{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,7]],"date-time":"2026-02-07T12:18:52Z","timestamp":1770466732015,"version":"3.49.0"},"reference-count":49,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2023,10,24]],"date-time":"2023-10-24T00:00:00Z","timestamp":1698105600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Subsidiary of the PLA Major Project","award":["AWS17J004"],"award-info":[{"award-number":["AWS17J004"]}]},{"name":"Subsidiary of the PLA Major Project","award":["20230419"],"award-info":[{"award-number":["20230419"]}]},{"name":"PLA General Hospital\u2019s \u201c3+1\u201d Innovative Talent Training Program","award":["AWS17J004"],"award-info":[{"award-number":["AWS17J004"]}]},{"name":"PLA General Hospital\u2019s \u201c3+1\u201d Innovative Talent Training Program","award":["20230419"],"award-info":[{"award-number":["20230419"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Life"],"abstract":"<jats:p>The treatment of complex acetabular fractures remains a complicated clinical challenge. Our self-designed novel anatomical locking guide plate (NALGP) has previously shown promising potential in T-shaped acetabular fractures (TAF), but a direct comparison with conventional fixations is yet to be made. The TAF model was established based on a volunteer\u2019s computer tomography data and then fixed with double column locking plates (DLP), a posterior column locking plate with anterior column screws (LPACS), and our NALGP. Forces of 200 N, 400 N, and 600 N were then loaded on the model vertically downward, respectively. The stress distribution and peaks and maximum displacements at three sites were assessed. We found that the stress area of all three plates was mainly concentrated around the fracture line, while only the matching screws of the NALGP showed no obvious stress concentration points. In addition, the NALGP and DLP showed significantly less fracture fragment displacement than the LPACS at the three main fracture sites. The NALGP was found to have less displacement than DLP at the posterior column and ischiopubic branch sites, especially under the higher loading forces of 400 N and 600 N. The fixation stability of the NALGP for TAF was similar to that of DLP but better than that of LPACS. Moreover, the NALGP and its matching screws have a more reasonable stress distribution under different loads of force and the same strength as the LPACS.<\/jats:p>","DOI":"10.3390\/life13112108","type":"journal-article","created":{"date-parts":[[2023,10,24]],"date-time":"2023-10-24T06:29:01Z","timestamp":1698128941000},"page":"2108","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Comparison between Novel Anatomical Locking Guide Plate and Conventional Locking Plate for Acetabular Fractures: A Finite Element Analysis"],"prefix":"10.3390","volume":"13","author":[{"given":"Xiao","family":"Liu","sequence":"first","affiliation":[{"name":"Department of Orthopaedics, The First Medical Center of the Chinese PLA General Hospital, No. 28 Fuxin Road, Beijing 100853, China"},{"name":"National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, No. 28 Fuxin Road, Beijing 100853, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianpeng","family":"Gao","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The First Medical Center of the Chinese PLA General Hospital, No. 28 Fuxin Road, Beijing 100853, China"},{"name":"National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, No. 28 Fuxin Road, Beijing 100853, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaoyong","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The First Medical Center of the Chinese PLA General Hospital, No. 28 Fuxin Road, Beijing 100853, China"},{"name":"National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, No. 28 Fuxin Road, Beijing 100853, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Junhao","family":"Deng","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The First Medical Center of the Chinese PLA General Hospital, No. 28 Fuxin Road, Beijing 100853, China"},{"name":"National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, No. 28 Fuxin Road, Beijing 100853, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zijian","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The First Medical Center of the Chinese PLA General Hospital, No. 28 Fuxin Road, Beijing 100853, China"},{"name":"National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, No. 28 Fuxin Road, Beijing 100853, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ran","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The First Medical Center of the Chinese PLA General Hospital, No. 28 Fuxin Road, Beijing 100853, China"},{"name":"National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, No. 28 Fuxin Road, Beijing 100853, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Licheng","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The First Medical Center of the Chinese PLA General Hospital, No. 28 Fuxin Road, Beijing 100853, China"},{"name":"National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, No. 28 Fuxin Road, Beijing 