{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T22:52:01Z","timestamp":1787698321813,"version":"build-2784847793"},"reference-count":17,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2025,7,10]],"date-time":"2025-07-10T00:00:00Z","timestamp":1752105600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JPM"],"abstract":"<jats:p>Background: Personalized precision medicine has become a prevailing trend and applies to the selection of intraocular lenses (IOLs) for cataract surgery based on the unique corneal morphology of each person. The choice of presbyopia-correcting IOLs for post-laser-assisted in situ keratomileusis (LASIK) cataract surgery is a significant concern. However, few direct comparison studies exist between eyes with and without LASIK history. We analyzed the performance of extended depth of focus (EDOF) IOL implantation in these two groups. Methods: In this retrospective single-center study, we included patients with or without previous LASIK who underwent cataract surgery and EDOF Symfony IOL implantation, with \u22651 follow up. All patients underwent optical biometry using the IOLMaster. IOL power was calculated using the Sanders Retzslaff Kraff\/theoretical and Haigis-L formulas for patients without and with LASIK, respectively. Uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), refraction, and corneal tomography were recorded. The prediction error was the absolute difference between the postoperative sphere and target refraction. The right eyes of patients who met the inclusion criteria were selected for analysis. Results: Among the 321 recruited eyes, 18 underwent previous LASIK. After 1:3 age\/sex matching, 17 LASIK and 49 non-LASIK eyes from 66 patients were analyzed. No significant preoperative differences existed in target refraction, spherical equivalent, or best-corrected visual acuity. All surgical procedures were uneventful. LASIK exhibited non-inferiority to non-LASIK for predictive refraction error and UNVA. An age\/sex-matched regression analysis indicated no UDVA superiority between the two groups. Conclusions: Previous LASIK may have no discernible effect on the visual performance of presbyopia-correcting EDOF IOLs with respect to the absolute refractive error, UNVA, and UDVA. Longer follow-up and larger-scale studies are required to further validate these results.<\/jats:p>","DOI":"10.3390\/jpm15070301","type":"journal-article","created":{"date-parts":[[2025,7,10]],"date-time":"2025-07-10T09:38:27Z","timestamp":1752140307000},"page":"301","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Effect of Prior Laser-Assisted In Situ Keratomileusis on the Calibration Accuracy of Extended Depth of Focus Intraocular Lenses: A Direct Comparative Study"],"prefix":"10.3390","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4268-2540","authenticated-orcid":false,"given":"I-Hung","family":"Lin","sequence":"first","affiliation":[{"name":"Nobel Eye Institute, Taipei 100008, Taiwan"},{"name":"Graduate Institute of Clinical Medicine, College of Medicine, National Taiwan University, Taipei 100225, Taiwan"},{"name":"Department of Ophthalmology, Taipei Medical University Hospital, Taipei 110301, Taiwan"},{"name":"Department of Optometry, MacKay Junior College of Medicine, Nursing and Management, Taipei 112021, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7942-6407","authenticated-orcid":false,"given":"Chen-Cheng","family":"Chao","sequence":"additional","affiliation":[{"name":"Nobel Eye Institute, Taipei 100008, Taiwan"},{"name":"Department of Optometry, MacKay Junior College of Medicine, Nursing and Management, Taipei 112021, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chao-Kai","family":"Chang","sequence":"additional","affiliation":[{"name":"Nobel Eye Institute, Taipei 100008, Taiwan"},{"name":"Department of Optometry, Da-Yeh University, Chunghua 515006, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,7,10]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2085","DOI":"10.1016\/S0140-6736(18)33209-4","article-title":"Refractive surgery","volume":"393","author":"Kim","year":"2019","journal-title":"Lancet"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Mai, E.L., Chang, C.-K., Lee, C.-Y., Lian, I.-B., and Chao, C.