{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T04:52:18Z","timestamp":1787028738894,"version":"build-2736575974"},"reference-count":29,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2023,2,17]],"date-time":"2023-02-17T00:00:00Z","timestamp":1676592000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Johannes Kepler University of Linz"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JPM"],"abstract":"<jats:p>(1) Background: Magnesium-based implants use has become a research focus in recent years. Radiolucent areas around inserted screws are still worrisome. The objective of this study was to investigate the first 18 patients treated using MAGNEZIX\u00ae CS screws. (2) Methods: This retrospective case series included all 18 consecutive patients treated using MAGNEZIX\u00ae CS screws at our Level-1 trauma center. Radiographs were taken at 3-, 6- and 9-month follow-ups. Osteolysis, radiolucency and material failure were assessed, as were infection and revision surgery. (3) Results: Most patients (61.1%) had surgery in the shoulder region. Radiolucency regressed from 55.6% at 3-month follow-ups to 11.1% at 9-month follow-ups. Material failure occurred in four patients (22.22%) and infection occurred in two patients, yielding a 33.33% complication rate. (4) Conclusion: MAGNEZIX\u00ae CS screws demonstrated a high percentage of radiolucency that regressed and seems to be clinically irrelevant. The material failure rate and infection rate require further research.<\/jats:p>","DOI":"10.3390\/jpm13020357","type":"journal-article","created":{"date-parts":[[2023,2,20]],"date-time":"2023-02-20T03:29:06Z","timestamp":1676863746000},"page":"357","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["High Complication Rate and High Percentage of Regressing Radiolucency in Magnesium Screw Fixation in 18 Consecutive Patients"],"prefix":"10.3390","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8207-9757","authenticated-orcid":false,"given":"David J.","family":"Haslhofer","sequence":"first","affiliation":[{"name":"Department for Orthopedics and Traumatology, Med Campus III, Kepler University Hospital Linz, Krankenhausstrasse 9, 4020 Linz, Austria"},{"name":"Faculty of Medicine, Johannes Kepler University Linz, Altenbergerstrasse 69, 4040 Linz, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tobias","family":"Gotterbarm","sequence":"additional","affiliation":[{"name":"Department for Orthopedics and Traumatology, Med Campus III, Kepler University Hospital Linz, Krankenhausstrasse 9, 4020 Linz, Austria"},{"name":"Faculty of Medicine, Johannes Kepler University Linz, Altenbergerstrasse 69, 4040 Linz, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Klasan","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Johannes Kepler University Linz, Altenbergerstrasse 69, 4040 Linz, Austria"},{"name":"Department for Orthopedics and Traumatology, AUVA Graz, G\u00f6stinger Stra\u00dfe 24, 8020 Graz, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,2,17]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1097\/00003086-200002000-00026","article-title":"Adverse Tissue Reactions to Bioabsorbable Fixation Devices","volume":"371","year":"2000","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1097\/00003086-199306000-00008","article-title":"Arthroscopic shoulder stabilization. A role for biodegradable materials","volume":"291","author":"Speer","year":"1993","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1097\/JSA.0000000000000076","article-title":"Complications of Biodegradable Materials","volume":"23","author":"Barber","year":"2015","journal-title":"Sports Med. Arthrosc. Rev."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.tcr.2017.01.012","article-title":"Bioabsorbable metal screws in traumatology: A promising innovation","volume":"8","author":"Biber","year":"2017","journal-title":"Trauma Case Rep."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1132","DOI":"10.1302\/2058-5241.6.200157","article-title":"Bioabsorbable implants in forefoot surgery: A review of materials, possibilities and disadvantages","volume":"6","author":"Pisecky","year":"2021","journal-title":"EFORT Open Rev."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1728","DOI":"10.1016\/j.biomaterials.2005.10.003","article-title":"Magnesium and its alloys as orthopedic biomaterials: A review","volume":"27","author":"Staiger","year":"2006","journal-title":"Biomaterials"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1979","DOI":"10.1016\/j.jbiomech.2013.12.003","article-title":"Revolutionizing orthopaedic biomaterials: The potential of biodegradable and bioresorbable magnesium-based materials for functional tissue engineering","volume":"47","author":"Farraro","year":"2014","journal-title":"J. Biomech."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1186\/1475-925X-12-62","article-title":"Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: Short term results of the first prospective, randomized, controlled clinical pilot study","volume":"12","author":"Windhagen","year":"2013","journal-title":"Biomed. Eng. Online"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.fuspru.2015.06.015","article-title":"Short-term results after distal metatarsal osteotomies for hallux valgus, using a biodegradable magnesium-implant","volume":"13","author":"Plaass","year":"2015","journal-title":"Fu\u00df Sprunggelenk"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2207","DOI":"10.1002\/jor.23241","article-title":"Early results using a biodegradable magnesium screw for modified chevron osteotomies","volume":"34","author":"Plaass","year":"2016","journal-title":"J. Orthop. Res.\u00ae"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1016\/j.fas.2018.02.005","article-title":"Internal fixation of three-dimensional distal metatarsal I osteotomies in the treatment of hallux valgus deformities using biodegradable magnesium screws in comparison to titanium screws","volume":"25","author":"Klauser","year":"2018","journal-title":"Foot Ankle Surg."