100853, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianheng","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The First Medical Center of the Chinese PLA General Hospital, No. 28 Fuxin Road, Beijing 100853, China"},{"name":"National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, No. 28 Fuxin Road, Beijing 100853, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ming","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The First Medical Center of the Chinese PLA General Hospital, No. 28 Fuxin Road, Beijing 100853, China"},{"name":"National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, No. 28 Fuxin Road, Beijing 100853, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,10,24]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2267","DOI":"10.1016\/j.injury.2020.06.016","article-title":"Surgical management of acetabular fractures\u2014A contemporary literature review","volume":"51","author":"Kelly","year":"2020","journal-title":"Injury"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/BOT.0000000000001424","article-title":"Acetabulum Fractures: Classification and Management","volume":"33","author":"Letournel","year":"2019","journal-title":"J. Orthop. Trauma"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1093\/bja\/aei102","article-title":"Use of activated recombinant coagulation factor VII in patients undergoing reconstruction surgery for traumatic fracture of pelvis or pelvis and acetabulum: A double-blind, randomized, placebo-controlled trial","volume":"94","author":"Raobaikady","year":"2005","journal-title":"Br. J. Anaesth."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"103275","DOI":"10.1016\/j.otsr.2022.103275","article-title":"Pararectus approach vs. Stoppa approach for the treatment of acetabular fractures\u2014A comparison of approach-related complications and operative outcome parameters from the German Pelvic Registry","volume":"108","author":"Audretsch","year":"2022","journal-title":"Orthop. Traumatol. Surg. Res. OTSR"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1908","DOI":"10.1016\/j.injury.2014.09.004","article-title":"Displaced acetabular fractures in the elderly: Results after open reduction and internal fixation","volume":"45","author":"Li","year":"2014","journal-title":"Injury"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1016\/j.otsr.2019.11.019","article-title":"Epidemiology of pelvic and acetabular fractures in France","volume":"106","author":"Melhem","year":"2020","journal-title":"Orthop. Traumatol. Surg. Res. OTSR"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"103111","DOI":"10.1016\/j.otsr.2021.103111","article-title":"Use of 3D printing and pre-contouring plate in the surgical planning of acetabular fractures: A systematic review","volume":"108","author":"Papotto","year":"2022","journal-title":"Orthop. Traumatol. Surg. Res. OTSR"},{"key":"ref_8","first-page":"948","article-title":"Designation and Validation of a Posterior Anatomical Plate for the Anterior Column of the Acetabulum","volume":"23","author":"Zhang","year":"2017","journal-title":"Med. Sci. Monit. Int. Med. J. Exp. Clin. Res."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1111\/os.12648","article-title":"Single Ilioinguinal Approach to Treat Complex Acetabular Fractures with Quadrilateral Plate Involvement: Outcomes Using a Novel Dynamic Anterior Plate-Screw System","volume":"12","author":"Wu","year":"2020","journal-title":"Orthop. Surg."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Sakong, S.Y., Cho, J.W., Kim, B.S., Park, S.J., Lim, E.J., and Oh, J.K. (2023). The Clinical Efficacy of Contouring Periarticular Plates on a 3D Printed Bone Model. J. Pers. Med., 13.","DOI":"10.3390\/jpm13071145"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1969","DOI":"10.1007\/s00264-018-4111-8","article-title":"Pre-operative virtual simulation and three-dimensional printing techniques for the surgical management of acetabular fractures","volume":"43","author":"Hsu","year":"2019","journal-title":"Int. Orthop."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1186\/1749-799X-5-30","article-title":"Single column locking plate fixation is inadequate in two column acetabular fractures. A biomechanical analysis","volume":"5","author":"Khajavi","year":"2010","journal-title":"J. Orthop. Surg. Res."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.medengphy.2021.02.002","article-title":"Biomechanical analysis of fixation methods for acetabular fractures: A review","volume":"89","author":"Ferrante","year":"2021","journal-title":"Med. Eng. Phys."