-C. (2023). Higher-order aberrations of topography-guided LASIK and wavefront-optimized LASIK in high- and low-myopic eyes: A non-randomized controlled trial. J. Pers. Med., 13.","DOI":"10.3390\/jpm13030399"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"e132","DOI":"10.1016\/j.ophtha.2020.08.025","article-title":"Matching the patient to the intraocular lens: Preoperative considerations to optimize surgical outcomes","volume":"128","author":"Yeu","year":"2021","journal-title":"Ophthalmology"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1016\/j.jcrs.2015.11.039","article-title":"Accuracy of the Barrett True-K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopia","volume":"42","author":"Abulafia","year":"2016","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/j.bjae.2019.03.004","article-title":"Non-inferiority statistics and equivalence studies","volume":"19","author":"Walker","year":"2019","journal-title":"BJA Educ."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1186\/1745-6215-13-75","article-title":"Small incision lenticule extraction (SMILE) versus laser in-situ keratomileusis (LASIK): Study protocol for a randomized, non-inferiority trial","volume":"13","author":"Ang","year":"2012","journal-title":"Trials"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"e010381","DOI":"10.1136\/bmjopen-2015-010381","article-title":"Randomised, single-masked non-inferiority trial of femtosecond laser-assisted versus manual phacoemulsification cataract surgery for adults with visually significant cataract: The FACT trial protocol","volume":"5","author":"Day","year":"2015","journal-title":"BMJ Open"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"e94","DOI":"10.1016\/j.ophtha.2020.08.010","article-title":"Intraocular lens power formulas, biometry, and intraoperative aberrometry: A review","volume":"128","author":"Kane","year":"2021","journal-title":"Ophthalmology"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1016\/j.ajo.2020.01.009","article-title":"Determining and comparing the effective lens position and refractive outcome of a novel rhexis-fixated lens to established lens designs","volume":"213","author":"Shajari","year":"2020","journal-title":"Am. J. Ophthalmol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"5662","DOI":"10.1364\/AO.426155","article-title":"Pre-clinical estimation of the intraocular lens A-constant, and its relationship to power, shape factor, and asphericity","volume":"60","author":"Simpson","year":"2021","journal-title":"Appl. Opt."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Ota, Y., Bissen-Miyajima, H., Nakamura, K., Hirasawa, M., and Minami, K. (2020). Binocular visual function after staged implantation of extended-depth-of-focus intraocular lens targeting emmetropia and -0.5 diopter: A prospective comparison. PLoS ONE, 15.","DOI":"10.1371\/journal.pone.0238135"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"158","DOI":"10.3928\/1081597X-20221221-03","article-title":"Accuracy of nine formulas to calculate the powers of an extended depth-of-focus IOL using two SS-OCT biometers","volume":"39","author":"Jeon","year":"2023","journal-title":"J. Refract. Surg."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1097\/ICU.0b013e32835ab457","article-title":"The role of presbyopia-correcting intraocular lenses after laser in situ keratomileusis","volume":"24","author":"Khor","year":"2013","journal-title":"Curr. Opin. Ophthalmol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/j.jcrs.2015.12.005","article-title":"Metaanalysis of intraocular lens power calculation after laser refractive surgery in myopic eyes","volume":"42","author":"Chen","year":"2016","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_15","first-page":"3349","article-title":"Optical response to LASIK surgery for myopia from total and corneal aberration measurements","volume":"42","author":"Marcos","year":"2001","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"7689","DOI":"10.21037\/apm-21-1677","article-title":"High-order aberration changes after femtosecond LASIK surgery in patients with high myopia","volume":"10","author":"Feng","year":"2021","journal-title":"Ann. Palliat. Med."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"3211","DOI":"10.1007\/s10792-022-02322-5","article-title":"Assessment of the influence of keratometry on intraocular lens calculation formulas in long axial length eyes","volume":"42","author":"Yin","year":"2022","journal-title":"Int. Ophthalmol."}],"container-title":["Journal of Personalized Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4426\/15\/7\/301\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T18:07:40Z","timestamp":1760033260000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4426\/15\/7\/301"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,10]]},"references-count":17,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2025,7]]}},"alternative-id":["jpm15070301"],"URL":"https:\/\/doi.org\/10.3390\/jpm15070301","relation":{},"ISSN":["2075-4426"],"issn-type":[{"value":"2075-4426","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,10]]}}}