{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,6]],"date-time":"2025-11-06T16:04:08Z","timestamp":1762445048883,"version":"build-2065373602"},"reference-count":33,"publisher":"MDPI AG","issue":"18","license":[{"start":{"date-parts":[[2020,9,4]],"date-time":"2020-09-04T00:00:00Z","timestamp":1599177600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea","doi-asserted-by":"publisher","award":["NRF-2020R1A2C3005687","NRF-2018R1A4A1026027"],"award-info":[{"award-number":["NRF-2020R1A2C3005687","NRF-2018R1A4A1026027"]}],"id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Materials"],"abstract":"<jats:p>Conventional slit dampers are widely used for the purpose of seismic retrofitting, however, the structure of these dampers is susceptible to fractures, due to stress concentration at the ends of the strips in the event of large earthquakes. To address this issue, a novel radius-cut coke-shaped strip damper featuring improved ductility is proposed herein. This damper was developed based on the moment distribution over the strip when both its ends were constrained. The height-to-width ratio of the strip was increased to induce bending rather than shear deformation, and the reduced beam section method was employed. A radius-cut section was used to intentionally focus the stress to induce the plastic hinge. This reduced the fracture fragility of the specimen, resulting in an increased inelastic deformation capacity. Cyclic loading tests were conducted to verify damping performance against earthquakes. Experiments and finite element analyses proved that the coke-shaped damper exhibits improved ductility. The final fracture occurred in the radius-cut section after sufficient energy dissipation during cyclic loading. The results also indicated further improvements in strength due to the membrane effect under cyclic loading, caused by the tensile resistance of the strip due to its constrained ends.<\/jats:p>","DOI":"10.3390\/ma13183920","type":"journal-article","created":{"date-parts":[[2020,9,4]],"date-time":"2020-09-04T12:20:06Z","timestamp":1599222006000},"page":"3920","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Cyclic Loading Performance of Radius-Cut Double Coke-Shaped Strip Dampers"],"prefix":"10.3390","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8940-5255","authenticated-orcid":false,"given":"Jaehoon","family":"Bae","sequence":"first","affiliation":[{"name":"School of Civil, Environmental and Architectural Engineering, Korea University, Anamdong, Seongbukgu, Seoul 136713, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9784-9902","authenticated-orcid":false,"given":"Chang-Hwan","family":"Lee","sequence":"additional","affiliation":[{"name":"Division of Architectural and Fire Protection Engineering, Pukyong National University, Busan 48513, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5903-2152","authenticated-orcid":false,"given":"Minjae","family":"Park","sequence":"additional","affiliation":[{"name":"School of Civil, Environmental and Architectural Engineering, Korea University, Anamdong, Seongbukgu, Seoul 136713, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1804-4004","authenticated-orcid":false,"given":"Robel Wondimu","family":"Alemayehu","sequence":"additional","affiliation":[{"name":"School of Civil, Environmental and Architectural Engineering, Korea University, Anamdong, Seongbukgu, Seoul 136713, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jaeho","family":"Ryu","sequence":"additional","affiliation":[{"name":"Technical Research Center, TechSquare Co., Ltd., 25 Banpo-daero, Seocho-gu, Seoul 06710, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Youngsik","family":"Kim","sequence":"additional","affiliation":[{"name":"Technical Research Center, TechSquare Co., Ltd., 25 Banpo-daero, Seocho-gu, Seoul 06710, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Young K.","family":"Ju","sequence":"additional","affiliation":[{"name":"School of Civil, Environmental and Architectural Engineering, Korea University, Anamdong, Seongbukgu, Seoul 136713, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2020,9,4]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"514","DOI":"10.1061\/(ASCE)ST.1943-541X.0000486","article-title":"Performance and Cost Evaluation of a Smart Tuned Mass Damper for Suppressing Wind-Induced Lateral-Torsional Motion of Tall Structures","volume":"138","author":"Tse","year":"2012","journal-title":"J. Struct. Eng."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1278","DOI":"10.1016\/j.jcsr.2010.04.005","article-title":"A hybrid passive control device for steel structures, I: Development and analysis","volume":"66","author":"Marshall","year":"2010","journal-title":"J. Constr. Steel Res."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/j.engstruct.2016.04.056","article-title":"Friction between a new low-steel composite material and milled steel for SAFE Dampers","volume":"122","author":"Lee","year":"2016","journal-title":"Eng. Struct."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.jcsr.2016.07.002","article-title":"Seismic collapse evaluation of steel moment resisting frames with superelastic viscous damper","volume":"126","author":"Silwal","year":"2016","journal-title":"J. Constr. Steel Res."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1016\/j.engstruct.2016.10.052","article-title":"Seismic loss assessment of a structure retrofitted with slit-friction hybrid dampers","volume":"130","author":"Kim","year":"2017","journal-title":"Eng. Struct."},{"key":"ref_6","first-page":"282","article-title":"Seismic design and assessment of steel frames with visco-plastic dampers","volume":"2","author":"Bae","year":"2019","journal-title":"Int. J. Earthq. Impact Eng."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Hwang, J.-H., Ock, J.-H., Kim, Y., Mauk, J.-W., and Bae, J. (2020). The Pushout Test of Seismic Reinforcement System (SRM) Connection that Respond to Earthquake Extensive Level. Int. J. Civ. Eng., 1\u201317.","DOI":"10.1007\/s40999-020-00544-1"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1262","DOI":"10.1177\/1369433216642068","article-title":"Cyclic loading test of wall damping system with steel dampers","volume":"19","author":"Ahn","year":"2016","journal-title":"Adv. Struct. Eng."