{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T19:43:31Z","timestamp":1789155811627,"version":"build-2803163510"},"reference-count":29,"publisher":"MDPI AG","issue":"10","license":[{"start":{"date-parts":[[2022,10,3]],"date-time":"2022-10-03T00:00:00Z","timestamp":1664755200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea","doi-asserted-by":"publisher","award":["NRF-2022R1A2C1012627"],"award-info":[{"award-number":["NRF-2022R1A2C1012627"]}],"id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JPM"],"abstract":"<jats:p>Recent studies utilizing deep convolutional neural networks (CNN) have described the central venous catheter (CVC) on chest radiography images. However, there have been no studies for the classification of the CVC tip position with a definite criterion on the chest radiograph. This study aimed to develop an algorithm for the automatic classification of proper depth with the application of automatic segmentation of the trachea and the CVC on chest radiographs using a deep CNN. This was a retrospective study that used plain chest supine anteroposterior radiographs. The trachea and CVC were segmented on images and three labels (shallow, proper, and deep position) were assigned based on the vertical distance between the tracheal carina and CVC tip. We used a two-stage approach model for the automatic segmentation of the trachea and CVC with U-net++ and automatic classification of CVC placement with EfficientNet B4. The primary outcome was a successful three-label classification through five-fold validations with segmented images and a test with segmentation-free images. Of a total of 808 images, 207 images were manually segmented and the overall accuracy of the five-fold validation for the classification of three-class labels (mean (SD)) of five-fold validation was 0.76 (0.03). In the test for classification with 601 segmentation-free images, the average accuracy, precision, recall, and F1-score were 0.82, 0.73, 0.73, and 0.73, respectively. We achieved the highest accuracy value of 0.91 in the shallow position label, while the highest F1-score was 0.82 in the deep position label. A deep CNN can achieve a comparative performance in the classification of the CVC position based on the distance from the carina to the CVC tip as well as automatic segmentation of the trachea and CVC on plain chest radiographs.<\/jats:p>","DOI":"10.3390\/jpm12101637","type":"journal-article","created":{"date-parts":[[2022,10,9]],"date-time":"2022-10-09T01:43:11Z","timestamp":1665279791000},"page":"1637","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Classification of Central Venous Catheter Tip Position on Chest X-ray Using Artificial Intelligence"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2830-9531","authenticated-orcid":false,"given":"Seungkyo","family":"Jung","sequence":"first","affiliation":[{"name":"Department of Emergency Medicine, College of Medicine, Hanyang University, Seoul 04763, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8055-1467","authenticated-orcid":false,"given":"Jaehoon","family":"Oh","sequence":"additional","affiliation":[{"name":"Department of Emergency Medicine, College of Medicine, Hanyang University, Seoul 04763, Korea"},{"name":"HY-Medical Image and Data Artificial Intelligence System (MIDAS) LAB, Hanyang University, Seoul 133791, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jongbin","family":"Ryu","sequence":"additional","affiliation":[{"name":"Department of Software and Computer Engineering, Ajou University, Suwon 11759, Gyeonggi-do, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jihoon","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Software and Computer Engineering, Ajou University, Suwon 11759, Gyeonggi-do, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juncheol","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Emergency Medicine, College of Medicine, Hanyang University, Seoul 04763, Korea"},{"name":"HY-Medical Image and Data Artificial Intelligence System (MIDAS) LAB, Hanyang University, Seoul 133791, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongil","family":"Cho","sequence":"additional","affiliation":[{"name":"Department of Emergency Medicine, College of Medicine, Hanyang University, Seoul 04763, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1019-3347","authenticated-orcid":false,"given":"Myeong Seong","family":"Yoon","sequence":"additional","affiliation":[{"name":"HY-Medical Image and Data Artificial Intelligence System (MIDAS) LAB, Hanyang University, Seoul 133791, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ji Young","family":"Jeong","sequence":"additional","affiliation":[{"name":"HY-Medical Image and Data Artificial Intelligence System (MIDAS) LAB, Hanyang University, Seoul 133791, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,10,3]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1056\/NEJMra011883","article-title":"Preventing Complications of Central Venous Catheterization","volume":"348","author":"McGee","year":"2003","journal-title":"N. Engl. J. Med."