{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T11:00:43Z","timestamp":1775732443130,"version":"3.50.1"},"reference-count":31,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T00:00:00Z","timestamp":1775692800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Imaging"],"abstract":"<jats:p>Posterior acoustic shadowing is a fundamental physical phenomenon associated with calcified stones in ultrasound image, yet it has not been fully exploited in automated ultrasound analysis. This study aimed to develop an explainable, semi-automatic rule-based framework that explicitly incorporates posterior acoustic shadow characteristics for stone detection and localization in a clinically guided manner. A rule-based framework was designed to generate stone candidates using morphological enhancement and to evaluate them through local contrast analysis, posterior shadow region assessment, and shape-based penalties. A composite score integrating these features was used to rank candidates. The method was evaluated on 52 kidney stone and 66 gallbladder stone ultrasound images, stratified into three diagnostic confidence categories. Performance was assessed using an ablation study and centroid distance error measured in pixels relative to expert-defined references. In the 50\u201360% confidence group, the accuracy increased from 0.29 to 0.64 for kidney stones and from 0.30 to 0.60 for gallbladder stones when posterior shadow information was included. Centroid distance errors in the \u226580% confidence group were 1.26 \u00b1 0.28 mm for kidney stones and 1.44 \u00b1 0.91 mm for gallbladder stones. The proposed framework enhances diagnostic confidence by leveraging physically grounded posterior acoustic shadow analysis and provides a reproducible augmentation to conventional ultrasound-based stone assessment.<\/jats:p>","DOI":"10.3390\/jimaging12040163","type":"journal-article","created":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T09:46:23Z","timestamp":1775727983000},"page":"163","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A Robust Rule-Based Framework for Stone Detection and Posterior Acoustic Shadow Localization in Abdominal Ultrasound"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7627-7394","authenticated-orcid":false,"given":"Kyuseok","family":"Kim","sequence":"first","affiliation":[{"name":"Institute of Human Convergence Health Science, Gachon University, 191 Hambakmoero, Yeonsu-gu, Incheon 21936, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3110-6468","authenticated-orcid":false,"given":"Ji-Youn","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Dental Hygiene, Gachon University, 191 Hambakmoero, Yeonsu-gu, Incheon 21936, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2026,4,9]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1007\/s00345-017-2156-8","article-title":"Retrospective comparison of measured stone size and posterior acoustic shadow width in clinical ultrasound images","volume":"36","author":"Dai","year":"2018","journal-title":"World J. Urol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"S89","DOI":"10.1089\/end.2016.0584","article-title":"Ultrasound use in urinary stones: Adapting old technology for a modern-day disease","volume":"31","author":"Tzou","year":"2017","journal-title":"J. Endourol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1100","DOI":"10.1056\/NEJMoa1404446","article-title":"Ultrasonography versus computed tomography for suspected nephrolithiasis","volume":"371","author":"Aubin","year":"2014","journal-title":"N. Engl. J. Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1038\/nrurol.2016.154","article-title":"An overview of kidney stone imaging techniques","volume":"13","author":"Brisbane","year":"2016","journal-title":"Nat. Rev. Urol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1408","DOI":"10.1148\/rg.2017160175","article-title":"Clinical significance of US artifacts","volume":"37","author":"Baad","year":"2017","journal-title":"RadioGraphics"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1111\/bju.13605","article-title":"Accuracy of ultrasonography for renal stone detection and size determination: Is it good enough for management decisions?","volume":"119","author":"Ganesan","year":"2017","journal-title":"BJU Int."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/j.juro.2015.05.111","article-title":"Use of the acoustic shadow width to determine kidney stone size with ultrasound","volume":"195","author":"Dunmire","year":"2016","journal-title":"J. Urol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1089\/end.2018.0577","article-title":"Measurement of posterior acoustic stone shadow on ultrasound is a learnable skill for inexperienced users to improve accuracy of stone sizing","volume":"32","author":"Dai","year":"2018","journal-title":"J. Endourol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1007\/s11548-016-1515-z","article-title":"Automatic gallbladder and gallstone regions segmentation in ultrasound image","volume":"12","author":"Lian","year":"2017","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1007\/s13244-015-0396-y","article-title":"Imaging patients with renal colic-consider ultrasound first","volume":"6","author":"Nicolau","year":"2015","journal-title":"Insights Imaging"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"958","DOI":"10.1089\/end.2016.0341","article-title":"Stone-mode ultrasound for determining renal stone size","volume":"30","author":"May","year":"2016","journal-title":"J. Endourol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"4006","DOI":"10.1038\/ncomms5006","article-title":"Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach","volume":"5","author":"Aerts","year":"2014","journal-title":"Nat. Commun."