{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T09:32:36Z","timestamp":1760866356979,"version":"build-2065373602"},"reference-count":26,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2021,11,17]],"date-time":"2021-11-17T00:00:00Z","timestamp":1637107200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Life"],"abstract":"<jats:p>(1) Background: In polytrauma patients, femur fractures are usually stabilised by external fixation for damage control, later being treated with definitive plate or nail osteosynthesis. Screw\/rod systems established in spinal surgery might be inserted for internal fixation, providing sufficient fracture stability that subsequent intervention is unnecessary. This was to be investigated biomechanically. (2) Methods: The unilaterally applied spinal internal fixator (IF) was subjected to load and deformation analysis on artificial femurs with 32-A3 fracture according to AO classification. Distance of screws to fracture and rod to cortical bone were analysed as parameters influenced surgically as stiffness and deformation of the treated fracture. In addition, the stability of another construct with a second screw\/rod system was determined. The axial load in stance phase during walking was simulated. The results were compared against an established fixed-angle plate osteosynthesis (IP). (3) Results: There were no implant failures in the form of fractures, avulsions or deformations. All unilateral IF combinations were inferior to IP in terms of stability and stiffness. The bilateral construct with two screw\/rod systems achieved biomechanical properties comparable to IP. 4) Conclusion: Biomechanically, a biplanar screw\/rod system is suitable for definitive fracture stabilisation of the femur, despite a damage control approach.<\/jats:p>","DOI":"10.3390\/life11111254","type":"journal-article","created":{"date-parts":[[2021,11,17]],"date-time":"2021-11-17T21:32:07Z","timestamp":1637184727000},"page":"1254","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Minimally Invasive Internal Fixation of Femoral Shaft Fractures\u2014A Biomechanical Study with a Disruptive Technique"],"prefix":"10.3390","volume":"11","author":[{"given":"Frank","family":"Layher","sequence":"first","affiliation":[{"name":"Orthopaedic Department Waldkliniken Eisenberg, Orthopaedic Professorship of the University Hospital Jena, 07607 Eisenberg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Georg","family":"Matziolis","sequence":"additional","affiliation":[{"name":"Orthopaedic Department Waldkliniken Eisenberg, Orthopaedic Professorship of the University Hospital Jena, 07607 Eisenberg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5299-513X","authenticated-orcid":false,"given":"Leos N.","family":"Kayhan","sequence":"additional","affiliation":[{"name":"Schulthess Clinic, Lengghalde 2, 8008 Z\u00fcrich, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthias","family":"Bungartz","sequence":"additional","affiliation":[{"name":"Orthopaedic Department Waldkliniken Eisenberg, Orthopaedic Professorship of the University Hospital Jena, 07607 Eisenberg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Olaf","family":"Brinkmann","sequence":"additional","affiliation":[{"name":"Orthopaedic Department Waldkliniken Eisenberg, Orthopaedic Professorship of the University Hospital Jena, 07607 Eisenberg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2021,11,17]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.jcot.2020.10.018","article-title":"Damage control orthopaedics in polytraumatized patients- current concepts","volume":"12","author":"Volpin","year":"2020","journal-title":"J. Clin. Orthop. Trauma"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/BOT.0000000000001063","article-title":"Fracture and Dislocation Classification Compendium\u20142018","volume":"32","author":"Meinberg","year":"2018","journal-title":"J. Orthop. Trauma"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"65","DOI":"10.3233\/BME-2010-0616","article-title":"Realistic loads for testing hip implants","volume":"20","author":"Bergmann","year":"2010","journal-title":"Bio-Med. Mater. Eng."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Bergmann, G., Bender, A., Dymke, J., Duda, G., and Damm, P. (2016). Standardized Loads Acting in Hip Implants. PLoS ONE, 11.","DOI":"10.1371\/journal.pone.0155612"},{"key":"ref_5","unstructured":"Leitlinien Unfallchirurgie \u00a9 DGU (2021, September 01). Leitlinien Kommission Berlin 2018, AWMF-Nr. 012-027. Available online: https:\/\/www.awmf.org\/uploads\/tx_szleitlinien\/012-027l_S1_Oberschenkelschaftfraktur_2018-07.pdf."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"529","DOI":"10.2106\/00004623-198466040-00006","article-title":"Closed intramedullary nailing of femoral fractures. A report of five hundred and twenty cases","volume":"66","author":"Winquist","year":"1984","journal-title":"J. Bone Jt. Surg."},{"key":"ref_7","first-page":"94","article-title":"The history of intramedullary nailing","volume":"64","author":"Bong","year":"2006","journal-title":"Bull. NYU Hosp. Jt. Dis."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"22","DOI":"10.55095\/achot2015\/003","article-title":"Management of femoral shaft fractures","volume":"82","author":"Neumann","year":"2015","journal-title":"Acta Chir. Orthop. Traumatol. Cechoslov."