomaxillofac. Surg."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Diaconu, A., Holte, M.B., Berg-Beckhoff, G., and Pinholt, E.M. (2023). Three-Dimensional Accuracy and Stability of Personalized Implants in Orthognathic Surgery: A Systematic Review and a Meta-Analysis. J. Pers. Med., 13.","DOI":"10.3390\/jpm13010125"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Song, F., Xu, X., Li, Z., and Liu, X. (2025). Stability of Maxilla after Segmental Le Fort I Osteotomy Combined with Anterior Maxilla Clockwise Rotation in Patients with Maxillary Hypoplasia: A Retrospective Study. BMC Oral Health, 25.","DOI":"10.1186\/s12903-025-06057-4"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"da Costa Senior, O., Coppens, M., Jacobs, R., Shaheen, E., and Politis, C. (2026). Three-Dimensional Accuracy and Stability of Segmented Le Fort I Osteotomy\u2014A Systematic Review. Head Face Med., Epub ahead of print.","DOI":"10.1186\/s13005-026-00625-x"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Keldal, M.K., Alt\u0131n\u0131\u015f\u0131k, M., and B\u0131\u00e7ak\u00e7\u0131, A.A. (2025). Maxillary Advancement and Soft Tissue Response in Le Fort I Osteotomy. BMC Oral Health, 25.","DOI":"10.1186\/s12903-025-07267-6"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1016\/j.oooo.2024.09.002","article-title":"Comparison between 2- and 4-Plate Fixation in Le Fort I Osteotomy: A Mixed Methods Systematic Review","volume":"139","author":"Grillo","year":"2025","journal-title":"Oral Surg. Oral Med. Oral Pathol. Oral Radiol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1016\/j.jcms.2025.04.024","article-title":"Long-Term Maxillary Stability after Fixation with Two or Four Plates: A 3-D Prospective Quasi-Experimental Evaluation","volume":"53","author":"Bastos","year":"2025","journal-title":"J. Craniomaxillofac. Surg."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Nelke, K., Kotela, A., Majchrzak, Z., Weso\u0142ek, K., Ma\u0142yszek, A., Laszczy\u0144ska, M., Matys, J., and Dobrzy\u0144ski, M. (2026). Predictability, Skeletal Stability, and Safety of Iliac Crest Bone Grafts in Large Maxillary Advancement with Le Fort I Osteotomy: A Systematic Review. J. Clin. Med., 15.","DOI":"10.3390\/jcm15072586"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"6586","DOI":"10.1021\/acsbiomaterials.3c01171","article-title":"3D Printing Applications for Craniomaxillofacial Reconstruction: A Sweeping Review","volume":"9","author":"Slavin","year":"2023","journal-title":"ACS Biomater. Sci. Eng."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1016\/j.joms.2022.01.006","article-title":"Comparison of the Accuracy of Maxillary Positioning with Interim Splints versus Patient-Specific Guides and Plates in Executing a Virtual Bimaxillary Surgical Plan","volume":"80","author":"Jones","year":"2022","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"e12152","DOI":"10.1016\/j.heliyon.2022.e12152","article-title":"Biomechanical Evaluation of Chinese Customized Three-Dimensional Printed Titanium Miniplate in the LeFort I Osteotomy: A Finite Element Analysis","volume":"8","author":"Li","year":"2022","journal-title":"Heliyon"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"e1530","DOI":"10.4317\/jced.62324","article-title":"Biomechanical Evaluation of Different Fixation Techniques in the Rotation of the Maxillary Occlusal Plane after Le Fort I Osteotomy","volume":"16","author":"Castanha","year":"2024","journal-title":"J. Clin. Exp. Dent."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Jamshidi, P., Aristizabal, M., Kong, W., Villapun, V., Cox, S.C., Grover, L.M., and Attallah, M.M. (2020). Selective Laser Melting of Ti\u20136Al\u20134V: The Impact of Post-Processing on the Tensile, Fatigue and Biological Properties for Medical Implant Applications. Materials, 13.","DOI":"10.3390\/ma13122813"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Lisiak-Myszke, M., Marciniak, D., Bieli\u0144ski, M., Sobczak, H., Garbacewicz, \u0141., and Drogoszewska, B. (2020). Application of Finite Element Analysis in Oral and Maxillofacial Surgery\u2014A Literature Review. Materials, 13.","DOI":"10.3390\/ma13143063"},{"key":"ref_22","first-page":"756","article-title":"A Finite Element Analysis of Mini-Implant Effects on the Periodontium: From Biomechanical Simulation to Oral Health and Mental Wellbeing","volume":"129","author":"Cojocaru","year":"2025","journal-title":"Med. Surg. J."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1016\/j.ijom.2019.08.006","article-title":"Two-Point Nasomaxillary Fixation of the Le Fort I Osteotomy: Assessment of Stability at One Year Postoperative","volume":"49","author":"Susarla","year":"2020","journal-title":"Int. J. Oral Maxillofac. Surg."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"102666","DOI":"10.1016\/j.jormas.2025.102666","article-title":"Biomechanical Evaluation of Fixation Systems in Different Segmental Le Fort I Osteotomies: Patient-Specific Implants versus Miniplates","volume":"127","year":"2026","journal-title":"J. Stomatol. Oral Maxillofac. Surg."