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"04014206","DOI":"10.1061\/(ASCE)ST.1943-541X.0001183","article-title":"Modified Fatigue Model for Hourglass-Shaped Steel Strip Damper Subjected to Cyclic Loadings","volume":"141","author":"Lee","year":"2015","journal-title":"J. Struct. Eng."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1016\/j.istruc.2016.06.011","article-title":"A New Metallic Damper for Seismic Resilience: Analytical Feasibility Study","volume":"7","author":"Basu","year":"2016","journal-title":"Structures"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1007\/s11831-019-09329-9","article-title":"State-of-the-Art Review of Metallic Dampers: Testing, Development and Implementation","volume":"27","author":"Javanmardi","year":"2019","journal-title":"Arch. Comput. Methods Eng."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/j.engstruct.2017.12.049","article-title":"A passive metallic damper with replaceable steel bar components for earthquake protection of structures","volume":"159","author":"Aghlara","year":"2018","journal-title":"Eng. Struct."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1997","DOI":"10.1016\/j.engstruct.2009.03.003","article-title":"Seismic performance of steel structures with slit dampers","volume":"31","author":"Oh","year":"2009","journal-title":"Eng. Struct."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1007\/s13296-014-0121-6","article-title":"Experimental study of using cantilever type steel plates for passive energy dissipation","volume":"16","author":"Kim","year":"2016","journal-title":"Int. J. Steel Struct."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.jcsr.2017.05.005","article-title":"Seismic performance of steel plate slit-friction hybrid dampers","volume":"136","author":"Lee","year":"2017","journal-title":"J. Constr. Steel Res."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1058","DOI":"10.1016\/j.engstruct.2007.07.005","article-title":"Experimental study of steel slit damper for passive energy dissipation","volume":"30","author":"Chan","year":"2008","journal-title":"Eng. Struct."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2258","DOI":"10.1016\/j.engstruct.2010.03.028","article-title":"Shape optimization of metallic yielding devices for passive mitigation of seismic energy","volume":"32","author":"Ghabraie","year":"2010","journal-title":"Eng. Struct."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1193\/1.4000131","article-title":"Performance of Seismic Protection Technologies during the 2011 Tohoku-Oki Earthquake","volume":"29","author":"Kasai","year":"2013","journal-title":"Earthq. Spectra"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1829","DOI":"10.1193\/062617EQS131M","article-title":"Experimental Study of Low-Cycle Fatigue Behavior of a Welded Flange-Bolted Web Connection in Steel Moment-Resisting Frames","volume":"34","author":"Lee","year":"2018","journal-title":"Earthq. Spectra"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1061\/(ASCE)0733-9445(2002)128:4(441)","article-title":"Experimental Evaluation of Cyclically Loaded Reduced Beam Section Moment Connections","volume":"128","author":"Jones","year":"2002","journal-title":"J. Struct. Eng."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1016\/j.engstruct.2015.04.052","article-title":"Non-uniform steel strip dampers subjected to cyclic loadings","volume":"99","author":"Lee","year":"2015","journal-title":"Eng. Struct."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.engstruct.2016.04.019","article-title":"Hourglass-shaped strip damper subjected to monotonic and cyclic loadings","volume":"119","author":"Lee","year":"2016","journal-title":"Eng. Struct."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1016\/j.engstruct.2016.02.007","article-title":"Numerical and experimental analysis of combined behavior of shear-type friction damper and non-uniform strip damper for multi-level seismic protection","volume":"114","author":"Lee","year":"2016","journal-title":"Eng. Struct."},{"key":"ref_24","unstructured":"Architectural Institute of Korea (2019). KDS 41 17 00. Seismic Building Design Code, Ministry of Land."},{"key":"ref_25","unstructured":"International System of Units (2010). ASCE\/SEI 7-10. Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineers."},{"key":"ref_26","unstructured":"American Society of Civil Engineers (2017). Minimum Design Loads and Associated Criteria for Buildings and Other Structures, American Society of Civil Engineers."},{"key":"ref_27","unstructured":"FEMA (2000). Prestandard and Commentary for the Seismic Rehabilitation of Buildings."},{"key":"ref_28","unstructured":"Korean Agency for Technology and Standards (2008). KS B 0802, Method of Tensile Test. for Metallic Materials."},{"key":"ref_29","unstructured":"Korean Agency for Technology and Standards (2008). KS D 3503, Rolled Steels for General Structure."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Bae, J., Lee, C.-H., Park, M., Alemayehu, R.W., Ryu, J., and Ju, Y.K. (2020). Modified Low-Cycle Fatigue Estimation Using Machine Learning for Radius-Cut Coke-Shaped Metallic Damper Subjected to Cyclic Loading. Int. J. Steel Struct., 1\u201310.","DOI":"10.1007\/s13296-020-00377-7"},{"key":"ref_31","unstructured":"Korean Building Code (2016). KBC2016: 0306.13.6. Testing of Damping Devices, Architectural Institute of Korea."},{"key":"ref_32","unstructured":"Kato, B., Akiyama, H., and Yamanouchi, H. (1973). Predictable properties of material under incremental cyclic loading. Proceedings of the IABSE Symposium-International Association for Bridge and Structural Engineering, International Association for Bridge and Structural Engineering."},{"key":"ref_33","unstructured":"Chopra, A.K. (1995). Dynamics of Structures: Theory and Applications to Earthquake Engineering, Prentice Hall. [2nd ed.]."}],"container-title":["Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1996-1944\/13\/18\/3920\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T10:06:58Z","timestamp":1760177218000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1996-1944\/13\/18\/3920"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,4]]},"references-count":33,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2020,9]]}},"alternative-id":["ma13183920"],"URL":"https:\/\/doi.org\/10.3390\/ma13183920","relation":{},"ISSN":["1996-1944"],"issn-type":[{"type":"electronic","value":"1996-1944"}],"subject":[],"published":{"date-parts":[[2020,9,4]]}}}