{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,14]],"date-time":"2026-04-14T00:25:08Z","timestamp":1776126308962,"version":"3.50.1"},"reference-count":24,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2022,6,16]],"date-time":"2022-06-16T00:00:00Z","timestamp":1655337600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"U.S. Army Medical Research and Development Command"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JPM"],"abstract":"<jats:p>Hemorrhage is a leading cause of preventable death in trauma, which can often be avoided with proper fluid resuscitation. Fluid administration can be cognitive-demanding for medical personnel as the rates and volumes must be personalized to the trauma due to variations in injury severity and overall fluid responsiveness. Thus, automated fluid administration systems are ideal to simplify hemorrhagic shock resuscitation if properly designed for a wide range of hemorrhage scenarios. Here, we highlight the development of a proportional\u2013integral\u2013derivative (PID) controller using a hardware-in-loop test platform. The controller relies only on an input data stream of arterial pressure and a target pressure; the PID controller then outputs infusion rates to stabilize the subject. To evaluate PID controller performance with more than 10 controller metrics, the hardware-in-loop platform allowed for 11 different trauma-relevant hemorrhage scenarios for the controller to resuscitate against. Overall, the two controller configurations performed uniquely for the scenarios, with one reaching the target quicker but often overshooting, while the other rarely overshot the target but failed to reach the target during severe hemorrhage. In conclusion, PID controllers have the potential to simplify hemorrhage resuscitation if properly designed and evaluated, which can be accomplished with the test platform shown here.<\/jats:p>","DOI":"10.3390\/jpm12060979","type":"journal-article","created":{"date-parts":[[2022,6,17]],"date-time":"2022-06-17T05:25:11Z","timestamp":1655443511000},"page":"979","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Evaluation of a Proportional\u2013Integral\u2013Derivative Controller for Hemorrhage Resuscitation Using a Hardware-in-Loop Test Platform"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0293-4937","authenticated-orcid":false,"given":"Eric J.","family":"Snider","sequence":"first","affiliation":[{"name":"U.S. Army Institute of Surgical Research, JBSA Fort Sam Houston, San Antonio, TX 78234, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2286-3846","authenticated-orcid":false,"given":"David","family":"Berard","sequence":"additional","affiliation":[{"name":"U.S. Army Institute of Surgical Research, JBSA Fort Sam Houston, San Antonio, TX 78234, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Saul J.","family":"Vega","sequence":"additional","affiliation":[{"name":"U.S. Army Institute of Surgical Research, JBSA Fort Sam Houston, San Antonio, TX 78234, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9337-185X","authenticated-orcid":false,"given":"Guy","family":"Avital","sequence":"additional","affiliation":[{"name":"U.S. Army Institute of Surgical Research, JBSA Fort Sam Houston, San Antonio, TX 78234, USA"},{"name":"Trauma & Combat Medicine Branch, Surgeon General\u2019s Headquarters, Israel Defense Forces, Ramat-Gan 5262000, Israel"},{"name":"Division of Anesthesia, Intensive Care & Pain Management, Tel-Aviv Sourasky Medical Center, Tel-Aviv 6423906, Israel"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7180-2842","authenticated-orcid":false,"given":"Emily N.","family":"Boice","sequence":"additional","affiliation":[{"name":"U.S. Army Institute of Surgical Research, JBSA Fort Sam Houston, San Antonio, TX 78234, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2022,6,16]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1154","DOI":"10.1007\/s00268-013-1964-2","article-title":"Trauma-Related Preventable Deaths in Berlin 2010: Need to Change Prehospital Management Strategies and Trauma Management Education","volume":"37","author":"Kleber","year":"2013","journal-title":"World J. Surg."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"S431","DOI":"10.1097\/TA.0b013e3182755dcc","article-title":"Death on the Battlefield (2001\u20132011): Implications for the Future of Combat Casualty Care","volume":"73","author":"Eastridge","year":"2012","journal-title":"J. Trauma Acute Care Surg."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"S41","DOI":"10.1097\/TA.0000000000001436","article-title":"Hemorrhagic Blood Failure: Oxygen Debt, Coagulopathy and Endothelial Damage","volume":"82","author":"White","year":"2017","journal-title":"J. Trauma Acute Care Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1097\/ACO.0000000000000574","article-title":"Blood Transfusion Management in the Severely Bleeding Military Patient","volume":"31","author":"Gurney","year":"2018","journal-title":"Curr. Opin. Anaesthesiol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1097\/SHK.0000000000000140","article-title":"THOR Position Paper on Remote Damage Control Resuscitation: Definitions, Current Practice and Knowledge Gaps","volume":"41","author":"Jenkins","year":"2014","journal-title":"Shock"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1038\/s41746-020-0221-y","article-title":"An Overview of Clinical Decision Support Systems: Benefits, Risks, and Strategies for Success","volume":"3","author":"Sutton","year":"2020","journal-title":"NPJ Digit. Med."