},{"key":"ref_9","first-page":"239","article-title":"Entwicklung und Prinzipien der Verriegelungsmarknagelung","volume":"121","author":"Hierholzer","year":"2018","journal-title":"Der Unf."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1097\/01.blo.0000218760.19934.2b","article-title":"Femoral Biologic Plate Fixation","volume":"450","author":"Papakostidis","year":"2006","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"347","DOI":"10.5435\/00124635-200806000-00007","article-title":"Locked Plating in Orthopaedic Trauma: A Clinical Update","volume":"16","author":"Haidukewych","year":"2008","journal-title":"J. Am. Acad. Orthop. Surg."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1007\/s00264-008-0603-2","article-title":"Minimally invasive plate osteosynthesis (MIPO) in the treatment of the femoral shaft fracture where intramedullary nailing is not indicated","volume":"33","author":"Apivatthakakul","year":"2009","journal-title":"Int. Orthop."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1016\/j.injury.2010.01.101","article-title":"Less invasive percutaneous wave plating of simple femur shaft fractures: A prospective series","volume":"41","author":"Angelini","year":"2010","journal-title":"Injury"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"159","DOI":"10.5505\/tjtes.2011.24892","article-title":"Comparison of two biological internal fixation techniques in the treatment of adult femur shaft fractures (plate-screws and locked intramedullary nail)","volume":"17","author":"Durak","year":"2011","journal-title":"Turk. J. Trauma Emerg. Surg."},{"key":"ref_15","first-page":"62","article-title":"Possibilities of application of the fixateur externe at the femur\u2014Indications, results (author\u2019s transl)","volume":"12","author":"Hofmann","year":"1982","journal-title":"Aktuel. Traumatol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1055\/s-2008-1039299","article-title":"Die Therapie von Femurschaftfrakturen","volume":"147","author":"Hierholzer","year":"2009","journal-title":"Z. Orthop\u00e4die Unf."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"S61","DOI":"10.1016\/j.otsr.2016.11.006","article-title":"Limits of internal fixation in long-bone fracture","volume":"103","author":"Nieto","year":"2017","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1231","DOI":"10.1007\/s00068-020-01300-9","article-title":"Influence of a temporary stabilization device on respiratory status in patients with severe trauma with a femoral shaft fracture treated by damage control strategy","volume":"47","author":"Maury","year":"2021","journal-title":"Eur. J. Trauma Emerg. Surg."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1856","DOI":"10.1002\/jor.23193","article-title":"Age-related optimization of screw placement for reduced loosening risk in locked plating","volume":"34","author":"MacLeod","year":"2016","journal-title":"J. Orthop. Res."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"3282","DOI":"10.1016\/j.jbiomech.2008.08.013","article-title":"Structural properties of fourth-generation composite femurs and tibias","volume":"41","author":"Heiner","year":"2008","journal-title":"J. Biomech."},{"key":"ref_21","first-page":"111","article-title":"Composite Bone Models in Orthopaedic Surgery Research and Education","volume":"22","author":"Elfar","year":"2014","journal-title":"J. Am. Acad. Orthop. Surg."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"933","DOI":"10.1016\/S0021-9290(97)00057-2","article-title":"Internal forces and moments in the femur during walking","volume":"30","author":"Duda","year":"1997","journal-title":"J. Biomech."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1002\/jor.1100160413","article-title":"Local tissue properties in bone healing: Influence of size and stability of the osteotomy gap","volume":"16","author":"Augat","year":"1998","journal-title":"J. Orthop. Res."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Steiner, M., Claes, L., Ignatius, A., Simon, U., and Wehner, T. (2014). Numerical Simulation of Callus Healing for Optimization of Fracture Fixation Stiffness. PLoS ONE, 9.","DOI":"10.1371\/journal.pone.0101370"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1575","DOI":"10.2106\/00004623-200707000-00022","article-title":"Timely Fracture-Healing Requires Optimization of Axial Fixation Stability","volume":"89","author":"Epari","year":"2007","journal-title":"J. Bone Jt. Surg."},{"key":"ref_26","unstructured":"Catagni, M.A. (2003). Atlas for the Insertion of Transosseous Wires and Half-Pins, Medi Surgical Video. [2nd ed.]."}],"container-title":["Life"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-1729\/11\/11\/1254\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T07:31:52Z","timestamp":1760167912000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-1729\/11\/11\/1254"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,11,17]]},"references-count":26,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2021,11]]}},"alternative-id":["life11111254"],"URL":"https:\/\/doi.org\/10.3390\/life11111254","relation":{},"ISSN":["2075-1729"],"issn-type":[{"type":"electronic","value":"2075-1729"}],"subject":[],"published":{"date-parts":[[2021,11,17]]}}}