{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T23:04:12Z","timestamp":1789167852894,"version":"build-2803163510"},"reference-count":87,"publisher":"MDPI AG","issue":"23","license":[{"start":{"date-parts":[[2020,11,24]],"date-time":"2020-11-24T00:00:00Z","timestamp":1606176000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Materials"],"abstract":"<jats:p>Although ceramic-on-ceramic (CoC) bearings have been shown to produce the smallest amount of wear volume in vitro as well as in vivo studies when used for total hip arthroplasties (THA), concerns about the failure of these bearing surfaces persist due to early failures observed after short postoperative time. In this study, an exhaustive analysis of the early failure occurred on the new generation of ceramic bearings, consisting of a composite alumina matrix-based material reinforced with yttria-stabilized tetragonal zirconia (Y-TZP) particles, chromium dioxide, and strontium crystals, was performed. For this study, 118 CoC bearings from 117 patients were revised. This article describes a group of mechanical failure CoC-bearing BIOLOX THA hip prosthesis patients without trauma history. The retrieved samples were observed under scanning electron microscopy (SEM), composition was analyzed with energy dispersive X-ray spectroscopy (EDX), and damaged surfaces were analyzed by grazing-incidence X-ray diffraction (GI-XRD) and white light interferometry. In the short term, CoC articulations provided similar mechanical behavior and functional outcome to those in XLPE cases. However, 5% more early mechanical failures cases were observed for the ceramic components. Although the fracture rate of third generation CoC couples is low, the present study shows the need to further improve the third generation of CoC-bearing couples for THA. Despite the improved wear compared to other materials, stress concentrators are sources of initial crack propagation, such as those found in the bore-trunnion areas. Moreover, in view of the evidence observed in this study, the chipping observed was due to the presence of monoclinic phase of the Y-TZP instead of tetragonal, which presents better mechanical properties. The results showed that total safety after receiving a THA is still a goal to be pursued.<\/jats:p>","DOI":"10.3390\/ma13235318","type":"journal-article","created":{"date-parts":[[2020,11,24]],"date-time":"2020-11-24T20:50:22Z","timestamp":1606251022000},"page":"5318","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Early Short-Term Postoperative Mechanical Failures of Current Ceramic-on-Ceramic Bearing Total Hip Arthroplasties"],"prefix":"10.3390","volume":"13","author":[{"given":"Mariano","family":"Fern\u00e1ndez-Fair\u00e9n","sequence":"first","affiliation":[{"name":"Bioengineering Institute of Technology, Facultat de Medicina y Ciencias de la Salud, Universitat Internacional de Catalunya, 080195 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ana","family":"Torres-Perez","sequence":"additional","affiliation":[{"name":"Hospital Universitario Santa Luc\u00eda, Calle Mezquita, s\/n, 30202 Cartagena, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0823-2303","authenticated-orcid":false,"given":"Roman","family":"Perez","sequence":"additional","affiliation":[{"name":"Bioengineering Institute of Technology, Facultat de Medicina y Ciencias de la Salud, Universitat Internacional de Catalunya, 080195 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1904-8667","authenticated-orcid":false,"given":"Miquel","family":"Punset","sequence":"additional","affiliation":[{"name":"Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Engineering, Escola d\u2019Enginyeria de Barcelona Est (EEBE), Universitat Polit\u00e8cnica de Catalunya (UPC), Carrer de Jordi Girona 1, 08034 Barcelona, Spain"},{"name":"Barcelona Research Centre in Multiscale Science and Engineering, Technical University of Catalonia (UPC), Av. Eduard Maristany, 10\u201314, 08019 Barcelona, Spain"},{"name":"UPC Innovation and Technology Center (CIT-UPC), Technical University of Catalonia (UPC), C. Jordi Girona 3\u20131, 08034 