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1186\/s12891-019-2717-7","article-title":"Hallux valgus correction utilising a modified short scarf osteotomy with a magnesium biodegradable or titanium compression screws - a comparative study of clinical outcomes","volume":"20","author":"Atkinson","year":"2019","journal-title":"BMC Musculoskelet. Disord."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"101779","DOI":"10.1016\/j.foot.2021.101779","article-title":"Matched retrospective analysis of three different fixation devices for chevron osteotomy","volume":"47","author":"Wendelstein","year":"2021","journal-title":"Foot (Edinb)"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"2265","DOI":"10.1016\/j.injury.2021.03.037","article-title":"Safety and performance of biodegradable magnesium-based implants in children and adolescents","volume":"52","author":"Delsmann","year":"2021","journal-title":"Injury"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Delsmann, M.M., St\u00fcrznickel, J., Kertai, M., St\u00fccker, R., Rolvien, T., and Rupprecht, M. (2022). Radiolucent zones of biodegradable magnesium-based screws in children and adolescents\u2014a radiographic analysis. Arch. Orthop. Trauma Surg.","DOI":"10.1007\/s00402-022-04418-0"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Heye, P., Matissek, C., Seidl, C., Varga, M., Kassai, T., Jozsa, G., and Krebs, T. (2022). Making Hardware Removal Unnecessary by Using Resorbable Implants for Osteosynthesis in Children. Children, 9.","DOI":"10.3390\/children9040471"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1007\/s00590-019-02524-1","article-title":"Comparison of magnesium versus titanium screw fixation for biplane chevron medial malleolar osteotomy in the treatment of osteochondral lesions of the talus","volume":"30","author":"Acar","year":"2020","journal-title":"Eur. J. Orthop. Surg. Traumatol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1016\/j.jos.2017.11.005","article-title":"Bioabsorbable magnesium versus standard titanium compression screws for fixation of distal metatarsal osteotomies \u2013 3 year results of a randomized clinical trial","volume":"23","author":"Plaass","year":"2018","journal-title":"J. Orthop. Sci."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1069","DOI":"10.1007\/s00402-018-2941-x","article-title":"Fixation of medial malleolar fractures with magnesium bioabsorbable headless compression screws: Short-term clinical and radiological outcomes in eleven patients","volume":"138","author":"Kose","year":"2018","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1186\/s10195-020-00547-7","article-title":"Bioabsorbable magnesium screw versus conventional titanium screw fixation for medial malleolar fractures","volume":"21","author":"May","year":"2020","journal-title":"J. Orthop. Traumatol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"108259","DOI":"10.1016\/j.matdes.2019.108259","article-title":"Mg bone implant: Features, developments and perspectives","volume":"185","author":"Yang","year":"2020","journal-title":"Mater. Des."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"S28","DOI":"10.1016\/j.actbio.2015.07.017","article-title":"Reprint of: The history of biodegradable magnesium implants: A review","volume":"23","author":"Witte","year":"2015","journal-title":"Acta Biomater."},{"key":"ref_23","first-page":"9","article-title":"The effect of hydrogen gas evolution of magnesium implant on the postimplantation mortality of rats","volume":"5","author":"Noviana","year":"2016","journal-title":"J. Orthop. Transl."},{"key":"ref_24","first-page":"1","article-title":"Comparison of SCAphoid fracture osteosynthesis by MAGnesium-based headless Herbert screws with titanium Herbert screws: Protocol for the randomized controlled SCAMAG clinical trial","volume":"20","author":"Krockenberger","year":"2019","journal-title":"BMC Musculoskelet. Disord."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1177","DOI":"10.1007\/s11837-015-1773-1","article-title":"Magnesium-Based Compression Screws: A Novelty in the Clinical Use of Implants","volume":"68","author":"Seitz","year":"2016","journal-title":"Jom"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1615\/JLongTermEffMedImplants.v13.i4.50","article-title":"Bioabsorbable screw fixation in coracoclavicular ligament reconstruction","volume":"13","author":"Talbert","year":"2003","journal-title":"J. Long Term Eff. Med. Implants"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"191","DOI":"10.3109\/17453674.2013.775046","article-title":"Surgical treatment of Rockwood grade-V acromioclavicular joint dislocations: 50 patients followed for 15\u201322 years","volume":"84","author":"Virtanen","year":"2013","journal-title":"Acta Orthop."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1091","DOI":"10.1007\/s00402-021-03898-w","article-title":"A biomechanical comparison of steel screws versus PLLA and magnesium screws for the Latarjet procedure","volume":"142","author":"Bockmann","year":"2021","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1693","DOI":"10.1016\/j.jse.2021.01.024","article-title":"Short-term complications of the Latarjet procedure: A systematic review","volume":"30","author":"Hurley","year":"2021","journal-title":"J. Shoulder Elb. Surg."}],"container-title":["Journal of Personalized Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4426\/13\/2\/357\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T18:35:48Z","timestamp":1760121348000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4426\/13\/2\/357"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,17]]},"references-count":29,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2023,2]]}},"alternative-id":["jpm13020357"],"URL":"https:\/\/doi.org\/10.3390\/jpm13020357","relation":{},"ISSN":["2075-4426"],"issn-type":[{"value":"2075-4426","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,2,17]]}}}