{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T08:05:45Z","timestamp":1790928345339,"version":"4.1.0"},"reference-count":24,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2026,2,21]],"date-time":"2026-02-21T00:00:00Z","timestamp":1771632000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JPM"],"abstract":"<jats:p>Background: The use of augmented reality (AR) in orthopaedics is growing rapidly but is mainly limited to pre-operative planning and teaching. This study is one of the first to describe the intraoperative application within revision arthroplasty for the positioning of customised partial pelvic replacements. Methods: In a proof-of-concept study an AR environment was used during surgery in 11 cases to enhance implant positioning. Postoperatively, a voxel-based CT deviation analysis was carried out to determine the COR deviation and the cup plane deviation angle. Additionally, digital implant superimposition was conducted. Results: Implantation was possible in all cases with a mean COR deviation vector of 4.2 (SD 2.5; 1.2\u20139.3) mm and a cup plane deviation angle of 4.4 (SD 2.5; 0.7\u20138.1)\u00b0. The implant analysis showed a superimposition of 0.69 (SD 0.15; 0.38\u20130.88) (Dice-Score calculation). Conclusions: This study is able to report promising results for AR in orthopaedic surgery, showing improved intraoperative feedback in complex operations, resulting in increased accuracy. However, the integration of AR poses a new challenge to the surgical team, especially because the AR users are facing a significantly increased level of intraoperative stress. Further development of this auspicious tool, as well as a conceivable combination with navigation, is necessary to facilitate broader usage.<\/jats:p>","DOI":"10.3390\/jpm16020124","type":"journal-article","created":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T08:58:21Z","timestamp":1771837101000},"page":"124","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Implementation of an Intraoperative Augmented Reality Environment for Custom-Made Partial Pelvis Replacements\u2014A Proof of Concept and Initial Results"],"prefix":"10.3390","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4940-6928","authenticated-orcid":false,"given":"Yannik","family":"Hanusrichter","sequence":"first","affiliation":[{"name":"Department of Tumour Orthopaedics and Revision Arthroplasty, Orthopaedic Hospital, Volmarstein, Lothar-Gau-Str. 11, 58300 Wetter, Germany"},{"name":"Center for Musculoskeletal Surgery, University Hospital of Essen, 45147 Essen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carsten","family":"Gebert","sequence":"additional","affiliation":[{"name":"Department of Tumour Orthopaedics and Revision Arthroplasty, Orthopaedic Hospital, Volmarstein, Lothar-Gau-Str. 11, 58300 Wetter, Germany"},{"name":"Department of Orthopedics and Tumor Orthopedics, Muenster University Hospital, 48149 Muenster, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sven","family":"Frieler","sequence":"additional","affiliation":[{"name":"Department of Tumour Orthopaedics and Revision Arthroplasty, Orthopaedic Hospital, Volmarstein, Lothar-Gau-Str. 11, 58300 Wetter, Germany"},{"name":"Department of Trauma and Orthopedic Surgery, BG University Hospital Bergmannsheil, Ruhr-University Bochum (RUB), 44789 Bochum, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6641-5506","authenticated-orcid":false,"given":"Marcel","family":"Dudda","sequence":"additional","affiliation":[{"name":"Center for Musculoskeletal Surgery, University Hospital of Essen, 45147 Essen, Germany"},{"name":"Department of Trauma Surgery, University Hospital Essen, 45147 Essen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-7943-2579","authenticated-orcid":false,"given":"Arne","family":"Streitbuerger","sequence":"additional","affiliation":[{"name":"Center for Musculoskeletal Surgery, University Hospital of Essen, 45147 Essen, Germany"},{"name":"Department of Orthopedic Oncology, University Hospital Essen, 45147 Essen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jendrik","family":"Hardes","sequence":"additional","affiliation":[{"name":"Center for Musculoskeletal Surgery, University Hospital of Essen, 45147 Essen, Germany"},{"name":"Department of Orthopedic Oncology, University Hospital Essen, 45147 Essen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lee","family":"Jeys","sequence":"additional","affiliation":[{"name":"Department of Oncology, The Royal Orthopaedic Hospital, Birmingham B31 2AP, UK"},{"name":"Faculty of Health Sciences, Aston University, Birmingham B4 7ET, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Wessling","sequence":"additional","affiliation":[{"name":"Department of Tumour Orthopaedics and Revision Arthroplasty, Orthopaedic Hospital, Volmarstein, Lothar-Gau-Str. 11, 58300 Wetter, Germany"},{"name":"Center for Musculoskeletal Surgery, University Hospital of Essen, 45147 Essen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,2,21]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"688","DOI":"10.1302\/2633-1462.58.BJO-2024-0029.R1","article-title":"Monoflange custom-made partial pelvis replacements offer a viable solution in extensive Paprosky III defects","volume":"5","author":"Hanusrichter","year":"2024","journal-title":"Bone Jt. Open"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Zoccali, C., Ruggieri, P., and Benazzo, F. (2022). When the bone is not enough: The role of custom-made implants in cup revision surgery. 3D Printing in Bone Surgery, Springer International Publishing.","DOI":"10.1007\/978-3-030-91900-9"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1530\/EOR-22-0081","article-title":"Custom triflange acetabular components for large acetabular defect reconstruction in revision total hip arthroplasty: A systematic review and meta-analysis on 1218 patients","volume":"8","author":"Broekhuis","year":"2023","journal-title":"EFORT Open Rev."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.1016\/j.arth.2015.11.016","article-title":"Outcomes of custom flange acetabular components in revision total hip arthroplasty and predictors of failure","volume":"31","author":"Barlow","year":"2016","journal-title":"J. Arthroplast."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1110","DOI":"10.1302\/0301-620X.104B10.BJJ-2022-0508.R1","article-title":"Reconstruction of paprosky iii defects with custom-made implants: Do we get them in the correct position?: Short-term radiological results","volume":"104","author":"Wessling","year":"2022","journal-title":"Bone Jt. J."