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meritxell","family":"Molmeneu","sequence":"additional","affiliation":[{"name":"Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Engineering, Escola d\u2019Enginyeria de Barcelona Est (EEBE), Universitat Polit\u00e8cnica de Catalunya (UPC), Carrer de Jordi Girona 1, 08034 Barcelona, Spain"},{"name":"Barcelona Research Centre in Multiscale Science and Engineering, Technical University of Catalonia (UPC), Av. Eduard Maristany, 10\u201314, 08019 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8875-9131","authenticated-orcid":false,"given":"Monica","family":"Ortiz-Hern\u00e1ndez","sequence":"additional","affiliation":[{"name":"Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Engineering, Escola d\u2019Enginyeria de Barcelona Est (EEBE), Universitat Polit\u00e8cnica de Catalunya (UPC), Carrer de Jordi Girona 1, 08034 Barcelona, Spain"},{"name":"Barcelona Research Centre in Multiscale Science and Engineering, Technical University of Catalonia (UPC), Av. Eduard Maristany, 10\u201314, 08019 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9 Mar\u00eda","family":"Manero","sequence":"additional","affiliation":[{"name":"Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Engineering, Escola d\u2019Enginyeria de Barcelona Est (EEBE), Universitat Polit\u00e8cnica de Catalunya (UPC), Carrer de Jordi Girona 1, 08034 Barcelona, Spain"},{"name":"Barcelona Research Centre in Multiscale Science and Engineering, Technical University of Catalonia (UPC), Av. Eduard Maristany, 10\u201314, 08019 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Javier","family":"Gil","sequence":"additional","affiliation":[{"name":"Bioengineering Institute of Technology, Facultat de Medicina y Ciencias de la Salud, Universitat Internacional de Catalunya, 080195 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2020,11,24]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Kluge, F.A., Goldstein, J.R., and Vogt, T.C. (2018). Transfers in an Aging European Union. J. Econ. Ageing.","DOI":"10.1016\/j.jeoa.2018.07.004"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1285","DOI":"10.1016\/j.arth.2013.12.024","article-title":"Early Failures in Total Hip Arthroplasty\u2014A Changing Paradigm","volume":"29","author":"Karthikeyan","year":"2014","journal-title":"J. Arthroplast."},{"key":"ref_3","unstructured":"The Organization for Economic Cooperation and Development (2012). Infant Health: Low Birth Weight. Health at a Glance: Europe, OECD Publishing."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Malem, D., Nagy, M.T., Ghosh, S., and Shah, B. (2013). Catastrophic Failure of Ceramic-on-Ceramic Total Hip Arthroplasty Presenting as Squeaking Hip. BMJ Case Rep.","DOI":"10.1136\/bcr-2013-008614"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Kim, S.Y. (2010). What Are the Options for Better Outcomes of Total Hip Arthroplasty?. Clin. Orthop. Surg., 2.","DOI":"10.4055\/cios.2010.2.4.195"},{"key":"ref_6","first-page":"1","article-title":"Ceramic Bearings Fracture: A Literature Review on Risk Factors, Diagnosis, and Treatment","volume":"8","author":"Aprato","year":"2020","journal-title":"J. Surg. Trauma"},{"key":"ref_7","first-page":"181","article-title":"Alumina on Alumina Versus Metal on Conventional Polyethylene: A Randomized Clinical Trial with 9 to 15 Years\u2019 Follow-Up","volume":"79","author":"Vendittoli","year":"2013","journal-title":"Acta Orthop. Belg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1007\/s11999-011-2076-7","article-title":"Ceramic Bearings for Total Hip Arthroplasty Have High Survivorship at 10 Years","volume":"470","author":"Capello","year":"2012","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.arth.2011.05.022","article-title":"Ceramic-on-Ceramic Total Hip Arthroplasty in Patients Younger Than 20 Years","volume":"27","author":"Finkbone","year":"2012","journal-title":"J. Arthroplast."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1016\/j.arth.2011.04.042","article-title":"Modern Total Hip Arthroplasty in Patients Younger Than 21 Years","volume":"27","author":"Kamath","year":"2012","journal-title":"J. Arthroplast."