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"3786","DOI":"10.1016\/j.injury.2022.08.034","article-title":"Is the T-shaped acetabular fracture really likes a \u201cT\u201d? A study based on three-dimensional fracture mapping","volume":"53","author":"Ye","year":"2022","journal-title":"Injury"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Yang, Y., Zou, C., Fang, Y., and Shakya, S. (2022). Clinical efficacy and its influencing factors of surgical treatment for T-shaped associated with posterior wall acetabular fractures using combined surgical approaches. BMC Surg., 22.","DOI":"10.1186\/s12893-022-01467-5"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1097\/BOT.0b013e3181830d2a","article-title":"Simultaneous anterior and posterior approaches for complex acetabular fractures","volume":"22","author":"Harris","year":"2008","journal-title":"J. Orthop. Trauma"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1097\/00005131-200204000-00002","article-title":"Treatment of complex acetabular fractures through a modified extended iliofemoral approach","volume":"16","author":"Hoffmann","year":"2002","journal-title":"J. Orthop. Trauma"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1391","DOI":"10.1302\/0301-620X.87B10.16538","article-title":"Safety and efficacy of the extended iliofemoral approach in the treatment of complex fractures of the acetabulum","volume":"87","author":"Griffin","year":"2005","journal-title":"J. Bone Jt. Surg. Br. Vol."},{"key":"ref_19","first-page":"265","article-title":"Acetabular fractures treated surgically: Which of the parameters affect prognosis","volume":"26","author":"Bilekdemir","year":"2020","journal-title":"Ulus. Travma Ve Acil Cerrahi Derg. = Turk. J. Trauma Emerg. Surg. TJTES"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1302\/0301-620X.87B1.15605","article-title":"Operative treatment of displaced fractures of the acetabulum","volume":"87","author":"Giannoudis","year":"2005","journal-title":"Meta-Anal. J. Bone Jt. Surg. Br. Vol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"186","DOI":"10.55095\/achot2009\/035","article-title":"[Complications associated with the surgical treatment of acetabular fractures]","volume":"76","author":"Pavelka","year":"2009","journal-title":"Acta Chir. Orthop. Traumatol. Cechoslov."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1083","DOI":"10.1016\/j.injury.2020.12.011","article-title":"Transverse and transverse-variant acetabular fractures with ipsilateral sacroiliac joint injuries: A technical note for reduction and stabilization","volume":"52","author":"Shaath","year":"2021","journal-title":"Injury"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"680","DOI":"10.1016\/j.injury.2017.01.024","article-title":"The efficacy of posterior plating and anterior column screw fixation in the management of T-shaped acetabular fractures\u2014CART analysis of prospective cohort study","volume":"48","author":"Hammad","year":"2017","journal-title":"Injury"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"3353","DOI":"10.1007\/s11999-014-3800-x","article-title":"Are quadrilateral surface buttress plates comparable to traditional forms of transverse acetabular fracture fixation?","volume":"472","author":"Kistler","year":"2014","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1007\/s00064-019-00631-0","article-title":"Fluoroscopically guided acetabular posterior column screw fixation via an anterior approach","volume":"31","author":"Krappinger","year":"2019","journal-title":"Oper. Orthop. Traumatol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1016\/j.injury.2016.01.026","article-title":"Definition of a safe zone for antegrade lag screw fixation of fracture of posterior column of the acetabulum by 3D technology","volume":"47","author":"Feng","year":"2016","journal-title":"Injury"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2158","DOI":"10.1016\/j.injury.2020.07.008","article-title":"Biomechanical comparison of fixation techniques for transverse acetabular fractures\u2014Single-leg stance vs. sit-to-stand loading","volume":"51","author":"Schmoelz","year":"2020","journal-title":"Injury"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"S29","DOI":"10.1016\/j.injury.2015.05.029","article-title":"Finite element analysis of the stability of transverse acetabular fractures in standing and sitting positions by different fixation options","volume":"46","author":"Yildirim","year":"2015","journal-title":"Injury"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1007\/s00402-018-2868-2","article-title":"Evaluation of accuracy of virtual surgical planning for patient-specific pre-contoured plate in acetabular fracture fixation","volume":"138","author":"Maini","year":"2018","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"54","DOI":"10.5435\/00124635-199901000-00006","article-title":"Fractures of the posterior wall of the acetabulum","volume":"7","author":"Baumgaertner","year":"1999","journal-title":"J. Am. Acad. Orthop. Surg."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"e593","DOI":"10.3928\/01477447-20130426-21","article-title":"Development of site-specific locking plates for acetabular fractures","volume":"36","author":"Xu","year":"2013","journal-title":"Orthopedics"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"e660","DOI":"10.3928\/01477447-20140626-59","article-title":"Custom-made locked plating for acetabular fracture: A pilot study in 24 consecutive cases","volume":"37","author":"Xu","year":"2014","journal-title":"Orthopedics"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"S78","DOI":"10.1016\/j.injury.2015.10.045","article-title":"Rationale for more consistent choice of surgical approaches for acetabular fractures","volume":"46","author":"Gusic","year":"2015","journal-title":"Injury"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"e30","DOI":"10.1097\/BOT.0000000000000424","article-title":"Percutaneous Anterior Column Fixation for Acetabulum Fractures, Does It Have to Be Difficult?