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/j.ejca.2011.11.036","article-title":"Radiomics: Extracting more information from medical images using advanced feature analysis","volume":"48","author":"Lambin","year":"2012","journal-title":"Eur. J. Cancer"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"4775","DOI":"10.1007\/s00330-017-4852-6","article-title":"Size matters: The width and location of ureteral stone accurately predict the chance of spontaneous passage","volume":"27","author":"Jendeberg","year":"2017","journal-title":"Eur. Radiol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"E837","DOI":"10.5489\/cuaj.3483","article-title":"CUA guideline: Management of ureteral calculi","volume":"9","author":"Ordon","year":"2015","journal-title":"Can. Urol. Assoc. J."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"401","DOI":"10.4103\/jfmpc.jfmpc_300_18","article-title":"An investigation into the clinical accuracy of twinkling artifacts in patients with urolithiasis smaller than 5 mm in comparison with computed tomography scanning","volume":"8","author":"Hanafi","year":"2019","journal-title":"J. Family Med. Prim. Care"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Xi, T., Yuan, L., and Sun, Q. (2022). A combined approach to infrared small-target detection with the alternating direction method of multipliers and an improved top-hat transformation. Sensors, 22.","DOI":"10.3390\/s22197327"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.infrared.2005.04.006","article-title":"The design of top-hat morphological filter and application to infrared target detection","volume":"48","author":"Zeng","year":"2006","journal-title":"Infrared Phys. Technol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1016\/j.ipm.2009.03.002","article-title":"A systematic analysis of performance measures for classification tasks","volume":"45","author":"Sokolova","year":"2009","journal-title":"Inf. Process. Manag."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Qureshi, A., Lim, S., Suh, S.Y., Mutawak, B., Chitnis, P.V., Demer, J.L., and Wei, Q. (2023). Deep-learning-based segmentation of extraocular muscles from magnetic resonance images. Bioengineering, 10.","DOI":"10.3390\/bioengineering10060699"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"102527","DOI":"10.1016\/j.media.2022.102527","article-title":"Object recognition in medical images via anatomy-guided deep learning","volume":"81","author":"Jin","year":"2022","journal-title":"Med. Image Anal."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.1016\/S0301-5629(00)00249-0","article-title":"Errors in ultrasound digital image distance measurements","volume":"26","author":"Goldstein","year":"2000","journal-title":"Ultrasound Med. Biol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"773","DOI":"10.12659\/PJR.904135","article-title":"Evaluation of imaging parameters of ultrasound scanners: Baseline for future testing","volume":"82","author":"Fabiszewska","year":"2017","journal-title":"Pol. J. Radiol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1080\/028418502127347484","article-title":"Interobserver agreement in ultrasound examination of the biliary tract","volume":"43","author":"Grantcharov","year":"2002","journal-title":"Acta Radiol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/BF00145045","article-title":"Inter and intea-observer variation in ultrasonographic detection of gallstones: The multicenter Italian study on epidemiology of cholelithiasis (M.I.COL.)","volume":"5","author":"Festi","year":"1989","journal-title":"Eur. J. Epidemiol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"326","DOI":"10.2214\/AJR.15.14998","article-title":"Clinical effectiveness of prospectively reported sonographic twinkling artifact for the diagnosis of renal calculus in patients without known urolithiasis","volume":"206","author":"Masch","year":"2016","journal-title":"AJR Am. J. Roentgenol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1089\/end.2012.0430","article-title":"B-mode ultrasound versus color doppler twinkling artifact in detecting kidney stones","volume":"27","author":"Sorensen","year":"2013","journal-title":"J. Endourol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1038\/s42256-019-0048-x","article-title":"Stop explaining black box machine learning models for high stakes decisions and use interpretable models instead","volume":"1","author":"Rudin","year":"2019","journal-title":"Nat. Mach. Intell."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.media.2017.07.005","article-title":"A survey on deep learning in medical image analysis","volume":"42","author":"Litjens","year":"2017","journal-title":"Med. Image Anal."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"103602","DOI":"10.1016\/j.media.2025.103602","article-title":"Structural uncertainty estimation for medical image segmentation","volume":"103","author":"Yang","year":"2025","journal-title":"Med. Image Anal."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"102949","DOI":"10.1016\/j.artmed.2024.102949","article-title":"A systematic review of few-shot learning in medical image","volume":"156","author":"Pachetti","year":"2024","journal-title":"Artif. Intell. Med."}],"container-title":["Journal of Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-433X\/12\/4\/163\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T10:08:47Z","timestamp":1775729327000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-433X\/12\/4\/163"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,9]]},"references-count":31,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026,4]]}},"alternative-id":["jimaging12040163"],"URL":"https:\/\/doi.org\/10.3390\/jimaging12040163","relation":{},"ISSN":["2313-433X"],"issn-type":[{"value":"2313-433X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,9]]}}}