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"104849","DOI":"10.1016\/j.jmbbm.2021.104849","article-title":"Biomechanical Comparison of Locking and Non-Locking Patient-Specific Mandibular Reconstruction Plate Using Finite Element Analysis","volume":"124","author":"Zhong","year":"2021","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1117","DOI":"10.1016\/j.ijom.2008.10.004","article-title":"Comparison of Biomechanical Behaviour of Maxilla Following Le Fort I Osteotomy with 2- versus 4-Plate Fixation Using 3D-FEA. Part 1: Advancement Surgery","volume":"37","author":"Erkmen","year":"2008","journal-title":"Int. J. Oral Maxillofac. Surg."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"e96","DOI":"10.1016\/j.oooo.2021.08.028","article-title":"Evaluation of Internal Fixation Techniques for Condylar Head Fractures: A Finite Element Analysis and Comparison","volume":"133","author":"Bu","year":"2022","journal-title":"Oral Surg. Oral Med. Oral Pathol. Oral Radiol."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Tevet, O., Svetlizky, D., Harel, D., Barkay, Z., Geva, D., and Eliaz, N. (2022). Measurement of the Anisotropic Dynamic Elastic Constants of Additive Manufactured and Wrought Ti6Al4V Alloys. Materials, 15.","DOI":"10.3390\/ma15020638"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"742","DOI":"10.1016\/j.ijom.2014.02.005","article-title":"Two-Year Follow-up of Changes in Bite Force and Occlusal Contact Area after Intraoral Vertical Ramus Osteotomy with and without Le Fort I Osteotomy","volume":"43","author":"Choi","year":"2014","journal-title":"Int. J. Oral Maxillofac. Surg."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/S0278-2391(97)90224-X","article-title":"Effect of Mandibular Setback Surgery on Occlusal Force","volume":"55","author":"Kim","year":"1997","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"091006","DOI":"10.1115\/1.4072325","article-title":"Investigating Contact Models in Clavicle Fixation Plates: A Finite Element Study of Their Impact on Biomechanical Performance","volume":"148","author":"Kedadria","year":"2026","journal-title":"J. Biomech. Eng."},{"key":"ref_32","unstructured":"Wood, J., Olsson Robbie, M., Hamilton, N.R., Easton, D., and Zhang, Y. (2015). Theoretical Elastic Stress Singularities\u2026 Much Maligned and Misunderstood. Proceedings of the NAFEMS World Congress 2015, San Diego, CA, USA, 21\u201324 June 2015, NAFEMS. Available online: https:\/\/strathprints.strath.ac.uk\/51652\/."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"104007","DOI":"10.1016\/j.jmbbm.2020.104007","article-title":"Biomechanical Comparison of Titanium Miniplates versus a Variety of CAD\/CAM Plates in Mandibular Reconstruction","volume":"111","author":"Steffen","year":"2020","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1007\/s10006-026-01580-2","article-title":"Long-Term Patient Satisfaction and Complication Rates after Orthognathic Surgery: A Minimum 3-Year Follow-Up Study","volume":"30","author":"Hajaj","year":"2026","journal-title":"Oral Maxillofac. Surg."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1097\/SCS.0000000000009006","article-title":"Titanium Internal Fixator Removal in Maxillofacial Surgery: Is It Necessary? A Systematic Review and Meta-Analysis","volume":"34","author":"Piombino","year":"2023","journal-title":"J. Craniofac. Surg."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1016\/0021-9290(75)90075-5","article-title":"The elastic and ultimate properties of compact bone tissue","volume":"8","author":"Reilly","year":"1975","journal-title":"J. Biomech."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Aguilar, L., Vargas Buratovic, J.P., Matamala Ibaceta, V., Merchan, F., Fuhrer, A., and Toledo, X. (2026). Three-Dimensional Assessment of Maxillary Stability Using Customized Plates in Orthognathic Surgery: A Retrospective Cohort Study. Craniomaxillofac. Trauma Reconstr., 19.","DOI":"10.3390\/cmtr19020027"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"11795","DOI":"10.1038\/s41598-024-62011-4","article-title":"Biomechanical Assessment of Mandibular Fracture Fixation Using Finite Element Analysis Validated by Polymeric Mandible Mechanical Testing","volume":"14","author":"Daqiq","year":"2024","journal-title":"Sci. Rep."}],"container-title":["Journal of Functional Biomaterials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2079-4983\/17\/9\/454\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T04:19:24Z","timestamp":1788927564000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2079-4983\/17\/9\/454"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,7]]},"references-count":38,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2026,9]]}},"alternative-id":["jfb17090454"],"URL":"https:\/\/doi.org\/10.3390\/jfb17090454","relation":{},"ISSN":["2079-4983"],"issn-type":[{"value":"2079-4983","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,7]]}}}