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1007\/s10195-011-0170-y","article-title":"Congenital Hip Dysplasia Treated by Total HIP Arthroplasty Using Cementless Tapered Stem in Patients Younger Than 50 Years Old: Results After 12-Years Follow-Up","volume":"12","author":"Faldini","year":"2011","journal-title":"J. Orthop. Traumatol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1097\/01.blo.0000150132.11142.d2","article-title":"Concerns About Ceramics in THA","volume":"429","author":"Barrack","year":"2004","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1177\/112070000701700105","article-title":"A Review of Ceramic Bearing Materials in Total Joint Arthroplasty","volume":"17","author":"Bal","year":"2007","journal-title":"HIP Int."},{"key":"ref_14","first-page":"E26","article-title":"Ceramic Total Hip Arthroplasty in the United States: Safety and Risk Issues Revisited","volume":"37","author":"Tateiwa","year":"2008","journal-title":"Am. J. Orthop."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"825","DOI":"10.2106\/00004623-200305000-00009","article-title":"Revision Total Hip Arthroplasty Performed After Fracture of a Ceramic Femoral Head. A Multicenter Survivorship Study","volume":"85","author":"Allain","year":"2003","journal-title":"J. Bone Joint Surg. A"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2270","DOI":"10.2106\/00004623-200212000-00022","article-title":"Early Clinical Failure of Total Joint Replacement in Association with Follicular Proliferation of B-Lymphocytes: A Report of Two Cases","volume":"84","year":"2002","journal-title":"J. Bone Joint Surg. A"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1016\/j.arth.2009.01.014","article-title":"Revision Total Hip Arthroplasty for Ceramic Head Fracture: A Long-Term Follow-Up","volume":"25","author":"Sharma","year":"2020","journal-title":"J. Arthroplast."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"45","DOI":"10.5435\/JAAOS-D-15-00754","article-title":"Bearing Surfaces for Total Hip Arthroplasty","volume":"26","author":"Lachiewicz","year":"2018","journal-title":"J. Am. Acad. Orthop. Surg."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1012","DOI":"10.1302\/0301-620X.99B8.BJJ-2017-0019.R1","article-title":"Ceramic-on-Ceramic Bearing Fractures in Total Hip Arthroplasty: An Analysis of Data from the National Joint Registry","volume":"99-B","author":"Howard","year":"2017","journal-title":"Bone Joint J."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1016\/j.arth.2016.08.011","article-title":"Incidence of Modern Alumina Ceramic and Alumina Matrix Composite Femoral Head Failures in Nearly 6 Million Hip Implants","volume":"32","author":"Lee","year":"2016","journal-title":"J. Arthroplast."},{"key":"ref_21","unstructured":"Abdel, M.P., and Della Valle, C.J. (2017). Complications of Ceramic-on-Ceramic Bearings: Fracture, Stripe Wear, and Squeaking. Complications after Primary Total Hip Arthroplasty: A Comprehensive Clinical Guide, Springer International Publishing."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1177\/0954411913489803","article-title":"Clinical Failure Analysis of Contemporary Ceramic-on-Ceramic Total Hip Replacements","volume":"227","author":"Brandt","year":"2013","journal-title":"Proc. Inst. Mech. Eng. H"},{"key":"ref_23","first-page":"1064","article-title":"Failure Causes in Total Hip Replacements: A Review","volume":"5","author":"Sipek","year":"2018","journal-title":"Austin J. Orthop. Rheumatol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1016\/j.ijscr.2019.10.079","article-title":"Ceramic Liner Fracture in Ceramic on Ceramic Total Hip Arthoplasty: A Case Report","volume":"65","author":"Pawar","year":"2019","journal-title":"Int. J. Surg. Case Rep."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"158.e5","DOI":"10.1016\/j.arth.2008.01.310","article-title":"Delayed Catastrophic Failure of a Ceramic Head in Hybrid Total Hip Arthroplasty","volume":"24","author":"Anwar","year":"2009","journal-title":"J. Arthroplast."