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2235","DOI":"10.1007\/s00264-018-4193-3","article-title":"Customized implants for acetabular Paprosky III defects may be positioned with high accuracy in revision hip arthroplasty","volume":"43","author":"Weber","year":"2019","journal-title":"Int. Orthop."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1007\/s00064-023-00826-6","article-title":"Customized partial pelvis replacement: Three-dimensional planning and management concepts","volume":"35","author":"Wessling","year":"2023","journal-title":"Oper. Orthop. Traumatol."},{"key":"ref_8","first-page":"341","article-title":"Custom-made triflanged acetabular components in the treatment of major acetabular defects. Short-term results and clinical experience","volume":"83","author":"Myncke","year":"2017","journal-title":"Acta Orthop. Belg."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"8332","DOI":"10.1038\/s41598-024-59115-2","article-title":"Comparison between accuracy of augmented reality computed tomography-based and portable augmented reality-based navigation systems for cup insertion in total hip arthroplasty","volume":"14","author":"Hasegawa","year":"2024","journal-title":"Sci. Rep."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"914","DOI":"10.1111\/os.12537","article-title":"Mixed reality combined with three-dimensional printing technology in total hip arthroplasty: An updated review with a preliminary case presentation","volume":"11","author":"Lei","year":"2019","journal-title":"Orthop. Surg."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"\u0141\u0119gosz, P., Starszak, K., Stanuch, M., Otworowski, M., Pulik, \u0141., Z\u0142ahoda-Huzior, A., and Skalski, A. (2022). The use of mixed reality in custom-made revision hip arthroplasty: A first case report. J. Vis. Exp., e63654.","DOI":"10.3791\/63654"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2253","DOI":"10.1007\/s00264-023-05823-9","article-title":"Beyond type III Paprosky acetabular defects: Are partial pelvic replacements with iliosacral fixation successful?","volume":"47","author":"Hanusrichter","year":"2023","journal-title":"Int. Orthop."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1007\/s00264-022-05507-w","article-title":"Clinical applications of augmented reality in orthopaedic surgery: A comprehensive narrative review","volume":"47","author":"Lex","year":"2023","journal-title":"Int. Orthop."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1007\/s12178-021-09699-3","article-title":"Augmented reality in orthopedic surgery is emerging from proof of concept towards clinical studies: A literature review explaining the technology and current state of the art","volume":"14","author":"Casari","year":"2021","journal-title":"Curr. Rev. Musculoskelet. Med."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1007\/s12178-021-09728-1","article-title":"Augmented reality (ar) in orthopedics: Current applications and future directions","volume":"14","author":"Furman","year":"2021","journal-title":"Curr. Rev. Musculoskelet. Med."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"780","DOI":"10.1302\/0301-620X.97B6.35129","article-title":"The accuracy of positioning of a custom-made implant within a large acetabular defect at revision arthroplasty of the hip","volume":"97","author":"Baauw","year":"2015","journal-title":"Bone Jt. J."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1177\/230949900401200205","article-title":"Total hip arthroplasty: The relationship between posterolateral reconstruction, abductor muscle strength, and femoral offset","volume":"12","author":"Yamaguchi","year":"2004","journal-title":"J. Orthop. Surg."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1016\/j.arth.2004.01.016","article-title":"Reconstructed hip joint position and abductor muscle strength after total hip arthroplasty","volume":"20","author":"Asayama","year":"2005","journal-title":"J. Arthroplast."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1007\/s12178-021-09713-8","article-title":"The clinical application of augmented reality in orthopaedics: Where do we stand?","volume":"14","author":"Matthews","year":"2021","journal-title":"Curr. Rev. Musculoskelet. Med."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"e37599","DOI":"10.2196\/37599","article-title":"Application of virtual and augmented reality technology in hip surgery: Systematic review","volume":"25","author":"Sun","year":"2023","journal-title":"J. Med. Internet Res."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1595","DOI":"10.1007\/s10439-018-2055-1","article-title":"Augmented reality based navigation for computer assisted hip resurfacing: A proof of concept study","volume":"46","author":"Liu","year":"2018","journal-title":"Ann. Biomed. Eng."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1833","DOI":"10.1016\/j.arth.2018.01.067","article-title":"A pilot study of augmented reality technology applied to the acetabular cup placement during total hip arthroplasty","volume":"33","author":"Ogawa","year":"2018","journal-title":"J. Arthroplast."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1097\/CORR.0000000000001083","article-title":"Does an augmented reality-based portable navigation system improve the accuracy of acetabular component orientation during THA? A randomized controlled trial","volume":"478","author":"Ogawa","year":"2020","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"316","DOI":"10.3171\/2020.6.SPINE20370","article-title":"A cadaveric precision and accuracy analysis of augmented reality-mediated percutaneous pedicle implant insertion","volume":"34","author":"Molina","year":"2021","journal-title":"J. Neurosurg. Spine"}],"container-title":["Journal of Personalized Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4426\/16\/2\/124\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T13:52:50Z","timestamp":1773323570000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4426\/16\/2\/124"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,21]]},"references-count":24,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,2]]}},"alternative-id":["jpm16020124"],"URL":"https:\/\/doi.org\/10.3390\/jpm16020124","relation":{},"ISSN":["2075-4426"],"issn-type":[{"value":"2075-4426","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,21]]}}}