{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T03:13:30Z","timestamp":1780370010940,"version":"3.54.1"},"reference-count":27,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2025,8,21]],"date-time":"2025-08-21T00:00:00Z","timestamp":1755734400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JPM"],"abstract":"<jats:p>Background: Long-term follow-up after endovascular aortic repair (TEVAR) is crucial to detect adverse aortic remodeling, even with modern stent grafts offering enhanced flexibility and durability. Conventional imaging, based on diameter measurements, may fail to identify complications such as endograft migration. Methods: We conducted a longitudinal 3D geometric analysis of thoracic aortic and stent-graft evolution over 10 years in a patient treated for descending thoracic aortic aneurysm (DTAA) by endovascular treatment. A three-dimensional morphological analysis (length, tortuosity, angulation, and diameter) was carried out using advanced imaging software (EndoSize, MATLAB) to track aortic geometry and stent-graft behavior over time. A focused review of the literature on stent-graft migration, its risk factors, complications, and surveillance strategies was also performed. Results: This case illustrates how progressive geometric remodeling\u2014including aortic elongation and increased tortuosity\u2014can lead to delayed stent-graft migration and late type III endoleaks, with an elevated risk of rupture. The 3D analysis revealed early morphological changes that were undetectable using standard diameter-based follow-up. These observations are consistent with published data showing higher migration rates over time, particularly in tortuous anatomies. The literature review further emphasizes the clinical relevance of geometric surveillance, given the high rates of reintervention, morbidity, and mortality associated with stent-graft migration. Conclusions: This study underlines the importance of personalized and geometry-based surveillance after TEVAR. Advanced morphological assessment tools provide valuable insights for the early detection of complications and tailored patient management. Their integration into routine follow-up could help optimize long-term outcomes and prevent life-threatening events such as rupture.<\/jats:p>","DOI":"10.3390\/jpm15080393","type":"journal-article","created":{"date-parts":[[2025,8,21]],"date-time":"2025-08-21T15:19:02Z","timestamp":1755789542000},"page":"393","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Geometric Aortic Remodeling and Stent-Graft Migration After TEVAR: Insights from Longitudinal 3D Analysis and Literature Review"],"prefix":"10.3390","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4779-8112","authenticated-orcid":false,"given":"Mariangela","family":"De Masi","sequence":"first","affiliation":[{"name":"Timone Aortic Center, Department of Vascular Surgery, Assistance Publique-H\u00f4pitaux de Marseille, Timone Hospital, 13005 Marseille, France"},{"name":"CNRS, Centrale Marseille, Institut de Recherche sur les Ph\u00e9nom\u00e8nes Hors Equilibre, Aix Marseille University, 13013 Marseille, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-6114-6590","authenticated-orcid":false,"given":"Carine","family":"Guivier-Curien","sequence":"additional","affiliation":[{"name":"CNRS, Centrale Marseille, Institut de Recherche sur les Ph\u00e9nom\u00e8nes Hors Equilibre, Aix Marseille University, 13013 Marseille, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marine","family":"Gaudry","sequence":"additional","affiliation":[{"name":"Timone Aortic Center, Department of Vascular Surgery, Assistance Publique-H\u00f4pitaux de Marseille, Timone Hospital, 13005 Marseille, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexis","family":"Jacquier","sequence":"additional","affiliation":[{"name":"Department of Radiology, Assistance Publique-H\u00f4pitaux de Marseille, Timone Hospital, 13005 Marseille, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philippe","family":"Piquet","sequence":"additional","affiliation":[{"name":"Timone Aortic Center, Department of Vascular Surgery, Assistance Publique-H\u00f4pitaux de Marseille, Timone Hospital, 13005 Marseille, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Val\u00e9rie","family":"Deplano","sequence":"additional","affiliation":[{"name":"CNRS, Centrale Marseille, Institut de Recherche sur les Ph\u00e9nom\u00e8nes Hors Equilibre, Aix Marseille University, 13013 Marseille, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,8,21]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1016\/j.jvs.2016.11.029","article-title":"Durable Outcomes of Thoracic Endovascular Aortic Repair with Zenith TX1 and TX2 Devices","volume":"65","author":"Beach","year":"2017","journal-title":"J. Vasc. Surg."