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"204","DOI":"10.5507\/bp.2012.063","article-title":"Advantages and Disadvantages of Ceramic on Ceramic Total Hip Arthroplasty: A Review","volume":"156","author":"Gallo","year":"2012","journal-title":"Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1177\/0954411912474613","article-title":"Wear of 36-mm BIOLOX(R) Delta Ceramic-on-Ceramic Bearing in Total Hip Replacements under Edge Loading Conditions","volume":"227","author":"Fisher","year":"2013","journal-title":"Proc. Inst. Mech. Eng. H"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1325","DOI":"10.1007\/s00402-014-2020-x","article-title":"Ceramic on Ceramic Hip Prostheses: A Review of Past and Modern Materials","volume":"134","author":"Macdonald","year":"2014","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"847","DOI":"10.1177\/0954411913488508","article-title":"Does Surface Wettability Influence the Friction and Wear of Large-Diameter CoCrMo alloy Hip Resurfacings?","volume":"227","author":"Curran","year":"2013","journal-title":"Proc. Inst. Mech. Eng. H"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1016\/j.arth.2010.04.029","article-title":"Ceramic-on-Ceramic Hip Outcome at a 5- to 10-Year Interval: Has It Lived Up to Its Expectations?","volume":"26","author":"Mesko","year":"2011","journal-title":"J. Arthroplast."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Hu, D., Tie, K., Yang, X., Alaidaros, M., and Chen, L. (2015). Comparison of Ceramic-on-Ceramic to Metal-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty: A Meta-Analysis of Randomized Controlled Trials. J. Orthop. Surg. Res., 10.","DOI":"10.1186\/s13018-015-0163-2"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1302\/0301-620X.94B11.30508","article-title":"Large Diameter Heads: Is Bigger Always Better?","volume":"94","author":"Rodriguez","year":"2012","journal-title":"J. Bone Joint Surg. Br."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1302\/2058-5241.3.170061","article-title":"Head Size in Primary Total Hip Arthroplasty","volume":"3","author":"Tsikandylakis","year":"2018","journal-title":"EFORT Open Rev."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1007\/s11999-009-1091-4","article-title":"THA with Delta Ceramic on Ceramic: Results of a Multicenter Investigational Device Exemption Trial","volume":"468","author":"Hamilton","year":"2010","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"329","DOI":"10.2106\/JBJS.F.01489","article-title":"Isolated Fracture of the Ceramic Head After Third-Generation Alumina-on-Alumina Total Hip Arthroplasty","volume":"90","author":"Koo","year":"2008","journal-title":"J. Bone Joint Surg. Am."},{"key":"ref_36","first-page":"780","article-title":"Ceramic Failure After Total Hip Arthroplasty with an Alumina-Onalumina Bearing","volume":"88","author":"Park","year":"2006","journal-title":"J. Bone Joint Surg. Am."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1239.e25","DOI":"10.1016\/j.arth.2007.09.017","article-title":"Fracture of an Alumina Femoral Head Used in Ceramic-on-Ceramic Total Hip Arthroplasty","volume":"23","author":"Rhoads","year":"2008","journal-title":"J. Arthroplast."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.arth.2008.06.003","article-title":"Ceramic-on-Ceramic Total Hip Arthroplasty: Update","volume":"23","author":"Capello","year":"2008","journal-title":"J. Arthroplast."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1097\/BLO.0b013e3180303e87","article-title":"Ceramic Liner Fracture after Cementless Alumina-on-Alumina Total Hip Arthroplasty","volume":"458","author":"Ha","year":"2007","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1097\/01.blo.0000096806.78689.50","article-title":"Fractures of Ceramic Bearings: History and Present Status","volume":"417","author":"Hamouche","year":"2003","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1016\/j.arth.2006.05.020","article-title":"Alumina Femoral Head Fracture in Uncemented Total Hip Arthroplasty with a Ceramic Sandwich Cup","volume":"22","author":"Hwang","year":"2007","journal-title":"J. Arthroplast."