},{"key":"ref_2","unstructured":"Leib, A.D., England, B.S., and Kiel, J. (2022). Central Line, StatPearls Publishing."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"309","DOI":"10.2214\/ajr.179.2.1790309","article-title":"Central venous access: A primer for the diagnostic radiologist","volume":"179","author":"Funaki","year":"2002","journal-title":"AJR Am. J. Roentgenol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/j.crad.2012.10.013","article-title":"Imaging and management of complications of central venous catheters","volume":"68","author":"Nayeemuddin","year":"2013","journal-title":"Clin. Radiol."},{"key":"ref_5","first-page":"400","article-title":"Malposition of central venous catheters. Incidence, management and preventive practices","volume":"109","author":"Muhm","year":"1997","journal-title":"Wien Klin. Wochenschr."},{"key":"ref_6","first-page":"300","article-title":"Complications Related to Insertion and Use of Central Venous Catheters (CVC)","volume":"68","author":"Hodzic","year":"2014","journal-title":"Med. Arch."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"170","DOI":"10.4103\/2229-5151.164940","article-title":"Central line complications","volume":"5","author":"Kornbau","year":"2015","journal-title":"Int. J. Crit. Illn. Inj. Sci."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1093\/bja\/aes497","article-title":"Misplaced central venous catheters: Applied anatomy and practical management","volume":"110","author":"Gibson","year":"2013","journal-title":"BJA Br. J. Anaesth."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/S0002-9610(99)00124-5","article-title":"Silicone venous access devices positioned with their tips high in the superior vena cava are more likely to malfunction","volume":"178","author":"Petersen","year":"1999","journal-title":"Am. J. Surg."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1097\/EJA.0000000000001180","article-title":"European Society of Anaesthesiology guidelines on peri-operative use of ultrasound-guided for vascular access (PERSEUS vascular access)","volume":"37","author":"Lamperti","year":"2020","journal-title":"Eur. J. Anaesthesiol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1177\/1129729820929835","article-title":"Intracavitary electrocardiography for tip location during central venous catheterization: A narrative review of 70 years of clinical studies","volume":"22","author":"Pittiruti","year":"2021","journal-title":"J. Vasc. Access"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1378\/chest.07-2687","article-title":"Is traditional reading of the bedside chest radiograph appropriate to detect intraatrial central venous catheter position?","volume":"134","author":"Wirsing","year":"2008","journal-title":"Chest"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1186\/s13054-022-03985-3","article-title":"Ultrasound localization of central vein catheter tip by contrast-enhanced transthoracic ultrasonography: A comparison study with trans-esophageal echocardiography","volume":"26","author":"Corradi","year":"2022","journal-title":"Crit. Care"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/NAN.0000000000000396","article-title":"Infusion Therapy Standards of Practice, 8th Edition","volume":"44","author":"Gorski","year":"2021","journal-title":"J. Infus. Nurs."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1177\/1129729820907259","article-title":"(F)utility of \"routine\" postprocedural chest radiograph after hemodialysis catheter (central venous catheter) insertion","volume":"22","author":"Parmar","year":"2021","journal-title":"J. Vasc. Access."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"e041101","DOI":"10.1136\/bmjopen-2020-041101","article-title":"Chest radiography for simplified evaluation of central venous catheter tip positioning for safe and accurate haemodynamic monitoring: A retrospective observational study","volume":"11","author":"Kang","year":"2021","journal-title":"BMJ Open"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"115","DOI":"10.2147\/CEOR.S121230","article-title":"Time and resources of peripherally inserted central catheter insertion procedures: A comparison between blind insertion\/chest X-ray and a real time tip navigation and confirmation system","volume":"7","author":"Tomaszewski","year":"2017","journal-title":"Clinicoecon. Outcomes Res."