{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T23:38:40Z","timestamp":1770334720085,"version":"3.49.0"},"reference-count":18,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T00:00:00Z","timestamp":1770249600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Life"],"abstract":"<jats:p>Background: The implantable miniature telescope is used to provide functional vision for patients with advanced AMD. However, despite the considerable cost of the device, there are strict criteria to be met for this procedure, since the patients require challenging neuroadaptation afterward, which sometimes fails and leads to the necessity of device explantation. Visual outcomes also depend on the stability of the microtelescope; tilts cause unwanted optical aberrations and can lead to device luxation, with sight-threatening complications. Case report: This case presents a novel technique for fixing the ophthalmic telescope device SING-IMT\u2122. A 76-year-old female with pre-operative visual acuity of 15 letters on the ETDRS scale underwent surgery on her left eye. The superior haptic was fixed at the 12 o\u2019clock position with a Prolene 5-0 suture, achieving good postoperative stability. The implant was stable throughout the entire observation period. Conclusions: Implant stability is crucial for maximizing visual potential in patients with advanced AMD selected for the procedure, since visual acuity in the peripheral retina, where the perceived image eventually lands, is much lower than the macula. Therefore, there is a need to standardize surgical approaches and use objective follow-up measures to assess long-term patient satisfaction.<\/jats:p>","DOI":"10.3390\/life16020274","type":"journal-article","created":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T10:35:37Z","timestamp":1770287737000},"page":"274","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["New Technique of Single-Point Scleral Fixation of the Smaller-Incision New-Generation Implantable Miniature Telescope with an 18-Month Follow-Up Period"],"prefix":"10.3390","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8783-5606","authenticated-orcid":false,"given":"Agnieszka","family":"Nowosielska","sequence":"first","affiliation":[{"name":"Warsaw Eye Hospital, 01-258 Warsaw, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4640-8787","authenticated-orcid":false,"given":"Grzegorz","family":"Rotuski","sequence":"additional","affiliation":[{"name":"Warsaw Eye Hospital, 01-258 Warsaw, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2026,2,5]]},"reference":[{"key":"ref_1","first-page":"25158414251385884","article-title":"Do retinal implants provide long-term efficacy, safety and improve quality of life? A systematic review","volume":"17","author":"Alqahtani","year":"2025","journal-title":"Ther. Adv. Ophthalmol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1007\/s12015-024-10802-7","article-title":"Retinal Organoids from Induced Pluripotent Stem Cells of Patients with Inherited Retinal Diseases: A Systematic Review","volume":"21","author":"Lee","year":"2025","journal-title":"Stem Cell Rev. Rep."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"971","DOI":"10.1016\/j.oret.2022.05.017","article-title":"A New Intraocular Telescopic Device for Age-Related Macular Degeneration","volume":"6","author":"Savastano","year":"2022","journal-title":"Ophthalmol. Retin."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"835","DOI":"10.1111\/ceo.14294","article-title":"Treatment of dry age-related macular degeneration: A review","volume":"51","author":"Girgis","year":"2023","journal-title":"Clin. Exp. Ophthalmol."},{"key":"ref_5","first-page":"S2","article-title":"Geographic atrophy: Mechanism of disease, pathophysiology, and role of the complement system","volume":"29","author":"Bakri","year":"2023","journal-title":"J. Manag. Care Spec. Pharm."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1016\/j.ajo.2025.04.022","article-title":"Ocular Adverse Events Associated with Pegcetacoplan and Avacincaptad Pegol for Geographic Atrophy: A Population-Based Pharmacovigilance Study","volume":"276","author":"Kailani","year":"2025","journal-title":"Am. J. Ophthalmol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"5960328","DOI":"10.1155\/2021\/5960328","article-title":"Toric Intraocular Lens Implantation in the Correction of Moderate-To-High Corneal Astigmatism in Cataract Patients: Clinical Efficacy and Safety","volume":"2021","author":"Qiu","year":"2021","journal-title":"J. Ophthalmol."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Toro, M.D., Vidal-Aroca, F., Montemagni, M., Xompero, C., Fioretto, G., and Costagliola, C. (2023). Three-Month Safety and Efficacy Outcomes for the Smaller-Incision New-Generation Implantable Miniature Telescope (SING IMT\u2122). J. Clin. Med., 12.","DOI":"10.3390\/jcm12020518"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"104006","DOI":"10.1016\/j.jfo.2023.10.002","article-title":"Scharioth macula lens: Three-year follow-up","volume":"47","author":"Biarge","year":"2024","journal-title":"J. Fr. Ophtalmol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s10633-020-09814-8","article-title":"Vision before and after scharioth macular lens implantation in patients with AMD: An electrophysiological study","volume":"143","author":"Szanyi","year":"2021","journal-title":"Doc. Ophthalmol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"798","DOI":"10.1097\/IAE.0000000000004209","article-title":"SING-IMT Removal for Unsatisfied Patients: Step-by-Step Surgery for a Safe Explant","volume":"45","author":"Savastano","year":"2025","journal-title":"Retina"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1038\/s41433-025-03598-4","article-title":"Anatomical and functional results of patients with late-stage age-related macular degeneration 6 months after smaller-incision new-generation implantable miniature telescope (SING IMT\u2122) implantation","volume":"39","author":"Adamo","year":"2025","journal-title":"Eye"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1097\/ICB.0000000000001572","article-title":"Scleral Fixation of the Smaller-Incision New-Generation Implantable Miniature Telescope Using Gore-Tex Suture","volume":"19","author":"Savastano","year":"2025","journal-title":"Retin. Cases Brief Rep."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1953","DOI":"10.1007\/s00417-024-06444-7","article-title":"Scleral fixation of the Smaller-Incision New Generation Implantable Miniature Telescope (SING IMT\u2122)","volume":"262","author":"Eter","year":"2024","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1097\/j.jcrs.0000000000001327","article-title":"Ten-year results of scleral-fixated intraocular lens implantation: Outcomes of ab externo scleral fixation with 10-0 polypropylene suture","volume":"50","author":"Desai","year":"2024","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1089\/lap.2013.0352","article-title":"Suture choice matters in rabbit model of laparoscopic, preperitoneal, inguinal hernia repair","volume":"24","author":"Kelly","year":"2014","journal-title":"J. Laparoendosc. Adv. Surg. Tech. A"},{"key":"ref_17","first-page":"113","article-title":"18-month results of double-fanged 5-0 polypropylene suture transscleral bag fixation in subluxated cataracts","volume":"86","author":"Canabrava","year":"2023","journal-title":"Arq. Bras. Oftalmol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1097\/IAE.0000000000004289","article-title":"6\/0 Prolene Double-Flanged Intraocular Lens Sutureless Scleral Fixation with A 27-Gauge Needle for Intraocular Lens Surgery","volume":"45","author":"Pao","year":"2025","journal-title":"Retina"}],"container-title":["Life"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-1729\/16\/2\/274\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T10:48:30Z","timestamp":1770288510000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-1729\/16\/2\/274"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,5]]},"references-count":18,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,2]]}},"alternative-id":["life16020274"],"URL":"https:\/\/doi.org\/10.3390\/life16020274","relation":{},"ISSN":["2075-1729"],"issn-type":[{"value":"2075-1729","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,5]]}}}