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"2065","DOI":"10.1016\/j.arth.2019.04.068","article-title":"Delta-on-Delta Ceramic Bearing Surfaces in Revision Hip Arthroplasty","volume":"34","author":"Castagnini","year":"2019","journal-title":"J. Arthroplast."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1053\/j.sart.2012.12.007","article-title":"Total Hip Replacement: Ceramic-on-Ceramic","volume":"23","author":"Jenabzadeh","year":"2012","journal-title":"Semin. Arthroplast."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1097\/00003086-199209000-00003","article-title":"Biocompatibility of Surgical-Grade Dense Polycrystalline Al\u00famina","volume":"282","author":"Christel","year":"1992","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1302\/0301-620X.98B1.36347","article-title":"Ceramic on Ceramic Arthroplasty of the Hip: New Materials Confirm Appropriate Use in Young Patients","volume":"98","author":"Sentuerk","year":"2016","journal-title":"Bone Joint J."},{"key":"ref_46","unstructured":"Lee, G. (2017). Ceramic Component Fracture: Getting Rarer, but When It Happens?. Orthop. Proc., 99."},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Chang, J.-D., Kimm, I.-S., Mansukhani, S.A., Sharma, V., Lee, S.-S., and Yoo, J.-H. (2018). Midterm Outcome of Fourth-Generation Ceramic-on-Ceramic Bearing Surfaces in Revision Total Hip Arthroplasty. J. Orthop. Surg., 26.","DOI":"10.1177\/2309499018783913"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1016\/j.arth.2006.11.018","article-title":"Lining up the Liner: 2 Case Reports of Early Ceramic Liner Fragmentation","volume":"22","author":"McCarthy","year":"2007","journal-title":"J. Arthroplast."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.arth.2005.12.012","article-title":"Delayed Fracture of a Ceramic Insert with Modern Ceramic Total Hip Replacement","volume":"22","author":"Min","year":"2007","journal-title":"J. Arthroplast."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"367","DOI":"10.2106\/00004623-200702000-00019","article-title":"Failure Analysis of a Ceramic Bearing Acetabular Component","volume":"89","author":"Poggie","year":"2007","journal-title":"J. Bone Joint Surg. Am."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1016\/j.arth.2005.03.045","article-title":"Fracture of a Ceramic Femoral Head after Ceramic-on-Ceramic Total Hip Arthroplasty","volume":"21","author":"Toran","year":"2006","journal-title":"J. Arthroplast."},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Zippel, H., and Dietrich, M. (2003). Fiction and Facts Concerning the Reliability of Ceramics in THR. Bioceramics in Joint Arthroplasty, Steinkopff Verlag.","DOI":"10.1007\/978-3-642-85763-8"},{"key":"ref_53","first-page":"738","article-title":"The Squeaking Hip: A Cause for Concern\u2014Agrees","volume":"30","author":"Ranawat","year":"2007","journal-title":"Orthopedics"},{"key":"ref_54","unstructured":"ISO (2015). Retrieval and Analysis of Surgical Implants\u2014Part 1: Retrieval and Handling, ISO. 12891\u20131:2015."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1016\/j.arth.2006.06.018","article-title":"Squeaking in Ceramic-on-Ceramic Hips: The Importance of Acetabular Component Orientation","volume":"22","author":"Walter","year":"2007","journal-title":"J. Arthroplast."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1016\/S0883-5403(03)00193-1","article-title":"Ceramic Acetabular Liner Fracture in Total Hip Arthroplasty with a Ceramic Sandwich Cup","volume":"18","author":"Hasegawa","year":"2003","journal-title":"J. Arthroplast."},{"key":"ref_57","doi-asserted-by":"crossref","unstructured":"Lee, S.C., Jung, K.A., Nam, C.H., Kim, T.H., Ahn, N.K., and Hwang, S.H. (2010). Acetabular Screw Head-Induced Ceramic Acetabular Liner Fracture in Cementless Ceramic-on-Ceramic Total Hip Arthroplasty. Orthopedics, 12.","DOI":"10.3928\/01477447-20100329-30"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1016\/S0883-5403(05)80089-0","article-title":"Spontaneous Fracture of the Ceramic Ball in a Ceramic-Polyethylene Total Hip Arthroplasty","volume":"10","author":"Michaud","year":"1995","journal-title":"J. Arthroplast."