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"91S","DOI":"10.1016\/j.jvs.2010.06.149","article-title":"Endoleak Management and Postoperative Surveillance Following Endovascular Repair of Thoracic Aortic Aneurysms","volume":"52","author":"Ricotta","year":"2010","journal-title":"J. Vasc. Surg."},{"key":"ref_3","first-page":"1840","article-title":"Thoracic Aorta Remodeling after TEVAR: Monitoring Morphological Parameters to Predict Unfavorable Evolution","volume":"8","year":"2023","journal-title":"J. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1093\/ejcts\/ezab366","article-title":"Endovascular Repair of Descending Thoracic Aortic Aneurysms\u2014A Mid-Term Report from the Global Registry for Endovascular Aortic Treatment (GREAT)","volume":"61","author":"Grassi","year":"2022","journal-title":"Eur. J. Cardio-Thorac. Surg."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"2012","DOI":"10.1016\/j.jtcvs.2020.06.026","article-title":"Outcomes of Type Ia Endoleaks after Endovascular Repair of the Proximal Aorta","volume":"163","author":"Cheng","year":"2022","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.avsg.2023.07.111","article-title":"Aortic Remodeling After Thoracic Endovascular Aortic Repair for Nonacute Uncomplicated Type B Aortic Dissection","volume":"99","author":"Nomura","year":"2024","journal-title":"Ann. Vasc. Surg."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1177\/15266028231168351","article-title":"Ascending Aortic Endograft and Thoracic Aortic Deformation After Ascending Thoracic Endovascular Aortic Repair","volume":"32","author":"Suh","year":"2025","journal-title":"J. Endovasc. Ther."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"912","DOI":"10.1016\/j.avsg.2010.03.018","article-title":"Sizing for Endovascular Aneurysm Repair: Clinical Evaluation of a New Automated Three-Dimensional Software","volume":"24","author":"Kaladji","year":"2010","journal-title":"Ann. Vasc. Surg."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1016\/j.jvs.2010.07.008","article-title":"Reporting Standards for Thoracic Endovascular Aortic Repair (TEVAR)","volume":"52","author":"Fillinger","year":"2010","journal-title":"J. Vasc. Surg."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Chen, C.-K., Chou, H.-P., Chang, Y.-Y., and Shih, C.-C. (2020). Elongation of the Aorta after Thoracic Endovascular Aortic Repair: A Longitudinal Study. Int. J. Environ. Res. Public Health, 17.","DOI":"10.3390\/ijerph17041205"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1491","DOI":"10.1016\/j.jvs.2021.04.063","article-title":"Long-Term Outcomes of the Conformable TAG Thoracic Endoprosthesis in a Prospective Multicenter Trial","volume":"74","author":"Jordan","year":"2021","journal-title":"J. Vasc. Surg."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"669","DOI":"10.1016\/j.jvs.2011.03.010","article-title":"Sex-Based Outcomes after Endovascular Repair of Thoracic Aortic Aneurysms","volume":"54","author":"Kasirajan","year":"2011","journal-title":"J. Vasc. Surg."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"97","DOI":"10.3126\/kumj.v12i2.13653","article-title":"Delayed Graft Dislocation after Thoracic Aortic Endovascular Repair","volume":"12","author":"Piffaretti","year":"2014","journal-title":"Kathmandu Univ. Med. J."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1214","DOI":"10.1016\/j.jvs.2012.04.071","article-title":"VALOR Investigators Results with the Talent Thoracic Stent Graft in the VALOR Trial","volume":"56","author":"Foley","year":"2012","journal-title":"J. Vasc. Surg."