-The New Axial Pedicle View of the Anterior Column for Percutaneous Fixation","volume":"30","author":"Zhang","year":"2016","journal-title":"J. Orthop. Trauma"},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Zhang, L.H., Zhang, L.C., Si, Q.H., Gao, Y., Su, X.Y., Zhao, Z., and Tang, P.-F. (2016). Experimental study on treatment of acetabular anterior column fractures: Applyment of a minimally invasive percutaneous lag screw guide apparatus. BMC Musculoskelet. Disord., 17.","DOI":"10.1186\/s12891-015-0846-1"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1145","DOI":"10.1016\/j.injury.2010.08.011","article-title":"Acetabular both-column fractures: Essentials of operative management","volume":"41","author":"Pierannunzii","year":"2010","journal-title":"Injury"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1115\/1.1894148","article-title":"Subject-specific finite element model of the pelvis: Development, validation and sensitivity studies","volume":"127","author":"Anderson","year":"2005","journal-title":"J. Biomech. Eng."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1016\/0021-9290(94)00125-N","article-title":"Load transfer across the pelvic bone","volume":"28","author":"Dalstra","year":"1995","journal-title":"J. Biomech."},{"key":"ref_39","first-page":"81","article-title":"Acetabulum fractures: Classification and management","volume":"151","author":"Letournel","year":"1980","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"915","DOI":"10.2214\/AJR.05.1269","article-title":"Classification of common acetabular fractures: Radiographic and CT appearances","volume":"187","author":"Durkee","year":"2006","journal-title":"AJR Am. J. Roentgenol."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1007\/s40846-021-00655-7","article-title":"Finite Element Analysis of a Novel Anatomical Locking Guide Plate for Anterior Column and Posterior Hemi-Transverse Acetabular Fractures","volume":"41","author":"Deng","year":"2021","journal-title":"J. Med. Biol. Eng."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.jmbbm.2007.07.001","article-title":"Mechanical biocompatibilities of titanium alloys for biomedical applications","volume":"1","author":"Niinomi","year":"2008","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"1055","DOI":"10.1016\/j.otsr.2018.06.013","article-title":"Minimally invasive screw fixation is as stable as anterior plating in acetabular T-Type fractures\u2014A biomechanical study","volume":"104","author":"Becker","year":"2018","journal-title":"Orthop. Traumatol. Surg. Res. OTSR"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"e81","DOI":"10.2106\/JBJS.19.01027","article-title":"Biomechanical Comparison of Different Fixation Techniques for Typical Acetabular Fractures in the Elderly: The Role of Special Quadrilateral Surface Buttress Plates","volume":"102","author":"Chen","year":"2020","journal-title":"J. Bone Jt. Surg. Am. Vol."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1111\/j.1757-7861.2010.00099.x","article-title":"Reconstruction of type II+III pelvic resection with a modular hemipelvic endoprosthesis: A finite element analysis study","volume":"2","author":"Ji","year":"2010","journal-title":"Orthop. Surg."},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Li, D., Ren, H., Zhang, X., Ao, R., Yi, C., and Yu, B. (2023). Finite Element Analysis of Channel Screw and Conventional Plate Technique in Tile B2 Pelvic Fracture. J. Pers. Med., 13.","DOI":"10.3390\/jpm13030506"},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Zhang, D., Liu, N., Chen, Y., Zhang, G., Tian, J., Kong, F., Xiao, S., and Sun, J. (2020). Microstructure Evolution and Mechanical Properties of PM-Ti43Al9V0.3Y Alloy. Materials, 13.","DOI":"10.3390\/ma13010198"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1097\/00003086-200111000-00057","article-title":"Comparative strength of three methods of fixation of transverse acetabular fractures","volume":"392","author":"Chang","year":"2001","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Steiner, M., Claes, L., Ignatius, A., Simon, U., and Wehner, T. (2014). Numerical simulation of callus healing for optimization of fracture fixation stiffness. PLoS ONE, 9.","DOI":"10.1371\/journal.pone.0101370"}],"container-title":["Life"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-1729\/13\/11\/2108\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T21:10:57Z","timestamp":1760130657000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-1729\/13\/11\/2108"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,24]]},"references-count":49,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2023,11]]}},"alternative-id":["life13112108"],"URL":"https:\/\/doi.org\/10.3390\/life13112108","relation":{},"ISSN":["2075-1729"],"issn-type":[{"value":"2075-1729","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,10,24]]}}}