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"118","DOI":"10.2106\/00004623-199701000-00013","article-title":"Fracture of a Ceramic Femoral Head after a Revision Operation. A Case Report","volume":"79","author":"Pulliam","year":"1997","journal-title":"J. Bone Joint Surg. Am."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1002\/jemt.10358","article-title":"Applications of Environmental Scanning Electron Microscopy (ESEM) in Biomaterials Field","volume":"61","author":"Manero","year":"2003","journal-title":"Microsc. Res. Tech."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"1181","DOI":"10.1007\/s10856-004-5953-8","article-title":"Microstructural, Mechanical and Citotoxicity Evaluation of Different NiTi and NiTiCu Shape Memory Alloys","volume":"15","author":"Gil","year":"2004","journal-title":"J. Mater. Sci. Mater. Med."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1002\/(SICI)1097-4636(19981205)42:3<403::AID-JBM8>3.0.CO;2-N","article-title":"The Cement Setting Reaction in the CaHPO4-\u03b1Ca3(PO4)2 System: An X-ray Diffraction Study","volume":"42","author":"Gil","year":"1998","journal-title":"J. Biomed. Mater. Res."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1002\/jbm.b.30663","article-title":"Microstructure and Macroscopic Properties of Bioactive CaO-SiO2-PDMS Hybrids","volume":"81","author":"Salinas","year":"2007","journal-title":"J. Biomed. Mater. Res. B Appl. Biomater."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"e91","DOI":"10.3928\/01477447-20111122-33","article-title":"Fracture of the Alumina-Bearing Couple Delta Ceramic Liner","volume":"35","author":"Taheriazam","year":"2012","journal-title":"Orthopedics"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"1353","DOI":"10.1039\/B415134H","article-title":"Bioactivity and mechanical properties of SiO2-CaO-P2O5 glass-ceramics","volume":"15","author":"Padilla","year":"2005","journal-title":"J. Mater. Chem."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"147","DOI":"10.2106\/JBJS.K.00589","article-title":"Revision of Ceramic Hip Replacements for Fracture of a Ceramic Component: AAOS Exhibit Selection","volume":"93","author":"Traina","year":"2011","journal-title":"J. Bone Joint Surg. A"},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1097\/00003086-200010000-00016","article-title":"Press-Fit Metal-Backed Alumina Sockets: A Minimum 5-Year Follow Up Study","volume":"379","author":"Bizot","year":"2000","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"1688","DOI":"10.2106\/00004623-200111000-00011","article-title":"Ceramic-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty. Seventeen to Twenty-One-Year Results","volume":"83","author":"Urban","year":"2001","journal-title":"J. Bone Joint Surg. Am."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/S0883-5403(98)90085-7","article-title":"Catastrophic Failure of the Acetabular Component in a Ceramic-Polyethylene Bearing Total Hip Arthroplasty","volume":"13","author":"Simon","year":"1998","journal-title":"J. Arthroplast."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1097\/00003086-200010000-00004","article-title":"Ceramic Femoral Head Retrieval Data","volume":"379","author":"Willmann","year":"2000","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1007\/s00264-007-0484-9","article-title":"Emergence of the Alumina Matrix Composite in Total Hip Arthroplasty","volume":"33","author":"Masson","year":"2009","journal-title":"Int. Orthop."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"937","DOI":"10.1016\/S0142-9612(01)00206-X","article-title":"Crack Growth Resistance of Alumina, Zirconia and Zirconia Toughened Alumina Ceramics for Joint Prostheses","volume":"23","author":"Chevalier","year":"2002","journal-title":"Biomaterials"},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"5279","DOI":"10.1016\/j.biomaterials.2009.06.022","article-title":"On the Kinetics and Impact of Tetragonal to Monoclinic Transformation in an Alumina\/Zirconia Composite for Arthroplasty Applications","volume":"30","author":"Chevalier","year":"2009","journal-title":"Biomaterials"},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"898","DOI":"10.1016\/j.arth.2004.02.045","article-title":"Zirconia Femoral Head Fractures","volume":"19","author":"Masonis","year":"2004","journal-title":"J. Arthroplast."