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"S-69","DOI":"10.1089\/dia.2021.2505","article-title":"Decision Support Systems and Closed-Loop","volume":"23","author":"Nimri","year":"2021","journal-title":"Diabetes Technol. Ther."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1186\/s13054-020-2810-1","article-title":"The Dawn of Physiological Closed-Loop Ventilation\u2014A Review","volume":"24","author":"Pomprapa","year":"2020","journal-title":"Crit. Care"},{"key":"ref_9","first-page":"S321","article-title":"Closed-Loop and Decision-Assist Resuscitation of Burn Patients","volume":"64","author":"Salinas","year":"2008","journal-title":"J. Trauma Inj. Infect. Crit. Care"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1343","DOI":"10.1109\/TCST.2011.2162412","article-title":"Clinical Decision Support and Closed-Loop Control for Cardiopulmonary Management and Intensive Care Unit Sedation Using Expert Systems","volume":"20","author":"Gholami","year":"2012","journal-title":"IEEE Trans. Control Syst. Technol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s40696-016-0029-0","article-title":"Automated Closed-Loop Resuscitation of Multiple Hemorrhages: A Comparison between Fuzzy Logic and Decision Table Controllers in a Sheep Model","volume":"3","author":"Marques","year":"2017","journal-title":"Disaster Mil. Med."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1109\/TBME.2019.2915526","article-title":"Evaluation of Fluid Resuscitation Control Algorithms via a Hardware-in-the-Loop Test Bed","volume":"67","author":"Mirinejad","year":"2020","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Snider, E.J., Vega, S.J., Ross, E., Berard, D., Hernandez-Torres, S.I., Salinas, J., and Boice, E.N. (2022). Supervisory Algorithm for Autonomous Hemodynamic Management Systems. Sensors, 22.","DOI":"10.3390\/s22020529"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"R278","DOI":"10.1186\/cc10562","article-title":"Evaluation of a Novel Closed-Loop Fluid-Administration System Based on Dynamic Predictors of Fluid Responsiveness: An in Silico Simulation Study","volume":"15","author":"Rinehart","year":"2011","journal-title":"Crit. Care"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Snider, E.J., Berard, D., Vega, S.J., Hernandez-Torres, S., Avital, G., and Boice, E.N. (Sci. Rep., 2022). Hardware in Loop Automated Testbed for Evaluating Hemorrhagic Shock Fluid Resuscitation Controllers, Sci. Rep., submitted.","DOI":"10.3390\/bioengineering9080373"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"035017","DOI":"10.1088\/2057-1976\/ac6196","article-title":"Development of the PhysioVessel: A Customizable Platform for Simulating Physiological Fluid Resuscitation","volume":"8","author":"Berard","year":"2022","journal-title":"Biomed. Phys. Eng. Express"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1097\/01.BCR.0000216512.30415.78","article-title":"Closed-Loop Resuscitation of Burn Shock","volume":"27","author":"Hoskins","year":"2006","journal-title":"J. Burn Care Res."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1109\/37.248006","article-title":"Development of the PID Controller","volume":"13","author":"Bennett","year":"1993","journal-title":"IEEE Control. Syst. Mag."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1404","DOI":"10.1109\/TAC.2003.815028","article-title":"PID Controller Design for Robust Performance","volume":"48","author":"Ho","year":"2003","journal-title":"IEEE Trans. Autom. Control."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"207","DOI":"10.2166\/wst.2001.0426","article-title":"Closed-Loop Identification and Control Application for Dissolved Oxygen Concentration in a Full-Scale Coke Wastewater Treatment Plant","volume":"43","author":"Yoo","year":"2001","journal-title":"Water Sci. Technol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1093\/milmed\/usy112","article-title":"Damage Control Resuscitation","volume":"183","author":"Cap","year":"2018","journal-title":"Mil. Med."},{"key":"ref_22","first-page":"S110","article-title":"Blood Pressure at Which Rebleeding Occurs after Resuscitation in Swine with Aortic Injury","volume":"54","author":"Sondeen","year":"2003","journal-title":"J. Trauma"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1007\/BF01143186","article-title":"Measuring the Predictive Performance of Computer-Controlled Infusion Pumps","volume":"20","author":"Varvel","year":"1992","journal-title":"J. Pharm. Biopharm."},{"key":"ref_24","unstructured":"(2022, March 25). 14:00\u201317:00 IEC 60601-1-10:2007. Available online: https:\/\/www.iso.org\/cms\/render\/live\/en\/sites\/isoorg\/contents\/data\/standard\/04\/41\/44104.html."}],"container-title":["Journal of Personalized Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4426\/12\/6\/979\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T23:32:50Z","timestamp":1760139170000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4426\/12\/6\/979"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,16]]},"references-count":24,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2022,6]]}},"alternative-id":["jpm12060979"],"URL":"https:\/\/doi.org\/10.3390\/jpm12060979","relation":{},"ISSN":["2075-4426"],"issn-type":[{"value":"2075-4426","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,16]]}}}