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"105674","DOI":"10.1016\/j.cmpb.2020.105674","article-title":"Detection of peripherally inserted central catheter (PICC) in chest X-ray images: A multi-task deep learning model","volume":"197","author":"Yu","year":"2020","journal-title":"Comput. Methods Programs Biomed."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1007\/s10278-017-0025-z","article-title":"A Deep-Learning System for Fully-Automated Peripherally Inserted Central Catheter (PICC) Tip Detection","volume":"31","author":"Lee","year":"2018","journal-title":"J. Digit. Imaging"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1097\/RLI.0000000000000771","article-title":"Deep-Learning-Based Diagnosis of Bedside Chest X-ray in Intensive Care and Emergency Medicine","volume":"56","author":"Niehues","year":"2021","journal-title":"Investig. Radiol."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Khan, A.B.M., and Ali, S.M.A. (2021, January 29\u201330). Early Detection of Malpositioned Catheters and Lines on Chest X-Rays using Deep Learning. Proceedings of the 2021 International Conference on Artificial Intelligence and Computer Science Technology (ICAICST), Tangerang, Indonesia.","DOI":"10.1109\/ICAICST53116.2021.9497809"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Subramanian, V., Wang, H., Wu, J.T., Wong, K.C.L., Sharma, A., and Syeda-Mahmood, T. (2019, January 13\u201317). Automated Detection and Type Classification of Central Venous Catheters in Chest X-rays. Proceedings of the Medical Image Computing and Computer Assisted Intervention\u2014MICCAI 2019, Shenzhen, China.","DOI":"10.1007\/978-3-030-32226-7_58"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"e190082","DOI":"10.1148\/ryai.2020190082","article-title":"Computer-aided Assessment of Catheters and Tubes on Radiographs: How Good Is Artificial Intelligence for Assessment?","volume":"2","author":"Yi","year":"2020","journal-title":"Radiol. Artif. Intell."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1177\/147323001003800115","article-title":"Pre-measured length using landmarks on posteroanterior chest radiographs for placement of the tip of a central venous catheter in the superior vena cava","volume":"38","author":"Lee","year":"2010","journal-title":"J. Int. Med. Res."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.injury.2011.02.007","article-title":"Optimal insertion depth of central venous catheters\u2013is a formula required? A prospective cohort study","volume":"43","author":"Kim","year":"2012","journal-title":"Injury"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Jung, H.C., Kim, C., Oh, J., Kim, T.H., Kim, B., Lee, J., Chung, J.H., Byun, H., Yoon, M.S., and Lee, D.K. (2022). Position Classification of the Endotracheal Tube with Automatic Segmentation of the Trachea and the Tube on Plain Chest Radiography Using Deep Convolutional Neural Network. J. Pers. Med., 12.","DOI":"10.3390\/jpm12091363"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"e200026","DOI":"10.1148\/ryai.2020200026","article-title":"Endotracheal Tube Position Assessment on Chest Radiographs Using Deep Learning","volume":"3","author":"Lakhani","year":"2020","journal-title":"Radiol. Artif. Intell."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1016\/S1051-0443(97)70586-4","article-title":"Migration of central venous catheters: Implications for initial catheter tip positioning","volume":"8","author":"Kowalski","year":"1997","journal-title":"J. Vasc. Interv. Radiol."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1378\/chest.114.3.820","article-title":"MRI of central venous anatomy: Implications for central venous catheter insertion","volume":"114","author":"Aslamy","year":"1998","journal-title":"Chest"}],"container-title":["Journal of Personalized Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4426\/12\/10\/1637\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T00:45:48Z","timestamp":1760143548000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4426\/12\/10\/1637"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,3]]},"references-count":29,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2022,10]]}},"alternative-id":["jpm12101637"],"URL":"https:\/\/doi.org\/10.3390\/jpm12101637","relation":{},"ISSN":["2075-4426"],"issn-type":[{"value":"2075-4426","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,3]]}}}