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.1016\/j.jvs.2018.07.073","article-title":"Endograft Migration after Thoracic Endovascular Aortic Repair","volume":"69","author":"Skrypnik","year":"2019","journal-title":"J. Vasc. Surg."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1883","DOI":"10.1016\/j.jvs.2020.03.033","article-title":"Outcome Comparison of Thoracic Endovascular Aortic Repair Performed Outside versus inside Proximal Landing Zone Length Recommendation","volume":"72","author":"Yoon","year":"2020","journal-title":"J. Vasc. Surg."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jvs.2014.01.043","article-title":"Five-Year Results of Thoracic Endovascular Aortic Repair with the Zenith TX2","volume":"60","author":"Matsumura","year":"2014","journal-title":"J. Vasc. Surg."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1177\/15266028211049340","article-title":"A 10-Year Single-Center Experience with the GORE TAG Conformable Thoracic Stent Graft in the Treatment of Thoracic Aortic Disease","volume":"29","author":"Skrypnik","year":"2022","journal-title":"J. Endovasc. Ther."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1177\/1526602820913007","article-title":"One-Year Results from the SURPASS Observational Registry of the CTAG Stent-Graft with the Active Control System","volume":"27","author":"Torsello","year":"2020","journal-title":"J. Endovasc. Ther."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1016\/j.jvs.2019.04.484","article-title":"Reinterventions in the Modern Era of Thoracic Endovascular Aortic Repair","volume":"71","author":"Fairman","year":"2020","journal-title":"J. Vasc. Surg."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.jvs.2005.09.041","article-title":"Aortic Neck Morphology after Endovascular Repair of Descending Thoracic Aortic Aneurysms","volume":"43","author":"Hassoun","year":"2006","journal-title":"J. Vasc. Surg."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.jvs.2008.02.028","article-title":"Thoracic Aortic Lesions Treated with the Zenith TX1 and TX2 Thoracic Devices: Intermediate- and Long-Term Outcomes","volume":"48","author":"Morales","year":"2008","journal-title":"J. Vasc. Surg."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1583\/05-1699.1","article-title":"Movement and Dislocation of Modular Stent-Grafts Due to Pulsatile Flow and the Pressure Difference Between the Stent-Graft and the Aneurysm Sac","volume":"13","author":"Liffman","year":"2006","journal-title":"J. Endovasc. Ther."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"821","DOI":"10.1016\/j.jvs.2009.10.114","article-title":"Validation of a New Standardized Method to Measure Proximal Aneurysm Neck Angulation","volume":"51","author":"Moll","year":"2010","journal-title":"J. Vasc. Surg."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1048","DOI":"10.1177\/0954411917731592","article-title":"Using Multiple Classifiers for Predicting the Risk of Endovascular Aortic Aneurysm Repair Re-Intervention through Hybrid Feature Selection","volume":"231","author":"Attallah","year":"2017","journal-title":"Proc. Inst. Mech. Eng. H"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1016\/j.avsg.2021.02.042","article-title":"Drag Forces after Thoracic Endovascular Aortic Repair. General Review of the Literature","volume":"75","author":"Domanin","year":"2021","journal-title":"Ann. Vasc. Surg."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1016\/j.jvs.2019.12.026","article-title":"Artificial Intelligence in Abdominal Aortic Aneurysm","volume":"72","author":"Raffort","year":"2020","journal-title":"J. Vasc. Surg."}],"container-title":["Journal of Personalized Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4426\/15\/8\/393\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T18:32:34Z","timestamp":1760034754000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4426\/15\/8\/393"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,21]]},"references-count":27,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2025,8]]}},"alternative-id":["jpm15080393"],"URL":"https:\/\/doi.org\/10.3390\/jpm15080393","relation":{},"ISSN":["2075-4426"],"issn-type":[{"value":"2075-4426","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,21]]}}}