},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1097\/01.blo.0000246544.95316.1f","article-title":"Zirconia versus Co-Cr Femoral Heads in Total Hip Arthroplasty: Early Assessment of Wear","volume":"453","author":"Kraay","year":"2006","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.msec.2009.08.002","article-title":"Evaluating mechanical properties and degradation","volume":"20","author":"Sevilla","year":"2010","journal-title":"Mater. Sci. Eng. C"},{"key":"ref_77","doi-asserted-by":"crossref","unstructured":"Garino, J.P. (2000). Modern Ceramic-on-Ceramic Total Hip Systems in the United States: Early Results. Clin. Orthop. Relat. Res., 41\u201347.","DOI":"10.1097\/00003086-200010000-00007"},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"69","DOI":"10.2106\/00004623-200201000-00011","article-title":"Alumina-on-Alumina Total hip Arthroplasty: A Minimum 18.5-Year Follow-Up Study","volume":"84","author":"Hamadouche","year":"2002","journal-title":"J. Bone Joint Surg. Am."},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1016\/S0883-5403(05)80087-7","article-title":"Fracture of the Femoral Head after Ceramic-on-Polyethylene Total Hip Arthroplasty","volume":"10","author":"Callaway","year":"1995","journal-title":"J. Arthroplast."},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1302\/0301-620X.89B3.18473","article-title":"Incomplete Seating of the Liner with the Trident Acetabular System: A Cause for Concern?","volume":"89","author":"Langdown","year":"2007","journal-title":"J. Bone Joint Surg. Br."},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/j.jor.2013.04.007","article-title":"Laser Etching Causing Fatigue Fracture at the Neck-Shoulder Junction of an Uncemented Femoral Stem: A Case Report","volume":"10","author":"Jang","year":"2013","journal-title":"J. Orthop."},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1054\/arth.2001.20542","article-title":"Early Fatigue Failures of Cemented, Forged, Cobalt-Chromium Femoral Stems at the Neck-Shoulder Junction","volume":"16","author":"Lee","year":"2001","journal-title":"J. Arthroplast."},{"key":"ref_83","first-page":"415","article-title":"Failures of Yttria-Stabilised Tetragonal Zirconia: 52 Retrieved Ceramic Femoral Heads of Total Hip Prostheses","volume":"16","author":"Sala","year":"2006","journal-title":"Biomed. Mater. Eng."},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1097\/BLO.0b013e31811eb4c3","article-title":"Aging of Retrieved Zirconia Femoral Heads","volume":"462","author":"Blanco","year":"2007","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_85","first-page":"486","article-title":"Accelerating Aging of Zirconia Femoral Head Implants: Change of Surface Structure and Mechanical Properties","volume":"81","author":"Chowdhury","year":"2006","journal-title":"J. Biomed. Mater. Res. B Appl. Biomater."},{"key":"ref_86","doi-asserted-by":"crossref","unstructured":"Colombo, M., Poggio, C., Lasagna, A., Chiesa, M., and Scribante, A. (2019). Vickers Micro-Hardness of New Restorative CAD\/CAM Dental Materials: Evaluation and Comparison after Exposure to Acidic Drink. Materials, 12.","DOI":"10.3390\/ma12081246"},{"key":"ref_87","doi-asserted-by":"crossref","unstructured":"Iinuma, Y., Hirota, M., Hayakawa, T., and Ohkubo, C. (2020). Surrounding Tissue Response to Surface-Treated Zirconia Implants. Materials, 13.","DOI":"10.3390\/ma13010030"}],"container-title":["Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1996-1944\/13\/23\/5318\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T10:36:41Z","timestamp":1760179001000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1996-1944\/13\/23\/5318"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,11,24]]},"references-count":87,"journal-issue":{"issue":"23","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["ma13235318"],"URL":"https:\/\/doi.org\/10.3390\/ma13235318","relation":{},"ISSN":["1996-1944"],"issn-type":[{"value":"1996-1944","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,11,24]]}}}